CVFD Training – Hose Practices

Slides:



Advertisements
Similar presentations
Intermediate SFFMA Objectives: – Hrs Received
Advertisements

Chapter 13 Lesson Goal After completing this lesson, the student shall be able to use, care for, and perform maintenance on fire hose, couplings, hose.
Fire Hose and Appliances
Learning Objective 1 Describe the safety considerations taken when service testing a fire hose.
Lesson Using Construction Fasteners and Hardware.
© 2012 Delmar, Cengage Learning Automotive Plumbing: Tubing and Pipe Chapter 24.
2 Fire Fighter Qualifications and Safety Skill Drills.
FIREFIGHTER I LESSON 12A. FIRE HOSE TERMS Expansion-ring gasket Expansion-ring gasket — Gasket used at the end of hose where it is expanded into coupling.
The Cleveland Load.
Winchester Fire - Rescue
Fire Hose & Appliances Part D & Homework.
Chapter 13 Lesson Goal After completing this lesson, the student shall be able to use various hose appliances and tools, prepare a test site for service.
Hydraulic Power Assist
MyLock 644D Service Seminar.
Getting Wet Stuff to the Red Stuff For 300 Years
Fire Hoses and Appliances Firefighter II Module A
Fire Hose Skills Firefighter II.
FIRE HOSE AND APPLIANCES
Lead instructor Gerry Pierce. Hose Testing Objectives  Construction of fire hose.  Sizes of fire hose (used at WFRD)  Use and care of fire hose. 
Fire Hose and Appliances
ROSENBAUER REAR-MOUNT SPEED-LAYS
Blackwood Fire Company TL84 LDH Deployment/Restoration Training Module.
Intermediate SFFMA Objectives: – Hrs received.
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Augmenting Fire Standpipe Systems
Riding Assignments Presentation February 28, 2011.
Unit 5 Use of Water. Unit 5 Objectives b Explain different types of water use operations b Demonstrate laying a wet line with both simple and progressive.
Water Supply Advantage of water as extinguishing agent w Water Abundance w Excellent heat absorption qualities w Easily moved long distances w Easily stored.
Pumping Apparatus Driver/Operator
5/18/2015Dixon High School Fire Department1 Introduction The Recruit will also practice and masters certain skills and will be tested on these skills.
Fire Streams SFFMA Training Objectives: –
Fire Apparatus Familiarization
March 2001 Training Hillcrest Fire Department. Before we get started Pair up with someone Take and record their vitals.
Fire Hose / Appliances FFII Hillcrest Fire Department © 2001.
FVCC Fire Rescue LADDERS.
CVFD Training – Ladder Practices SFFMA Training Objectives –
C L A S #4 Driver Operator Refresher Training.
Sling Safety.
Ropes and Knots 1. Introduction Rope is one of the most important and routinely used tools in the fire service. In this chapter, you will learn: How to.
Fire Hoses, Nozzles, Portable lighting, appliances, and ladders.
Fire Hose, Nozzles, Streams, and Foam
Carpentersville Fire Department
Chapter 13 Lesson Goal After completing this lesson, the student shall be able to use, care for, and perform maintenance on fire hose, couplings, hose.
FIREFIGHTER II LESSON 12. TYPES OF VALVES Ball — Ball — Controls nozzle flow and pump discharge rates Gate — Gate — Controls hydrant flow Butterfly.
1402 Hybrid Firefighter II 6th Edition Chapter 15 — Fire Hose South Carolina Fire Academy.
FVCC Fire Rescue FIRE HOSE AND APPLIANCES. OBJECTIVES 2-7.1Identify the construction features of hose (3-3.7, 3-3.9) 2-7.2Identify the types of fire hose.
Fire Stream and Line Selection Firefighter II. Copyright © Texas Education Agency All rights reserved. Images and other multimedia content used.
Fire Service Hose Firefighter II. Copyright and Terms of Service Copyright © Texas Education Agency, These materials are copyrighted © and trademarked.
Fire Hose, Nozzles, Streams, and Foam
Part C  Accordion load  Lay the first length of hose in the bed on edge against the partition with the coupling at the rear of the bed  At the front.
Flex Cam – Training This shows one version of a complete FlexCam system including Power Unit HCP and Compact Cam CC for piercing operation.
21 Fire Suppression Skill Drills. 2 Objectives Apply water using the direct, indirect or combination attack. Use a large handline using the one- or two-
POWER TOOLS Electric drills
HOSE ROLLS Straight roll ◦Lay the hose out straight and flat on a clean surface ◦Roll the male coupling over onto the hose to start the roll ◦Form a coil.
RIT Technician February Part 2 first quarter 2016.
SAFE WORK PRACTICES IN AGRICULTURAL MECHANICS AG MECH II.
Rapid Change Technology The following is a presentation to aid Technicians in the replacement of the Rapid Change Technology Block.
Essentials of Fire Fighting 6 th Edition Firefighter I Chapter 15 — Fire Hose.
Fire Hose, Nozzles, and Streams
IFSTA Chapter 16 Fire Streams
Fire Hose, Nozzles, And Appliances
Water Supply (Fire Fighter I)
Fire Attack and Foam (Fire Fighter I)
MAGM 262 Hydraulic Seals Mr. Conrado.
Essentials of Fire Fighting
FVCC Fire Rescue LADDERS PART B.
Harwich Fire Department
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Fire Hose, Appliances, and Nozzles
Essentials of Fire Fighting Maintenance and Testing Responsibilities
Presentation transcript:

CVFD Training – Hose Practices SFFMA Training Objectives: 4-01.01,.02,.05,.06,.07,.08,.09,.10,.11,.13,.14

Fire Hose Produced in different diameters, each for specific purposes Size refers to outside diameter Most commonly cut, coupled into pieces of 50 or 100 feet (15 or 30 m) (Continued) Firefighter I

Fire Hose Firefighter I

Intake Hose Used to connect fire department pumper or portable pump to water source Two groups Soft intake hose Hard intake hose Firefighter I

NFPA® Standards NFPA® 1961, Standard on Fire Hose, lists specifications for fire hose NFPA® 1963, Standard for Fire Hose Connections, lists specifications for fire hose couplings and screw threads (Continued) Firefighter I

NFPA® Standards NFPA® 1901, Standard for Automotive Fire Apparatus, requires pumpers to carry varying sizes/amounts of hose Firefighter I

Fire Hose Damage — Mechanical Slices, rips, abrasions on coverings Crushed/damaged couplings Cracked inner linings Certain practices prevent damage Firefighter I

Fire Hose Damage — Thermal Excessive heat/direct flame contact can char, melt, weaken outer jacket and dehydrate rubber lining Inner linings can be dehydrated when hose hangs to dry too long Certain practices prevent damage Firefighter I

Fire Hose Damage — Organic Rubber-jacket hose not subject to damage caused by living organism, but this is a problem on hose with woven jacket of natural fiber if stored wet Mildew, mold rot fibers of hose jacket, causing hose to rupture under pressure (Continued) Firefighter I

Fire Hose Damage — Organic If outer jacket made of synthetic fibers, will resist organic damage Outer jacket of some natural-fiber hose has been chemically treated to resist mildew, mold; not always 100 percent effective Certain practices prevent damage Firefighter I

Fire Hose Damage — Chemical Chemicals, chemical vapors can damage outer jacket on hose or cause rubber lining to separate from inner jacket When hose exposed to petroleum products, paints, acids, alkalis, may be weakened (Continued) Firefighter I

Fire Hose Damage — Chemical Runoff water from fire may carry foreign materials that can damage hose Certain practices prevent damage Firefighter I

Washing Hose Method depends on type of hose Hard rubber booster hose, hard intake hose, rubber-jacket collapsible hose Woven-jacket fire hose (Continued) Firefighter I

Washing Hose When jacket exposed to oil Wash with mild soap/detergent using common scrub brush Make sure oil completely removed Thoroughly rinse with clear water (Continued) Firefighter I

Washing Hose Hose washing machines Can make care, maintenance easier Wash almost any size fire hose up to 3 inches (77 mm) Flow of water into device can be adjusted as desired Movement of water assists in propelling hose through device (Continued) Firefighter I

Washing Hose Hose washing machines Hoseline that supplies water can be connected to pumper or used from hydrant Higher water pressure equals better results Cabinet-type machine Courtesy of Thomas Locke and South Union Volunteer Fire Company. Firefighter I

Drying Hose Woven-jacket must be thoroughly dried before being reloaded on apparatus Methods depend on type of hose Should be in accordance with SOP, manufacturer’s recommendations Some may be placed on apparatus wet with no ill effects Firefighter I

DISCUSSION QUESTION How is hose washed in your department? Firefighter I

Storing Hose After hose has been brushed, washed, dried, should be rolled and stored in suitable racks unless it is to be placed back on apparatus (Continued) Firefighter I

Storing Hose Hose racks Located in clean, well-ventilated room or close to apparatus Can be freestanding on floor or mounted permanently on wall If mobile, can be used to store and move hose Firefighter I

Threaded Fire Hose Couplings Consist of two major components Male — External threads Female — Internal threads (Continued) Firefighter I

DISCUSSION QUESTION Why is it important to be able to differentiate between the male and female couplings during search and rescue operations? Firefighter I

Threaded Fire Hose Couplings Disadvantage — One male, one female necessary to make connection unless double-male or double-female adapter used (Continued) Firefighter I

Threaded Fire Hose Couplings Intake hose Sometimes equipped with two-piece female hose couplings on each end Threaded hose couplings on large intake hose equipped with extended lugs providing handles for attaching to hydrant outlet/pump intake Shank — Portion of coupling that serves as point of attachment to hose (Continued) Firefighter I

Threaded Fire Hose Couplings Lugs Aid in tightening, loosening couplings Aid in grasping coupling when making, breaking coupling connections Types (Continued) Firefighter I

DISCUSSION QUESTION Which lugs do you think are the best to use? Why? Firefighter I

Threaded Fire Hose Couplings Higbee cut Special type of thread design Eliminates cross-threading One rocker lug on each half has small indentation to mark where Higbee cut begins Firefighter I

Storz Couplings Referred to as sexless couplings No distinct male/female components Identical to, may be connected to other Storz couplings of same size Designed to be connected/disconnected with quarter turn (Continued) Firefighter I

Storz Couplings Have lugs, slots built into swivel rings of each coupling for locking Must have locking devices if attached to large-diameter hose Firefighter I

Rules for Care of Fire Hose Couplings Avoid dropping/dragging Do not permit vehicles to run over hose Inspect couplings when hose washed/ dried Remove gasket, twist swivel in warm, soapy water (Continued) Firefighter I

Rules for Care of Fire Hose Couplings Clean threads to remove tar, dirt, gravel, oil Inspect gasket, replace if cracked/ creased Firefighter I

Cleaning Fire Hose Couplings Hose-washing machines will not clean sufficiently Swivel part should be submerged in warm, soapy water and worked forward and backward (Continued) Firefighter I

Cleaning Fire Hose Couplings Male threads should be cleaned with stiff brush Wire brush may be necessary Swivel gasket Expansion-ring gasket Firefighter I

DISCUSSION QUESTION What is a complete hose layout? Firefighter I

Hose Appliances Any piece of hardware used with fire hose to deliver water (Continued) Firefighter I

Hose Appliances Valves Control flow of water in hoselines, at hydrants, at pumpers Ball valves Gate valves Butterfly valves Clapper valves (Continued) Firefighter I

Hose Appliances Valve devices Allow number of hoselines operating on fire ground to be increased/decreased Wye appliances Siamese appliances (Continued) Firefighter I

Hose Appliances Valve devices Water thief appliances Large-diameter hose appliances Hydrant valves (Continued) Firefighter I

DISCUSSION QUESTION What are some other names for hydrant valves? Firefighter I

Hose Appliances Fittings (Continued) Firefighter I

Hose Appliances Intake strainers Devices attached to drafting end of hard intake to keep debris from entering fire pump Guidelines for use Firefighter I

Hose Tools Hose roller Prevents damage to hose that can occur when dragged over sharp corners such as roof edges, windowsills (Continued) Firefighter I

Hose Tools Hose roller Consists of metal frame with two or more rollers Can be used for protecting rope from similar edges (Continued) Firefighter I

Hose Tools Hose jacket Can be installed on ruptured section of hoseline to temporarily close rupture (Continued) Firefighter I

Hose Tools Hose jacket Consists of hinged two-piece metal cylinder Made in two sizes Encloses hose so can operate at full power Can be used to connect mismatched hose (Continued) Firefighter I

Hose Tools Hose clamp Can be used to stop flow of water in hoseline (Continued) Firefighter I

Hose Tools Hose clamp Three types — Screw-down, press-down, hydraulic press Can injure firefighters/damage hose Several general rules for use (Continued) Firefighter I

Hose Tools Spanner Used to tighten/loosen couplings May have other built-in features (Continued) Firefighter I

Hose Tools Hydrant wrench Used to remove caps from hydrant outlets, open hydrant valves Equipped with pentagonal opening fitting most standard hydrant operating nuts May be equipped with spanner (Continued) Firefighter I

Hose Tools Rubber mallet — Strike lugs to tighten/loosen couplings Hose bridge/ramp Helps prevent damage to hose Should be used where hose laid across street Can be positioned over small spills Can be used as chafing blocks (Continued) Firefighter I

Hose Tools Chafing blocks Used to protect fire hose where subjected to rubbing from vibrations Useful where intake hose comes in contact with pavement May be wood, leather, old truck tires (Continued) Firefighter I

Hose Tools Hose strap, hose rope, hose chain Used to carry, pull fire hose Provide more secure means to handle pressurized hose when applying water Firefighter I

Straight Roll Simplest Starts at one end, usually male coupling; to complete roll hose toward other end When complete, female end exposed and male protected in center of roll (Continued) Firefighter I

Straight Roll Used in situations Easy loading of minuteman load When loaded back on apparatus at fire When returned to quarters for washing When placed in storage Easy loading of minuteman load Methods to indicate need for repair/test Firefighter I

Donut Roll Used in situations where hose is likely to be deployed for use directly from roll (Continued) Firefighter I

Donut Roll Advantages over straight roll Better control Hose rolls out easier Facilitates connecting to other couplings Can be performed by 1-2 firefighters Firefighter I

Twin Donut Roll Works well on 1½-inch (38 mm) and 1¾-inch (45 mm) hose Creates compact roll that is easily transported, carried If couplings offset about 1 foot (0.3 m), can be coupled together after roll tied Firefighter I

Self-Locking Twin Donut Roll Twin donut roll with built-in carrying loop formed from hose itself Loop locks over couplings to keep intact Length of carrying loop may be adjusted Firefighter I

DISCUSSION QUESTION Are there any hose rolls specific to your department or jurisdiction? Firefighter I

Hose Beds Hose compartments on fire apparatus Vary in size, shape Sometimes built for specific needs Front of hose bed Rear of hose bed Split beds Firefighter I

Hose Loading Guidelines Check gaskets, swivel before connecting couplings Keep flat sides of hose in same plane when two sections connected Tighten couplings hand-tight Remove kinks, twists when bent to form loop in hose bed (Continued) Firefighter I

Hose Loading Guidelines Make short fold/reverse bend in hose during loading so couplings not too close to front or rear of hose bed and will not flip over when pulled out of bed (Continued) Firefighter I

Hose Loading Guidelines Load large-diameter hose with all couplings near front of bed Do not pack too tightly; should permit gloved hand between folds Firefighter I

Accordion Load Derives name from manner in which it appears after loading Procedure Advantages Firefighter I

Horseshoe Load Named for way it appears after loading Procedure Advantage Disadvantages (Continued) Firefighter I

Horseshoe Load In single hose load, may be started on either side Steps for split hose bed Firefighter I

Flat Load Easiest to load Suitable for any size supply hose Best way for large-diameter hose Advantage Disadvantage Courtesy of Sam Goldwater. (Continued) Firefighter I

Flat Load May be started on either side of single hose bed In split hose bed, lay first length against partition with coupling hanging appropriate distance below hose bed Large-diameter hose Firefighter I

Finishes for Forward Lays Designed to facilitate making hydrant connection Not as elaborate as finishes for reverse lays (Continued) Firefighter I

Finishes for Forward Lays Straight finish Last length or two of hose flaked loosely back and forth across top of hose load Associated with forward- lay operation Hydrant wrench, gate valve, adapters strapped to hose near female coupling Firefighter I

Finishes for Reverse Lays Reverse horseshoe finish Similar to horseshoe load One or two 100-foot (30 m) lengths of hose Can be used with any size attack hose Can be used for preconnected line Can be loaded in two or three layers Can be pulled from bed for arm carry (Continued) Firefighter I

Finishes for Reverse Lays Reverse horseshoe finish (Continued) Firefighter I

Finishes for Reverse Lays Skid load finish Folding last three lengths of hose into compact bundle on top of rest of load Begins by forming 3+ pull loops extending beyond end of hose load Rest of hose accordion-folded across hose used to form pull loops (Continued) Firefighter I

Finishes for Reverse Lays Firefighter I

Preconnected Hose Loads for Attack Lines Primary lines used for fire attack by most departments Connected to discharge valve, placed in area other than main hose bed Range from 50-250 feet (15-75 m) Can be carried in several places Firefighter I

Preconnected Flat Load Adaptable for varying widths of hose beds Often used in transverse beds Similar to flat load for large supply hose except Preconnected Loops provided to aid in pulling from bed Firefighter I

Triple Layer Load Begins with hose folded in three layers Designed to be pulled by one person Disadvantage Can be used for all sizes attack lines Often preferred for larger lines Firefighter I

Minuteman Load Designed to be pulled, advanced by one Advantage Pays off shoulder as firefighter advances toward fire Well suited for narrow hose bed Disadvantages Firefighter I

Booster Hose Reels Used for booster lines May be mounted in any of several places on apparatus Should be loaded one layer at a time in an even manner May be hand- or power-operated Firefighter I

DISCUSSION QUESTION What hose loads are used in your department? Firefighter I

Guidelines When Laying Hose Do not ride in standing position to lay hose when apparatus moving Drive apparatus at speed no greater than one that allows couplings to clear tailboard as hose leaves bed Lay hose to one side of roadway Firefighter I

Forward Lay (Continued) Firefighter I

Forward Lay Hose laid from water source to fire Used when source is a hydrant and pumper must be positioned near fire Hose beds should be loaded so first coupling off is female Operation (Continued) Firefighter I

Forward Lay Advantages Disadvantages Information for firefighter at hydrant Making hydrant connection Using four-way hydrant valves Firefighter I

Reverse Lay (Continued) Firefighter I

Reverse Lay Hose laid from fire to water source Used when pumper must first go to fire location so size-up can be made before laying supply line Most expedient way to lay hose if apparatus must stay close to water (Continued) Firefighter I

Reverse Lay Hose beds should be loaded so first coupling off hose bed is male Has become standard method for setting up relay pumping operation when using 2½-inch or 3-inch (65 or 77 mm) hose as supply line (Continued) Firefighter I

Reverse Lay Long lays of large hose may require pumper at hydrant to increase pressure in supply hose Most direct way to supplement pressure, set up drafting operations Disadvantages (Continued) Firefighter I

Reverse Lay Procedures if operation involves two pumpers Does not require four-way hydrant valve Also used when pumper arrives at fire and must work alone for extended time (Continued) Firefighter I

Reverse Lay Making hydrant connections with soft intake hose Making hydrant connections with hard intake hose Firefighter I

Split Lay (Continued) Firefighter I

Split Lay Any of a number of ways to lay multiple supply hoses with a single engine Various types If equipped with sexless couplings, direction of lay is unimportant May other options when hose bed is divided Firefighter I

Pulling Preconnected Hoselines Preconnected flat load Minuteman load Triple layer load Firefighter I

Other (Not Preconnected) Hoselines Usually 2½-inches (65 mm) or larger Wyed lines Shoulder loads from flat/horseshoe loads Shoulder loads from accordion or flat loads Firefighter I

Working Line Drag One of quickest, easiest ways to move fire hose at ground level Use limited by available personnel Firefighter I

Advancing Hoselines Difficult when deploying up or down stairways, from standpipes, up ladders, deep into buildings Easier when uncharged Firefighter I

Guidelines When Advancing Hoseline into Burning Structure Bleed air from charged hoselines before entering Position nozzle operator, all members of hose team on same side of hoseline Check doors for heat before opening (Continued) Firefighter I

Guidelines When Advancing Hoseline into Burning Structure Stay low, avoid blocking ventilation openings Chock self-closing doors open Check for, remove kinks from line Firefighter I

Advancing Hose Up Stairway Should be advanced up stairways uncharged when conditions allow Lay uncharged hose against outside wall to keep stairs clear as possible, avoid sharp bends and kinks in hose If possible, position firefighter at every turn/point of resistance Firefighter I

DISCUSSION QUESTION Why should hose be uncharged when advancing up a stairway? Firefighter I

Advancing Hose Down Stairway Advancing uncharged hoseline easier than charged Advancing uncharged line recommended only when no fire, very minor fire (Continued) Firefighter I

Advancing Hose Down Stairway Excess hose should be flaked outside stairwall Firefighters must be positioned at corners, pinch points Firefighter I

Advancing Hose From Standpipe Getting hose to upper floors of high-rise buildings can be challenging One solution is to have hose rolls or packs on apparatus ready to carry aloft and then connect to standpipe system (Continued) Firefighter I

Advancing Hose From Standpipe Hose must be brought to fire floor over aerial ladder or by interior stairway Crews normally stop one floor below fire floor and connect to standpipe If standpipe in enclosed stairwell, it is acceptable to hook up on fire floor (Continued) Firefighter I

Advancing Hose From Standpipe Steps once at standpipe connection Be alert for pressure-relief devices and follow SOPs for removal/connection If using certain sizes of hose, place gated wye on standpipe outlet (Continued) Firefighter I

Advancing Hose From Standpipe 2½-inch (65 mm) attack line may be used depending on size, nature of fire Extra hose should be flaked up stairs toward floor above fire During pickup operations, carefully drain water to prevent unnecessary damage Firefighter I

Advancing Hose Up Ladder Easier and safer with uncharged line Advancing charged line Operating hoseline from ladder Firefighter I

Controlling Loose Hoseline Very dangerous because it may flail about or whip back and forth Firefighters, bystanders may be seriously injured or killed Methods for controlling Firefighter I

Replacing Burst Sections Hose clamp or kink can be used to stop flow of water when replacing burst section of hose Two additional sections of hose should be used to replace any one bad section Firefighter I

Operating Small Handlines — One-Firefighter Method Only used during overhaul after fire or for very small outdoor nuisance fires Requires hoseline to be straight at least 10 feet (3 m) behind nozzle Firefighter should hold nozzle with one hand and hose with the other Firefighter I

Operating Small Handlines — Two-Firefighter Method Usually needed when nozzle must be advanced Nozzle operator duties Backup firefighter duties Firefighter I

Operating Large Handlines — One-Firefighter Method NOT recommended when nozzle is connected to large handline May be used during exposure protection/overhaul operations if master stream device unavailable (Continued) Firefighter I

Operating Large Handlines — One-Firefighter Method Large loop formed that crosses over line behind nozzle Firefighter sits on intersection where hose crosses and directs stream (Continued) Firefighter I

Operating Large Handlines — One-Firefighter Method To reduce fatigue, nozzle operator can use hose strap or utility strap looped over shoulder or reduce nozzle flow if conditions allow Does not permit much maneuvering Firefighter I

Operating Large Handlines — Two-Firefighter Method #1 Uses means of anchoring hose because of nozzle reaction Nozzle operator duties Backup firefighter duties Firefighter I

Operating Large Handlines — Two-Firefighter Method #2 Uses hose rope tools or utility straps to assist in anchoring hose Nozzle operator duties Backup firefighter duties Firefighter I

Operating Large Handlines — Three-Firefighter Method In all cases, positioning of nozzle operator same as for two-firefighter method (Continued) Firefighter I

Operating Large Handlines — Three-Firefighter Method Some departments prefer first backup firefighter to stand behind nozzle operator with third firefighter kneeling on hose behind second firefighter Another method is for all firefighters to use hose straps and remain standing Firefighter I