Airflow and BSC Biosafety and Biosecurity Awareness Training

Slides:



Advertisements
Similar presentations
Biological Hazards Routes of Entry
Advertisements

PowerPoint ® Presentation Chapter 14 Homeland Security Homeland Security Building Layout Specific CBR Attack Prevention Recommendations Securing Outdoor-
ASEPTIC TECHNIQUE. PERSONAL PROTECTIVE EQUIPMENT includes: Eye protection Gloves Masks Gowns Sterile technique is employed to prevent contamination of.
Containment Equipment and Facilities. Biocontainment The principle of holding or being capable of holding or including within a fixed limit or area The.
Biosafety in Microbiologic and Biomedical Laboratories The University of Texas at Tyler IACUC Education and Training *Note: Content not specific to UT.
Working Safely In Your Biological Safety Cabinet
Laboratory Orientation and Safety. Prevention of physical injuries and laboratory acquired infections with zoonotic disease agents Laboratory safety is.
Tulane University - Office of Environmental Health & Safety (OEHS) LABORATORY VENTILATION FOR TULANE LABORATORY EMPLOYEES January, 2005.
BIOHAZRD A biological agent, such as an infectious microorganism, that constitutes a threat to humans or to the environment, especially one produced in.
Chemical Fume hood or Biosafety Cabinet
Aishah Hazlina Md.Dean Jurutera Mekanikal
Biocontainment Practices Inside the Animal Lab
Fume Hoods. Objectives Overview of fume hoods Types of fume hoods Fume hood design definitions Fume hood operating performance and testing Sound work.
CDC/NIH Vertebrate Animal Biosafety Level Criteria ► For all Animal Biosafety Levels (1 - 4)  IACUC Approval  Authorized access to facilities  Animal.
Patient Safety Monitoring in International Laboratories (SMILE) 1 Biosafety in the Clinical Laboratory A SMILE Presentation.
Engineering Controls and Laboratory Design Session 4 Laboratory Safety Training.
Break Out Session 3: Group A: Ventilation and Air Quality Chris Cosgrove, Cosgrove FDS, Inc.
Laboratory Ventilation. 2 Types of Laboratory Hoods  Constant Volume  Conventional  By-Pass  Auxiliary-Air  Reduced Air Volume  Variable Volume.
Laboratory Fume Hoods In accordance with Title 8 CCR Section , Ventilation Requirements for Laboratory-Type Hood Operations. California State University.
World Health Organization
Laboratory Safety-Fume Hoods 29 CFR Laboratory Safety Standard.
Zettl Group Safety Talk ~Fume Hoods~ 09/28/06 Takashi Ikuno.
The Campaign for McMaster University Information Guide to Fume Hoods Facility Services (ext )
Incident Discussion 2-mercaptoethanol. Incident Summary Bottle of 2-Mercaptoethanol (Link to MSDS) placed in Class II A2 biosafety cabinet in xx-xxx after.
LOCAL EXHAUST VENTILATION …study of the principles associated with proper application of local exhaust ventilation (LEV) for control of airborne contaminants.
1 FUME HOOD SAFETY Environmental Energy Technologies Division Safety Topic July 12, 2012.
Prepared by Farid Khalaf.  Protect the worker.  Protect the sample being analyzed.  Protect the environment.
Chemical Fume Hood  A type of local ventilation device that is designed to limit the user's exposure to hazardous or noxious fumes, vapors or dusts.
 Molecular Laboratory must have an ongoing Bio-safety SOP and also quality improvement program to monitor and evaluate objectively and systematically.
Spray Finishing Operations/Spray Booth March 9, 2009.
Industrial Ventilation - A major control measure Dr. AA, UTM.
What is Program Management?
Documentation Management Biosafety and Biosecurity Awareness Training For Afghan and Pakistani Bioscientists January 12-14, 2010 SAND No P Sandia.
TRI MARTIANA.  A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants such as dust, fumes,
LABORATORY VENTILATION
A Rational and Attainable Approach to Successfully Implementing Biosafety in Laboratory Settings Worldwide. Anticipating Biosecurity Challenges of the.
Personal Protective Equipment Biosafety and Biosecurity Awareness Training For Afghan and Pakistani Bioscientists January 12-14, 2010 SAND No P.
Biosafety Recommendations for Laboratory Testing for TB
This course has been supported by the President’s Emergency Plan for AIDS Relief (PEPFAR) through Centers for Disease Control &Prevention (CDC) under the.
General Requirements for a BSL-3/4 Laboratory
Introduction to Biohazards: Risk Management
Discuss the major characteristics of the four Biosafety Levels. Define “Risk Group” and give an example of each. Discuss how Risk Groups are used in conjunction.
Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy’s National Nuclear.
Material Control and Accountability SAND No C Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company,
Sterile Products Lab PHT 434
Bio-safety Cabinet Dr Fadhl M Alakwaa. Agenda What is bio safety cabinet (BSC)? BSC risks BSC Components. What is bio safety levels? Types of bio safety.
Control of Bioaerosols. Concentrations in Air Concentrations of indoor bacteria range from
By: Jim Kibby Fouling and ROI Tools (Return On Investment)
Biological Safety Cabinets and Disinfection Sean Fitzgerald Harvard Biosafety.
Containment Equipment and NSF 49. Containment – BMBL Primary containment is the protection of personnel and the immediate lab environment from exposure.
Control of Bioaerosols. Concentrations in Air Concentrations of indoor bacteria range from
Working safely with Biological materials Aseptic technique, sterilization and tissue culture techniques.
3 MANAJEMEN FASILITAS DAN KESELAMATAN ( SAFETY )
USP 797 Guidelines: Compounding Areas and Equipment
12th November, from 8.30 am to 3.30 Venue
洗手及 负压技术 余 波
Author: Nurul Azyyati Sabri
(Modified from University Of South Carolina)
Chapter 5- Facility Equipment
Biosafety Cabinet (BSC): What you need to know?
Laboratory Biosafety and Biosecurity
Aseptic Technique Definitions.
Compounding.
SAFETY CABINETS Welcome to an on-line
Fume Hood – Proper Handling of Chemicals / Proper Functioning
Laboratory Ventilation
Disaster Site Worker Safety
Disaster Site Worker Safety
High and maximum containment laboratories
California State University Fresno
Presentation transcript:

Airflow and BSC Biosafety and Biosecurity Awareness Training For Afghan and Pakistani Bioscientists January 12-14, 2010 SAND No. 2008-0480P Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy’s National Nuclear Security Administration under contract DE-AC04-94AL85000. 1 1

Biological Safety Cabinets (BSCs) Primary means of containment Three design types Class I, Class II, and Class III Designed to provide protection for Personnel Directional flow of air into cabinet Environment HEPA filtered exhaust Product (except Class I) Laminar flow of HEPA filtered air But, how?

Primary Barriers – Ventilation Equipment   Personnel Product Environment Chemical Fume Hoods x Laminar Flow Clean Benches Class I Biological Safety Cabinet Class II Biological Safety Cabinet Class III Biological Safety Cabinet Isolators  

How do HEPA Filters Work? HEPA = High Efficiency Particulate Air Minimum efficiency of 99.97% removal of 0.3 micron particles HEPA filters do not filter out gases, vapors or volatile chemicals, they only filter out particulates (bacteria and viruses)

Class I Biosafety Cabinet Provides personnel and environmental protection, but no product protection Typical applications include: Housing centrifuges, fermenters, cage dumping in an animal lab LABCONCO A. Front opening B. Sash C. Exhaust HEPA D. Exhaust plenum NUAIRE

Class II Biosafety Cabinet Provides personnel, environmental, and product protection Type A2 Exhaust to room or outside through thimble connection 30% recirculated, 70% exhausted Type B2 Must be hard ducted to outside Total exhaust (100%) Pro: may be used with volatile chemicals Con: more expensive to operate, harder to balance airflows in lab

Class II, Types A2 and B2

Class III Biosafety Cabinet

Primary Barriers: Working in Biosafety Cabinets Proper technique is critical to maintaining personnel and product protection! Elements Decontamination Setup Work flow Locations of supplies and waste containers Movement in and out Others Workflow from clean to contaminated (“dirty”)

Recognizing the Limitations of BSCs Personnel protection depends on inward airflow through the work opening Requires proper techniques by user Only small quantities of volatile chemicals in any type of BSC Motors on standard BSCs are not sparkproof Should not use bunsen burners or alcohol lamps in BSCs Over time, heat can damage the HEPA filter Heat can create turbulent airflow, compromising protection And, potential for fire to destroy BSC Buildup of flammable vapors with 70% recirculation BSCs need to be tested and certified regularly to have assurance getting expected protection Prior to service After repairs or relocation Annually

Secondary Barriers Contain the agent within the room or facility in case an agent escapes from the primary barriers Building & Room Construction Separated from public areas Easily cleaned For containment laboratories: Room penetrations sealed Double-door entry HVAC Issues: Directional airflow Exhaust filtration Other Engineering Controls: Solid waste treatment Wastewater treatment Building Room BSC Tube

How do You Establish Directional Airflow? Airflow Offset Control Relies on airflow through doors at all times “Leaky Box” concept Provides “Zone Control” of hazards and odors Lab Zone 1 Lab Zone 2 Lab Zone 3 Directional inward airflow provided such that air will always flow towards areas of higher containment Airflow

Airflow Offset Control 900 cfm Supply 1000 cfm Exhaust How much should the offset be? – IT DEPENDS! (USDA ARS 242.1: 15%, min 50 cfm. 200 cfm more appropriate) Modified by P.Jennette 100 cfm “Leaky” Level 3

Verifying Correct Airflow Before Entering Lab

Heating Ventilation and Air Conditioning (HVAC) Issues Pressure monitoring devices at entry Smoke test HVAC controlled to prevent sustained positive pressurization Interlock exhaust/supply Alarms for HVAC failure (inside and outside the facility) Exhaust air HEPA filtered (sometimes necessary) Sealed ductwork Backflow prevention on supply air (Damper, HEPA) 1978 Smallpox lab infection in Porton Down England - Exhaust failure combined with poor practices led to the escape of virus from the BL4 lab (when the lab became + pressurized without an alarm and workers were discarding waste outside of the biosafety cabinet) -- the virus was carried out of the lab through a penetration around a pipe into a research darkroom on the floor above the containment laboratory.  The infected researcher died, her mother was infected and survived, and the PI took his own life after the autopsy proved his lab was responsible for the researcher's demise.