Understanding of Harmonics in Power Distribution System

Slides:



Advertisements
Similar presentations
“Power Factor” In Transmission System
Advertisements

ACTIVE POWER FILTER FOR POWER COMPENSATION
Interharmonics IEEE T&D Show New Orleans Panel Session PN13 Non-periodic Currents: Causes,
Chapter 12 Power Amplifiers
Grid Connect Inverters NUER 19
Rama Arora, Physics Department PGGCG-11, Chandigarh
Beckett Energy Systems
EE369 POWER SYSTEM ANALYSIS
Chapter 11 AC Power Analysis
Since Therefore Since.
High Frequency Distortion in Power Grids due to Electronic Equipment Anders Larsson Luleå University of Technology.
Copyright© Voltimum Experts – not to be reproduced without prior consent of Voltimum UK Voltimum Expert Topic – Power Harmonics.
QUALITY & TECHNOLOGY HARMONIC PROBLEMS IN CAPACITOR BANKS.
1 POWER QUALITY -- Bhanu Bhushan -- June, How close is the supply voltage waveform to sinusoidal, and how close are the supply voltage and frequency.
Mike Thornton National Sales Manager
Chapter 12 Transformers. Chapter 12 Transformers.
Lecture 2 Complex Power, Reactive Compensation, Three Phase Dr. Youssef A. Mobarak Department of Electrical Engineering EE 351 POWER SYSTEM ANALYSIS.
Ch8 Inverters (converting DC to AC)
EEEB443 Control & Drives Controlled Rectifier DC Drives By
QUALITY AND TECHNOLOGY
Chapter 4 DC to AC Conversion (INVERTER)
EMC in Electrical Power Systems Frithiof Jensen Power System Engineer November 12, 2013.
2010 ASHRAE Rocky Mountain Chapter VFD Fundamentals April 16, 2010 Jeff Miller - ABB © ABB Month DD, YYYY | Slide 1 1.
© Copyright 2008 ABB. All rights reserved /29/2008 Results-Driven Roadshow Cincinnati, 2008 Common Cures for Harmonics Larry Stanley RSE,Nashville,TN.
Chapter 12 RL Circuits.
ELECTRIC DRIVES Ion Boldea S.A.Nasar 1998 Electric Drives.
EXPERIMENTAL STUDY AND COMPARATIVE ANALYSIS OF TRANSFORMER HARMONIC BEHAVIOUR UNDER LINEAR AND NONLINEAR LOAD CONDITIONS.
Sinusoidal Steady-State Power Calculations
Dry type transformers Zaragoza Traction application
Chapter 4 DC to AC Conversion (INVERTER)
Understanding of Harmonics in Power Distribution System
Power Engineering Society Chicago Chapter Reactive Power: Sources and Solutions 12 February 2003 David E. Mertz, PE Burns & McDonnell Engineers, Inc.
POWER SUPPILES LECTURE 20.
ISA Northern California Section, South Bay October 14, 2003 Craig Chidester
Introduction In recent years, harmonics are considered as one of the most essential problems in the industrial power distribution networks. The problem.
Fundamentals of Electric Circuits Chapter 11
F. Ferrandis_SP_ALPHA 2_BLOCK 2_Paper 35_Presentation Barcelona May POWER FACTOR CORRECTION WITHIN INDUSTRIAL SITES EXPERIENCES REGARDING.
Power Distribution Harmonics Case Study of 285-3F Chiller Plant Michael W. Harmon Principle Engineer Savannah River Nuclear Solutions, LLC Savannah River.
ET3380 Principles and Methods of Electric Power Conversion David Morrisson MS,MBA Week 1.
POWER FACTOR CORRECTION
PQSynergy TM 2011 Harmonic Assessment of PEA North1, Chiangmai’s Customers in North Industrial Estate Chotepong Pongsriwat. M.Eng(EE) Chief of Power.
2. Terms and definitions1 # Terms and Definitions # Voltage Sags and Interruptions.
7154 VFD Presentation #2 May 2002 Paul Weingartner.
Applied Harmonics Control of Harmonics
POWER QUALITY.
Voltimum Expert Topic – Power Harmonics. What are Harmonics? They are waveforms with frequencies that are multiples of the fundamental frequency (Typically.
Harmonics and PFC The love story By Pol Nisenblat.
8-1 School of Electrical Systems Engineering ABD RAHIM 2008 EET421 Power Electronic Drives - DC to AC converter / Inverter Abdul Rahim Abdul Razak.
1 POWER QUALITY -- Bhanu Bhushan -- April, Simple examples around us : Ceiling fan regulators Tube lights Lap-tops & peripherals Domestic inverters.
© 2003 Eaton Corporation. All rights reserved. Understanding Harmonics Richard Molloy Technology Sales Manager, Power Quality.
A common 400 Hz AC Power Supply Distribution System for CMS FEE. Authors C. Rivetta– Fermilab. F. Arteche, F. Szoncso, - CERN.
LECTURE 26 Controlled Rectifiers Dr. Rostamkolai ECE 452 Power Electronics 1.
Signal Analyzers. Introduction In the first 14 chapters we discussed measurement techniques in the time domain, that is, measurement of parameters that.
7/08/2002PP.AFD.07 Harmonic Quality1 of 49 Yaskawa Electric America Harmonic Currents, Voltages and Your Building Power System.
7/15/2002PP.AFD.081 of 28 Power Quality Considerations When Applying Adjustable Frequency Drives Explanations and Various Countermeasures.
J.PRAKASH.  The term power quality means different things to different people.  Power quality is the interaction of electronic equipment within the.
Power Quality Issues Power Electronics Group.
REVIEW OF CFL AND ITS HARMONIC IMPACT ON ELECTRICAL DISTRIBUTION SYSTEM Guide: Mr. Rijo Rajan, prepared by: Merin Lukose Lecturer, S7 EEE EEE department.
Effects of Harmonics on Capacitors Electrical System
PHASE CONTROLLED CONVERTERS
HARMONIC MITIGATION USING PASSIVE FILTERS
Yaskawa Electric America on Variable Torque Loads
AC to DC Converters Outline 2.1 Single-phase controlled rectifier
Power System Harmonics
Dr. Unnikrishnan P.C. Professor, EEE
Five level diode clapmed inverter
Power Electronic Drives - DC to AC converter / Inverter
ECE 333 Green Energy Systems
AC Drives Dr. Adel A. El-Samahy Department of Electrical Engineering University of Helwan.
Presentation transcript:

Understanding of Harmonics in Power Distribution System Dr. Adel. M. Sharaf Department of Electrical & Computer Engineering University of New Brunswick

Outline Power System Harmonics? Why Harmonics are Troublesome? Nonlinear Loads Producing Harmonic Currents Harmonic Distortion? Negative Effects of Sustained Harmonics Mitigation of the Effects of Harmonics Evaluation of AC Power System Harmonics? Conclusions References 2/23/2006 EE 6633 Seminar 1

What are Power System Harmonics? Harmonic: a mathematical definition, generally used when talking about Integral orders of Fundamental frequencies Power system harmonics: currents or voltages with frequencies that are integer multiples (h=0,1,2,…N) of the fundamental power frequency [1] 1st harmonic: 60Hz 2nd harmonic: 120Hz 3rd harmonic: 180Hz Figure: 1 [2] 2/23/2006 EE 6633 Seminar 1

How are Harmonics Produced ? Power system harmonics: presenting deviations from a perfect sinusoidal-waveform (voltage or current waveform). The distortion comes from a Nonlinearity caused by saturation, electronic-switching and nonlinear electric loads, Inrush/Temporal/Arc/Converter/Limiter/Threshold Type Loads. Figure: 2 [1] 2/23/2006 EE 6633 Seminar 1

Why Bother about Harmonics? 50-60% of all electrical Ac Systems in North America operate with non-linear type loads Power-Quality-PQ Issues & Problems Damage to Power Factor Correction capacitors Waveform Distortion can create SAG/SWELL/NOTCHING/RINGING/… All can cause damage effects to consumer loads and power systems due to Over-Current/Over-Voltage or Waveform Distortion Additional Power/Energy Losses 2/23/2006 EE 6633 Seminar 1

Loads Producing Harmonic Currents Electronic lighting ballasts/Controls Adjustable speed Motor-Drives Electric Arc Welding Equipment Solid state Industrial Rectifiers Industrial Process Control Systems Uninterruptible Power Supplies ( UPS )systems Saturated Inductors/Transformers LAN/Computer Networks 2/23/2006 EE 6633 Seminar 1

Current vs. Voltage Harmonics Harmonic current flowing through the AC Power System impedance result in harmonic voltage-drop at the load bus and along the Feeder!! Figure: 3 [3] 2/23/2006 EE 6633 Seminar 1

How to Quantify Harmonic Distortion? Total Harmonic Distortion-THD: the contribution of all harmonic frequency Currents/Voltages to the fundamental current. [3] The level of THD-for Current or Voltage is directly related to the frequencies and amplitudes of the Offending Quasi-Steady State persistent Harmonics. Individual Distortion Factor-(DF)-h quantify Distortion at h –harmonic-order 2/23/2006 EE 6633 Seminar 1

Calculation of THD (Eq-1) THD: Ratio of the RMS of the harmonic content to the RMS of the Fundamental [3] (Eq-1) Current THD-I (Eq-2) Voltage THD-V (Eq-3) 2/23/2006 EE 6633 Seminar 1

Negative Effects of Harmonics Overheating and premature failure of distribution transformers [1] Increasing iron and copper losses or eddy currents due to stray flux losses Overheating and mechanical oscillations in the motor-load system [1] Producing rotating magnitude field, which is opposite to the fundamental magnitude field. Overheating and damage of neutral ground conductors [2] Trouble sustained type Harmonics: 3rd, 9th, 15th … A 3-phase 4-wire system: single phase harmonic will add rather than cancel on the neutral conductor Malfunction/Mal-Operation of Sensitive Tele-control and Protection Relaying 2/23/2006 EE 6633 Seminar 1

Negative Effects of Harmonics (cont’ d) False or spurious Relay operations and trips of circuit breakers [2] Failure of the Firing/Commutation circuits, found in DC motor-drives and AC drives with silicon controlled rectifiers (SCR-Thyristor) [1] Mal-Operation instability of voltage regulator [1] Power factor correction capacitor failure [1] Reactance (impedance)-Zc of a capacitor bank decreases as the frequency increases. Capacitor bank acts as a sink for higher harmonic currents. The System-Series and parallel Resonance can cause dielectric failure or rupture the power factor correction capacitor failure due to Over-Voltages & Over-Currents. 2/23/2006 EE 6633 Seminar 1

Harmonics and Parallel Resonance Circuit Harmonic currents produced by variable speed motor-drives: can be amplified up to 10-15 times in parallel resonance circuit formed by the capacitance bank and network inductance [5] Amplified/intensified harmonic currents: leading to internal overheating of the capacitor unit. Higher frequency currents: causing more losses than 60hz currents having same amplitude Figure 4: Parallel resonance circuit and its equivalent circuit [5] 2/23/2006 EE 6633 Seminar 1

Harmonics and Series Resonance Circuit The voltage of upstream AC Network can be also distorted due to series/parallel resonance formed by capacitance of the capacitor bank and System/load inductance : Ca cause high harmonic current circulation through the capacitors [5] Parallel Resonance can also lead to high voltage distortion. Figure 5: Series resonance circuit and its equivalent circuit [5] 2/23/2006 EE 6633 Seminar 1

Measure Equipments of Harmonics Digital Oscilloscope: Wave shape, THD and Amplitude of each harmonic “True RMS” Multi-Meter: Giving correct readings for distortion-free sine waves and typically reading low when the current waveform is distorted Use of Harmonic Meters-Single Phase or three Phase Figure 6: “True RMS” Multi-Meter [3] 2/23/2006 EE 6633 Seminar 1

Standards for Harmonics Limitation IEEE/IEC IEEE 519-1992 Standard: Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems (Current Distortion Limits for 120v-69kv DS) Table 1: Current Harmonic Limits [4] Ratio Iscc / Iload Harmonic odd numbers (<11) numbers (>35) THD-i < 20 4.0 % 0.3 % 5.0 % 20 - 50 7.0 % 0.5 % 8.0 % 50 - 100 10.0 % 0.7 % 12.0 % >1000 15.0 % 1.4 % 20.0 % 2/23/2006 EE 6633 Seminar 1

Standard of Harmonics Limitation (cont’d) IEEE 519-1992 Standard: Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems (Voltage Distortion Limits) Table 2: Voltage Harmonic Limits [4] Bus Voltage Voltage Harmonic limit as (%) of Fundamental THD-v (%) <= 69Kv 3.0 5.0 69 - 161Kv 1.5 2.5 >= 161 Kv 1.0 2/23/2006 EE 6633 Seminar 1

Mitigation Of Harmonics [1] Ranging from variable frequency motor- drive to other nonlinear loads and equipments Power System Design: Limiting the non-linear load penetration to 30% of the maximum transformer’s capacity Limiting non-linear loads to 15% of the transformer’s capacity, when power factor correction capacitors are installed. Avoiding/Detuning resonant conditions on the AC System: (Eq-4) hr = resonant frequency as a multiple of the fundamental frequency kVAsc = short circuit current as the point of study kVARc = capacitor rating at the system voltage 2/23/2006 EE 6633 Seminar 1

Mitigation the Effects of Harmonics [1] (cont’d) Delta-Delta and Delta-Wye Transformers Using two separate utility feed transformers with equal non-linear loads Shifting the phase relationship to various six-pulse converters through cancellation techniques Figure 7: Delta-Delta and Delta-Wye Transformers [1] 2/23/2006 EE 6633 Seminar 1

Mitigation the Effects of Harmonics [1] (cont’d) Isolation-Interface Transformers The potential to “voltage match” by stepping up or stepping down the system voltage, and by providing a neutral ground reference for nuisance ground faults The best solution when utilizing AC or DC drives that use SCR/GTO/SSR.. as bridge rectifiers Line Isolation-Reactors More commonly used for their low cost Adding a small reactor in series with capacitor bank forms a Blocking series Filter. Use diode bridge rectifier as a front end to avoid severe harmonic power quality problems 2/23/2006 EE 6633 Seminar 1

Mitigation the Effects of Harmonics [1] (cont’d) Harmonic-Shunt or Trap Filters: Used in applications with a high non-linear ratio to system to eliminate harmonic currents Sized to withstand the RMS current as well as the value of current for the harmonics Providing true distortion power factor correction Figure 8: Typical Harmonic Trap Filter [1] 2/23/2006 EE 6633 Seminar 1

Harmonic Trap Filters (cont’d) Tuned to a specific harmonic order such as the 5th, 7th, 11th,… etc to meet requirements of IEEE 519-1992 Standard The number of tuned filter-branches depends on the offending steady-state harmonics to be absorbed and on required reactive power level to be compensated Figure 9: Typical Filter Capacitor Bank [5] 2/23/2006 EE 6633 Seminar 1

Harmonics Filter Types [6] Isolating harmonic current to protect electrical equipment from damage due to harmonic voltage distortion Passive Filter-Low cost: Built-up by combinations of capacitors, inductors (reactors) and resistors most common and available for all voltage levels   Active Power Filter APF: Inserting negative phase compensating harmonics into the AC-Network, thus eliminating the undesirable harmonics on the AC Power Network. APF-Used only for for low voltage networks 2/23/2006 EE 6633 Seminar 1

Harmonic Filter Types (cont’d) [7] Unified Switched Capacitor Compensator USCS: The single line diagram (SLD) of the utilization (single-phase) or (three-phase- 4-wire) feeder and the connection of the Unified Switched- Capacitor Compensator (USCS) to the Nonlinear-Temporal Inrush /Arc type Loads or SMPS-Computer/LAN-Network loads. Figure 10 [7] 2/23/2006 EE 6633 Seminar 1

Harmonics Filter Types (cont’d) [7] The USCS is a switched/modulated capacitor bank using a pulse-width modulated (PWM/SPWM) Switching Strategy. The switching device uses either solid state switch SSR-(IGBT or GTO). Figure 11 [7] 2/23/2006 EE 6633 Seminar 1

Need To Evaluate System Harmonics? [1] The application of capacitor banks in systems where 20% or more of the load includes other harmonic generating equipment. The facility has a history of harmonic related problems, including excessive capacitor fuse operation or damage to sensitive metering/relaying/control equipment. During the Planning/Design stage of any facility comprising capacitor banks and nonlinear harmonic generating equipment. 2/23/2006 EE 6633 Seminar 1

When to Evaluate System Harmonics? [1] (cont’d) In facilities where restrictive Electric Power Utility Company Standards/Guidelines limit the harmonic injection back into their system to very small magnitudes. Industrial/Commercial Plant expansions that add significant harmonic generating nonlinear type equipment operating in conjunction with capacitor banks. When coordinating and planning to add any emergency standby generator as an alternate/renewable power source 2/23/2006 EE 6633 Seminar 1

Conclusions The harmonic distortion principally comes from Nonlinear-Type Loads. The application of power electronics is causing increased level of harmonics due to Switching!! Harmonic distortion can cause serious Failure/Damage problems. Harmonics are important aspect of power operation that requires Mitigation!! Over-Sizing and Power Filtering methods are commonly used to limit Overheating Effects of Sustained Harmonics. 2/23/2006 EE 6633 Seminar 1

References [1] www-ppd.fnal.gov/EEDOffice-w/Projects/CMS/LVPS/mg/8803PD9402.pdf [2] www.pge.com/docs/pdfs/biz/power_quality/power_quality_notes/harmonics.pdf [3] www.metersandinstruments.com/images/power_meas.pdf [4]http://engr.calvin.edu/PRibeiro_WEBPAGE/IEEE/ieee_cd/chapters/CHAP_9/c9toc/c9_frame.htm [5] www.nokiancapacitors.com.es/.../EN-TH04-11_ 2004- Harmonics_and_Reactive_Power_Compensation_in_Practice.pdf [6]http://rfcomponents.globalspec.com/LearnMore/Communications_Networking/RF_Microwave_Wireless_Components/Harmonic_Filters [7] A.M. Sharaf & Pierre Kreidi, POWERQ UALITYE NHANCEMEUNSTI NGA UNIFIEDSW ITCHED CAPACITOCRO MPENSATOR, CCECE 2003 - CCGEI 2003, Montreal, Mayimai 2003 0-7803-7781-8/03/$17.00 0 2003 IEEE 2/23/2006 EE 6633 Seminar 1

Question ? 2/23/2006 EE 6633 Seminar 1