2015 Update to OBC September 17, 2014.

Slides:



Advertisements
Similar presentations
Facilities Management and Design Chapter 4 Safety and Security systems.
Advertisements

Electronic Locking and Exemption Request Form Training
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
2006 Manitoba Building Code (10) & (11) Audibility of Alarm Systems Important Change.
Initiating Devices Manual Fire Alarm Boxes Ionization Smoke Detectors
NFPA 72 - National Fire Alarm Code Chapter 4 - Notification Appliances
NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview
State Fire Marshal Question and Answer Session with the Louisiana Automatic Fire Alarm Association March 19, 1999.
Department of Fire Services Training Division Office of the State Fire Marshal Massachusetts Carbon Monoxide Alarm Requirements.
CURRENT ADA AND ICC COMPLIANCE DATA AN INTRODUCTION TO BOBRICK’S ADA- COMPLIANT PRODUCTS, AS WELL AS BASIC MOUNTING HEIGHTS AND REACH RANGES DOWNLOAD THE.
Proposed Changes to the ADA & ABA Accessibility Guidelines This presentation was prepared by the U.S. Access Board for the ADA Distance Learning 2000 program.
Disability Discrimination Act 1995 The Background Dec 1996 Unlawful to treat disabled less favourablyDec 1996 Unlawful to treat disabled less favourably.
Ted “Smitty” Smith  I have included in the following slides some key sections from each of the codes you will primarily encounter on the test. I recommend.
©LRI ULC S VERIFICATION OF FIRE ALARM SYSTEMS PART # 6 SYSTEM MODIFICATIONS Presentation for CFAA Annual Seminar May 5, 2010.
Vanderbilt University Medical Center Use either the arrows or the “Page Up” and “Page Down” buttons on your computer keyboard to move through the slides.
Emergency Lighting Code Review Presented by Iota Engineering LLC.
January 16, 2014 Brad Keyes, CHSP Changes to the 2014 Acute Care & Critical Access Hospital Manuals on Life Safety Compliance.
Texas Department of Insurance State Fire Marshall’s Office Sixth Report on State University Fire Safety January 2002.
Alarming The Insurance Company The perspective from the Risk Insurance Industry; The most common problems we see, and recommendations to overcome them.
Subpart E Means of Egress.
Retirement Home Regulated under the Retirement Home Act, 2010.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
FALAR Part 3 – Post Construction  Compilation of  Maintenance records of fire protection/life safety equipment  Test records of fire protection/life.
FPF190: Fire Protection Fundamentals FPF190 Fire Protection Fundamentals 1 Code Consultant.
WELCOME DBI & SFFD Meet the Pros October 11, 2007.
Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code, The National.
Rapid Intervention Team & MAYDAY Procedures
Emergency Action Plans
Ontario Building Code Revision effective Jan 1, 2015
EGRESS AND FIRE PROTECTION
Health Facilities Planning Seminar Plan Review Division Irvin J. Poke, AIA, Chief Todd Y. Cordill, NCARB, Assistant Chief Providing for Michigan’s Safety.
© 2012 Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code and the.
2006 Building Code - Overview
1 Canadian Fire Alarm Association The Perspective from a Municipal Building Department Wednesday May 5, 2010 Presented by:Mike Seiling, CET, CBCO, Chief.
© 2008 Delmar, Cengage Learning Property Security, Emergency Response, and Fire Protection Systems Chapter 13.
MEDICAL MARIHUANA ONTARIO BUILDING CODE REVIEW Photo Credit (Obtained on May 22, 2014)
DRAWING ON EXPERIENCE … BUILDING ON STRENGTH Six Storey Wood-Framed Buildings Unique Structural Opportunities & Challenges Kurt Ruhland, P.Eng. Director,
Home and building automation in a mixed-use building Ho-Jin Park ETRI, Korea ISO/IEC JTC1/SC25/WG1-N1535.
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
SECOND UNITS IN BRAMPTON BREB BUSINESS BREAKFAST October 8, 2015.
Facilities and Infrastructure Requirements
City of Ottawa Update to Accessibility Design Standards (ADS) Second Edition released November 2015 Jo-anne Moore, P.Eng. Senior Engineer, Guidelines and.
Work Area Method Level 3 Alterations – Chapter 9 prescribes requirements. 50% of Building Area Rule.
Presented by John Lewandowski and Mike Larabel Inspection, Testing, and Maintenance of Kitchen Hood Systems Michigan Fire Inspectors Society Winter Educational.
Firefighter Emergency Escape Systems New York State Department of Labor Public Employee Safety and Health (PESH)
Training Module for AODA Accessible Customer Service and Integrated Accessibility Standard Regulation For Contractors March 2016 Joint Accessibility Advisory.
Fire Alarm Verification CAN/ULC-S561-03
VisitAble Housing in Ontario: A Municipal Planner’s Perspective March 23, 2016 Tanja Curic, MCIP, RPP Policy Planner City of Waterloo.
International Existing Building Code. Please turn off your phone or set it to vibrate. If answering a call or texting is necessary please step out of.
Ontario Building and Fire Code Overview Presentation for the Downtown Revitalization Committee May 4, 2016 Jack Tosta, Chief Building Official Andrew McPherson,
Carbon Monoxide Detection: Code and Legislation Updates
Fire Protection Systems Chapter 9 IBC 9th Edition Amendments
Accessible Environment
Code of Practice for Fire Safety in New and Existing Community Dwelling Houses Eamon O’ Boyle.
Professional Design and the Building Code ACT, 1992
Proposed Changes to the 2009 International Building & Fire Codes
NICET Fire Alarm Tech Level 1 Practice Test
NICET Fire Alarm Tech Level 1 Practice Test # 4
Fire Alarm Systems for Emergency Operations of Elevators
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
Building and Fire Codes
Electrical Receptacle Testing
2018 Updates May 2018.
General Requirements of NFPA 101
Presented by: Tim Knisely
Hannah Ehresman, Kelsey Russell, Kaitlyn Higgins, Lynette Akai
National Fire Protection Association Update
Fire Alarm Practice Drill # 11 Denver Fire Department Journeyman Installer License Test © Ted Smith 2017.
Denver Fire Depart. License Fire Alarm Practice Test # 12
Presentation transcript:

2015 Update to OBC September 17, 2014

2014 Update package Minor changes to the code: occupancy to occupancy Regulation to regulation Missing words Updated fees for BMEC submissions

Building Code Act Issuance of permits 8. (2)  The chief building official shall issue a permit referred to in subsection (1) unless, (b.1) the Architects Act or the Professional Engineers Act requires that the proposed construction of the building be designed by an architect or a professional engineer or a combination of both and the proposed construction is not so designed;

Voice Communication Housekeeping change to 3.2.4.23.(10) (10)  The voice communication system required by Sentence (7) shall meet the silencing and transmission requirements of Sentences (3) to (5). Previously referenced (6)

January 1, 2015 Multiple changes to the code with respect to increasing Accessibility I have included only those that impact CFAA issues

Referenced Documents NFPA 72-2013 “National Fire Alarm and Signaling Code” added Referenced to Smoke Alarms in 3.2.4.22.(13) and 9.10.19.1.

3.2.4.19.(4) Alert and Alarm Signals Two new additions: (4) … visual signal devices shall be installed in addition to audible signal devices, (e) in a washroom for public use described in Sentence 3.8.2.3.(2), (3), (4) or (6), and (f) in the living space in a suite of residential occupancy in a Group C major occupancy apartment building.

3.2.4.22.(13) Smoke Alarms New sentence: 13)  Smoke alarms described in Sentence (1) shall have a visual signaling component conforming to the requirements in 18.5.3. (Light, Color and Pulse Characteristics) of NFPA 72, “National Fire Alarm and Signaling Code”.

3.8.1.5 Controls Manual pull stations in a Barrier-Free path of travel: Accessible by a person in a wheelchair Operate with a closed fist, max 22.2.N force Mounted a 1200 mm above finished floor Note: Thermostats at 1200 mm and other building controls min 900 mm / max 1100mm

9.10.19.1 Smoke Alarms New sentence: 2)  Smoke alarms described in Sentence (1) shall have a visual signaling component conforming to the requirements in 18.5.3. (Light, Color and Pulse Characteristics) of NFPA 72, “National Fire Alarm and Signaling Code”.

Other Accessibility Changes These items may not directly impact F/A systems For information to clarify why you may see design changes

Areas Requiring Access 3.8.2.1. Old: Entrance storey and all floor areas accessed by an elevator, escalator or lift New: All office and residential buildings exceeding 3 storeys OR 600 m2

Rooftop Amenity Space External rooftop spaces are common amenity areas on new buildings. These must be made accessible. Rooftop spaces for building services are not included.

Residential Suites 3.8.2.1. Old New 10% of units to BF requirements Can be located anywhere in the building New 15% of units to BF requirements Proportioned to 1, 2 and 3+ bedrooms Distributed among storeys

Washrooms 3.8.2.3. Old New BF washrooms OR stalls, only 1/floor # BF washrooms based on height of building # BF stalls as a ration of the # WC

Hotels 3.8.2.4. 10% of suites to be BF (existing) Controls and safety devices in the suite to 3.8.1.5. (new) Suite entrances doors to BF suites have power door operators (new)

Hotels 3.8.2.4. If the hotel has a generator for emergency power Minimum 1 receptacle to be supplied with emergency power The receptacle to be signed EMERGENCY POWER OUTLET

Doors 3.8.3.3. Principle entrance doors to buildings to have power door operators. If a Vestibule occurs, both doors require power door operators Exception for Detention occupancies and Industrial Occupancies (Previously more exceptions)

Doors 3.8.3.3. Power door operators required on: BF washrooms Assembly occupancies within residential buildings Where proximity scanners are used, they must detect a person in a wheelchair

3.8.3.12 Universal Washroom An emergency call system with audible and visual signal devices inside the Barrier-Free washroom Must be different from the building fire alarm (both visual and audible)

-

-

Sliding Door

Doors in series

Washroom Stalls

Ambulatory Washroom

Universal Washroom

Grab Bars

Accessible Urinal

Fire Code Changes Amendments to the Fire Code Retrofit requirements will also have impact on your work.

Permit Requirements Fire Alarm Systems

Scope of Work Maintenance – No Permit Required Repair – Permit Required Upgrade – Permit Required Replace – Permit Required Emergency Repairs – Permit required as above

Maintenance – No Permit To keep the system functioning to original design and installation standards Replacement of defective components with compatible components Defective control panels may be replaced only if the exact replacement panel is available

Repair - Permit Substantial replacement of equipment that will improve the fire alarm performance Replacement of older panels that are no longer available New panels to accommodate newer technology

Repair - Permit Panel from a different manufacturer New components that incorporate newer technology Installation to CAN/ULC-S524 and Verification to CAN/ULC-S537 Professional involvement is necessary where required by the OBC or PEO

Upgrade - Permit Involves changes to the design of the original system Upgrading may be voluntary by the owner Upgrading may be as a result of a Fire Code order May include the addition of new devices, components, panels, zones

Upgrade - Permit May include upgrades necessary for compliance with barrier-free accessibility requirements Installation to CAN/ULC-S524 and Verification to CAN/ULC-S537 Professional involvement is necessary where required by the OBC or PEO

Replace - Permit The complete replacement of a fire alarm system Replacement of a substantial portion of the system Replacement may be voluntary, as a result of a building renovation program or as a result of a Fire Code order

Replace - Permit Installation to CAN/ULC-S524 and Verification to CAN/ULC-S537 Professional involvement is necessary where required by the OBC or PEO

Emergency Repairs Fire alarm systems in occupied buildings that cease to be operational must be repaired immediately. If the scope of work falls under Repair, Upgrade or Replace from above, a permit should be obtained and after the work is completed.

Emergency Repairs Installation to CAN/ULC-S524 and Verification to CAN/ULC-S537 Professional involvement is necessary where required by the OBC or PEO Note: Is notification to the Fire Department required or recommended?