Lambda – The Windowsystem innovative, flexible, practical Total new design addressing the requirements of the European markets.

Slides:



Advertisements
Similar presentations
Exterior Window and Door Frames
Advertisements

Buildings and Structures 1
Contents: Cover
© Copyright REHAU - PIM013e - - Page rehau S mm Window/Door System.
Version 3.2 Version 3.2 Version 3.2 Version 3.2
Assembly Instructions DucoSlide Luxframe Controllable TOP BOTTOM L.H. R.H. Control side FRONT SIDE in open position REAR SIDE in open position 1.
ModICE Modular Integrated Connector Enclosure
Mate Grinder MATE European Dealer Meeting Advantages of Automatic Controlled Punch and Die Grinding More regrinds, accurate material removal Protect.
Product Specification Product overview, details, scope & application.
Re-engineering of current products to ease assembly and integrate Design for Manufacturing and Assembly within the design process A Knowledge Transfer.
Copyrights © ATTEXOR Clinch Systems SA 1 Modules (for integration) This presentation is for internal use of ACS’ exclusive.
typical wood windows in India
 Introduction  Designing of Die Block  Process of making Press Form Points to be Covered PRESS FORM AND RUBBER TECHNOLOGY.
Steering Columns.
Chapter 4: Sheet Metal Forming
Efficient flexibility in room management with SAUTER EY-modulo.
Needle Bearing Product Overview
Chapter 10 Sheet Metal Design. After completing this chapter, you will be able to perform the following: – Start the Autodesk Inventor sheet metal environment.
Why Choose Vinyl? See the benefits of energy-efficient vinyl windows and doors in many different applications.
Architectural CAD I – IM230 Vocabulary. GROUP 3 Vocabulary.
Electrical stations, switch rooms and server rooms
Place Logo Here Go to top Menu: select View / Master / Slide Master / then go under INSERT to place your logo. Delete this block. For enhanced performance.
SFOBB East Span Seismic Safety Project Steve Margaris, Specifications Engineer, Caltrans.
INTER-LAKES BASES PRODUCTS. MODEL B-75 MACHINE BASE B-75 Model with panels and doors.
The AFD-01, part of FIRE END range of steel doors, is an economical flush door set, for most internal or external applications in commercial buildings.
Windows and Doors. Typically once the roofing material has been installed/completed the windows and doors are installed. It’s important to install these.
Update on alignment kit and stave 250 frame M.Gibson (RAL) 1.
Place Logo Here Go to top Menu: select View / Master / Slide Master / then go under INSERT to place your logo. Delete this block. For enhanced performance.
Flat Saw Training. Flat Saw Sizes –Low Horsepower Blade diameters range from 8” (200mm) to 18” (450mm) Power ranges from 4 to 25 horsepower.
Cold Magnetic Shield Update
Anyway Clip Hinges and Baseplates
SYSTEM PRESENTATION. High-end hinged aluminium system for passive houses.
Rapid Prototyping Introduction
MEYER MULTI PALLET HANDLERS. THE PRODUCT 2 DEVELOPING THE TREND 3.
Drilling Interlocked O-Pile Walls with DTH + PPV FINLAND.
TAKE ‘N’ TRAIN ZONEX™ NON-METALLIC TERMINAL ENCLOSURE.
Place Logo Here Go to top Menu: select View / Master / Slide Master / then go under INSERT to place your logo. Delete this block. WHY THE WeatherLok Series.
Product Information Thermosyphon February 2012 Stefan Manglberger Head of Technical Services TiSUN GmbH HERZLICH WILLKOMMEN Welcome | Benvenuti | Bienvenue.
Automated Machining Adv. MMP
Page 1 Lift/sliding door system PremiDoor 88 Pirmasens, February 2013.
Glass Patio 51 Full glass balcony system
Installation Walkthrough Image Guide
Product Presentation BSF70 Folding Door System
Pipe Shop Consulting Planning and Execution of an Automated Pipe Shop
ModICE Modular Integrated Connector Enclosure
MKTG 2016.
Profile systems in steel and stainless steel
Complete domestic solutions
ADVANTAGE BRIDGE/FRAC PLUG S
Design of Distribution Feedbox at LHC P7
Pipe Shop Consulting Planning and Execution of an Automated Pipe Shop
Rapid Prototyping Introduction
Building Construction I Sofia Sebastian 1
Detail Drawings and Assembly Drawings
AQA GCSE 2 Working with timber based materials and fixings
THE CONCEPT OF LIGHT GAUGE STEEL CONSTRUCTION
Building Construction I Sofia Sebastian 1
© 2004 – 2011 PAVAC Industries Inc. All rights reserved
Customer Presentation
ALUMINIUM DOORS & WINDOWS.
Chapter 10 Sheet Metal Design
FS ” Maximum Blade Capacity 9 HP Honda engine Weight – 141Lbs
Comprehensive range of products – Kawneer Aluminium Systems
Custom Switch and Value Added Capabilities
THE CONCEPT OF LIGHT GAUGE STEEL CONSTRUCTION
® Folding, Sliding, and Swing Doors
® Folding, Sliding, and Swing Doors 3750 Series Multi -Slide Doors.
Presentation transcript:

Lambda – The Windowsystem innovative, flexible, practical Total new design addressing the requirements of the European markets

Project „New window series“ 1976German parliament decided upon Energy Conservation Act 1978Introduction of a regulation upon energy-saving heat insulation (Heat Insulation Ordinance) Amendment of the Heat Insulation Ordinance 2002Heat Insulation Ordinance was displaced by the Energy Saving Regulation (EnEV) (1 Feb 2002) 2008Energy Performance Certificate (for buildings) becomes obligatory step- by-step (1 July 2008) 2007Regulation upon energy-saving heat insulation and energy-saving installation (1 Oct 2007)

Series 77 XLSeries 77 LSeries 65 MSeries 57 S Lambda – the Windowsystem

Lambda Modular System  Inner ½ profiles  Glazing beads  Gaskets  (Outer ½ profiles)  Insulating area  Center seal gaskets

Lambda Modular System  Identical components:  Accessories as:  Fittings  Corner-/ T-connectors  Gaskets  Glazing beads  Processing tools  Varying components:  Center seal gaskets  Glazing gaskets  Insulation area  Insert strips

Lambda Modular System  2- and 3-chamber systems  Profile depth 77 mm, 65 mm and 57 mm  Various center seal gaskets  Wide range in U-value due to insert strips and rebate insulation

Frame profiles for series 77L and 65M Profile overview Lambda 77L and 65M

Transoms for series 77L und 65M Profile overview Lambda 77L and 65M

Reinforced and dilatation profiles/corners/glazing from outside Glazing from outside Profile overview Lambda

Outward opening Profile overview Lambda Sash profiles & Outward opening for series 77L and 65M

Frame profiles and transoms for series 57S Profile overview Lambda

Glazing form outside Profile overview Lambda Reinforced and dilatation profiles/glazing from outside

Sash profiles/outward opening for series 57S Outward opening Profile overview Lambda

Profile overview 65MProfile overview 57S

Profile overview Lambda Supplementary profiles for Lambda

Profile overview Lambda Supplementary profiles for Lambda

Profile overview Lambda Opening types also concealed fittings available

Lambda – The Windowsystem innovative, flexible, practical Systematic of numbering

Article number: B Systematic of numbering Lambda 77 XL / 77 L Number group: 803 Lambda 65 M Number group: 806 Lambda 57 S Number group: 809

Series 1.0 (B 510 XXX) Lambda Systematic of numbering Transom profiles Sash profiles Frame profiles Others Artikelnummer: B

Insulating variant 0 Bars without insulating connection sleeves Systematic of numbering insulating variant Example Lambda 77 L: Article number: B

Lambda – The Windowsystem Innovative, flexible, practical Design features

LambdaSeries 1.0 Series 72E  Frame overlap 25 mm  Insulation area 35 mm/ 23 mm  Housing for center seal gasket in PA strips  Profile depth 77 mm/ 65 mm/ 56,5 mm Design features Lambda 57S Frame profiles

LambdaSeries 1.0 Series 72E  Sash glazing rebate 22 mm, drainage 4,5 mm  Double drip feature against water tracking  Contact area of the center seal gasket moved outwards  Profile depth 88mm / 76mm / 67,5mm  Insulation area 35mm/ 23 mm, same as frame Design features Sash profiles

LambdaSeries 1.0 Series 72E - 22 mm height Design features Glazing beads

 Flush with inner glazing gasket  Rebate for PE insulating (77L)  Little nose for snap-in function (transportation lock) Glazing beads Design features

 Sash profile flush with glazing bead  Frame profile 3mm offset to the glazing bead Glazing beads Design features

Lambda Fittings chamber Series 1.0 Series 72E  Fittings chamber same as 1.0 -> compatibility to 1.0 systems is given  Improved turning performance due to combination of new center seal gasket, frame overlap and new locking system  Greater “kissing area” of center seal gasket allows greater tolerances in cutting of frame and sash profile Design features

Fittings: concealed fittings  RAL Approved  Fully clampable  Stainless steel  Sash weight up to 130 kg  Jamb protection on the hinge side (sash to frame gap < 5 mm)  Integrated opening limiter, adjustable opening angle 90°/ 105°

Fittings Tilt-turn sash Rebate gear with safety device

Fittings Tilt-turn sash Rebate gear without safety device corner gear with safety device

Fittings Possible adjustment of tilt-turn windows C B A A Stay-arm adjustment + 3mm / - 1mm Closing pressure (scissors) + 1mm / - 1mm (+/- 0,8) B Side adjustment + 0,6mm / - 0,6mm (+/- 2) C Height adjustment + 1mm / -1,5mm (+2/ -1) All locks + 0,6mm / - 0,6mm

Fittings 160kg fitting

T-joints Accessories Outside clipable automatic sealing Inside as in series 1.0

T-joints T-bracket Gasket strip Sealing compound Sealing at the profile contour Accessories

T-joints Accessories

Fittings Application diagrams

Lambda – The Windowsystem Innovative, flexible, practical Processing

Processing Simple processing  Connection: crimp, punch, drill  Stable inner chamber  Optimized connections  Improved ability of turning  Coatable compound profiles  Easy change of series

Processing  Cutting tolerances +/- 1,5 mm  Improved ability of turning, small sashes, down to 350 mm  Slotted, self-leveling corner cleats: automatic leveling in height for a neat flush mitre, with minimal adjustment required (driving pin/nail home automatically levels profiles)

Processing  Easy to apply T-connectors with integrated gasket  Identical hole pattern for corner und T-connectors  All processing for corner and T-connections can be done by different punching tools as stationary punches, handpunches, multipurpose punches as well as drilling jigs  Reduce number of crimping knives required for the crimping of the frame profiles –> less change in tooling when using different frame geometries  Upgrade kits for several 1.0 punching tools reduce the necessary invest for fabricators who used 1.0  Delivery of mill-finished compound profiles and surface treatment done by the customers possible  Processing tools: stationary punches, hand punches, multipurpose punches and drilling jigs available

Processing: Tools

Processing catalog New Concept:  Bilingual German/English  Reduced text  Simple and easy understandable 3D-pictures Valid for all Lambda series of the modular system:  Lambda 77 L  Lambda 65 M  Lambda 57 S

Processing catalog  Clear symbols  Additional information for e.g. :  articles  tools  drilling diameters

Processing catalog Processing with tools:  (multipurpose punch)  (stationary punch)  (hand punch)  processing done by milling hole 8 x 30 mm

3D-illustration to clarify the assembly Measured processing Clear identification of the validity of the description (illustrated series printed bold) Processing catalog

Combination of 2- and 3-dimensional illustration All texts bilingual Processing catalog

Practical illustration of installation to the building Processing catalog

Illustration how to use the tools with additional information to the hole pattern

Clear identification of possible settings to punch different hole patterns on complex tools (e.g.: punching tool for operation rod) Processing catalog

Lambda – The Windowsystem Innovative, flexible, practical U – values ( U f )

U f - value modular system U-value 2,3 – 2,8U-value 2,0 – 2,5U-value 1,2 – 2,2

U f -value modular system U f - value: series from fabricator U-values: Series to system manufactures Serie72E Serie 1.0 Lambda 77 L ohne E. Lambda 65 M U f BW = 1,4 U f BW = 1,8 U f BW = 2,2 U f BW = 2,6 Lambda 77 XL 1,001,201,401,601,802,002,202,402,602,80 the range of U-values is defined by the range of the delivery program

U f -value modular system series to U-value Series to U-value Serie72E ) Serie 1.0 Lambda 77 L with insulating sleeves Lambda 77 L without insulating sleeves Lambda 65 M Lambda 57 S U f BW = 1,4 U f BW = 1,8U f BW = 2,2 U f BW = 2,6 1,001,201,401,601,802,002,202,402,602,80

U f -value modular system series 77

U f -value calculator (.xls) – profile sections Updated U f -value calculator for Lambda series

U f -value calculator (.xls) – profile sections Updated U w -value calculator for window units of Lambda series

Enlarged selection criteria to the series with different additional options U f -value calculator (.xls) – window element

HUECK TEC LAMBDA 77L: optional settings for specific positions

HUECK TEC After change automatic calculation of all project positions with new settings

HUECK TEC Detailed listing of U-value including all parameters

Software  Training of diverse software houses has been executed and an update of their software including lambda will be possibly available contemporary:  ORGADATA  C-Mol  SYSCAD  MAP  FEBOS

U-values  Insert strips provide minimum U-values with comparable small insulating area  Competitive U-values with small insulating area give advantages in stability compared to competitor designs  Insert strips allow flexible reaction of the customer on differing value requirements