Introduction to x-rays

Slides:



Advertisements
Similar presentations
RADIOGRAPHIC GRIDS.
Advertisements

Technical Aspects: the machine the image
Advanced Biomedical Imaging Lecture 3
Control of Scatter Radiation
X-Rays In Medicine Noadswood Science, 2013.
Wilhelm Conrad Röntgen
Image Reconstruction.
X-RAYS.
Chapter 11 Prime Factors.
Formation Characteristics
Advanced Biomedical Imaging Lecture 4 Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
X-Ray Interaction with Matter & Human Biology
Conventional Radiography
IMAGE FORMATION  Introduction  The Invisible and Visible Image  Image Characteristics.
Radiographic Quality Chapter 5.
{ Projection Radiography Chapter 5 (in more detail)
Ionizing Radiation – X-Ray Imaging Gerald R. Aben, MD, FACR Department of Radiology College of Osteopathic Medicine.
RADIOLOGY. NEXT GENERATION SCIENCE / COMMON CORE STANDARDS ADDRESSED! CCSS.ELA-Literacy.RST Determine the central ideas or conclusions of a text;
X-ray radiography Seminar The "geometrical" unsharpness of X-ray images is limited by finite dimension of the source, i.e. the window on.
Imaging Science FundamentalsChester F. Carlson Center for Imaging Science Medical X-ray Imaging System Imaging Science Fundamentals.
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods
Types of Radiation Interactions All or Nothing Many Small There is a finite probability per unit length that the radiation is absorbed. If not, there is.
X-Rays and CT Scans.
Unit 1 Physics Detailed Study 3.6 Chapter 15: Medical Physics.
Radiography Introduction. Objectives To describe  Properties of x-rays  Production of x-rays  Formation of radiographic image  Components of an x-ray.
8.1 PRODUCTION AND CHARACTERISTICS OF X-RAYS
FILM CASSETTES & INTENSIFYING SCREENS WEEK 9
RADIOGRAPHIC & MAMOGRAPHIC EQUIPMENT. An magnetic resonance imaging machine is one of the most popular radiology equipmentmagnetic resonance imaging.
1 Photon Interactions  When a photon beam enters matter, it undergoes an interaction at random and is removed from the beam.
5.4.1 X-Rays. (a) describe the nature of X-rays Stowmarket Physics X-rays - nature Forms of electromagnetic radiation Short wavelength High frequency.
Topic 29: Remote Sensing 29.1 Production and use of X-rays 29.2 Production and uses of ultrasound 29.3 Use of magnetic resonance as an imaging technique.
X-Ray Medical Imaging Physics – IB Objectives
DMI 261 Radiation Biology AndProtection. Unit 2 RADIATION Electromagnetic Spectrum –The frequency range of electromagnetic radiation and the photon wavelength.
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
Dr Mohamed El Safwany, MD.
Resident Physics Lectures
1 Patient Interactions 2010FINAL. 2 1.______________ 2.______________ 3.______________ 4.______________ 5.______________.
Lecture (2). 2 1.Explain how to produce x-rays and discuss its properties 2.List the basic components of the radiographic machine and identify primary.
Image Quality Radiographic Resolution.
Patient Interactions Photoelectric Classic Coherent Scatter
Exposure Factors or Prime Factors
Photon Tissue Interactions
X-rays. Electromagnetic Spectrum to 10 nm 400 to 700 nm to nm 10 to 400 nm 700 to 10 4 nm X-ray radiation was discovered by Roentgen.
Anatomy and Physiology
Radiographic Quality Visibility and Sharpness
The production of X-Rays X-Rays are produced whenever charged particles are slowed down or stopped. X-rays are generated via interactions of the accelerated.
Radiographic Grids I By Professor Stelmark.
Film Imaging Lavin: Chapter 5 CTVT: Ronnie’s snood
Course Title : Image Recording
Interaction of x-ray photons (and gamma ray photons) with matter.
Image Quality and Patient Dose. X-ray tube design - basic principles Electrons generated by thermionic emission from a heated filament (cathode) Accelerating.
Tube Exposure Factors Math Technique Contrast and Density
Radiology - Learning the Basics Dr. B. Justin William.
X-Rays Unit 5: Medical Physics. OCR Specification Learning Outcomes: Describe the nature of x-rays Describe how x-rays are produced Describe how x-rays.
Medical Physics.
X-rays By: Jacob, Akram, Cameron Science biophysics ISP.
Exposure Factors or Prime Factors
2.4.2 interaction of x-rays with matter
DR. SAMER ALWAZNI MB.CH.B., DMRD, FCABMS-RAD.
X RAYS.
X-RAY PRODUCTION AND EXPOSURE FACTORS
Radiographic Contrast
Part No...., Module No....Lesson No
X-Radiation.
Learning Objectives By the end this lesson you should…
Department of radiology divided into
Stacy Kopso, M.Ed., R.T.(R)(M)
Characteristic Radiation in Tungsten Targets Shell # of electrons Binding energy L Char M N O P Eff X-ray Energy K
What makes a Quality Image
Presentation transcript:

Introduction to x-rays

What do these words mean? Isotope Radioactivity Geiger Muller Tube Atomic mass Half life Becquerel

Learning objectives State qualitatively the differential absorption of X-rays by air, fat, other soft tissues and bone and the appearance of X-rays on film after passing through these media. • Explain techniques for improving quality of X-ray images; use of a grid, narrow beam, filtration. Describe how the use of image intensifying screens reduces dose rates.

Frequency between 1017 – 1020Hz

Why are they useful? Fractures Breast cancer Lung cancer Dental Cardiac units Airports Therapeutic

How do they work? X-rays can be used because of the differential absorption (attenuation) of the x-rays by different body tissues (such as bone and muscle). To obtain an image, a uniform beam of x-rays is transmitted through the area of interest. Bone absorbs most of the x-rays and as such, will appear white on an x-ray film; soft-tissue (such as muscle) only absorbs some of the x-rays and appears grey

How are x-rays produced X-rays are produced when a beam of energy electrons hits a metal target. When electrons collide they lose KE some of this energy is converted to x-rays but most is converted to heat

X ray beam copper anode filament heavy metal target electron beam E.H.T vacuum

X-ray attenuation Medium Attenuation Appearance on film Air Negligible Black Fat Small Dark grey Other soft tissues Grey Bone High White

Improving image quality The radiographer aims to produce: Sharp images by increasing resolution and reducing blur Good contrast by distinguishing clearly between different body materials. They can do this by use of a grid, narrow beam, filtration.

Use of a grid A grid of lead strips reduces the blurring of images caused by scattered radiation. If two crossed grids are used at right angles to each other, almost completely eliminate unwanted scatter. To prevent the grid lines appearing on the image the grid is slowly moved across the film during exposure.

Narrow beam The cross section of the x-ray beam can be controlled by the diaphragm, this is usually a pair of lead sheets at right angles to each other. Another type of beam definer is the cone. A narrow bean is preferred as random scatter increases with beam size and blurs the image

Filtration Filters reduce unwanted low-energy scatter. This increases the sharpness of the image and the contrast

Intensifying screens About 97% of the x-rays falling on a photographic film pass straight through without any interaction. The film alone is not a very sensitive method for detecting x-rays.

X-rays from patient Cassette front (plastic) Front intensifying screen Double sided film ~ 12mm Rear intensifying screen Felt padding Cassette back metal

X-rays from the patient X-ray absorbed in the fluorescent screen Visible light Front fluorescent screen Double sided film Rear fluorescent screen Far fewer a-rays pass straight through Direct film blackening by x-rays Indirect film blackening by light

Modern screens can intensify the image by up to 250 times Modern screens can intensify the image by up to 250 times. The increased image intensity then gives shorter exposure times and reduced radiation doses to the patient. However some detail is lost by diffusion of fluorescent light. Typical resolution is 0.25-0.3mm, whilst direct exposure film can give better than 0.1mm