Microscopy.

Slides:



Advertisements
Similar presentations
Microscopy.
Advertisements

Microscopes SC.912.L14.4.
Pg. 5 1.Coarse Adjustment knob (F)- focuses image under lowest power. Cannot use with other lenses. 2.Fine adjustment knob (E)- used to focus images under.
Welcome to Biology. Increasing reliability A drug company wants to test the effectiveness of a new drug against asthma. How can they increase the reliability.
Microscopes and Basic Measurement How are they used to study the living environment?
MICROSCOPE. Parts of the Microscope a.Eyepiece b.Coarse Adjustment c.Fine Adjustment d.Objectives (LP, HP) e.Arm f.Stage g.Light source h.Base i.Diaphragm.
The Microscope Agricultural Biology. The Microscope Two major types of microscopes based on energy used by device: 1.Light microscope Uses visible light.
MICROSCOPE PARTS.
 The reliability of analytical data generated from chemical and physical analyses is critically dependent on three factors: 1. Validity of the analytical.
Microscope Review.
The Microscope.
Microscopes Magnification, Field of View and Estimating Size.
The Microscope.
TOPIC: Microscope AIM: What are the parts of a microscope?
The Light Microscope. The light microscope Eyepiece lens Coarse adjustment knob Fine adjustment knob Nosepiece Stage and Stage Clips Condenser Diaphragm.
Types of Microscopes Simple Microscope - contains only one lens. ex. magnifying glass Compound Light Microscope - a system of two lens that work together.
PARTS OF THE MICROSCOPE
Zee Mikrosköp No…It’s Not Real German.. The Microscope  Microscopes use a variety of lenses to magnify very small objects so we can see the details of.
Date: September 24, 2015 (double periods) Aim #8: How do scientists make detailed observations? HW: 1) Complete Article Review (Measuring Horses) 2) Textbook.
The Microscope The Microscope. The Microscope ► in the microscope and development of related biological techniques made our present knowledge of cell.
Parts of the Compound Microscope. To Slide 3To Slide 5To Slide 6.
Page 1 Page 2 Page 3 Page 4. Aim: What are the structures and functions of the Compound Microscope? I. Compound Microscope – Has more than one lens. A.
Parts of a Compound Light Microscope
All About Scopes. Labeling A Microscope Body Tube Revolving Nosepiece Objective Stage Clips Diaphragm Light Source Ocular Lens Arm Stage Course Adjustment.
Parts of a Light Microscope
Microscope Basics.
Parts of the Compound Light Microscope Directions: Copy each term and explain its function. * eyepiece * high-power objective lens (40x) * body tube *
Microscopy Lab Exercise # 1Zoo- 145 Lab Exercise # 1Zoo- 145 INTRODUCTION.
Tools of the Biologist- Name That Tool!
Unit C: Cycling of Matter in Living Systems. Aristotle (384 BC – 322 BC) He was one of the first Greek philosophers who used the Scientific Method of.
Microscope Review.
Magnification and Size
KNOW YOUR MICROSCOPE Quick Quiz 5 Press the button when you’re sure… remember to take your time as you only get one chance!
EYEPIECE: 10x BODY/EXTENSION TUBE COARSE ADJUSTMENT FINE ADJUSTMENT
The Microscope An optical instrument used for viewing very small objects invisible to the naked eye, typically magnified several hundred times.
MICROSCOPE.
Body tube. Body tube Monocular Microscope Parts & Functions Ocular = eyepiece; look into microscope here; magnifies 10 X Body tube =places exact distance.
MICROSCOPE PARTS.
Topic: Microscope Aim: How do we use the compound microscope? Do Now:
The Compound Light Microscope
Microscopy : microscope Microscopy : Investigation by means of a microscope.
Microscope Review.
Aim #11: How do scientists make measurements with a microscope?
Microscopy OBJECTIVE: STRUCTURE, FUNCTION AND
Parts and focusing Microscope Basics (1) Parts and focusing
The Light Microscope.
Mitosis Root Tip Lab Observing Cells Under the Microscope
The Microscope.
Important Unit for Microscopes
Microscopes in Depth Fall 2017
Microscope Light Microscope Electron Microscope.
MICROSCOPE.
Microscopy OBJECTIVE: STRUCTURE, FUNCTION AND
The Microscope.
Using A Compound Light Microscope
MICROSCOPE.
Measuring with a Microscope
Microscope Review.
Microscopes.
Microscopes and Basic Measurement
The Light Microscope.
Microscopes Jeopardy Review Game.
Biology The Light Microscope.
Microscopes and Basic Measurement
Introduction to Microscopes
Light Microscope Light passes through slide/specimen
Microscopes.
Microscope Review.
Aim: How do instruments and techniques help science
Do now Directions: Describe three differences between the STRUCTURES of Animal and Plant Cells. 1______________________________ 2_______________________________.
Presentation transcript:

Microscopy

Parts of the microscope Ocular lens Revolving nosepiece or turret Arm Objective lens Stage Iris wheel diaphragm Coarse focus Light source Fine focus

Using the microscope Change the magnification by Changing the objective (using the turret) and ocular lenses Change the focus by Adjusting coarse and fine focus Adjust the light or contrast by Adjusting iris wheel diaphragm (or condenser or mirror if present)

Light microscopy Can be used on living cells Maximum magnification ~ x 2000 Staining can be used to make structures more visible What can be seen? – cells and organelles

Electron microscopy Can not be used on living cells Maximum magnification x millions Staining is often used eg silver, gold What can be seen? – details of organelles, large molecules

Staining Stains are used to make some structures more visible They work by being absorbed by some molecules more than others Examples include iodine, methylene blue, eosin

Working distance This is the distance between the objective lens and your slide. The higher the magnification of the lens, the larger the lens The higher the magnification of the lens, the smaller the working distance

What you see under the microscope Everything is reversed as well as magnified

What you see under the microscope 2 If the object appears to be at the top of the slide it is really at the bottom You need to move the slide away from you If the object appears to be at the left of the slide it is really at the right You need to move the slide to the right

Diameter of field of view Distance across centre of field Measured with a minigrid Measured in micrometres (m)

Using a minigrid Each square is 1 mm by 1 mm in size The centre grid is further subdivided into 0.1 mm grid squares

Millimetres and micrometres 1 mm = 1000 m 1.5 mm = m 0.4 mm = m 2400 m = mm 350 m = mm

Millimetres and micrometres 1 mm = 1000 m 1.5 mm = 1500 m 0.4 mm = 400 m 2400 m = 2.4 mm 350 m = 0.35 mm

Magnification and field of view As magnification increases, field of view decreases by the same factor x40 x100 x400 As magnification decreases, field of view increases by the same factor

Calculating field of view when magnification changes 1 magnification x 40 magnification x 400 field of view 4000 m field of view 400 m Magnification has increased by a factor of 10 Field of view has decreased by a factor of 10

Calculating field of view when magnification changes 2 magnification x 100 magnification x 400 field of view 1600 m field of view 400 m Magnification has decreased by a factor of 4 Field of view has increased by a factor of 4

Size of objects under the microscope 1 If given a scale – 0 1 2 mm Measure object with ruler Measure scale with ruler Use scale to convert ruler measurement of object to real one Size = 0.6mm = 600 µm

Size of objects under the microscope 1 example 1.7 mm ~1.7 mm ~1200 m

Size of objects under the microscope 2 If given a field of view – Magnification x100, field of view 2000 m Measure object with ruler Measure field of view with ruler Use field of view measurement to convert ruler measurement of object to real one Size = 1000 m

Size of objects under the microscope 2 example Magnification x40, field of view 4000 m Cells take up roughly ¼ of field of view So size of each cell = 1000 m

Size of objects under the microscope 3 If given a magnification – Magnification x 200 Measure object with ruler Divide size by magnification factor to get real size Size = 4cm ÷ 200 = 0.02 cm = 0.2 mm = 200 m

Size of objects under the microscope 3 example Magnification x100, field of view for x400 = 350 m Field of view for x100 = 1400 m Cell is about ½ of field of view = 750m

Magnification and field of view If field of view at x100 is 2000 m, then Field of view at x400 = Field of view at x40 = If field of view at x400 = 250 m, then Field of view at x100 =

Magnification and field of view If field of view at x100 is 2000 m, then Field of view at x400 = 2000 ÷ 4 = 500 m Field of view at x40 = 500 x 10 = 5000 m If field of view at x400 = 250 m, then Field of view at x100 = 250 x 4 = 1000 m Field of view at x40 = 250 x 10 = 2500 m

How big are these? 1. Magnification x100, field of view 1600 m

How big are these? 1. Magnification x100, field of view 1600 m ~2 fit across field so ~800 m 2. Magnification x400, field of view 200 m ~5 fit across field so ~40 m