NOISE CONTROLS FOR PLANTS AND MILLS. SOURCE PATH RECEIVER.

Slides:



Advertisements
Similar presentations
ATR Combi & Freighter  Exit.
Advertisements

AMERICAS TOTAL NOISE CONTROL COMPANY Sound pressure is measured in a unit called decibels and is often abbreviated dB. Zero decibels is the lowest sound.
Noise in Road Construction Developed by the Division of Occupational Safety and Health (DOSH) August, 2009.
Making Work Zones Work Better Effective Noise Control During Nighttime Construction.
Please read this before using presentation This presentation is based on content presented at the Mines Safety Roadshow.
Laminite ® Extreme Protection for Extreme Applications.
Postal Responsibility/Contractor responsibility 1.Serial number of fire extinguisher 2.Number found on fire extinguisher and panel 3.Date extinguisher.
HSI PrisecTM Crushers Help to Sell.
R ‘The Customer’s First Choice’ Linatex Lined Bucket Elevator Handling Material:Coal Capacity:200 Tons/Hr Particle Size: mm Ø Water Content:8 -
Receiving, Transportation, Storage & Shipping Practices Getting the Product into and out of the Plant.
2010 Sign Sales Meeting NESHAP Subpart 6H NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLUTANTS.
2013 Management Workshop Georgia Crushed Stone Association Optimize Fine Cone Crushing Circuits Using Automation.
Kolberg-Pioneer, Inc. An Astec Company Kolberg-Pioneer, Inc. an Astec Company.
Senior/Graduate HMA Course HMA Production BATCH PLANTS Construction.
SURFACE NOISE CONTROLS. Source Path Receiver NOISE EXPOSURE CAN BE REDUCED BY:  APPLYING CONTROLS TO THE SOURCE (S)  BLOCKING THE PATH (S)  ENCLOSING.
MAINTENANCE OF TECHNOLOGICAL NOISE CONTROLS. TECHNOLOGICAL NOISE CONTROLS:  ARE DESIGNED AND INSTALLED TO PROTECT YOUR HEARING  MUST BE PROPERLY SELECTED.
E n v i r o n m e n t a l Health & Safety. April 2001Environmental Health & Safety2 What is IPM? Integrated Pest Management (IPM) is the coordinated use.
8-1. Key Sanitation Condition No. 8: No pests in the food processing plant Foodborne illnesses that may be passed on by pests are numerous:  Flies.
Pest Control. 22 Dec 072 What do pests do? Pests can: Contaminate food (droppings  bacteria)* Spoil food by eating part of it Carry disease.
Control of Work Environment Hazards
Production of aggregates. Where does gravel come from Mines – rivers, banks, quarries Rivers – use dragline to mine gravel from river Banks – veins of.
 Review Alpena Biorefinery Hearing Conservation Program  Types of Hearing Protection Devices Employee Safety Training
Industrial Acoustic Sound Enclosures FanAir Company designs and builds Acoustic Sound Enclosures Engineered to each specific application to control noise.
ICE PLUG MONITORING SYSTEM Ice plug is an efficient method of providing isolation on liquid filled (water, heavy water) pipes to perform maintenance and.
March 31st and April 1st, 2009Mile High Industrial and Automation Conference The Challenges in Upgrading Plant Automation for an Existing Wastewater Treatment.
Nordberg LT1213 EASY TRANSPORTATION HIGH CAPACITY.
Architectural CAD I – IM230 Vocabulary. GROUP 3 Vocabulary.
Centurion Scale “temporary install” The scale to be shown is a B-tek Centurion Scale “Flat top” design with a steel deck Platform is 84’x11’ mounted temporary.
The world leader in serving science CQM Coal Quality Manager.
PATCHING ASSOCIATES ACOUSTICAL ENGINEERING LTD Noise Impact Assessment West Can Seal Coating Gravel Pit LSD W5M West of Sundre.
Noise Control A Guide for Workers and Employers. Steps used to solve Noise Control Problems Define the problem Establish a noise reduction target Determine.
Preventing Silicosis in the Mining Environment. 1.Prevention of Silicosis to Improve Mine Workers Health and Quality of Life. 2. Compliance with MSHA.
HFA Specialty, Miscellaneous Equipment and Options.
A procedure for controlling risks 1 st step – to eliminate and identify hazards 2 nd step – to rank the risk associated with the hazards 3 rd step – to.
1. SIVA By Prof. Dr. Attaullah Shah 2 Fine and Coarse aggregates.
SPEECH PRIVACY INTRODUCTION ACOUSTICAL DEMANDS ENCLOSED ROOMS OPEN PLANS SPEECH PRIVACY:  SPEECH PRIVACY DEPENDS ON THE SIGNAL-TO-NOISE RATIO BETWEEN.
Lesson 4 Physical Security - Motion Sensor - Passive Ultrasonic Sensor - Photoelectric System - Ultrasonic - Ultrasonic Motion Sensor - Vibration Sensor.
Noise in Road Construction. What this presentation covers Hearing loss rates and claims facts Noise levels of construction equipment Control methods to.
MNM Fatal Powered Haulage Accident Powered Haulage Accident July 26, 2012 (Montana) July 26, 2012 (Montana) Crushed Stone Operation Crushed Stone.
1-1-Why Maintenance HVAC ? Increases equipment life & reliability Reduces size & scale & number of repairs Lowers maintenance costs through better.
MNM Fatal Machinery Accident Machinery Accident August 5, 2013 (New York) August 5, 2013 (New York) Crushed Stone Mine Crushed Stone Mine Plant.
FEDIAF Code of Practice
ROGERS GROUP, INC.. Rogers Group History Founded 1908, Bloomington, Indiana by Ralph Rogers Grew with nation’s interstate system, infrastructure growth.
GVC3200 Video Conferencing System. Conference Room Setup Prepare below equipment before setup: Display Device (e.g., HDTV), with power adapters GVC3200,
NOISE CONTROLS FOR UNDERGROUND MINING. SOURCE PATH RECEIVER.
Typical Applications Triten Range Of Products. Flat Liners Quarry.
MNM Fatal /14 Fall of Material Accident Fall of Material Accident August 12, 2010 (Nevada) August 12, 2010 (Nevada) Underground Gold Mine Underground.
ENGINE REASSEMBLY Chapter 12 Classroom Manual page 311
Workplace Examinations. Daily Workplace Examinations Who is responsible for making workplace examinations?
MNM Fatal Powered Haulage Powered Haulage September 28, 2004 (Tennessee) September 28, 2004 (Tennessee) Sand & Gravel Operation Sand & Gravel Operation.
Development of a “ Condition Based Preventive Maintenance Action ” for “ Coal Handling Plant of Thermal Power Station.” In the onsite operation phase,
10 PRODUCT SPILLAGE SOLUTION. IMPACT BED ADVANTAGES Protect belt and conveyor truss from impact and vibration. Ensures good spillage control. No replacing.
As you can see, low frequencies are not absorbed as well. This means low frequencies will travel farther. That graph comes from this extremely detailed.
Hierarchy of Hazard Control
We are one of the accredited manufacturers and suppliers of Accoustic Enclosure and Sound Proofing in northern part of India under brand Name of "DDSTHA".
MNM Fatal Powered Haulage Accident Powered Haulage Accident December 17, 2010 (Maryland) December 17, 2010 (Maryland) Crushed Stone Operation Crushed.
Safety Rule #1 Open flames are not allowed without first obtaining a permit. The exception to this rule is during a period of closely supervised instructions,
Limestone Handling System
Low Frequency Noise Ian Reynolds – Project Manager – Wolf Minerals
Pest Management.
NOISE CONTROL TECHNIQUES (ENCLOSURES and ABSORPTION)
Fans & Heaters technical seminar
Making Work Zones Work Better
Module 15 Noise and Vibration
Don’t buy strip curtains – RENT!!
Workplace Examinations
Maintenance.
Main components Nordberg LT - Closed circuit cone crusher plants.
Presentation transcript:

NOISE CONTROLS FOR PLANTS AND MILLS

SOURCE PATH RECEIVER

NOISE EXPOSURE CAN BE REDUCED BY:  APPLYING CONTROLS TO THE SOURCE (S)  BLOCKING THE PATH (S)  ENCLOSING THE RECEIVER  LIMITING THE EXPOSURE TIME

RESILIENT SCREEN DECKING

TREATED HOPPERS & CHUTES

RESILIENT CRUSHER LINER AND FEED PLATE

CHUTE LINERS

INSTALLATION OF CHUTE DAMS

VIBRATION ISOLATION MOUNTS

Barrier Concept Shadow Zone Diffracted Propagated Reflected Noise Source Barrier

ACOUSTICAL BLOCK WALLS

STRIP CURTAIN BARRIERS REQUIRE A 30 TO 50 % OVERLAP

TRACK MOUNTED PANELS

THE FOLLOWING DEVICES HELP TO REDUCE THE AMOUNT OF TIME SPENT IN HIGH NOISE AREAS THEREBY LOWERING NOISE EXPOSURE

CONVEYOR BELTING KEEPS MATERIAL ON THE SCREEN REDUCING CLEAN-UP TIME

SINGLE LUBE POINTS HELP REDUCE EXPOSURE TIME

REMOTE CCTV MONITORING

BEARING SENSORS

BIN LEVEL INDICATOR

MOST OF THESE DEVICES CAN BE MONITORED INSIDE AN OPERATOR’S CONTROL BOOTH

OPERATOR BOOTHS MUST PROVIDE ADEQUATE VISIBILITY

Maintain Your Noise Controls  Screen decking and chutes should be inspected and replaced or repaired during down time if possible  Barriers around mills and crushing equipment should be kept closed  Windows and doors of control booths should be tightly sealed  Remote sensors should be operational

Additional Resources

Your children can whisper to you now, Don’t make them shout at you in the future