Http://www.beluk.de.

Slides:



Advertisements
Similar presentations
DS|POWER DS300 series New generation DSP controlled Uninterruptible power supplies.
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
Installation base of over 25,000 valued installations, Country wide Installation base of over 25,000 valued installations, Country wide Recognised as.
SITOP select Automation and Drives SITOP select Electronic Diagnosis Module Fault diagnosis – rapid and reliable.
ULTRASONIC WATER AND FLOW METERS
Model B1 19-inch Rack Static Transfer Switch. Why choose a model B1 static transfer switch? Increases power availability. True solid state. Rugged, reliable.
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
1/43 New Thyristor Unit Range TO INCREASE MARKET SHARE AND PROFIT A NEW, UNIQUE AND CONSISTENT RANGE.
LP33 Series UPS kVA 400Vac/CE
SYMAP-BC SYMAP-BC.
MTE´s Portable Product Portfolio
© ABB ABB DELTAsingle Commercial and technical presentation.
© ABB ABB ODINsingle Commercial and technical presentation.
Active Power in 1~AC mains Apparent / Reactive / Active Power ~ L ~ C ~ R pure resistor R : phase shift = 0° active power 1 pure reactance L : phase shift.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
DCRK DIGITAL POWER FACTOR CONTROLLERS
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
Make the most of your energy December 2008 PowerLogic Enercept Submetering ….when space is at a premium PowerLogic® Enercept Meter.
MIG II DIGITAL FEEDER PROTECTION
EDIA DIVISION Titre de la présentation en Arial, 45 Alpican capacitors F.Dupré 09/11/2012.
CALPORT 300 Three-Phase Portable Reference Standard
Rocker Switches  Available in illuminated, Non-illuminated and Central illuminated version  Suitable for switching resistive and inductive load  Wide.
1 INPUT & OUTPUT ■ INPUT * Voltage Side ( PT side ) Operational range : 0-110% Permissible over range : 150% for 10 seconds 120% continuously * Current.
PPS 3.3 C Portable Power Source Page 1 January 2011.
Portable Working Standard and Power Quality Analyzer
Settings & Adjustments. Settings & Adjustments.
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
SFT 2841 IN CONNECTED MODE Prepare setting files.
1 HD SIGNAL CONDITIONER SERIES THERMOCOUPLE TRANSMITTER MODEL HD-TC MODEL & SUFFIX CODE SELECTION HD-TC MODEL ■ Output1 signal ■ Output2 signal Availability.
Page 1 March 2007 CheckSource 2.3 Portable Power Phantom Load.
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
© 2007 Ideal Industries 1 of 32 Intro To Ideal 800 Power Analyzer Basics of IDEAL Industries 800 Series Power Analyzer.
PTS 2.3 C Portable Test System Page 1 March 2009.
1 HD SIGNAL CONDITIONER SERIES POWER DISTRIBUTOR TRANSMITTER MODEL HD-IPC MODEL & SUFFIX CODE SELECTION HD-IPC MODEL ■ Input signal ■ Output1 signal ■
1 HD SIGNAL CONDITIONER SERIES SAMPLE HOLD TRANSMITTER MODEL HD-SHC MODEL & SUFFIX CODE SELECTION HD-SHC MODEL ■ Output2 signal Availability as Output1.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
7 Programmable DC Power Supply EPS Series ■ Features & Benefits * Linear type power supply * Easy to control voltage & current with jog shuttle * 4-Digit.
1 HD SIGNAL CONDITIONER SERIES LIMITER TRANSMITTER MODEL HD-LIM MODEL & SUFFIX CODE SELECTION HD-LIM MODEL ■ Output1 signal ■ Output2 signal Availability.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
INSTApower Compact Power Supplies. INSTA POWER INSTA POWER – Primary switch-mode power supplies The trend in the range of power supplies goes more and.
PMC-592 HMI's Front Panel Operation
DIGITAL MULTIMETER DMG
POWER FACTOR CORRECTION
AUTOMATIC POWER FACTOR CONTROLLERS
Intellectual Insulation Indicator «3i»
VARLOGIC NRC12 Varmetric Controller
APFC-03 Reactive Power Compensation Method & Settings
HD POWER TRANSDUCER SERIES
New EM210_AV.
ABB i-bus® KNX Valve Drive Actuator VAA/A
HD POWER TRANSDUCER SERIES VOLT-DEMAND TRANSDUCER
Portable Working Standard
HD SIGNAL CONDITIONER SERIES POTENTIOMETER TRANSMITTER
PTS 3.3 C Portable Test System.
flow process control trainer
HD SIGNAL CONDITIONER SERIES
HD POWER TRANSDUCER SERIES
HD POWER TRANSDUCER SERIES
FEEDER PROTECTION UNIT
HD SIGNAL CONDITIONER SERIES ISOLATED SIGNAL TRANSMITTER
Analog Room Command Module
NSA-7000 Stylish flush mount Network Sensors
Customer Presentation
HD POWER TRANSDUCER SERIES
HD SIGNAL CONDITIONER SERIES
PowerLogic™ offer for the basic metering market
PowerLogic PM5350 High-performance multifunction power meter
MULTI - DPG.
PM9, PM9P and PM9C Power Meter
Presentation transcript:

http://www.beluk.de

EMM-5 Power Analyzer Measuring all important electrical values Supervision of electrical values Good clearness of display Easy operating and commissioning Reliability in operation

Technical Data of EMM-5 Supply voltage: 99 – 121V, 45-65Hz, 10VA, max. fuse gL 6A Voltage measuring: 55/95V – 318/550V,45-65 Hz, VT-ratio 1 - 4000 Current measuring: 0-5A, sensitivity 25 mA, burden 15mOhm CT required, CT-ratio 1-10000 Overload: 20% permanent, 50A for 1 sec. Temperature measuring: Temperaturemeasuring on the backside Interface: additional interfaces on request Ambient temperature: Operating: 0°C ... +70°C, storing: -20°C ... +85°C Humidity: 0% - 95%, without moisture condensation Overvoltage category: II, pollution degree 3 (DIN VDE 0110, Teil 1 / IEC 60664-1)

Technical Data of EMM-5 Standards: DIN VDE 0110 Teil 1 (IEC 60664-1:1992) VDE 0411 Teil 1 (DIN EN 61010-1 / IEC 61010-1:2001) VDE 0843 Teil 20 (DIN EN 61326 / IEC 61326:1997 + A1:1998 + A2:2000) Conform and listing: CE, UL, cUL Connection: Plug-terminals, screw-type, max. 2,5qmm Housing: Instrument casing Protection class: Front: IP50, rear: IP20 Dimensions: 144 x 144 x 59 mm H x W x D, cut out 138+0,5 x 138+0,5 mm Weight: ca. 650 gr

Technical Data of EMM-5 Dimensions: Connecting diagram:

Accuracy measurement of EMM-5 UPH-N: 55 – 318V +/- 0,5% UPH-PH: 95 – 550V +/- 0,5% I L1, L2, L3, N: 0,01 – 5,00A +/- 0,5% F: 45 – 65 Hz +/- 0,1 Hz cos L1, L2, L3: c 0,00 – i 0,00 +/- 0,01 S tot: 0 – 180 GVA +/- 1,0% P tot: 0 – 180 GW +/- 1,0% Q tot: 0 – 180 GVar +7- 1,0% Wp imp. tot: 9 - digit Wp exp. tot: 9 - digit Wq kap. tot: 9 - digit Wq ind. tot: 9 - digit Harm. U 2. – 63.: 0,0 – 100,0% Harm. I 2. – 63.: 0,0 – 100,0%

Installation of EMM-5 Necessary connections: - 115 V AC voltage for internal power supply - Voltage measurement L1, L2, L3, (N) - Current measurement via current measurement transformers

Menu Navigation of EMM-5 Start-Menu Grafical LCD (128x64) backlight with 2 different luminosity (use / not use) After connecting display contrast can be adjusted function of keys Membrane keyboard 4 keys function is shown in LCD Main-Menu Contrast setting Main-Menu

Menu Navigation of EMM-5 Main-Menu cursor marks items no function mark item select item

Next / previous measurement Measurement Menu of EMM-5 Measurement ULN: phase to neutral Unit is changing between V and kV ULL: phase to phase I: RMS values of foundamental wave Main-menu Next / previous measurement No function

Next / previous measurement Measurement Menu of EMM-5 Measurement I: RMS values of foundamental wave f: frequency S: apparent power P: active power Q: reactive power cp: cosine of the fundamental phase angles Main-menu Next / previous measurement No function

Menu Navigation of EMM-5 Main-Menu cursor marks items HARMONICS

Harmonics Menu of EMM-5 Harmonics measurement Data sources: I – L1 Exemplary display of data source U-L1 I - N U – L1 U – L2 U – L3 Main-menu Move to higher/lower harmonics Select data source

Menu Navigation of EMM-5 Main-Menu cursor marks items WORK

Work Menu of EMM-5 Work Displayed values: WP-import WP-export WQ-inductive WQ-capacitive Units changing automatically Main-menu

Menu Navigation of EMM-5 Main-Menu cursor marks items SETUP

Setup Menu of EMM-5 Password protected Protection by a numerical password with 4 digits. The password cannot be changed. - Number + next digit Enter

SETUP of EMM-5 SETUP cursor marks items Setup-menu: - parameter modbus reset settings reset work main-menu mark item select item

SETUP of EMM-5 Parameter System parameters: - ratio of a VT ratio of a CT for L1, L2, L3 ratio of a CT for N measure I N separately or calculate it display contrast setting main-menu mark item select item

SETUP of EMM-5 Modbus cursor marks items Modbus settings: - modbus slave adress data transfer speed parity setting main-menu mark item select item

SETUP of EMM-5 Reset settings cursor marks items Settings are resetable to standard values main-menu mark item select item

SETUP of EMM-5 Reset work cursor marks items Resets work counters main-menu mark item select item

Menu Navigation of EMM-5 Main-Menu DEVICE INFO

Measurement Menu of EMM-5 Device info Details about: Software version Hardware revision number Serial number Main-menu

The end