X-Ray Techniques Francis, 2013

Slides:



Advertisements
Similar presentations
NUCP 2371 Radiation Measurements II
Advertisements

OFFLINE COMPOSITION MEASURING SENSORS
Chapter 12 Additional Analytical Methods. Analytical Methods Technique Type Technique application Subdivisions Specific application DescriptionDestruction.
D e t e c t o r s f o r H P L C.
Instrumental Chemistry
X-ray Detection and Analysis
Happyphysics.com Physics Lecture Resources Prof. Mineesh Gulati Head-Physics Wing Happy Model Hr. Sec. School, Udhampur, J&K Website: happyphysics.com.
Bragg’s Law nl=2dsinΘ Just needs some satisfaction!! d Θ l
BACKGROUND THEORY AND TERMINOLOGY FOR ELECTRON MICROSCOPY FOR CyberSTEM PRESENTATIONS.
X-Ray Astronomy Lab X-rays Why look for X-rays? –High temperatures –Atomic lines –Non-thermal processes X-ray detectors X-ray telescopes The Lab.
Ion Beam Analysis techniques:
Saeedeh Ghaffari Nanofabrication Fall 2011 April 15 1.
1 SpectroscopIC aNALYSIS Part 7 – X-ray Analysis Methods Chulalongkorn University, Bangkok, Thailand January 2012 Dr Ron Beckett Water Studies Centre &
X-ray Diffraction. X-ray Generation X-ray tube (sealed) Pure metal target (Cu) Electrons remover inner-shell electrons from target. Other electrons “fall”
Scanning Electron Microscope (SEM)
Internal – External Order We described symmetry of crystal habit (32 point groups) We also looked at internal ordering of atoms in 3-D structure (230 space.
PROVIDED BY EMAD BEHDAD SPECIALIZED PROTECTION AND CORROSION OF MATERIALS LECTURERS H.MONAJATI,PHD JAFARI,PHD ISLAMIC AZAD UNIVERSITY OF NAJAFABAD BARANCH.
Introduction Secondary electron secondary electron detector The electron beam interaction with near surface specimen atoms will make a signal which results.
X-radiation. X-rays are part of the electromagnetic spectrum. X-radiation (composed of X-rays) is a form of electromagnetic radiation. X- rays have a.
Molecular Fluorescence Spectroscopy
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Light. Photons The photon is the gauge boson of the electromagnetic force. –Massless –Stable –Interacts with charged particles. Photon velocity depends.
Atomic X-Ray Spectroscopy Chapter 12 X-ray range  Å to 100 Å Used  0.1Å to 25 Å.
ED and WD X-ray Analysis
Instrumental Chemistry Chapter 12 Atomic X-Ray Spectroscopic.
Qualitative, quantitative analysis and “standardless” analysis NON DESTRUCTIVE CHEMICAL ANALYSIS Notes by: Dr Ivan Gržetić, professor University of Belgrade.
BY SANTANU PRAMANIK(09369) HITESH KUMAR GUPTA(09320) CHANDAN SINGH(09260) SCANNING ELECTRON MICROSCOPE MATERIAL SCIENCE ASSIGNMENT.
© 2004 Pearson Education Inc., publishing as Addison-Wesley Orbital Energy and Escape Velocity orbital energy = kinetic energy + gravitational potential.
X - Rays & Crystals Characterizing Mineral Chemistry & Structure J.D. Price Characterizing Mineral Chemistry & Structure J.D. Price.
Atomic Emission Spectroscopy
III. Analytical Aspects Summary Cheetham & Day, Chapters 2, 3 Chemical Characterization of Solid-State Materials Chemical Composition: Bulk, Surface, …
Chapter 7 X-Ray diffraction. Contents Basic concepts and definitions Basic concepts and definitions Waves and X-rays Waves and X-rays Crystal structure.
Atomic Absorption Spectroscopy
Chapter 12 Atomic X-Ray Spectroscopy
Theory and Practice of Electron Microprobe Analysis Geoc 575 Nelia Dunbar Bureau Office B-101 x5783 office x5155 lab.
Scanning Electron Microscope (SEM) – Shoots a high energy beam of electrons (waves of electrons) at a target. Electron gun Focusing coil Objective lens.
Unknown at first, these photons from innershell transitions have played a vital role in materials analysis.
Quantitative Analysis Quantitative analysis using the electron microprobe involves measuring the intensities of X-ray lines generated from your unknown.
Energy Energy is a property that enables something to do work
Electron Microscopes Used to count individual atoms What can electron microscopes tell us? Morphology – Size and shape Topography – Surface features (roughness,
Scanning Electron Microscope (SEM)
The Particlelike Properties of Electromagnetics Radiation Wei-Li Chen 10/27/2014.
Energy-Dispersive X-ray Microanalysis in the TEM Anthony J. Garratt-Reed Neil Rowlands.
Other modes associated with SEM: EBIC
NANO 225 Micro/NanoFabrication Electron Microscopes 1.
Detection Limits N no longer >> N B at low concentration What value of N-N B can be measured with statistical significance? Liebhafsky limit: Element is.
Reminders for this week Homework #4 Due Wednesday (5/20) Lithography Lab Due Thursday (5/21) Quiz #3 on Thursday (5/21) – In Classroom –Covers Lithography,
Scanning capacitance microscopy
NANO 225 Intro to Nano/Microfabrication
Medical Image Analysis Interaction of Electromagnetic Radiation with Matter in Medical Imaging Figures come from the textbook: Medical Image Analysis,
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
Characterization of Nanomaterials…
SEM Scanning Electron Microscope
X-ray diffraction and minerals. Is this mineral crystalline?
X-ray microanalysis in the electron microscope
Elemental Analysis using Atomic Absorption and Emission Spectroscopy Bodhisatwa Das.
EBB 245. Materials Characterisation Lecture 3 X-ray Fluorescence Spectrometry (XRF) Dr Zainovia Lockman PPKBSM, USM (lecture presentations/notes.
Presentation on SEM (Scanning of Electron Microscope) Represented by:-Ravi Kumar Roll:- (BT/ME/1601/006)
Electron microprobe in Askja
X-ray spectroscopy Repetition, exercises and more
NANO 230 Micro/NanoFabrication
Instrument Parameters in WDXRF
Atomic Absorption Spectroscopy
Atomic Absorption Spectroscopy. Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis.
SPECTROPHOTOMETRY Applied Chemistry.
Nanocharacterization (II)
PRINCIPLE AND WORKING OF A SEMICONDUCTOR LASER
Radhabai Kale Mahila Mahavidhyalaya, Ppt. name:- x-Ray techniques
Surface analysis techniques part I
Presentation transcript:

X-Ray Techniques Francis, 2013 Electron Beam

X-rays Discovered by Roentgen, 1895 λ = 0.1 – 10 nm

Fundamental Equivalency For light, the minimum resolvable distance between 2 points: =  / NA Limiting case for light  200m or nm The smaller wavelengths of X-Rays (0.1 – 10 nm) are similar to the size of atoms (0.1 – 0.2 nm), and have energies that correspond to the energy differences between the inner atomic orbitals. Fundamental Equivalency Energy versus Wavelength of Photons E = h .  ergs per single photon E = h . c /  ergs per single photon h = Planck's constant = 1.38 10-16 erg sec

Black Body Radiation: All matter emits continuous background electromagnetic radiation whose energy is a function of its temperature. Total emitted radiant energy: Etotal =  . T4 = ergs/sec/m2 = Stefan-Boltzmann constant = 5.672  10-16 erg/K Eλ = 2hc2/λ5×1/(e(hc/λ(T-1)) Energy of most abundant photon: E = hm = hc/m  3 .  . T = Boltzmann factor = 1.38  10-16 erg/K T = hc/3m T = (2897.8 / m) K = Wien’s Law, where m is the wavelength of the most abundant photons Our eyes are tuned to the Sun whose Photosphere is 5780 K

Characteristic Spectral Lines

Characteristic Spectral Lines

X-Ray Tubes

60 kV Rhodium K lines and continuous spectrum Rh Kα Rh K

X-Ray diffraction by atomic lattice planes of crystals Braggs Law (1912) X-Ray diffraction by atomic lattice planes of crystals n × λ = 2 × d × sin(θ)

Antigorite 2 θ degrees n × λ = 2 × d × sin(θ) Counts X-ray Diffractogram

n × λ = 2 × d × sin(θ) X-ray Diffractogram

Clay Minerals n × λ = 2 × d × sin(θ) I = illite S = smectite Chl = chlorite Q = quartz K = kaolinite Clay Minerals X-ray Diffractogram Scanning electron microscope image of a clay mineral n × λ = 2 × d × sin(θ)

n × λ = 2 × d × sin(θ)

Illite Crystallinity n × λ = 2 × d × sin(θ)

Mapping Alteration “Halos”

Chemical Analysis Characteristic Spectral Lines

emission excitation emission emission excitation emission

X-Ray Fluorescence Analysis The excitation is produced by X-rays. The advantage of XRF analysis is that it can analyze many elements down to levels of ppm. The disadvantage of XRF analysis is that X-rays are difficult to focus, and thus it is difficult to analyze small volumes. XRF is the method of choice for obtaining the chemical compositions of powdered or fused bulk rock samples.

Electron Microprobe Electrons can be focused with magnetic fields to spot sizes on the order of 1 micron or less. By using an electron beam as the excitation source, one can analyze very small spots on mineral grains, and thus investigate phenomena such as compositional zoning in crystals, partitioning of elements between coexisting phases, etc. The disadvantage of electron beam excitation is that a relatively high background radiation is created by the electrons, which makes the detection limits for most elements ~0.01 wt.%.

Interaction between the Electron Beam and Sample Surface Back-scattered electrons are those which interact with atomic nucleii electrostatically and are flung back out of the sample, in much the same way that a comet interacts gravitationally with the sun. Secondary electrons are produced by inelastic collisions of electrons from beam with valence electrons. These secondary electrons typically have lower energies than backscattered electrons. Auger electrons are produced by the interaction between the characteristic X-rays produced by an element with electrons in higher energy orbitals. Auger electrons typically have energies that are the difference between the energy of the initial electronic transition that produced the characteristic radiation and the ionization energy of the element. Bremsstrahlung X-rays are the radiation that is emitted when electrons are decelerated by a target. Accelerated charges give off electromagnetic radiation, and when the energy of the bombarding electrons is high enough, that radiation is in the X-ray region and is characterized by a continuous distribution of radiation which becomes more intense and shifts toward higher frequencies as the energy of the bombarding electrons is increased. This background radiation is the principle limitation in analyzing elements at very low concentrations with the electron microprobe.

Interaction between the Electron Beam and Sample Surface ~ 1 micron spot

WDS: Wavelength Dispersive Analysis Electron Microprobe Analysis X-Ray Fluorescence Analysis

Gas-Flow Proportional Counter The counter is a chamber containing a gas that is ionized by x-ray photons. A central electrode is charged at ~ +1700 V with respect to the conducting chamber walls, and each photon triggers a pulse-like cascade of electrons across this field. The signal is amplified and transformed into an accumulating digital count.

Energy Dispersive Analysis (EDS) In energy dispersive analysis, the dispersion and detection of X-rays is a single operation. The fluorescent X-rays emitted by the sample are directed into a solid-state detector which produces a continuous distribution of pulses, the voltages of which are proportional to the incoming photon energies. These detectors consist of a 3-5 mm thick silicon junction type p-i-n diode with a bias of ~ -1000 Volts across it. The lithium-drifted centre part forms the non-conducting i-layer. When an x-ray photon passes through, it causes a swarm of electron-hole pairs to form, and this causes a voltage pulse. The detector must be maintained at low temperature with liquid-nitrogen for the best energy resolution. P-type Si is doped with 3+cation such as Al to provide electron holes. N-type Si is doped with 5+ cation such as P to provide excess electrons. I-type intrinsic semiconductor The electrical pulses generated by the detector are processed by amplifiers and significant computer power is required to correct for pulse-pile up and for extraction of peaks from poorly-resolved spectra.

EDS Olivine Diopside Hornblende (Mg,Fe)2SiO4 Energy Dispersive Analysis Diopside Ca(MgFe)Si2O6 Hornblende

Wavelength dispersive analysis (WDS) is inherently more precise because of the better resolution of the spectral peaks. The disadvantage of WDS is that peaks must be occupied sequentially by the spectrometer, which slows the analytical process. With 4 spectrometers, a 10 element major analysis takes approximately ~ 4 minutes of data acquisition. WDS is the method of choice for high-quality quantitative analysis. Energy dispersive analysis (EDS) has less energy resolution, but has the advantage that all spectral lines are accumulated simultaneous, giving a complete analysis in ~ 20 seconds. EDS is the method of choice for qualitative “identification” analyses.

Quantitative Analysis Conc(I)unkn ~ (Count(IPeak)unkn -(Bkgd)) / (Count(IPeak)Std – (Bkgd))

Back-scattered electron image of olivine phenocryst Matrix Corrections Matrix effects can affect the X-ray spectrum produced in an electron microprobe analysis and have to be corrected for an accurate analysis. These matrix corrections are called ZAF corrections, in reference to their three components: atomic number (Z), absorption (A), and fluorescence (F). Atomic Number Correction X-ray emission is dependent on atomic number because of the stopping power of the target and backscattering from the target. Stopping power is the ability of a material to reduce the energy of an electron by inelastic scattering. This property is a function of A/Z, in which A is the atomic mass and Z is the atomic number. A/Z increases with increasing Z, as a result, the X-ray intensity per unit concentration increases with Z. Some of the electrons hitting the sample will be ejected back out. This process is known as backscattering and it is strongly affected by atomic number. The effect of backscattering is to decrease the X-ray intensity with increasing Z, which is opposite to the effect of stopping power. However, the backscattering effect is greater and, therefore, the overall atomic number correction follows the same trend. Minerals with high mean atomic number appear brighter in back-scattered electron images because they backscatter more electrons. Fe-rich Mg-rich Back-scattered electron image of olivine phenocryst

Back Scattered Electron Image Showing Compositional Zoning in Tourmaline

Back-scattered electron image of zoned clinopyroxene phenocryst with superimposed chemical analysis of Al content and Mg# (Mg/(Mg+Fe))

Absorption Correction X-rays are generated throughout the analytical volume during a probe analysis. Those X-rays produced at depth must pass through a certain distance within the sample and risk being absorbed, reducing the X-ray signal of the element of interest. Fluorescence Correction The critical excitation energy (Ec) of an element is the energy threshold needed to dislodge inner electrons and generate characteristic X-rays. In addition to the incident electrons, however, X-rays from the ionization of elements with higher Ec will also ionize atoms of elements with lower Ec, whose own characteristic X-ray emission lines will then be enhanced. There is also fluorescence caused by the X-ray continuum or continuous X-ray background emission produced by electron deflections. As an electron passes near an atomic nucleus, it may be slowed by the electric field of the nucleus, causing a quantum jump to a lower energy state and the emission of more X-rays.