What is Flow Cytometry? Flow Cytometry uic Introduction to Flow Cytometry IGC Workshop Multicolor Flow Cytometry IGC – April 28, 2010 Adapted from Holden.

Slides:



Advertisements
Similar presentations
Building a Panel Select markers Select conjugates Method to build panel performance criteria.
Advertisements

Flow Cytometry What is Flow Cytometry? Introduction to Flow Cytometry
DNA cell cycle analysis is affected both by the type of instrument used and the binding dye Ryan Duggan and David Leclerc The University of Chicago Flow.
1 2 3 * Flow = cells in motion * Cyto = cell * Metry = measure * Measuring properties of cells while in a fluid stream * Flow Sorting * Sorting (separating)
What is Flow Cytometry? Introduction to Flow Cytometry
Design and optimization of multicolor panels Holden T. Maecker.
Steps to Success with Multicolor Flow Cytometry
Panel Design: “Multi-Sizing” Your Multi-Color
Issues in Multicolor Flow Cytometry: Beyond 6 Colors
Instrument QC and Qualification
Standard AriaII Cy5.5 Láser violeta
Quality Control in Immunophenotyping Dr. N. Varma Prof. & Head – Hematology Post Graduate Institute of Medical Education & Research (PGIMER), Chandigarh.
Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.
ACQUISITION RATES EFFECT ON MULTIPARAMETRIC RARE EVENT ANALYSIS : AN INSTRUMENT COMPARISON John Tigges, Vasilis Toxavidis, Heidi Mariani Beth Israel Deaconess.
750LP 780/60 710/ LP 710/50 530/30 Blue Laser (488nm, 100mW)Red laser (644nm,100mW) Alexa 700 APC Cy7 APC-Alexa750 Alexa 488 FITC CFSE SYTOX Green.
Advancements in FACS analyzers optical design leads to greater functionality and a smaller footprint. INTRODUCTION In the past decade, instrumentation.
COMPENSATION By: Ronald Mathieu. Compensation Why do we need compensation? –1) Because of long emission spectrum of dyes like FITC and PE.
Introducing a new instrument to the Cancer Center Flow Cytometry Core Facility: The LSR II by Becton Dickinson.
Analysis and Sorting of T reg Cells on the FACSAria John Daley Director of Flow Cytometry Hematologic Neoplasia Dana-Farber Cancer Institute Harvard Medical.
Compensation The process of correcting for flourescence crosstalk
Flow Cytometry. Allows For Detection Of Surface Markers Of Cells Allows For Detection Of Intracellular Factors Allows Detection Of Secreted Factors By.
Principles of Flow Cytometry
Introduction to the Principles of Flow Cytometry
FACSCalibur Training General Information The FACSCalibur is a useful analysis tool. The instrument has 2 lasers- 488 (primary) and 633 (secondary) that.
Introduction to the LSR II and FACSDiva 6.0 Software
Introduction to Flow Cytometry IGC Workshop April 27-30, 2010 General Programme TimeTutorialRoomSpeaker Day 1 9h30-10h45Fundamentals of Flow CytometryIoniansRui.
Basics of Flow Cytometry Holden Maecker. Outline Definitions, what can be measured by flow cytometry Fluidics: Sheath and sample streams, flow cells,
These particles have something in common
2014 Duke CFAR Flow Cytometry Workshop Data Standards and Annotation.
Introduction to Flow Cytometry
Instrument QC and Qualification
Intracellular Cytokine Staining (ICS) Flow Cytometry Assay 1 Kent J. Weinhold, Duke CFAR Director November 6th, 2013 CFAR Director’s Meeting Flow Cytometry.
What is Flow Cytometry? Flow Cytometry uic Introduction to Flow Cytometry IGC Workshop IGC – Nov 12, 2009 Cell Sorting.
Supplemental Figure 1 A. EpCAM Gating Strategy Top Row: Histogram showing unstained BT474 cells with low fluorescent intensity of the EpCAM specific PE.
Flourescence Activated Cell Sorting
Practical molecular biology PD Dr. Alexei Gratchev Prof. Dr. Julia Kzhyshkowska Prof. Dr. Wolfgang Kaminski.
Cell viability studies Sepideh Khoshnevis. The Goal To distinguish live cells from dead and apoptotic cells in order to calculate the the percentage of.
2013 Duke CFAR Flow Cytometry Workshop Data Standards and Annotation.
Polychromatic Flow Cytometry and Flow Applications Basic Concepts Kevin P. Weller Technical Applications Specialist.
Flow Cytometry at Boston University Medical Campus Introduction to some methods that we offer Yan Deng (X4-5225), Gerald Denis (X4-1371),
Introduction To Flow Cytometry By Noha Kamel. Flow cytometry is a method of measuring multiple physical and chemical characteristics of particles by optical.
Basic Principles in Flow Cytometry
Immunology Assays for Clinical Research Yan Ge, Ph.D. University of Virginia
Basic Principles, Instrumentation, and Practices
Laser Flow Cytometry Forward Scatter indicates size Forward Scatter.
Flow Cytometry Basic Training. What Is Flow Cytometry? Flow ~ cells in motion Cyto ~ cell Metry ~ measure Measuring properties of cells while in a fluid.
Flow Cytometry. Applications FRET- protein interaction Membrane protein expression Intracellular protein expression Cell viability Ca 2+
Flow Cytometry and its Applications
Multi-parameter Flow Cytometry: available dyes and combined usage Martin R. Goodier Department of Immunology Imperial College London.
Cytometry tutorial: The impact of adjusting PMT voltages on spillover and compensation Thomas Myles Ashhurst1,2,3, Adrian Lloyd Smith3,4 1Viral Immunopathology.
Fluorescence and Fluorochromes Peter O’Toole Tel:
Fluorescence and Fluorochromes Peter O’Toole Tel:
Multicolor Flow Cytometry: Optimizing Performance for Expanding Colors into High Parameter DATA collection How we are going to do this, we have the talks.
Cytometry tutorial: The impact of adjusting PMT voltages on spillover and compensation Thomas Myles Ashhurst1,2,3, Adrian Lloyd Smith3,4 1Viral Immunopathology.
FACSCalibur Training General Information
Cancer Center Building Rm. 401
بسم الله الرحمن الرحیم.
Flow Cytometry Halima Moncrieffe, University College London, UK IL-17
Flowcytometry.
TRENDS IN LABORATORY TESTING
Default LSR II Configuration BLUE 488nm PerCP, PerCP-Cy5.5, PE-Cy5
Forensic Flow Cytometry
Core Facility Operator
Figure 2 Percentage of CD19+/CD34+ cells with decreased CD81 median fluorescence intensity (MFI;
COMPENSATION + FITC - PE - + PE - FITC - FITC detector FITC PE
UV laser fluorophore options Fortessa HCI 5 Laser FACSAria Cell Sorter
Spectral Flow Cytometry
Optical measurement.
The Art of Flow Cytometry
1. Use the brightest fluorophores available. Brightness Expression
Presentation transcript:

What is Flow Cytometry? Flow Cytometry uic Introduction to Flow Cytometry IGC Workshop Multicolor Flow Cytometry IGC – April 28, 2010 Adapted from Holden and Trotter (Winter 2006) “Selecting Reagents for Multicolor Flow Cytometry” BD Hotlines newsletter, 11:

Outline Know Your Instrument Optical Layout (lasers and filters) Choosing the right fluorochromes Staining Index Spillover Compensation Color Specificities and Tandem Dyes Rules for Multicolor Analysis

Know Your Instrument

Reagent Selection starts with Instrument Configuration Lasers Detectors and respective filters Analyzers Cell Sorters FACSCalibur FACScan MoFlo FACSAria CyAn ADP

Know Your Instrument (FACScan) FACScan Optical Configuration /30585/42 650LP FL1FL2FL3 GFP FITC Alexa488 CFSE PE PI Cy3 PI PE-Cy5 PE-Cy7 PerCP PerCP-Cy5.5 7AAD PE-Alexa610 Typical Fluorochromes 488 nm

Know Your Instrument (FACSCalibur) FACSCalibur Optical Configuration Typical Fluorochromes /30585/42 670LP FL1FL2FL3 488 nm 633 nm /16 FL4 APC Cy5 Alexa647 GFP FITC Alexa488 CFSE PE PI Cy3 PI PE-Cy5 PE-Cy7 PerCP PerCP-Cy5.5 7AAD PE-Alexa610

Know Your Instrument (CyAn ADP) CyAn ADP Optical Configuration GFP FITC Alexa488 CFSE PE PI PI PE-Cy5 PerCP PerCP-Cy5.5 Typical Fluorochromes 405 nm 642 nm APC Cy5 Alexa nm / Alexa 430 AmCyan Pacific Orange DAPI Alexa 405 Pacific Blue PI PE-Texas Red PE-Alexa 610 PE-Cy7 APC-Cy7 APC-H7 Alexa 700* 530/40 575/25613/20680/30750LP 665/20 FL1FL2FL3FL4FL5 APC (FL8) APC-Cy7 (FL9) Violet 1 (FL6) Violet 2 (FL7)

Know Your Instrument (FACSAria) FACSAria Optical Configuration GFP FITC Alexa488 CFSE PE PI PI PE-Cy5 PerCP PerCP-Cy5.5 Typical Fluorochromes 407 nm 633 nm APC Cy5 Alexa nm /40 DAPI Alexa FITC PE PE-Texas Red PerCP-Cy5.5 PE-Cy APC APC-Cy Alexa 430 AmCyan Pacific Orange DAPI Alexa 405 Pacific Blue PI PE-Texas Red PE-Alexa 610 PE-Cy7 APC-Cy7 APC-H7 Alexa 700* 530/30 585/42616/23695/40780/60 660/20

SSC FITC PE PE-Cy75 #1 #2 #3 #4 #5 #6 #7 #8 #9 Blue Red 488/10 530/40 585/40 616/26 95/5BS 555DLP 610DLP 645DLP PE-TxRed 795/50 670/40 APC Know Your Instrument (MoFlo) MoFlo Optical Configuration H-Blue H-Red UV 670/ DCLP D405/30 Yellow mCherry 616/26

Choosing The Right Fluorochromes

Fluorochromes (Stain Index) Brightest Fluorochrome = Highest Stain Index W2 W1 D Stain Index (SI) =D/W

Fluorochromes (Stain Index) Freshly isolated lymphocytes, stained with anti-human CD3 antibodies conjugated with various fluorochromes

Fluorochromes (Choose the brightest) Stain Index of various anti-CD4 fluorochrome conjugates measured on a BD LSR II

Spillover (Minimize spillover) A single fluorochrome can be detected in more than one channel Spectral OverlapCorrecting overlap

A488 true = A488 measured - % PE true PE true = PE measured - % A488 true 0 %5 %10 %15 %20 %30 % Compensation Compensation is a mathematical subtraction to correct spectral overlap Alexa488 PE A488 true = A488 measured - % 1

Colors and Antibody Specificities (Reserve bright labels for dim antibodies) Single Stain Controls CD4-PE Fluorescence CD25-PE Fluorescence CD4-Alexa488 Fluorescence CD25-Alexa488 Fluorescence Single Stain Controls CD25-Alexa488 Fluorescence

Sample CD25-PE Fluorescence CD4-Alexa488 Fluorescence Single Stain Controls CD4-Alexa488 Fluorescence CD25-PE Fluorescence Colors and Antibody Specificities (Avoid spillover of bright cells into detectors of dim signals) CD4-Cy5 Fluorescence CD25-PE Fluorescence

Tandem Dyes Watch out for degradation APC Fluorescence PE-Cy5 Fluorescence TIME PE-Cy5 PE-Cy7APC-Cy7APC-H7 APC- 30% PE-Cy5APC- 40% PE-Cy5APC-50% PE-Cy5

Rules for choosing the right fluorochromes

“Rules” for selecting Multicolor Panel taken from BD Biosciences Rule 1: Choose the brightest set of fluorochromes for your particular instrument configuration. Rule 2: Choose fluorochromes so as to minimize the potential for spillover. Rule 3: Reserve the brightest fluorochromes for “dim” antibodies, and vice versa. Rule 4: Avoid spillover from bright cell populations into detectors requiring high sensitivity for those populations. Rule 5: Take steps to avoid tandem dye degradation, and consider its impact upon results.

Recommended Multicor Panel 5-color6-color8-color10-color FITC or Alexa 488 PE PE-Texas Red or PE-Alexa 610 PerCP-Cy5.5 PE-Cy7 APC, Alexa 647 or Cy5 Alexa 700 APC-Cy7 AmCyan Pacific Blue Fluorochrome choices for 5 or more colors (Recommended by BD)

Recommended Multicor Panel 5-color6-color8-color10-color FITC or Alexa 488 PE PE-Texas Red or PE-Alexa 610 PerCP-Cy5.5 or PerCP PE-Cy7 APC, Alexa 647 or Cy5 Alexa 700 APC-Cy7 AmCyan Pacific Blue Fluorochrome choices for 5 or more colors (Recommended by IGC)

What is Flow Cytometry? Flow Cytometry uic Introduction to Flow Cytometry IGC Workshop Multicolor Flow Cytometry (end) IGC – April 28, 2010 Adapted from Holden and Trotter (Winter 2006) “Selecting Reagents for Multicolor Flow Cytometry” BD Hotlines newsletter, 11: