Slide 1 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories BMS 524 - “Introduction to Confocal Microscopy and Image Analysis” Purdue.

Slides:



Advertisements
Similar presentations
Fluorescence and Confocal Microscopy
Advertisements

Slide 1 t:/powerpnt/course/lect5nu.ppt J.Paul Robinson - Purdue University Purdue University Cytometry Laboratories Lecture 5 Preparation Techniques for.
Observing Microorganisms Through a Microscope
Slide 1 t:/powerpnt/course/lect4.ppt Purdue University Cytometry Laboratories Lecture 12 Live Cell Imaging Applications in Confocal Microscopy BMS 524.
Lecture 11. Microscopy. Optical or light microscopy involves passing visible light transmitted through or reflected from the sample through a single or.
Microscopy Lecture I.
Elizabeth Merten and Fumio Ohuchi University of Washington, Seattle Department of Materials Science & Engineering.
1. Resolution (R) : separation of close objects, light wavelength NA, numerical aperture 2. Contrast : distinction of objects from background “light field”
© J.Paul Robinson, Purdue University BMS 631 – LECTURE00007.PPT BMS LECTURE 7 Flow Cytometry: Theory Optics - Filter Properties & manipulation.
Slide 1 t:/PowerPoint/confoc/lect1nu.ppt Purdue University Cytometry Laboratories BMS “Introduction to Confocal Microscopy and Image Analysis” Purdue.
Fluorescence microscopy – Principle and practical consideration Hiro Ohkura.
Introduction to Fluorescence Microscopy. Introduction to fluorescence microscopy Fluorescence Widefield Fluorescence microscopes Filters and Dichroics.
Page 1 © J.Paul Robinson, Purdue University BMS Lecture 4 Optical Systems optical geometry; light sources, laser illumination, & other useful.
Immunolabeling & Fluorescent Microscopy Presented by: Sumble Maha Khan ABE Workshop June 13 – 30, 2006.
© J. Paul Robinson, Purdue University BMS 631- Flow Cytometry lecture0003.ppt 1 BMS 602A/631 - Lecture 3 Light and Matter J. Paul Robinson, PhD.
Copyright J. Paul Robinson, Steve Kelley Purdue University Cytometry Laboratories of 29 Slides BMS “Introduction to Confocal Microscopy.
Copyright J. Paul Robinson, Steve Kelley Purdue University Cytometry Laboratories of 29 Slides BMS “Introduction to Confocal Microscopy.
USE AND CARE OF THE MICROSCOPE LECTURE 1. MICROSCOPY u Light Microscopy: any microscope that uses visible light to observe specimens u Compound Light.
Lecture 1 The Principles of Microscopy
 J.Paul Robinson - Purdue University Cytometry Laboratories Slide 1 t:/classes/BMS524/524lect1.ppt BMS “Introduction to Confocal Microscopy.
Microscopy Techniques for Biomaterial Characterization: A Primer Prabhas V. Moghe Lecture 3 September 21, 1999 RU CBE 533 or BME 553; NJIT BME 698.
Page 1 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT BMS 602/631 - LECTURE 8 Flow Cytometry: Theory J. Paul Robinson Professor.
© J.Paul Robinson, Purdue University BMS 631 – Lecture0006c.ppt BMS LECTURE 6 Flow Cytometry: Theory Some of these slides.
Slide 1 t:/classes/BMS524/2002 lectures/524lect2.ppt © J. Paul Robinson - Purdue University Cytometry Laboratories BMS “Introduction to.
Introduction to Microscopy. Objectives Learn to use a compound microscope correctly. Diagram the path of light through a compound microscope. Name major.
Microscope.
 J.Paul Robinson - Purdue University Cytometry Laboratories Slide 1 t:/classes/BMS524/524lect1.ppt 8:44 PM BMS “Introduction to Confocal.
The microscope practical NO (2)
Slide 1 t:/classes/BMS524/524lect1.ppt  2000 J.Paul Robinson - Purdue University Cytometry Laboratories Lecture 1 The Principles of Microscopy BMS 524.
D EDICATED S PECTROPHOTOMETER F OR L OCALIZED T RANSMITTANCE A ND R EFLECTANCE M EASUREMENTS Laetitia ABEL-TIBERINI, Frédéric LEMARQUIS, Michel LEQUIME.
TIRF Total Internal Reflection Fluorescence Microscopy specialized fluorescence microscopy technique specifically images a very thin optical section (50-250nm)
Copyright © 2006 Pearson Education, Inc., publishing as Benjamin Cummings Micro 20 Lab 2- Microscopy.
Microscopy Observing microorganisms. Light microscopy – any microscope that uses visible light.
Tools of the Laboratory: The Microscope
Honors Microbiology: Chapter 3 Microscopy and Staining
Lecture 4 The Principles of Confocal Microscopy: Components of the microscope. BMS “Introduction to Confocal Microscopy and Image Analysis” 1.
BMS 524: Lecture 3 Purdue University Cytometry Laboratories Lecture 4 The Principles of Confocal Microscopy: Components of the microscope. BMS “Introduction.
By: Rob Page and Tara Trovarello
Basic Microscopy and Imaging Methods in Biomedical Engineering Prabhas V. Moghe, Lecturer Rebecca Hughey, Eric Wallenstein, Mingjung Song November 2, 2004.
Epi-illumination is form of Kohler Illumination:
Microscopes Compound Bright-Field Light Microscope
Compound Light Microscope John Kerr, John Guiheen, Nick Johansen, Schuyler Fuchsman.
Slide 1 t:/classes/BMS524/524lect2.ppt © J.Paul Robinson - Purdue University Cytometry Laboratories Lecture 2 The Principles of Microscopy BMS.
Basic Microscopy – An Overview – October 2005 Protistology Course MBL, Woods Hole, MA.
Confocal Laser Scanning Microscopy: general considerations and techniques Simone Bossi.
Flow Cytometry Becton Dickinson Asia Limited Company.
The Microscope.  Spectroscopic Microscope  Light – Compound (Bright field)  Fluorescent  Confocal  Electron- Transmission and scanning.
Non-reflective coating Good quality lenses in a camera reflect very little light and appear dark or slightly purple. A thin coating of a fluoride salt.
Designing a Microscopy Experiment Kurt Thorn, PhD Director, Image from Susanne Rafelski, Marshall lab.
1 Parts of the Microscope Ocular (eyepiece) Interpupillary adjustment Body Arm Coarse adjustment knob Fine focus adjustment knob Stage adjustment knobs.
FROM IMAGES TO ANSWERS Deconvolution of Widefield and Confocal images The growing role of deconvolution NE 2007.
 Bright-field  Dark-field  Phase Contrast  Fluorescence.
Microscopy Dr. Bhavesh Patel Principal V.P. and R.P.T.P. Science College Vallabh Vidyanagar –
Microscopy.
Microscopy Group 2 Cabatit, Mendoza, Ramos, Rodriguez, Tan.
Microscope.
Optical Filters for Life science applications
BMS 632 – Lecture 6 – Optical Filters & light manipulation
BMS “Introduction to Confocal Microscopy and Image Analysis”
Types of Microscopes Light Electron Bright field Dark-field Scanning
Volume 100, Issue 11, Pages (June 2011)
LIGHT MICROSCOPY basic
BMS “Introduction to Confocal Microscopy and Image Analysis”
Types of Microscopes Light Electron Bright field Dark-field Scanning
Flow Cell Injector Tip Fluorescence signals Focused laser beam Sheath
FLUORESCENCE MICROSCOPY
Microscopy.
MICROSCOPES.
Robert Bissonnette  Journal of Investigative Dermatology 
Flow Cell Injector Tip Fluorescence signals Focused laser beam Sheath
Presentation transcript:

Slide 1 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories BMS “Introduction to Confocal Microscopy and Image Analysis” Purdue University Department of Basic Medical Sciences, School of Veterinary Medicine J.Paul Robinson, Ph.D. Professor of Immunopharmacology Director, Purdue University Cytometry Laboratories These slides are intended for use in a lecture series. Copies of the graphics are distributed and students encouraged to take their notes on these graphics. The intent is to have the student NOT try to reproduce the figures, but to LISTEN and UNDERSTAND the material. All material copyright J.Paul Robinson unless otherwise stated, however, the material may be freely used for lectures, tutorials and workshops. It may not be used for any commercial purpose. The text for this course is Pawley “Introduction to Confocal Microscopy”, Plenum Press, 2nd Ed. A number of the ideas and figures in these lecture notes are taken from this text. Lecture 2 The Principles of Microscopy UPDATED October 27, 1998

Slide 2 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Review Microscope Basics Magnification Optical systems

Slide 3 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Microscope Components Fluorescence Microscope Numerical Aperture Refractive Index Aberrations Objectives

Slide 4 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Definitions Refractive Index Aberrations Fluorescence

Slide 5 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Fluorescent Microscope Objective Arc Lamp Emission Filter Excitation Diaphragm Ocular Excitation Filter EPI-Illumination

Slide 6 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Construction of Filters Dielectric filter components Single Optical filter “glue”

Slide 7 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Anti-Reflection Coatings Optical Filter Multiple Elements Coatings are often magnesium fluoride

Slide 8 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Standard Band Pass Filters Transmitted Light White Light Source 630 nm BandPass Filter nm Light

Slide 9 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Standard Long Pass Filters Transmitted Light Light Source 520 nm Long Pass Filter >520 nm Light Transmitted Light Light Source 575 nm Short Pass Filter <575 nm Light Standard Short Pass Filters

Slide 10 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Optical Filters Dichroic Filter/Mirror at 45 deg Reflected light Transmitted LightLight Source 510 LP dichroic Mirror

Slide 11 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Filter Properties Light Transmission %T Wavelength Notch Bandpass

Slide 12 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Refraction Light is “bent” and the resultant colors separate (dispersion). Red is least refracted, violet most refracted. dispersion Short wavelengths are “bent” more than long wavelengths

Slide 13 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Light striking a surface tt ii rr Incident Beam Reflected Beam Transmitted (refracted)Beam

Slide 14 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Properties of thin Lenses f 1 p + 1 q = 1 f f p q Resolution (R) = 0.61 x NA Magnification = q p (lateral) (Rayleigh criterion)

Slide 15 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Microscope Objectives

Slide 16 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Objectives PLAN-APO-40X 1.30 N.A. 160/0.22 Flat field Apochromat Magnification Numerical Tube Coverglass Factor Aperture Length Thickness

Slide 17 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Objectives Limit for smallest resolvable distance d between 2 points is (Rayleigh criterion): d = 1.22  Thus high NUMERICAL APERTURE is critical for high magnification In a medium of refractive index n the wavelength gets shorter:  n This defines a “resel” or “resolution element”

Slide 18 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Numerical Aperture The wider the angle the lens is capable of receiving light at, the greater its resolving power The higher the NA, the shorter the working distance

Slide 19 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Numerical Aperture Resolving power is directly related to numerical aperture. The higher the NA the greater the resolution Resolving power: The ability of an objective to resolve two distinct lines very close together NA =  sin  –(n=the lowest refractive index between the object and first objective element) (hopefully 1) –  is 1/2 the angular aperture of the objective

Slide 20 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Numerical Aperture For a narrow light beam (i.e. closed illumination aperture diaphragm) the finest resolution is (at the brightest point of the visible spectrum i.e. 530 nm)…. NA 2 x NA x 1.00 =  m = 0.53  m With a cone of light filling the entire aperture the theoretical resolution is….. = =

Slide 21 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Object Resolution Example: 40 x 1.3 N.A. objective 2 x NA x 1.3 = 0.20  m = 40 x 0.65 N.A. objective 2 x NA x.65 =  m =

Slide 22 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Microscope Objectives Specimen Coverslip Oil Microscope Objective Stage NA PlanApo

Slide 23 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Refractive Index Objective n=1.52 Specimen Coverslip Oil n=1.33 n = 1.52 n = 1.0 n = 1.5 Wat er n=1.52 Air

Slide 24 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Monochromatic Aberrations –Spherical aberration –Coma –Astigmatism –Flatness of field –Distortion Chromatic Aberrations –Longitudinal aberration –Lateral aberration Sources of Aberrations

Slide 25 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Monochromatic Aberration –Spherical aberration Generated by nonspherical wavefronts produced by the objective, and increased tube length, or inserted objects such as coverslips, immersion oil, etc. Essentially, it is desirable only to use the center part of a lens to avoid this problem. F1F2 F1 Corrected lens

Slide 26 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Monochromatic Aberrations –Coma Coma is when a streaking radial distortion occurs for object points away from the optical axis. It should be noted that most coma is experienced “off axis” and therefore, should be less of a problem in confocal systems. From:Handbook of Biological Confocal Microscopy J.B.Pawley, Plenum Press, NY, 1995, 2nd Ed Fig 12 p117 From:”Handbook of Biological Confocal Microscopy” J.B.Pawley, Plenum Press, NY, 1995, 2nd Ed The figure is not reproduced in this presentation because we do not have permission to place this figure onto a public site. Note: For class use Figure is under box

Slide 27 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Monochromatic Aberrations –Astigmatism Fig 13 p118 If a perfectly symmetrical image field is moved off axis, it becomes either radially or tangentially elongated. From:Handbook of Biological Confocal Microscopy J.B.Pawley, Plenum Press, NY, 1995, 2nd Ed. Fig 13 p118 From:”Handbook of Biological Confocal Microscopy” J.B.Pawley, Plenum Press, NY, 1995, 2nd Ed The figure is not reproduced in this presentation because we do not have permission to place this figure onto a public site. Note: For class use Figure is under box

Slide 28 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Monochromatic Aberrations –Flatness of Field –Distortion Lenses are spherical and since points of a flat image are focused onto a spherical dish, the central and peripheral zones will not be in focus. Complex Achromat and PLANAPOCHROMAT lenses partially solve this problem but at reduced transmission. DISTORTION occurs for objects components out of axis. Most objectives correct to reduce distortion to less than 2% of the radial distance from the axis.

Slide 29 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Useful Facts The intensity of light collected decreases as the square of the magnification The intensity of light increases as the square of the numerical aperture Thus when possible, use low magnification and high NA objectives.

Slide 30 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Fluorescence Microscopes Cannot view fluorescence emission in a single optical plane Generally use light sources of much lower flux than confocal systems Are much cheaper than confocal systems Give high quality photographic images (actual photographs) whereas confocal systems are restricted to small resolution images

Slide 31 t:/powerpnt/confoc/lect2nu.ppt Purdue University Cytometry Laboratories Summary Lecture 2 Properties of optical filters Objectives Numerical Aperture Refractive Index/Refraction Aberrations Fluorescence Microscope - introduction Purdue University Cytometry Laboratories