Calorimeters Purpose of calorimeters EM Calorimeters

Slides:



Advertisements
Similar presentations
Silicon detectors in HEP
Advertisements

Experimental Particle Physics
STFC RAL Graduate lectures 2007/8 R M Brown - RAL 1 An introduction to calorimeters for particle physics Bob Brown STFC/PPD.
Gamma-Ray Spectra _ + The photomultiplier records the (UV) light emitted during electronic recombination in the scintillator. Therefore, the spectrum collected.
HEP Experiments Detectors and their Technologies Sascha Marc Schmeling CERN.
Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
Particle interactions and detectors
Detection of Gamma-Rays and Energetic Particles
Cosmic Rays Basic particle discovery. Cosmic Rays at Earth – Primaries (protons, nuclei) – Secondaries (pions) – Decay products (muons, photons, electrons)
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Counting Cosmic Rays through the passage of matter By Edwin Antillon.
Scintillators.
Particle Interactions
Calorimetry: Energy Measurements
High Energy Detection. High Energy Spectrum High energy EM radiation:  (nm)E (eV) Soft x-rays X-rays K Soft gamma rays M Hard gamma.
Techniques for detecting X-rays and gamma-rays Pair production Creation of elementary particle and its antiparticle from a photon. Occurs only if enough.
Main detector types Scintillation Detector Spectrum.
Calorimeters A User’s Guide Elizabeth Dusinberre, Matthew Norman, Sean Simon October 28, 2006.
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
Stopping Power The linear stopping power S for charged particles in a given absorber is simply defined as the differential energy loss for that particle.
1 Calorimetry - 2 Mauricio Barbi University of Regina TRIUMF Summer Institute July 2007.
Photon detection Visible or near-visible wavelengths
1 Scintillators  One of the most widely used particle detection techniques Ionization -> Excitation -> Photons -> Electronic conversion -> Amplification.
Lecture 1.3: Interaction of Radiation with Matter
Space Instrumentation. Definition How do we measure these particles? h p+p+ e-e- Device Signal Source.
Calibration of the ZEUS calorimeter for electrons Alex Tapper Imperial College, London for the ZEUS Collaboration Workshop on Energy Calibration of the.
How do we detect photons? Kensuke Okada RIKEN BNL Research Center April 20,
Particle Detectors for Colliders Calorimeters Robert S. Orr University of Toronto.
Photodetection EDIT Internal photoelectric effect in Si Band gap (T=300K) = 1.12 eV (~1100 nm) More than 1 photoelectron can be created by light in silicon.
1 Methods of Experimental Particle Physics Alexei Safonov Lecture #11.
Calorimeters Chapter 4 Chapter 4 Electromagnetic Showers.
Medical Imaging Radiation I. Naked to the Bone: Medical Imaging in the Twentieth Century (Paperback)by Bettyann Kevles Bettyann Kevles E=mc2: A Biography.
1 dE/dx  Let’s next turn our attention to how charged particles lose energy in matter  To start with we’ll consider only heavy charged particles like.
Experimental Particle Physics PHYS6011 Joel Goldstein, RAL 1.Introduction & Accelerators 2.Particle Interactions and Detectors (2/2) 3.Collider Experiments.
Calorimeters Chapter 21 Chapter 2 Interactions of Charged Particles - With Focus on Electrons and Positrons -
© Jimoid.com 2005 Ionising Radiation There are two types of radiation; ionising and non-ionising. Radiation Ionising Non-ionising Indirectly ionising (neutral.
Monday, Oct. 16, 2006PHYS 3446, Fall 2006 Jae Yu 1 PHYS 3446 – Lecture #11 Monday, Oct. 16, 2006 Dr. Jae Yu 1.Energy Deposition in Media Total Electron.
P ARTICLE D ETECTORS Mojtaba Mohammadi IPM-CMPP- February
Interactions of Particles with Matter
Wednesday, Oct. 18, 2006PHYS 3446, Fall 2006 Jae Yu 1 PHYS 3446 – Lecture #12 Wednesday, Oct. 18, 2006 Dr. Jae Yu 1.Particle Detection Ionization Detectors.
Gamma ray interaction with matter A) Primary interactions 1) Coherent scattering (Rayleigh scattering) 2) Incoherent scattering (Compton scattering) 3)
Chapter 5 Interactions of Ionizing Radiation. Ionization The process by which a neutral atom acquires a positive or a negative charge Directly ionizing.
Particle Detectors for Colliders Robert S. Orr University of Toronto.
Interactions of Hadrons and Hadronic Showers
PHYSICS 225, 2 ND YEAR LAB NUCLEAR RADIATION DETECTORS G.F. West Thurs, Jan. 19.
R.S. Orr 2009 TRIUMF Summer Institute
INTERACTIONS OF RADIATION WITH MATTER. twCshttp:// twCs
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
DE/dx in ATLAS TILECAL Els Koffeman Atlas/Nikhef Sources: PDG DRDC (1995) report RD34 collaboration CERN-PPE
Interactions of Ionizing Radiation
Wednesday, Mar. 2, 2005PHYS 3446, Spring 2005 Jae Yu 1 PHYS 3446 – Lecture #11 Wednesday, Mar. 2, 2005 Dr. Jae Yu 1.Energy Deposition in Media Photon energy.
PHYS 3446 – Lecture #13 Energy Deposition in Media
PHYS 3446 – Lecture #11 Energy Deposition in Media Particle Detection
Lecture 8 – Detectors - II
Chapter 5 Interactions of Ionizing Radiation
Calorimeters at CBM A. Ivashkin INR, Moscow.
Methods of Experimental Particle Physics
PHYS 3446 – Lecture #14 Energy Deposition in Media Particle Detection
PAN-2013: Radiation detectors
Calorimeters in HEP Add hermiticity CC event - calibration
Experimental Particle Physics
Scintillation Counter
When this happens... We see this... 12/6/2018 Steve Wotton.
Experimental Particle Physics
PHYS 3446 – Lecture #16 Monday ,April 2, 2012 Dr. Brandt
Particles going through matter
PHYS 3446 – Lecture #17 Wednesday ,April 4, 2012 Dr. Brandt
PHYS 3446 – Lecture #13 Energy Deposition in Media
PHYS 3446 – Lecture #14 Energy Deposition in Media Particle Detection
Presentation transcript:

Calorimeters Purpose of calorimeters EM Calorimeters Hadron Calorimeters Graduate lectures HT '08 T. Weidberg

EM Calorimeters Measure energy (direction) of electrons and photons. Identify electrons and photons. Reconstruct masses eg Z  e+ e- p0 g g H gg Resolution important: Improve S/N Improve precision of mass measurement. Graduate lectures HT '08 T. Weidberg

EM Calorimeters Electron and photon interactions in matter Resolution Detection techniques Sampling calorimeters vs all active Examples Graduate lectures HT '08 T. Weidberg

12.2 Charged particles in matter (Ionisation and the Bethe-Bloch Formula, variation with bg) m+ can capture e- Emc = critical energy defined via: dE/dxion.=dE/dxBrem. Graduate lectures HT '08 T. Weidberg

Charged particles in matter (Bremsstrahlung = Brakeing Radiation) Due to acceleration of incident charged particle in nuclear Coulomb field Radiative correction to Rutherford Scattering. Continuum part of x-ray emission spectra. Emission often confined to incident electrons because radiation ~ (acceleration)2 ~ mass-2. Lorentz transformation of dipole radiation from incident particle centre-of-mass to laboratory gives narrow (not sharp) cone of blue-shifted radiation centred around cone angle of =1/. Radiation spectrum very uniform in energy. Photon energy limits: low energy (large impact parameter) limited through shielding of nuclear charge by atomic electrons. high energy limited by maximum incident particle energy. Ze e- g Graduate lectures HT '08 T. Weidberg

12.2 Charged particles in matter (Bremsstrahlung  EM-showers, Radiation length) dT/dx|Brem~T (see Williams p.247)  dominates over dT/dx|ionise ~ln(T) at high T. For electrons Bremsstrahlung dominates in nearly all materials above few 10 MeV. Ecrit(e-) ≈ 600 MeV/Z If dT/dx|Brem~T  dT/dx|Brem=T0exp(-x/X0) Radiation Length X0 of a medium is defined as: distance over which electron energy reduced to 1/e. X0~Z2 approximately. Bremsstrahlung photon can undergo pair production (see later) and start an em-shower (or cascade) Length scale of pair production and multiple scattering are determined by X0 because they also depend on nuclear coulomb scattering.  The development of em-showers, whether started by primary e or  is measured in X0. Graduate lectures HT '08 T. Weidberg

Very Naïve EM Shower Model Simple shower model assumes: E0 >> Ecrit only single Brem-g or pair production per X0 The model predicts: after 1 X0, ½ of E0 lost by primary via Bremsstrahlung after next X0 both primary and photon loose ½ E again until E of generation drops below Ecrit At this stage remaining Energy lost via ionisation (for e+-) or compton scattering, photo-effect (for g) etc. Abrupt end of shower happens at t=tmax = ln(E0/Ecrit)/ln2 Indeed observe logarithmic depth dependence Graduate lectures HT '08 T. Weidberg

13.1 Photons in matter (Overview) Rayleigh scattering Coherent, elastic scattering of the entire atom (the blue sky) g + atom  g + atom dominant at lg>size of atoms Compton scattering Incoherent scattering of electron from atom g + e-bound  g + e-free possible at all Eg > min(Ebind) to properly call it Compton requires Eg>>Ebind(e-) to approximate free e- Photoelectric effect absorption of photon and ejection of single atomic electron g + atom  g + e-free + ion possible for Eg < max(Ebind) + dE(Eatomic-recoil, line width) (just above k-edge) Pair production absorption of g in atom and emission of e+e- pair Two varieties: g + nucleus  e+ + e- + nucleus (more momentum transfer to nucleusdominates) g + Z atomic electrons  e+ + e- + Z atomic electrons both summarised via: g + g(virtual)  e+ + e- Needs Eg>2mec2 Nucleus has to recoils to conserve momentum  coupling to nucleus needed  strongly Z-dependent crossection Graduate lectures HT '08 T. Weidberg

13.1 Photons in matter (Note on Pair Production) Compare pair production with Bremsstrahlung Ze e- e-* g Bremsstrahlung Ze e-* e- g Pair production Typical Lenth = Pair Production Length L0 Typical Lenth = Radiation Length X0 Very similar Feynman Diagram Just two arms swapped L0=9/7 X0 Graduate lectures HT '08 T. Weidberg

13.1 Photons in matter (Crossections) Lead Carbon R  Rayleigh PE  Photoeffect C  Compton PP  Pair Production PPE  Pair Production on atomic electrons PN  Giant Photo-Nuclear dipole resonance Graduate lectures HT '08 T. Weidberg

Transverse Shower Size Moliere radius = 21 MeV X0/Ec Electrons Photons Graduate lectures HT '08 T. Weidberg

Sampling vs All Active Sampling: sandwich of passive and active material. eg Pb/Scintillator. All active: eg Lead Glass. Pros/cons Resolution Compactness  costs. Graduate lectures HT '08 T. Weidberg

Detection Techniques Scintillators Ionisation chambers Cherenkov radiation (Wire chambers) (Silicon) Graduate lectures HT '08 T. Weidberg

Organic Scintillators (1) Organic molecules (eg Naphtalene) in plastic (eg polysterene). excitation  non-radiating de-excitation to first excited state  scintillating transition to one of many vibrational sub-states of the ground state. Graduate lectures HT '08 T. Weidberg

Organic Scintillators (2) gives fast scintillation light, de-excitation time O(10-8 s) Problem is short attenuation length. Use secondary fluorescent material to shift l to longer wavelength (more transparent). Light guides to transport light to PMT or Wavelength shifter plates at sides of calorimeter cell. Shift blue  green (K27)  longer attenuation length. Graduate lectures HT '08 T. Weidberg

Inorganic Scintillators (1) eg NaI activated (doped) with Thallium, semi-conductor, high density: r(NaI=3.6),  high stopping power Dopant atom creates energy level (luminescence centre) in band-gap Excited electron in conduction band can fall into luminescence level (non radiative, phonon emission) From luminescence level falls back into valence band under photon emission this photon can only be re-absorbed by another dopant atom  crystal remains transparent Graduate lectures HT '08 T. Weidberg

Inorganic Scintillators (2) High density of inorganic crystals  good for totally absorbing calorimetry even at very high particle energies (many 100 GeV) de-excitation time O(10-6 s) slower then organic scintillators. More photons/MeV  Better resolution. PbWO4. fewer photons/MeV but faster and rad-hard (CMS ECAL). Graduate lectures HT '08 T. Weidberg

Detectors (1) Photomultiplier: primary electrons liberated by photon from photo-cathode (low work function, high photo-effect crossection, metal, hconversion≈¼ ) visible photons have sufficiently large photo-effect cross-section acceleration of electron in electric field 100 – 200 eV per stage create secondary electrons upon impact onto dynode surface (low work function metal)  multiplication factor 3 to 5 6 to 14 such stages give total gain of 104 to 107 fast amplification times (few ns)  good for triggers or veto’s signal on last dynode proportional to #photons impacting PMT Graduate lectures HT '08 T. Weidberg

Detectors (2) APD (Avalanche Photo Diode) solid state alternative to PMT strongly forward biased diode gives “limited” avalanche when hit by photon Graduate lectures HT '08 T. Weidberg

13.2 Detectors Ionisation Chambers Used for single particle and flux measurements Can be used to measure particle energy up to few MeV with accuracy of 0.5% (mediocre) Electrons more mobile then ions  medium fast electron collection pulse O(ms) Slow recovery from ion drift Graduate lectures HT '08 T. Weidberg

Resolution Parameterise resolution as Sampling fluctuations for sandwich calorimeters. Statistical fluctuations eg number of photo-electrons or number of e-ion pairs. Electronic noise. Others Non-uniform response Calibration precision Dead material (cracks). Material upstream of the calorimeter. Lateral and longitudinal shower leakage Parameterise resolution as a Statistical b noise c constant Graduate lectures HT '08 T. Weidberg

Classical Pb/Scintillator Graduate lectures HT '08 T. Weidberg

Lead Glass All active Pb Glass Graduate lectures HT '08 T. Weidberg

BGO Higher resolution Graduate lectures HT '08 T. Weidberg

Liqiuid Argon Good resolution eg NA31. Graduate lectures HT '08 T. Weidberg

Fast Liquid Argon Problem is long drift time of electrons (holes even slower). Trick to create fast signals is fast pulse shaping. Throw away some of the signal and remaining signal is fast (bipolar pulse shaping). Can you maintain good resolution and have high speed (LHC)? Graduate lectures HT '08 T. Weidberg

Cu/kapton electrodes for HV and signal Accordion Structure Lead plates Cu/kapton electrodes for HV and signal Liquid Argon in gaps. Low C and low L cf cables in conventional LAr calorimeter. Graduate lectures HT '08 T. Weidberg

Bipolar Pulse Shaping Graduate lectures HT '08 T. Weidberg

Graduate lectures HT '08 T. Weidberg

ATLAS Liquid Argon Resolution Stochastic term ~ 1/E1/2. Noise ~ 1/E Constant (non-uniformity over cell, calibration errors). Graduate lectures HT '08 T. Weidberg

Calibration Electronics calibration For scintillators ADC counts to charge in pC. How? For scintillators Correct for gain in PMT or photodiode. How? Correct for emission and absorption in scintillator and light guides. How ? Absolute energy scale. Need to convert charge seen pC  E (GeV). How? Graduate lectures HT '08 T. Weidberg

Hadron Calorimeters Why you need hadron calorimeters. The resolution problem. e/pi ratio and compensation. Some examples of hadron calorimeters. Graduate lectures HT '08 T. Weidberg

Why Hadron Calorimeters Measure energy/direction of jets Reconstruct masses (eg tbW or h bbar) Jet spectra: deviations from QCD  quark compositeness) Measure missing Et (discovery of Ws, SUSY etc). Electron identification (Had/EM) Muon identification (MIPs in calorimeter). Taus (narrow jets). Graduate lectures HT '08 T. Weidberg

Hadron Interactions Hadron interactions on nuclei produce More charged hadrons  further hadronic interactions  hadronic cascade. p0 gg EM shower Nuclear excitation, spallation, fission. Heavy nuclear fragments have short range  tend to stop in absorber plates. n can produce signals by elastic scattering of H atoms (eg in scintillator) Scale set by lint (eg = 17 cm for Fe, cf X0=1.76 cm)  next transparency Graduate lectures HT '08 T. Weidberg

Graduate lectures HT '08 T. Weidberg

Resolution for Hadron Calorimeters e/pi ≠ 1  fluctuations in p0 fraction in shower will produce fluctuations in response (typically e/pi >1). Energy resolution degraded and no longer scales as 1/E1/2 and response will tend be non-linear because p0 fraction changes with E. Graduate lectures HT '08 T. Weidberg

e/h Response vs Energy Graduate lectures HT '08 T. Weidberg

Resolution Plots s(E)/E vs 1/E1/2. Fe/Scint (poor). ZEUS U/scint and SPACAL (good). Graduate lectures HT '08 T. Weidberg

Compensation (1) Tune e/pi ~= 1 to get good hadronic resolution. U/Scintillator (ZEUS) Neutrons from fission of U238 elastic scatter off protons in scintillator  large signals  compensate for nuclear losses. Trade off here is poorer EM resolution. Graduate lectures HT '08 T. Weidberg

Compensation (2) Fe/Scintillator (SPACAL) Neutrons from spallation in any heavy absorber can scatter of protons in scintillator  large signals. If the thickness of the absorber is increased greater fraction of EM energy is lost in the passive absorber. tune ratio of passive/active layer thickness to achieve compensation. Needs ratio 4/1 to achieve compensation. No use for classical calorimeter with scintillator plates (why). SPACAL: scintillating fibres in Fe absorber. Graduate lectures HT '08 T. Weidberg

Scintillator Readout Graduate lectures HT '08 T. Weidberg

1 mm scintillating fibres in Fe SPACAL 1 mm scintillating fibres in Fe Graduate lectures HT '08 T. Weidberg

Graduate lectures HT '08 T. Weidberg

Graduate lectures HT '08 T. Weidberg

Compensation (3) Software weighting (eg H1) EM component localized  de-weight large local energies Very simplified: Graduate lectures HT '08 T. Weidberg

Fine grain Fe/Scintillator Calorimeter (WA1) With weighting resolution improved. Graduate lectures HT '08 T. Weidberg

H1 Hadronic resolution with weighting Standard H1 weighting Improved (Cigdem Issever) Graduate lectures HT '08 T. Weidberg