LAPD Run 2 Results and Notes Terry Tope 3.19.13 1.

Slides:



Advertisements
Similar presentations
Refrigeration Basics 101 By: Eric Nelson.
Advertisements

Antero Punttila Analyzing most typical energy saving measures Energy Efficiency of Steam and Condensate Systems Antero Punttila, Motiva Oy.
Inert Gas Purification Systems
Inert Gas Purification Systems Why do we need them??? Many of the materials used in research and development today are extremely air sensitive, and can.
Proposed Modifications in Boiler Feed Tank By: D K Singhal
Wine Cellar Split System Basics. Definitions Split System – A cooling unit that “splits” the cooling coil and the condenser apart into two remote pieces.
LBNE 35 ton prototype Phase 1 summary Terry Tope Fermi National Accelerator Laboratory All Experimenters’ Meeting – Fermilab – May 19, 2014.
SAFETY, TOOLS & EQUIPMENT, SHOP PRACTICES
Cryogenic discussion and update 30 October 2014Neutrino platform.
Materials Qualification for long drift Liquid Argon TPC Effect of water on electron drift lifetime Plans Material Tests, purging and H20 studies, Purity.
LAr1-ND Conceptual Design Review of Status June 25 Craig Thorn.
LAr1-ND David Montanari Fermi National Accelerator Laboratory CERN – Feb 16, 2014.
Magnet Cooldown Scheme 17 th February 2012 Roy Preece (STFC RAL)
COMMERCIAL REFRIGERATION
Product Introduction.
Oil Pressure Problems What to look for.
Depleted Argon from Underground Sources Henning O. Back – Princeton University For the DarkSide experiment, E-1000 Augustana College – D. Alton FNAL –
Some Work on Liquid Argon Purity at Fermilab f 6/9/2011 S. Pordes TIPP 1.
Fcal upgrade for sLHC: Cryogenics modifications – TE-CRG/ C.Fabre 1 ATLAS FCal Upgrade for sLHC: Modifications to the Calorimeter Cryogenic.
Next Generation OBIGGS: Developments at Phyre Technologies
1 Combustion Oil Fired Equipment. 2 OIL Combustion of oil fired equipment has the same basics of gas. Remember, Oil is a liquid and this must be converted.
Observations on possible factors affecting LAr purity on the 50kton TPC from the viewpoint of the internal walls Alejandro S. Díaz Chemical Engineering.
LAr1-ND Cryogenics Concept David Montanari Neutrino Cryogenics Requirements Meeting 24 September 2014.
Refrigeration Basics 101.
4/5/2005FLARE Cryogenics, RLSchmitt1 Argon Refrigeration Supply Purity.
Some Work on Liquid Argon Purity at Fermilab f 6/9/2011 S. Pordes TIPP 1.
1 A/C Pressure Test and Evacuation. 2 Leak Detection Leak detection must be done after every repair job. It must also be done anytime the appliance can.
Liquid Argon Time Projection Chamber: Purity and Purity Monitoring DAVID GERSTLE – LArTPC – YALE UNIVERSITY/FNAL 31 May 2006 – FNAL Users’ Meeting Materials.
MICE CC Test Status Ruben Carcagno 11/06/13 1. Cooldown Coil Temperature (calculated average in each of 8 coil segments) SC Transition (voltages across.
Materials Qualification for long drift Liquid Argon TPC Effect of water on electron drift lifetime Plans S. Pordes Argon Purity1Integrated R & D Plan Review.
Hans Jostlein, May 24, Large Liquid Argon Purity Demonstration— Phase I: Gas Flushing -What -Why ? -How ? -When ? -Define “Success”
Poster Design & Printing by Genigraphics ® Neutrino Interactions Studying the properties of neutrinos will shed light on the origin of the.
The RPC Closed loop Gas System Slides from Bianco and Guida.
Materials Qualification for long drift Liquid Argon TPC Effect of water on electron drift lifetime Plans Material Tests, purging and H20 studies, Purity.
S. Pordes - FNAL May 13th Purity Monitor - Description and Experience at Fermilab Production of Clean Argon - Description of Filtering System and.
Johan Bremer, 22th-26th September 2008 Cryogenics Operations 2008, CERN, Geneva, Switzerland 1 CRYOGENICS OPERATIONS 2008 Organized by CERN Safety aspects.
Luke or MTS Q anode. MOBY DICK  Purpose of Moby Dick:  Can we even get to ~10 ppb O 2 and H 2 O?  What other things in Moby will cause loss of LAr.
Neutrino Cryogenics Requirements Meeting 25/09/2014 Day 1 review.
Preliminary results on Copper filters, with FLIC test chamber F. Pietropaolo, A. Zani, M. Meli CENF General Meeting – 22/10/2015.
What is a Cryocar? It is a liquid nitrogen powered vehicle. Propulsion systems are cryogenic heat engines in which a cryogenic substance is used as a.
1/26/2009 S. Pordes LAr R & D Briefing 1 Liquid Argon presents prospect of continuously live Imaging Calorimeter C. Rubbia.
Cryogenics Fabrication Plans & Constraints David Montanari (on behalf of the CERN Neutrino Cryogenic Group) ProtoDUNEs Meeting Feb 23, 2016.
Materials Qualification for long drift Liquid Argon TPC Effect of water on electron drift lifetime Plans Material Tests, purging and H20 studies, Purity.
35ton and LAPD cryostats and future DUNE detector development.
Second run with the Copper filter WA104 technical meeting – 23/03/2016.
A two-stage system for the future cooling system.
Microboone Cryostat Mike Zuckerbrot Fermilab. Basic Overview of Microboone  Microboone’s 2 Phases of Operation  Phase 1 operations ran from about December.
35 Ton LAr Impurity Distribution Measurements and CFD simulation Erik Voirin – Fermilab – Thermal and Fluids Engineering Group / Engineering.
AT-ECR/C.FabreMay 31, 2007 Cryogenics for Liquid Argon Calorimeters Caroline Fabre on behalf of the ATLAS Liquid Argon Cryogenics Collaboration.
Methane Update and Run Plan Ben Jones. Configuration 8 inch PMT with TPB plate - 8” from alpha source - Now includes magnetic shield - 2 inch PMT without.
1 Cary Kendziora Fermi National Laboratory Cary Kendziora Fermi National Laboratory CEC-ICMC 2013 Anchorage Alaska – June, 2012.
Neutrino Platform Proximity Cryogenics Functional Design M.Chalifour 14/04/2016 M. Chalifour - TE/CRG-CI 2.
ProtoDUNE Single Phase (NP-04) P&ID David Montanari (on behalf of Mark A, Johan B, Michel C, Joaquim C, Kevin H) CERN Neutrino Platform General Meeting.
Chapter 16 Thermal Energy and Heat
Installation of the T600 at Fermilab
Overview of the Long-Baseline Neutrino Facility Cryogenic System
Proximity Cryogenics P&IDs Meeting
protoDUNE – single-phase Instrumentation - Gas Analyzers
Proximity Cryogenics P&IDs meeting
Instrumentation Used in LAPD and 35T Runs (Dune DocDB 1759)
David Montanari / Johan Bremer Jun 11, 2015 Rev. 1
Follow-up of the tests with the copper filter
CRYOGENICS OPERATIONS 2008 Organized by CERN
Refrigeration Basics By: Mohamed Iqbal Pallipurath.
Cryogenics – The Basics
Presentation transcript:

LAPD Run 2 Results and Notes Terry Tope

What is the Liquid Argon Purity Demonstrator? 30 ton liquid argon tank (5,875 gal, 22,240 L) Cannot be evacuated 1 st run was Winter – Achieved 3+ ms lifetime – Only filled 1/3 full due to commissioning caution 2 nd run under way now (started late December) – Tank is “full” – Includes “Long Bo” TPC with 2 meter drift – Has again achieved and sustained 3+ ms lifetime 2

3 10 feet Purity monitors Room temperature feed thrus Foam insulation GAr Mole sieve Cu O 2 filter LAr pump Condenser Long Bo TPC LAr

Filter Regeneration Copper based oxygen filter External heaters warm a mix of hydrogen and argon gas to 200 C Hydrogen combines with oxygen to create water Hydrogen in Argon at levels > 2.7% is considered flammable by commercial gas suppliers Reaction is exothermic such that the filter self heats If 250 C is exceeded filter may sinter and Cu surface area and thus filter capacity is reduced For the 80 liter LAPD filter size 0.3% H2 in Ar created self heating at a rate of 10 C/hr 2.5% H2 in Ar led to runaway self heating H2 should be slowly bled into the primary argon flow while filter temperature is monitored Filter is evacuated while it cools 4

Filter Regeneration Molecular sieve (4A) External heaters warm inert gas to 200 C If nitrogen is used for regeneration its very hard to remove such that the mole sieve will outgas nitrogen into a purge argon gas stream Filter is also evacuated while it cools 5

Purge from Air Room temperature argon gas injected into tank bottom pushes less dense air out the top After the argon piston pushes the majority of air out of the tank this becomes a perfect mixing purge 5 ft 3 /min argon gas injection rate – 3.8 ft/hr argon piston rise rate – 2.9 hrs per volume change – 7.5 total volume changes O % to 6 ppm N % to 18 ppm H 2 O – 200 ppm to 1.2 ppm Tank was actively purged with breathable air during the 9 months between runs 1 and 2 to protect from ambient moisture 6

Purge from Air How important is the purge? Due to the 841x mass difference between warm argon gas and liquid argon – 6 ppm O 2 vapor contamination adds 7 ppb O 2 to the equivalent liquid volume – 18 ppm N 2 vapor contamination adds 21 ppb Unlike O 2 /N 2, H 2 O outgases “forever” Must purge out piping and other “dead” volumes attached to the tank that can’t be evacuated 7

Plot of purge from Air to Argon 8 Plot by Benton Pahlka

Gas Recirculation A bellows pump pulls room temperature argon gas from the feed thrus at the top of the tank Gas is pumped thru the mole sieve and oxygen filters at a rate of a volume change every 3.4 hours. Same filters/piping used for liquid filtration Gas recirculation phase is a useful debugging phase prior to liquid introduction – Find leaks missed by other forms of leak checking – Verify that filters are properly regenerated Commercial gas analyzers are a necessary diagnostic. – A leak was found in the system when the recirculation hung up at 520 ppb O2 9

Gas Recirculation Gas recirculation ran for 77 volume changes which is about 1 week O 2 was reduced to 20 ppb (still falling) H 2 O reduced to ~667 ppb and stable H 2 O outgases “forever” and outgassing rate eventually matches filtration rate N 2 is not filtered – its only reduced by the slow dilution of argon makeup gas that replaces gas sent to the commercial analyzers N 2 was reduced to 13 ppm 10

11

Liquid Fill LAPD was filled with LAr from the DZER0 calorimeters in 4 trailer loads Important to verify supply LAr contamination prior to system introduction – First 5,000 gallon LAr trailer supplied by commercial vendor for LAPD run 1 was rejected – It did not meet PO spec and would have led to an impractical # of filter regenerations – DZERO LAr contamination (very good) < 200 ppb O 2 8 PPM N 2 Unable to measure H 2 O in liquid – answer is always zero 12

Liquid Fill Particulate filters to protect tank very important Upon entry into LAPD tank after Run 1 shocked by amount of particulate in tank – Not a problem for electron lifetime but may be attracted to HV surfaces This was despite careful pipe cleaning Also recommend pressurizing and then blowing down piping to blast out particulate prior to closure of piping sections First Run 2 fill attempt revealed a Kimwipe left in the piping – must be vigilant Also 1 st LAr trailer load plugged fill line particulate filter 13

Particulate in Tank After Run 1 14 Purity monitors Purge distribution piping

Extraction from Cold Tank Prior to the start of liquid recirculation a translating RTD device was removed from the tank liquid (Archimedes’ principle) – Tank was depressurized to ambient pressure – Four inch diameter aperture opened – Tank boil off gas vented from aperture into room during device removal – Boil off gas should intercept most contamination – O 2 in liquid increased from 6 to 26 ppb after extraction Conclude devices can be reasonably extracted cold 15

Liquid Recirculation Contamination at the start of liquid recirculation – Liquid phase 30 ppb O 2 8 PPM N 2 Recirculation started at 2.42 vol change/day 1 millisecond electron lifetime achieved after 6.6 volume changes Stabilized at 4 ms after 60 volume changes Reduction of pumping speed did not reduce lifetime 6 weeks of successful pumped liquid purification demonstrated 16

sd 17

18 Stabilized at 4 ms after 60 volume changes 6 week run

vol/day 1.22 vol/day 0.69 vol/day Pump off Pump flow rate reduction did not reduce lifetime

20 < 1 ms after 12 hours Pump off – “dirty” condensed LAr returns to tank unfiltered Data for estimating outgassing

Warm Feed Thrus For most of the 2 nd run the warm feed thrus have been stagnant Sampling at the TPC signal feed thru – 582 ppb O2 – 2,400 ppb H2O – Sample flow rate gives 300 vol change/day Despite this gross contamination, liquid a few feet below is ultra clean Conclude boil off gas intercepts contaminants diffusing out of signal feed thru risers 21

22 GAr Mole sieve Cu O 2 filter LAr pump Condenser 582 ppb O2 2,400 ppb H2O 33 ppb O2 16 ppb H2O O2 < ppb based on measured lifetime

Warm Feed Thrus Used a bellows pump to pull gas thru all of the warm feed thrus and send the gas to the condenser Sampling at the TPC signal feed thru during pumping – 582 ppb O2 reduced to 2 ppb – 2,400 ppb H2O reduced to 750 ppb – Bellows pump gives 3,500 vol change/day Actively pulling contamination from risers did NOT improve liquid electron lifetime Conclude (again) boil off gas intercepts contaminants diffusing out of signal feed thru risers 23

24 GAr Mole sieve Cu O 2 filter LAr pump Condenser Bellows Pump 2 ppb O2 750 ppb H2O 33 ppb O2 16 ppb H2O O2 < ppb based on measured lifetime

Bulk Liquid Temperature 25 Plot and measurements by Alan Hahn 0.1 Kelvin increment Tank bottom Liquid surface 5 inch increment

Vapor Temperature Gradient 26 Plot and measurements by Alan Hahn 60 Kelvin dT in vapor 20 inches Detector components will see large temperature gradients in the vapor during the cryostat fill (or empty) Half full tank

Future Work Filter capacity tests – During 1 st run filters saturated in 2 weeks – During 2 nd run filters did not saturate after 6 weeks – Injection of contaminants Modeling of contamination inside of tank Thanks to the many many people who have supported LAPD 27