Thermo-Gel® POK 5 Gallon System

Slides:



Advertisements
Similar presentations
The Basics Equipment Maintenance and Safety
Advertisements

$200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 Tip SizesNozzlesPotpourriFormulas.
Kegging and Draft Systems. Kegging Pros: Time Ease of cleaning Carbonation precision No sediment – good for comps Potentially lower long term costs Easy.
Practical Nursing Diploma Program - Semester 2 Lab Oxygen therapy, Incentive Spirometry, Pulse Oximetry &Sputum Collection.
2 Fire Fighter Qualifications and Safety Skill Drills.
1 Low Conductivity Water (LCW) Connection Training Environmental Energy Technologies Division Safety Topic January 9, 2012.
Technical support provided by: Highly Pathogenic Avian Influenza Control Programme SOP Use and Maintenance of High Pressure Washer Machine Market chain.
Intermediate SFFMA Objectives: – Hrs received.
Morgan City Rentals Diesel Jet Pump 6 x 6 Peerless Safe Operating Practices and Procedures.
How would you explain this on the 3394? If Fire Erupts on YOUR Boat If Underway, stop the boat Have everyone who is not wearing a PFD put one on Position.
3.7.6 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Conducting Container Vapor Flaring Operations Before.
SPILL – RESISTANT VACUUM BREAKER ASSEMBLY SVBA TESTIN G.
CAFS On-Line Orientation
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Hydraulic Calculations
Cleaning of the Optical Block, Critical Orifice, and Focusing Nozzle of the Brechtel Model 1710 Mixing CPC.
Augmenting Fire Standpipe Systems
Fire Detection and Suppression Chapter 7 Special Extinguishing Systems.
On-Line CAFS Orientation Montgomery County Fire & Rescue Service Class B Foam Theory and Deployment.
Unit 5 Bench Testing, Maintenance, and Troubleshooting.
Number One In The World For a Reason ® ® Holmatro Hydraulic Rescue Tool What You Need to Know to Maintain your Rescue Tool System © 4/2004 Holmatro.
Proportioning Systems. 69 Proportioning Systems Now you know the benefits and uses of water additives, especially Class A foam. So how do we get the concentrate.
1B-1 Fire Engine Maintenance Unit 1B – Pump Inspections and Maintenance.
Bench Testing, Maintenance, and Troubleshooting.  Identify three primary steps in bench testing a helitorch.  Identify six considerations in maintaining.
Supplied-air regulator Copyright © 2013 by The S.E.A. Group.
CAFS On-Line Orientation
Dennis Sabre Fire Appliances
Powered Air-Purifying PARTICLE Respirator (PAPR) Copyright © 2013 by The S.E.A. Group.
CLASSES OF FIRE Class “A” – combustible materials
Purpose of Standpipe and Hose Systems
Supplied-air regulator Copyright © 2013 by The S.E.A. Group.
FOAM APPLICATION TECHNIQUES
3.2.2 Student Book © 2004 Propane Education & Research CouncilPage Performing DOT Cylinder Evacuation and Vapor Flaring Operations Before DOT cylinder.
AIR COMPRESSORS & STEAM CLEANERS. Pressurized air is produced by an air compressor. Air compressors are used daily in automotive shops. They are used.
SCBA CLEANING Monthly and after use. Use mild detergent (dish soap) or Confidence Plus mixed at ½ ounce per gallon of water. Use a brush if necessary.
Series Operational Training. 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner.
Module C Sprinkler systems (4-20)
Fire Extinguishers SECTION: Tools and Equipment ISSUED: REVISED: ##-####
C L A S #2 Driver Operator Refresher Training. Operating Emergency Vehicles Class #2 Henderson Fire Department Defensive Driver Refresher Training.
Accessories Planned Maintenance. Types l Humidifiers l Air Cleaners l Heat Recovery Ventilators l Condensate Pumps.
Respirator Safety This Training Covers Respirator Inspection User Fit Checks Respirator Cleaning Respirator Storage.
Orientation and Annual Refresher Training
FFII Module A Hillcrest Fire Department © 2001
Section 703 Apparatus Inspection. Procedures The driver/operator should follow a systematic procedure for inspecting apparatus This ensures that all important.
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
PHSAUTOMOTIVESALSPHSAUTOMOTIVESALS DISC BRAKE OVERHAUL.
Managing Hazardous Chemical Waste. What is Hazardous Waste EPA Definition: A material is a hazardous waste if due to its quantity, concentration, physical,
Raw Water System Flush By introducing fresh water into the cooling system, growth of sea life is reduced or eliminated keeping the raw water cooling pipes.
3.1.8 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Conducting Container Vapor Flaring Operations Before.
Life Line. Belay Line Canteens Clean and change water.
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
Irrigation System for Home Landscape Developed by: Dr. Teri Hamlin Georgia Department of Education.
Compressed Air Foam System
IFSTA Chapter 16 Fire Streams
2013Q2.
Foam Equipment & Systems Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
ATP FOAM SYSTEM Engine 438 Ansul / Rockwood Model B2 400 GPM Around The Pump Foam System.
BASIC GAS METAL ARC WELDING
VTCT L3 NAIL TECHNOLOGY STUDIES
Fire Attack and Foam (Fire Fighter I)
Essentials of Fire Fighting
Self-expanding foam system
Small Engine Troubleshooting
Provides a continuous supply of ready to use product on demand
Delivery system for Virazole (Ribravirin)
Flammable and Combustible Liquids
CAFS On-Line Orientation
On-Line CAFS Orientation
BOP FLUID FLUSHING SIMON McMANUS WM CANNING LTD.
FOAM APPLICATION TECHNIQUES HOSTED BY THE Jefferson County Fire and Rescue Training Academy.
Presentation transcript:

Thermo-Gel® POK 5 Gallon System The Thermo-Gel® 5-Gallon Container, Backpack and PRO Nozzle/Eductor System is being provided by the Governor‘s Office of Emergency Services to Department‘s maintaining and staffing OES Engines. This will provide those Department‘s with an added resource for use during fire suppression activities and structure fire protection assignments.

Equipment Description 5-Gallon Container With Pick-up Tube 5-Gallon Container Backpack The System is made of three basic components: The 5-Gallon Container containing Thermo-Gel® Class A Fire Retardant Gel Concentrate; The Backpack carrier; and, the POK Nozzle, Eductor, Supply Line and Pick-up Tube. POK Nozzle with Eductor Supply Line

Equipment Specifications Thermo-Gel® 5-Gallon Container Part # TG200L5 Class A Fire Retardent Gel NFPA 1150 Standards US Forest Service Approved Patents 5,989,446 & 6,245,252 Approximate Coverage: 5,000 Square Feet @ 2% 10,000 Square Feet @ 1%

Equipment Specifications Thermo-Gel® 5-Gallon Container Backpack Part # TG200LBP Shoulder Straps Chest Strap Waist Strap Reflectorized

Equipment Specifications Thermo-Gel® POK Nozzle with Eductor Part # TG20PK Metal 1“ NST Stream or Fog Bale Shut Off Variable Eductor OFF 1% 2% Flush Flow Rate: 20 GPM

Equipment Specifications Supply Line Comes with Nozzle and Pick-up Tube Swivel Connector to Pick-up Tube Screw Connector to Eductor Non-Collapsible Clear for observation of product flow & easy cleaning

Equipment Assembly The 5-Gallon Container with the Gel Concentrate should be well shaken prior to removing the sealed cap. The Pick-up Tube should be inspected to insure that it is clear of any obstructions and for clean and dry conditions. Extreme caution must be taken to avoid the introduction of any moisture into the concentrate. Moisture will cause the concentrate to gel and thicken prematurely and will clog the system. If clear, insert the Pick-up Tube into the container and tighten. Depending on department or engine company preference, these steps can be taken while the 5-Gallon Container is secured within the Backpack.

Equipment Assembly The Thermo-Gel® Backpack system straps should be extended to a comfortable position for donning and the clasps opened. The 5-Gallon Container should be inserted and the retaining strap snapped closed. The Pick-up Tube position should be to the side of the Backpack for ease of Supply Line clearance along the back and under the arm of the fire fighter.

Equipment Assembly The PRO Nozzle Eductor and Supply Line System has fixed screw mechanisms. This requires that the Supply Line be attached either while the eductor is separated from the nozzle, spinning the eductor onto the Supply Line or visa versa, and then spinning the nozzle onto the eductor, or with the eductor attached to the nozzle and twisting the Supply Line onto the eductor. The only swivel connector is located for attachment of the Supply Line to the Pick-Up Tube. Once all connections are made, the system is ready for donning.

Equipment Assembly Don the assembled Backpack and tighten the shoulder, waist, and chest straps for comfortable and secure fit. Thread the nozzle and Supply Line to the appropriate side of the firefighter. There are rings on the shoulder straps to locate clips or carabineers to attach the nozzle by the “D” handle to the Backpack for hands free storage. Select the desired flow rate: OFF, 1%, or 2%. Attach the appropriate water line and charge the system. Using the OFF position will allow the water line to be charged, desired water pressure obtained, and optimum stream or fog pattern established. The eductor can now be set to the required flow percent and gel concentrate will begin to flow through the Pick-up Tube and Supply Line. CAUTION: The FLUSH position may assist with the establishment of concentrate flow but should ONLY be used for short durations and/or to clear possible obstructions in the lines or nozzle. The FLUSH position fully opens the Supply Line orifice, concentrate flows at an increased rate, reduces coverage levels available, and places extremely thickened gel into the nozzle system. Immediately after using the FLUSH position, large amounts of water must be allowed to flow through the nozzle system to remove any highly thickened gel and un-diluted concentrate.

Equipment Operation Eductor 1% FLUSH 2% The various eductor orifices can be seen here. FLUSH 2%

Maintenance - Storage Containers Backpack Sealed Dry area Shaken occasionally 3+ year Shelf-Life In Backpack Backpack With Container Nozzle/Eductor/Supply Line/Pick-up Tube Clean and dry location Storage bag w/ container & backpack

Routine Inspections & Care Check location and condition at beginning of each shift Inventory System and Shake Container once a Week Incorporate System use in monthly training exercises (Eductor in OFF position) Clean and Dry Nozzle and hose system monthly Full nozzle breakdown should only be done by qualified personnel

Clean-up After Use It is EXTREMELY important to thoroughly clean and remove ALL concentrate and gel from the Nozzle, Supply Line, and Pick-up Tube Water and/or Mineral oil works extremely well to clean and flush all equipment parts All parts must be clean and dry An air hose may be used to blow out and thoroughly dry all parts

Troubleshooting Failure to Educt Check Water Flow (20 GPM) Check Water Pressure (75-100 psi at nozzle) Check Eductor Selection (OFF, 1%, 2%) Check Supply Line, Pick-up Tube and connections for tightness and seal Select FLUSH position for 1 to 3 seconds Breakdown system, check for clogging, debris, or dried concentrate in lines/orifices

DO’S AND DON’T DO KEEP NOZZLE, EDUCTOR, AND PICK-UP TUBE CLEAN AND DRY DO COMPLETELY CLEAN SYSTEM AFTER EACH USE DO NOT ALLOW WATER TO ENTER CONCENTRATE CONTAINER DO NOT PREMIX CONCENTRATE IN NON Thermo-Gel® SYSTEMS DO NOT PUT Thermo-Gel® INTO EXISTING ENGINE FOAM TANK SYSTEMS DO NOT MIX Thermo-Gel® AND FOAM APPLICATOR HARDWARE (FOAM AND GEL ARE NOT COMPATIBLE)

923 E. Interstate Avenue Bismarck, North Dakota 58503 (701)258-8208 Fax (701)258-7259 www.thermo-gel.com 24 hour Emergency/EERA/BPA 866-255-8137 U.S. Patents 5,989,446; 6,245,252 Addl Patents Pending