Science Learning Center Chemistry Pre-laboratory Tutorials Written By Patrick Herklotz.

Slides:



Advertisements
Similar presentations
Science Learning Center Chemistry Pre-laboratory Tutorials Written By Patrick Herklotz.
Advertisements

Using TI graphing calculators
Solving Equations Numerically Figure 4.1a Rename the independent variable x if necessary. For Figure 4.1a, Set up the table. Set up the first column for.
Solving Equations Numerically Figure 2.1a Rename the independent variable x if necessary. For Figure 2.1a, Set up the table. Set up the column for the.
TI-84 Data Fitting Tutorial Prepared for Math Link Participants By Tony Peressini and Rick Meyer Modified for TI-84 / TI-84 Plus by Tom Anderson, Feb.
Science Learning Center Chemistry Pre-laboratory Tutorials Written By Patrick Herklotz.
Digital Solutions Saving and Restoring the PLC.
The TI-83 Plus Elementary Algebra Calculator Tutorial.
Solving Systems of Equations. Graphing There are three methods to solving systems of equations by graphing: 1)Write both equations in slope – intercept.
Texas Instruments TI-83 Plus Graphing Calculator Basic Operations.
Calculator Shortcut – Solving Trinomials
Chemistry e-lab: Acid-Base Titration
Graphing Linear Equations From the beginning. All the slides in this presentation are timed. You do not need to click the mouse or press any keys on the.
Box Plots Calculator Commands 12/1/10. CA Stats Standard 3.02 Locating the 5-Number Summary on TI83/84 A box plot is a graph of the 5-# Summary for a.
Evaluating a Function Given a function y = f(x), we are often interested in finding function values for a given x. One example would be to find ordered.
Table of Contents Matrices - Calculator Operations The graphing calculator can be used to do a variety of matrix calculations, as shown in the following.
Introduction As we saw in the previous lesson, we can use a process called regression to fit the best equation with the data in an attempt to draw conclusions.
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
1 An Introduction to TI SmartView Emulator Software (Version 2.0) Jim Eiting Developmental Mathematics Department Collin County Community College August.
Plotting coordinates into your TI 84 Plus Calculator.
Calculating Variance using the TI 83+ or TI 84+ To be used to instruct in the use of the Texas Instruments calculators for Chapter 16 1.
Lesson 13 Graphing linear equations. Graphing equations in 2 variables 1) Construct a table of values. Choose a reasonable value for x and solve the.
Section 8.1/8.2 Matrix Solutions to Linear Systems Inconsistent and Dependent Systems.
Check it out! 4.3.3: Distinguishing Between Correlation and Causation
Using the TI-83+ Creating Graphs with Data. Preparing to Graph  Once the calculator is on and you have entered data into your lists, press the “Y=“ button.
Dealing with Data Basic Steps to Using the TI-83 Graphing Calculator.
Math on the Mind Model y = –2x + 4 with a table of values and a graph.
A useful tool..  (Formerly) tiny computers – you can even program them.  TI-83+, TI-84+, TI-89 are the ones with which I am most familiar.  There are.
TI – 83 Plus1 A Quick Reference Presentation for AMSTI Year 1 Training.
TI-84 Lists of Data Store the data values to be analyzed using statistical techniques.
Figure 2.1a Evaluating Expressions To evaluate an algebraic expression, we may substitute the value(s) in place of the variable(s) and evaluate the numeric.
The Pressure of Hitting Two Birds with One Stone Elizabeth Ludy & Leann Iacuone John W. North High School.
12/5/2015 V. J. Motto 1 Chapter 1: Linear Models V. J. Motto M110 Modeling with Elementary Functions 1.4 Linear Data Sets and “STAT”
For all work in this unit using TI 84 Graphing Calculator the Diagnostics must be turned on. To do so, select CATALOGUE, use ALPHA key to enter the letter.
Section 2-5 Continued Scatter Plots And Correlation.
2016-USING TECHNOLOGY FOR PROBLEM-SOLVING IN SCIENCE OLYMPIAD KAREN LANCOUR Life Science Rules Committee Chair.
1 Scatter Plots on the Graphing Calculator. 12/16/ Setting Up Press the Y= key. Be sure there are no equations entered. If there are any equations,
Figure 1.1a Evaluating Expressions To evaluate an algebraic expression, we may substitute the values for the variables and evaluate the numeric expression.
How to Master the Calculator By Werbin, Anthony & Montesi, Mick.
Graphing Calculator Steps Steps to follow to find the vertex of a parabola & to find the zeros of a parabola. Make sure you view this in presentation mode.
Do Now Given h(t)= 3− x 1.What is the slope? 2.What is the y-intercept Given t(x)= - 3x − 1 1.What is the slope? 2.What is the y-intercept.
Saving TI-83 List Data to a Program File. Saving TI-83 Lists to a Program Step 1: Create a New Program Press PRGM and arrow over to NEW Press ENTER and.
AP Physics Agenda: Monday September Go over Homework 2. Notes: Objects and Systems 3. Graphing activity 4. Lab: Graph Matching 5. Entry task: Graphing.
AP Physics Agenda: Wednesday September Go over Homework 2. Notes: Objects and Systems 3. Lab: Finish motion detector lab 4. Lab: Motion man 5. Go.
 Boxplot  TI-83/84 Calculator  5 number summary  Do you have an outlier  Modified Boxplot.
CALC Menu - zero Example y = f(x) is given by CALC|zero can be used to find an x-intercept of a graph. Enter the given function into Y1 and use a ZOOM|ZStandard.
Using the TI-83+ Using Lists. Finding the lists  Once the calculator is on, press the STAT key. This key is located in the middle column under the DEL.
Linear Regression A step-by-step tutorial… Copyright © 2007 College of the Redwoods First edition by Aeron Ives.
TI-84 Lists of Data Store the data values to be analyzed using statistical techniques.
MATH 110 UNIT 1 – TRIGONOMETRY Part A. Activity 7 – Find Missing Sides To find an unknown side on a triangle, set up our trigonometric ratios and use.
Making Histograms with the TI-83 Plus Procedure Reference:
TI-83 Plus. GraphLink: an interface helps us to exchange data between a PC and the TI- calculators.
CALC Menu - intersect CALC|intersect is used to find the intersection point of two curves. Example Find all points of intersection for the functions given.
Parametric Equations Lesson Movement of an Object Consider the position of an object as a function of time  The x coordinate is a function of.
Getting Started on the TI-83 Plus Presented by Judy O’Neal North Georgia College & State University.
Vernier Equipment Understanding the Basics of Vernier Technology and Tools Part 2: External Probes and Networking.
Graphing Histograms on the Calculator
Calculations with Lists
Science Learning Center Chemistry Pre-laboratory Tutorials
Science Learning Center Chemistry Pre-laboratory Tutorials
Science Learning Center Chemistry Pre-laboratory Tutorials
USING TECHNOLOGY FOR PROBLEM-SOLVING IN SCIENCE OLYMPIAD
Science Learning Center Chemistry Pre-laboratory Tutorials
Sine Waves Part II: Data Analysis.
4.9 Modeling with Polynomial Functions
Sine Waves Part II: Data Analysis.
Saving TI-83 List Data to a Program File
TI-83 Plus Graphing Calculator
Graphing linear equations
Finding Statistics from Data
Presentation transcript:

Science Learning Center Chemistry Pre-laboratory Tutorials Written By Patrick Herklotz

Menu Options: Click on Links To… Replay Continue Step # Location of Written Instructions Link: Go to Preceding Slide Link: Watch Current Slide Animations Again Link: Advance to Next Slide Instructions Previous Slide

Tutorial 4 Calibrating and Operating the Vernier pH Sensor

Previous Slide Replay Continue Tutorial 4 Calibrating and Operating the Vernier pH Sensor

Top View Previous Slide Replay Continue VERNIER LabPro Quick Setup Start/Stop Transfer Vernier Power Supply STAT PLOT F1 TBLSET F2 FORNAT F3CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH (-) x + - ÷ Enter X -1 X2X2 LOG LN STO> ON SIN, VARS CLEAR TAN > ) Step 1: Assemble the LabPro Calculator as explained in Tutorial 1

Top View Previous Slide Replay Continue VERNIER LabPro Quick Setup Start/Stop Transfer Vernier Power Supply STAT PLOT F1 TBLSET F2 FORNAT F3CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH (-) x + - ÷ Enter X -1 X2X2 LOG LN STO> ON SIN, VARS CLEAR TAN > ) Step 1: Assemble the LabPro Calculator as explained in Tutorial 1.

Top View Previous Slide Replay Continue VERNIER LabPro Quick Setup Start/Stop Transfer Vernier Power Supply STAT PLOT F1 TBLSET F2 FORNAT F3CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH (-) x + - ÷ Enter X -1 X2X2 LOG LN STO> ON SIN, VARS CLEAR TAN > ) Side View Channel 1Channel 2Channel 3Channel 4 Step 2: Obtain the pH sensor and plug it into channel 1. Run the DataMate program by selecting it from the APPS menu in order to allow the calculator to detect the pH sensor.

pH SENSOR Top View Previous Slide Replay Continue VERNIER LabPro Quick Setup Start/Stop Transfer Vernier Power Supply STAT PLOT F1 TBLSET F2 FORNAT F3CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH (-) x + - ÷ Enter X -1 X2X2 LOG LN STO> ON SIN, VARS CLEAR TAN > ) Step 2: Obtain the pH sensor and plug it into channel 1. Run the DataMate program by selecting it from the APPS menu in order to allow the calculator to detect the pH sensor. Side View Channel 1Channel 2Channel 3Channel 4 Channel 1 Port click VERNIER SOFTWARE DATAMATE (VER 1.15) ROM 6.27 (C)2003 Checking Sensors Mode: TIME GRAPH-180 1: SETUP 4: ANALYZE 2: START 5: TOOLS 3: GRAPH 6: QUIT CH 1: Absorbance Mode: TIME GRAPH-180 1: SETUP 4: ANALYZE 2: START 5: TOOLS 3: GRAPH 6: QUIT

Previous Slide Replay Continue Step 3: In the default DataMate program screen, press the 1 key (SETUP). In the next menu, press 2 (CALIBRATE) once the cursor triangle is to the left of CH 1. In the third menu, press the 2 key (CALIBRATE NOW). Power Supply LabPro Calculator Screen TI-84 Silver Edition Texas Instruments pH SENSOR CH 1: PH Mode: TIME GRAPH-180 1: SETUP4: ANALYZE 2: START5: TOOLS 3: GRAPH6: QUIT

Previous Slide Replay Continue Step 3: In the default DataMate program screen, press the 1 key (SETUP). In the next menu, press 2 (CALIBRATE) once the cursor triangle is to the left of CH 1. In the third menu, press the 2 key (CALIBRATE NOW). Power Supply LabPro Calculator Screen TI-84 Silver Edition Texas Instruments pH SENSOR CH 1: PH Mode: TIME GRAPH-180 1: SETUP4: ANALYZE 2: START5: TOOLS 3: GRAPH6: QUIT CH 1: PH CH 2: CH 3: CH 4: DIG1: DIG2: MODE: TIME GRAPH-900 1:OK 3:ZERO 2:CALIBRATE 4:SAVE/LOAD CALIBRATION PH CALIBRATION: LINEAR SLOPE INT 0 4 1:OK 2:CALIBRATE NOW 3:MANUAL ENTRY CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: POINT 2:

- Previous Slide Replay Continue Power Supply LabPro Calculator Screen TI-84 Silver Edition Texas Instruments pH SENSOR ml CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: POINT 2: Step 4: Remove the pH sensor from the solution bottle that keeps it moist. Thoroughly rinse the pH electrode with DI water over a beaker. Always perform this step before measuring the pH of a new solution. Use a Chemwipe to gently rub off strong bases from the sensor’s electrode after rinsing it with DI water.

- Previous Slide Replay Continue Step 4: Remove the pH sensor from the solution bottle that keeps it moist. Thoroughly rinse the pH electrode with DI water over a beaker. Always perform this step before measuring the pH of a new solution. Use a Chemwipe to gently rub off strong bases from the sensor’s electrode after rinsing it with DI water. Power Supply LabPro Calculator Screen TI-84 Silver Edition Texas Instruments CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: POINT 2: pH SENSOR ml Rinse pH electrode with DI water from lab squeeze bottles.

- Previous Slide Replay Continue Power Supply LabPro Calculator Screen TI-84 Silver Edition Texas Instruments pH SENSOR ml Step 5: Place the sensor electrode into a buffer that has a pH of 4. Allow the voltage to stabilize to a reasonably constant value out to the hundredth place past the decimal. This may take seconds. Once this occurs, press the ENTER key. On the next screen, press the 4 key to input the pH of this buffer into the calculators memory. Press the ENTER Key again. CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: POINT 2:

- Previous Slide Replay Continue Step 5: Place the sensor electrode into a buffer that has a pH of 4. Allow the voltage to stabilize to a reasonably constant value out to the hundredth place past the decimal. This may take seconds. Once this occurs, press the ENTER key. On the next screen, press the 4 key to input the pH of this buffer into the calculators memory. Press the ENTER Key again. Power Supply LabPro Calculator Screen TI-84 Silver Edition Texas Instruments CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: POINT 2: pH SENSOR ml ENTER VALUE ? 4 CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: POINT 2:

- Previous Slide Replay Continue Power Supply LabPro Calculator Screen TI-84 Silver Edition Texas Instruments pH SENSOR ml Step 6: Rinse the electrode with DI water. Next, place the pH electrode into a buffer that has a pH of 7. Allow the voltage to stabilize to a reasonably constant value out to the hundredths place past the decimal. Once this occurs, press the ENTER key. On the next screen, press the 7 key to input the pH of this buffer into the calculators memory. Press ENTER to complete the calibrating process. CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: POINT 2:

- Previous Slide Replay Continue Step 6: Rinse the electrode with DI water. Next, place the pH electrode into a buffer that has a pH of 7. Allow the voltage to stabilize to a reasonably constant value out to the hundredths place past the decimal. Once this occurs, press the ENTER key. On the next screen, press the 7 key to input the pH of this buffer into the calculators memory. Press ENTER to complete the calibrating process. Power Supply LabPro Calculator Screen TI-84 Silver Edition Texas Instruments CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: POINT 2: pH SENSOR ENTER VALUE ? 7 CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: POINT 2: CALIBRATION PH CALIBRATION: LINEAR SLOPE INT :OK 2:CALIBRATE NOW 3:MANUAL ENTRY The pH sensor is now calibrated! ml

- Previous Slide Replay Continue Step 7: Press the 1 key [OK] to return to the Settings menu. Press the 1 key [OK] again to return to the main menu. Power Supply TI-84 Silver Edition Texas Instruments pH SENSOR ml CALIBRATION PH CALIBRATION: LINEAR SLOPE INT :OK 2:CALIBRATE NOW 3:MANUAL ENTRY

- Previous Slide Replay Continue Step 7: Press the 1 key [OK] to return to the Settings menu. Press the 1 key [OK] again to return to the main menu. Power Supply TI-84 Silver Edition Texas Instruments pH SENSOR CALIBRATION PH CALIBRATION: LINEAR SLOPE INT :OK 2:CALIBRATE NOW 3:MANUAL ENTRY ml CH 1: PH 7 Mode: TIME GRAPH-180 1: SETUP4: ANALYZE 2: START5: TOOLS 3: GRAPH6: QUIT CH 1: PH CH 2: CH 3: CH 4: DIG1: DIG2: MODE: TIME GRAPH-900 1:OK 3:ZERO 2:CALIBRATE 4:SAVE/LOAD pH reading for a solution

TI-84 Silver Edition Texas Instruments CALIBRATION PH CALIBRATION: LINEAR SLOPE INT 0 4 1:OK 2:CALIBRATE NOW 3:MANUAL ENTRY TI-84 Silver Edition Texas Instruments CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: POINT 2: TI-84 Silver Edition Texas Instruments 1 ENTER VALUE ? 4 TI-84 Silver Edition Texas Instruments CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: POINT 2: TI-84 Silver Edition Texas Instruments 2 ENTER VALUE ? 7 TI-84 Silver Edition Texas Instruments CALIBRATION PH CALIBRATION: LINEAR SLOPE INT :OK 2:CALIBRATE NOW 3:MANUAL ENTRY Previous Slide Replay Continue (2) Press ENTER key (3) Press 4 Key then the ENTER Key (1) Press 2: CALIBRATE NOW (4) Press ENTER key (5) Press 7 key then the ENTER key Calibrating The pH Sensor: Review of Steps 5-7 (6) Press 1 twice to return to default menu screen

TI-84 Silver Edition Texas Instruments CALIBRATION PH CALIBRATION: LINEAR SLOPE INT 0 4 1:OK 2:CALIBRATE NOW 3:MANUAL ENTRY TI-84 Silver Edition Texas Instruments CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: POINT 2: TI-84 Silver Edition Texas Instruments 1 ENTER VALUE ? 4 TI-84 Silver Edition Texas Instruments CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: POINT 2: TI-84 Silver Edition Texas Instruments 2 ENTER VALUE ? 7 TI-84 Silver Edition Texas Instruments CALIBRATION PH CALIBRATION: LINEAR SLOPE INT :OK 2:CALIBRATE NOW 3:MANUAL ENTRY Previous Slide Replay Continue (2) Press ENTER key (3) Press 4 Key then the ENTER Key (1) Press 2: CALIBRATE NOW (4) Press ENTER key (5) Press 7 key then the ENTER key (6) Press 1 twice to return to default menu screen Calibrating The pH Sensor: Review of Steps 5-7

End of Tutorial 4 Menu Options Back to Beginning Previous Slide Finished