Energy in Cloud Computing and Renewable Energy

Slides:



Advertisements
Similar presentations
© Technical University of Catalonia - Second University of Naples - Barcelona Supercomputing Center (BSC)1 Chapter x: Green Datacenter Infrastructures.
Advertisements

SAN DIEGO SUPERCOMPUTER CENTER at the UNIVERSITY OF CALIFORNIA, SAN DIEGO Green Datacenter Initiatives at SDSC Matt Campbell SDSC Data Center Services.
Data Center Design Issues Bill Tschudi, LBNL
Green Datacenters solution March 17, 2009 By: Sanjay Sharma.
Clair Christofersen Mentor – Aaron Andersen August 2, 2012
Fred Chong 290N Green Computing
Sabyasachi Ghosh Mark Redekopp Murali Annavaram Ming-Hsieh Department of EE USC KnightShift: Enhancing Energy Efficiency by.
1 Copyright © 2012, Elsevier Inc. All rights reserved. Chapter 6 Warehouse-Scale Computers to Exploit Request-Level and Data-Level Parallelism: Computer.
© 2007 IBM Corporation Steve Bowden Green Computing CTO IBM Systems & Technology Group UKISA Sustainable Computing in a Carbon Sensitive World Blue turning.
© 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Better business outcomes equal better.
Energy and heat-aware metrics for data centers Jaume Salom, Laura Sisó IREC - Catalonia Institute for Energy Research Ariel Oleksiak, Mateusz.
1 DOE Data Center Tools Suite Data Center Energy Profiler (“DC Pro”) Lawrence Berkeley National Laboratory ANCIS EYP Mission Critical Rumsey Engineers.
CIT 470: Advanced Network and System AdministrationSlide #1 CIT 470: Advanced Network and System Administration Data Centers.
Efficient Resource Management for Cloud Computing Environments Andrew J. Younge, Gregor von Laszewski, Lizhe Wang, Sonia Lopez-Alarcon, Warren Carithers.
Cooling Product Positioning
Cloud Computing Data Centers Dr. Sanjay P. Ahuja, Ph.D FIS Distinguished Professor of Computer Science School of Computing, UNF.
SEMI-THERM FEBRUARY 23, 2010 SANTA CLARA, CALIFORNIA Capturing efficiency opportunities in data centers has become a business imperative, allowing managers.
IT Equipment Efficiency Peter Rumsey, Rumsey Engineers.
Where Does the Power go in DCs & How to get it Back Foo Camp James Hamilton web: blog:
Utility-Function-Driven Energy- Efficient Cooling in Data Centers Authors: Rajarshi Das, Jeffrey Kephart, Jonathan Lenchner, Hendrik Hamamn IBM Thomas.
Measuring and Validating Attempts to Green Columbia’s Data Center October 14, 2010 Rich Hall Peter M Crosta Alan Crosswell Columbia University Information.
02/24/09 Green Data Center project Alan Crosswell.
Datacenter Power State-of-the-Art Randy H. Katz University of California, Berkeley LoCal 0 th Retreat “Energy permits things to exist; information, to.
Energy Efficient Web Server Cluster Andrew Krioukov, Sara Alspaugh, Laura Keys, David Culler, Randy Katz.
CS : Creating the Grid OS—A Computer Science Approach to Energy Problems David E. Culler, Randy H. Katz University of California, Berkeley August.
Virtual Network Servers. What is a Server? 1. A software application that provides a specific one or more services to other computers  Example: Apache.
GREEN COMPUTING CS 595 LECTURE 12 4/6/2015. GREEN HARDWARE DESIGN BEST PRACTICES SERVER LEVEL HARDWARE - MOTHERBOARD 85% of power consumed by motherboard:
CoolAir Temperature- and Variation-Aware Management for Free-Cooled Datacenters Íñigo Goiri, Thu D. Nguyen, and Ricardo Bianchini 1.
Steve Craker K-12 Team Lead Geoff Overland IT and Data Center Focus on Energy Increase IT Budgets with Energy Efficiency.
Building Sustainable MIS Infrastuctures
Green IT and Data Centers Darshan R. Kapadia Gregor von Laszewski 1.
1 Copyright © 2011, Elsevier Inc. All rights Reserved. Chapter 6 Authors: John Hennessy & David Patterson.
Data Centers - They’re Back… E SOURCE Forum September, 2007 William Tschudi
Air Conditioning and Computer Centre Power Efficiency The Reality Christophe Martel Tony Cass.
Thermodynamic Feasibility 1 Anna Haywood, Jon Sherbeck, Patrick Phelan, Georgios Varsamopoulos, Sandeep K. S. Gupta.
1 Lecture 20: WSC, Datacenters Topics: warehouse-scale computing and datacenters (Sections ) – the basics followed by a look at the future.
Energy Usage in Cloud Part2 Salih Safa BACANLI. Cooling Virtualization Energy Proportional System Conclusion.
Strata IT Training Chapter 16 Green Networking. Green Servers Power Management –Power off monitor settings –Automatic server shutdown policy Rack mounted.
DELL CONFIDENTIAL 1 GREEN IT SOLUTIONS. GREEN IS EVERYWHERE DELL CONFIDENTIAL 2.
Overview of Data Center Energy Use Bill Tschudi, LBNL
Thermal-aware Issues in Computers IMPACT Lab. Part A Overview of Thermal-related Technologies.
ThinDesk, Inc.. What is Thin Computing?  IT Industry is buzzing about Green IT, Virtualization both in the Data Centre and on the Desktop, Public / Private.
1 Data Center Energy Efficiency Metrics ASHRAE June 24, 2008 Bill Tschudi Lawrence Berkeley National Laboratory
50th HPC User Forum Emerging Trends in HPC September 9-11, 2013
Data Center Energy Efficiency Sonoma Mountain Village November 29, 2007 William Tschudi
#watitis2015 TOWARD A GREENER HORIZON: PROPOSED ENERGY SAVING CHANGES TO MFCF DATA CENTERS Naji Alamrony
Increasing DC Efficiency by 4x Berkeley RAD Lab
Accounting for Load Variation in Energy-Efficient Data Centers
Optimizing Power and Data Center Resources Jim Sweeney Enterprise Solutions Consultant, GTSI.
CIT 470: Advanced Network and System AdministrationSlide #1 CIT 470: Advanced Network and System Administration Data Centers.
Insights into Google's PUE Results Spring Published Google PUE Results.
CS203 – Advanced Computer Architecture Warehouse Scale Computing.
Data Center Energy Efficiency SC07 Birds of a Feather November, 2007 William Tschudi
Unit 2: Chapter 2 Cooling.
The Data Center Challenge
Electrical Systems Efficiency
Lecture 20: WSC, Datacenters
Green cloud computing 2 Cs 595 Lecture 15.
IT Equipment Efficiency
The University of Adelaide, School of Computer Science
Cloud Computing Data Centers
Lecture 18 Warehouse Scale Computing
IT Equipment Efficiency
Towards Green Aware Computing at Indiana University
Where Does the Power go in DCs & How to get it Back
Cloud Computing Data Centers
Lecture 18 Warehouse Scale Computing
The Greening of IT November 1, 2007.
Lecture 18 Warehouse Scale Computing
Presentation transcript:

Energy in Cloud Computing and Renewable Energy Reza Farivar

Energy in Cloud Computing Data Center as a Computer E-book by google by Luiz André Barroso and Urs Hölzle Cloud Computing – the IT solution for the 21st century Carbon Disclosure Project Study 2011

Introduction Energy Consumption of data centers is considerable 3% of total annual energy consumption in US Double from 2006 (1.5%) Growing even more Estimated by Environmental Protection Agency EPA

Cloud Computing Adoption in IT

Carbon Emission Model

Energy Savings due to Clouds CO2 savings of cloud computing compared to no cloud computing 2011-2020.

Energy Savings due to Clouds Net Energy Savings due to Cloud Computing adoption, 2011-2020

Energy infrastructure of a data center

Warehouse Scale Computers WSC a type of datacenter WSC host hardware and software for multiple organizational units or even different companies on shared resources Traditional datacenters typically host a large number of relatively small- or medium-sized applications, each running on a dedicated hardware infrastructure that is de-coupled and protected from other systems in the same facility.

Storage in WCS

Storage in WCS

Energy usage in WCS Peak power usage of one generation of WSCs deployed at Google in 2007 CPU is NOT the sole energy consumer No one subsystem dominates

Data Center Cooling CRAC unit: computer room air conditioning Datacenter raised floor with hot–cold aisle setup

Data Center Energy Efficiency DCPE: Data Center Performance Energy Defined by Green Grid

Data Center Energy Efficiency PUE (Power Usage Effectiveness): Relates to the facility the ratio of total building power to IT power, i.e. the power consumed by the actual computing equipment (servers, network equipment, etc.) 85% of current datacenters were estimated in 2006 to have a PUE of greater than 3.0 the building’s mechanical and electrical systems consume twice as much power as the actual computing load; only 5% have a PUE of 2.0

PUE of 24 Data Centers (2007)

Improving PUE (Google, 2008) Careful air flow handling: The hot air exhausted by servers is not allowed to mix with cold air, and the path to the cooling coil is very short so that little energy is spent moving cold or hot air long distances. Elevated cold aisle temperatures: The cold aisle of the containers is kept at about 27°C rather than 18–20°C. Use of free cooling: Several cooling towers dissipate heat by evaporating water, greatly reducing the need to run chillers. In most moderate climates, cooling towers can eliminate the majority of chiller runtime. Google’s datacenter in Belgium even eliminates chillers altogether, running on “free” cooling 100% of the time. Per-server 12-V DC UPS: Each server contains a mini-UPS, essentially a battery that floats on the DC side of the server’s power supply and is 99.99% efficient. These per-server UPSs eliminate the need for a facility-wide UPS, increasing the efficiency of the overall power infrastructure from around 90% to near 99%.

Data Center Energy Efficiency SPUE (Server Power Usage Effectiveness): A server’s energy conversion, ratio of total server input power to its useful power useful power: power consumed by the electronic components directly involved in the computation: motherboard, disks, CPUs, DRAM, I/O cards, excluding all losses in power supplies, VRMs, and fans. SPUE ratios of 1.6–1.8 are common in today’s servers; many power supplies are less than 80% efficient, and many motherboards use (voltage regulator modules)VRMs that are similarly inefficient, losing more than 30% of input power in electrical conversion losses. SPUE should be less than 1.2

Data Center Energy Efficiency Efficiency of computation Hardest to measure Use of benchmarks In HPC, they use LINPACK to rank supercomputers (Green 500) No similar wide-initiative for internet services Joulesort measures the total system energy to perform an out-of-core sort SPECpower_ssj2008 For server- class systems, find performance-to-power ratio of a typical business application on an enterprise Java platform

SPEC Power results (2008) Performance-to-power ratio drops as the target load decreases the system power decreases much more slowly than does performance E.g. energy efficiency at 30% load is less than half the efficiency at 100% At idle, still consuming 175W over half of the peak power consumption of the server Quad-core Xeon, 4GB RAM, 7.2K harddrive

Load vs Efficiency Relative efficiency of the top 10 entries in the SPEC power benchmark Running at 30% load vs. the efficiency at 100% ratio of idle vs. peak power

Activity Profile Average CPU utilization of 5,000 Google servers during a 6-month period Servers spend relatively little aggregate time at high load levels Most of the time is spent within the 10–50% CPU utilization range Perfect mismatch with the energy efficiency profile of modern servers (most of time being most inefficient)

Absence of Idle Servers Result high-performance, robust distributed systems software design Efficient load distribution  when load is lighter we have a lower load in multiple servers Migrate workloads and their corresponding state to fewer machines during periods of low activity can be easy when using simple replication models, when servers are mostly stateless (i.e., serving data that resides on a shared NAS or SAN storage system) Comes at a cost in terms of software complexity and energy for more complex data distribution models or those with significant state and aggressive exploitation of data locality Need for resilient distributed storage. GFS & HDFS achieve higher resilience by distributing data chunk replicas on entire cluster

Poor Energy Proportionality in SPUE The CPU contribution to system power is 50% at peak, drops to less than 30% at low activity levels  the most energy-proportional Dynamic range of 3.5X Dynamic range of memory systems, disk drives, and networking equipment is lower: 2X for memory, 1.3X for disks, and less than 1.2X for networking switches

Poor Energy Proportionality in Data Center Efficiency curves derived from tests of several server power supplies Lack of proportionality at less than 30% of the peak-rated power power supplies have significantly greater peak capacity than their corresponding computing equipment  usual to operate way below peak

Oversubsribing Can increase the overall utilization and efficiency of the datacenter Opportunities at Rack, container (PDU) and data center levels Specially at the container and cluster levels

Energy from Mobile Aspect Cloud Computing can save energy for mobile clients E.g. Game of chess State of the game can fit in a few bytes Requires much more computation