International Vision Correction Research Centre

Slides:



Advertisements
Similar presentations
Anterior Segment OCT Angle and Vault Analysis After Implantable Collamer Lens  Implantation in Patients With High Myopia Arturo Ramirez-Miranda M.D. Alejandro.
Advertisements

SELECTION of PATIENTS PIOLs António Marinho, MD PhD Departamento de Cirurgia Refractiva Hospital Arrábida PORTO PORTUGAL.
Swept Source Optical Coherence Tomography for Evaluation of Posterior Corneal Changes after Refractive Surgery Dr. Tommy Chung Yan Chan Dr. Vishal Jhanji.
A simple and accurate method of alignment for toric intraocular lens implantation using anterior segment optical coherence tomography (OCT). Kazuno Negishi,
Eugene Ng, Arthur B. Cummings, Patrick P. Collins, Alexander V. Goncharov, Diana Bogusevschi, Chris Dainty, Michael C. Mrochen. The authors of this paper.
Long-Term Follow-Up of Toric Intraocular Lens Implantation for Keratoconus Alejandro Navas, MD, MSc, Martha Jaimes, MD, Jesús Cabral, MD, Arturo Ramirez.
V. S. Liarakos, K. van Dijk, L. Ham, L. Baydoun and G.R.J. Melles Anterior Chamber vs Posterior Chamber IOL in DMEK for Pseudophakic Bullous Keratopathy.
Purpose We studied the interdevice agreement of three systems in the different measurements of the corneal and anterior segment biometric parameters. The.
Anterior Chamber Depth, Iridocorneal Angle Width, and Intraocular Pressure Changes After Phacoemulsification: Narrow vs Open Iridocorneal Angles Huang.
David Zadok MD, Isaac Avni MD
Visualized light paths in different multifocal
Dept. of Ophthalmology, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany. Outcome after big-bubble deep anterior lamellar keratoplasty.
Mike P. Holzer, MD Annett Mannsfeld, MSc Angela Ehmer, MSc Gerd U. Auffarth, MD International Vision Correction.
Phacoemulsification in eyes with previous anterior chamber phakic IOL surgery Walton Nosé, MD, PhD 1,2 Adriana dos Santos Forseto, MD 1 Mariana Ávila,
Hong Kong Eye Hospital Ms Frenchy Chiu Dr Victoria Wong IOL master
Seyed Javad Hashemian MD Eye Research Center Rasoul Akram Hospital Tehran University of Medical Sciences No financial interest
Khairidzan Mohd Kamal MD
A case of hypermature cataract formation following implantation of a posterior chamber phakic intraocular lens with a central hole The Catholic University.
Correlation of Change in Intraocular Pressure with Anterior Chamber Depth & Angle after Cataract Surgery as measured by Anterior Segment OCT Shilpi Pradhan,
Endothelial Keratoplasty in Patients With an Anterior Chamber Intraocular Lens: A Montreal Experience Georges M. Durr, MD 1,2 Johanna Choremis, MD, FRCSC.
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
Internal Repositioning of Posteriorly Dislocated IOL: User’s Friendly Technique The author have no financial interest in the subject matter of this poster.
Partial Coherence Interferometry Failure Rate in a Teaching Hospital Leslie A. Wei 1,2, BA, Nickolaus P. Katsoulakis 2, MD, Theodoros Filippopoulos 3,
Adriana S. Forseto1, MD Walton Nosé1,2, MD
1 P.O. dei Pellegrini; A.S.L. Napoli 1Centro 2 Dipartimento di Oftalmologia, Seconda Università degli Studi Napoli Scheimpflug topography, Scanning-Slit.
Evaluation of Corneal Tomography in Primary Pterygium Sahil Goel, MD (Presenting Author), Murugesan Vanathi MD *The authors have no financial interests.
LogMAR-Analysis of multifocal intraocular lenses: Clinical performance A. Mannsfeld, I.-J. Limberger, A. Ehmer, M.P. Holzer, G. U.Auffarth International.
Ultrasound Biomicroscopy Diagnosis of Benign Iris Cysts in Patient Presenting for Implantation of Copolymer Phakic IOL Muhammad Aman-Ullah MD Howard V.
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Comparison of visual function following piggyback implantation of Acrysof ReSTOR intraocular lenses with Tecnis multifocal ZM900 intraocular lenses. Rodrigo.
I have no financial interest in any devices or techniques discussed in this presentation.
Minimizing Risk in Visian ICL Implantation.
Toric IOLs: wavefront aberrometry and quality of life Mencucci Rita Giordano Cristina, Stiko Ermelinda, Miranda Paolo, Eleonora Favuzza, Ugo Menchini Authors.
Simulated Experiments on IOL Power Calculation Using Anterior Segment OCT Dong Hyun Jo, M.D., 1,2 Mee Kum Kim, M.D., 1,2 Won Ryang Wee, M.D. 1,2 1 Department.
Poster# P36 Comparison of Techniques of Measuring Anterior Chamber Depth and Corneal Curvature in Indian Eyes Sujata Das, MS, FRCS Anjula Kumari, B.Optom.
CORNEAL ENDOTHELIAL PROFILE AFTER FERRARA RING IMPLANTATION Leonardo Torquetti, MD, PhD Paulo Ferrara, MD, PhD Paulo Ferrara Eye Clinic Belo Horizonte.
Vinohrady Teaching Hospital, Prague, Czech Republic Vinohrady Teaching Hospital, Prague, Czech Republic M. Vokrojova MD, M. Vokrojova MD, D. Sivekova MD,
Intraocular Lens Outcomes: Comparison of Technologies and Formulas Carolina Eyecare Physicians, LLC Research Assistant Professor of Ophthalmology Storm.
Anterior segment Scheimpflug imaging for screening angle closure diseases Andrew Winegarner1,, Atsuya Miki1, Miho Kumoi1, Yuchiro Ishida1, Taku Wakabayashi1,
VERISYSE AND VERIFLEX PHAKIC IOLs FOR CORRECTION OF HIGH MYOPIA
Characteristics of Primary Angle-Closure Glaucoma Patients with Normal Intraocular Pressure at the First Visit Won Hyuk Oh1, Bum Gi Kim1, Joo Hwa Lee2.
Premium IOL May be one way to achieve the visual goals of selected patients I describe some pearls for premium IOL implantation to help ensure that we.
Postoperative Refraction and Patient Satisfaction after Bilateral Implantation of Presbyopia-Correcting Intraocular Lenses Robert Cionni, MD Financial.
Measurement of 60 kHz Femtosecond LASIK Flaps with Anterior Segment Ocular Coherence Tomography & Ultrasonic Subtraction Pachymetry Edward E. Manche, MD.
Corneal Pachymetry in Prediction of Refraction After Cataract Surgery
From: Key Developments for Partial Coherence Biometry and Optical Coherence Tomography in the Human Eye Made in Vienna Invest. Ophthalmol. Vis. Sci ;57(9):OCT460-OCT474.
Toric Topographically Customized Transepithelial, Pulsed, Very High-Fluence, Higher Energy and Higher Riboflavin Concentration Collagen Cross-Linking in.
Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation Zina Zhang MD1, Logan.
Hôpital Ophtalmique Universitaire
From: Corneal Cross-Linking in Keratoconus Using the Standard and Rapid Treatment Protocol: Differences in Demarcation Line and 12-Month Outcomes Invest.
Customized Corneal Femtosecond Laser Procedures Using
Johnson CH TAN, MBBS, MRCSEd(Ophthalmology)
Comparison of corneal powers obtained from four different devices
Poster Number: P90 Category: Intraocular Surgery (Cataract and Refractive) Optimization of IOL Power Calculation Constants: By Unit or by Surgeon? Nathaniel.
Comparison of the Visian Implantable Collamer Lens with the Verisyse Phakic Intraocular Lens in High Myopia Jigna Joshi MD Marian Macsai MD Parag Majmudar.
Comparison of Automated and Manual Measurements of Horizontal Corneal Diameter in Contact Lens Wearers Using Orbscan Eye Metrics Function and Orbscan 11z.
The authors have no financial interest
Mohamed A Guenena, MD Helga P Sandoval, MD, MSCR Kerry D Solomon, MD
Vicente J. Correa-Gomez MD, Guillermo Tapia MD, Oscar Macias Manuel MD, Alejandro Navas Perez MD, Gilberto Islas MD, Tito Ramírez-Luquin MD, Enrique O.
Roxana Ursea, MD Matthew T. Feng, MD Ovette Villavicencio, PhD
Sun Woong Kim, M.D.1, Hae Jung Sun, M.D.1,
New 3-Dimensional Scheimpflug Analysis of Cataract Density
성모병원 안센터 CHANGES IN ASTIGMATISM RELATIVE TO IOL HAPTIC INSERTION AXIS IN WITH-THE-RULE AND AGAINST-THE-RULE ASTIGMATISM PATIENTS Hyun Seung Kim, M.D.
Anand K Shah MD1 Neda Shamie MD1 Paul Phillips MD1 Mark A Terry MD1,2*
Joshua C. Teichman, MD Richard Lee, MD Andrea Butler, BSc
Khairidzan Mohd Kamal MD
Aspherical ablation profiles in excimer laser treatments
Early Experience With Anterior Chamber Phakic IOL
International Vision Correction Research Centre
Eye Clinic Day Hospital - SÃO Paulo - Brazil
Presentation transcript:

International Vision Correction Research Centre E-mail:angela.ehmer@med.uni-heidelbergd.de www.lasik-uni-hd.de Evaluation of phakic irisfixated intraocular lenses with Zeiss Visante OCT A. Ehmer, C. Foerster, M.P. Holzer, G.U. Auffarth Dept. of Ophthalmology Ruprecht-Karls-University Heidelberg Acting-chairman: G. U. Auffarth, MD The authors have no financial interests in any of the products mentioned.

Purpose, Methods & Patients Visualisation and detection of lens position of phakic intraocular lenses in the anterior chamber of the human eye. Methods Phakic irisfixated IOLs (Verisyse, AMO) were implanted to correct ametropia (Figure 1) Lens position in the anterior chamber was measured with Zeiss Visante OCT (Figure 2) ACD was measured with Zeiss IOL Master (Figure 3) and Oculus Pentacam HR (Figure 4) Data were collected 4 to 26 months postoperatively Patients 24 eyes of 12 patients, mean age of 38.1 ± 5.9 years 76 eyes of healthy patients from refractive polyclinic were enrolled in this retrospective data analysis. Mean age was 36.6 +/- 8.2 years, there were 48 female and 28 male patients. Figure 1 Figure 2 Figure 3 Figure 4 Angela Ehmer, MSc

Results I Figure 5 shows the pIOL in the anterior chamber. The distance from pIOL to corneal endothelium magnified in Figure 6 and pIOL to cristalline lens in Figure 7. Figure 7 Figure 6 Distance cornea – pIOL in mm ACD preop in mm Figure 5 A high correlation between the preoperative anterior chamber depth and the distance of the phakic IOL to corneal endothelium (r = 0.83) was found (figure 8). The deeper the anterior chamber the greater the distance between cornea and phakic IOL. Here you can see the box plots of our data. The left one shows the data of Procyon pupil sizes. There were significant differences between the illumination profiles. On the right side you see the range of pupil sizes measured with with the topographic and wavefrontanalysing devices. There are also significant differences in all devices tested. Figure 8 Angela Ehmer, MSc

Results II Figure 10 Figure 9 The mean distance between the phakic IOL and the endothelium of the cornea was 2.21 ± 0.31 mm (figure 9) The mean distance between the natural crystalline lens to the phakic IOL was 0.80 ± 0.18 mm (figure 10) High correlation was found between target refraction and refraction three months postoperatively (R = 0.98) (figure11) Here you can see the box plots of our data. The left one shows the data of Procyon pupil sizes. There were significant differences between the illumination profiles. On the right side you see the range of pupil sizes measured with with the topographic and wavefrontanalysing devices. There are also significant differences in all devices tested. Figure 11 Angela Ehmer, MSc

Conclusion The Zeiss Visante OCT is suitable to demonstrate IOL position in the anterior chamber of the eye. The data analysed showed a confident implantation without impairing the corneal endothelium over a 26 months follow up period. Literatur Konstantopoulos A, Hossain P, Anderson DF. Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis? Br J Ophthalmol. 2007 Apr;91(4):551-7. Review. Lavanya R, Teo L, Friedman DS, Aung HT, Baskaran M, Gao H, Alfred T, Seah SK, Kashiwagi K, Foster PJ, Aung T: Comparison of anterior chamber depth measurements using the IOLMaster, Scanning Peripheral Anterior Chamber depth Analyser and Anterior Segment Optical Coherence Tomography. Br J Ophthalmol. 2007 Feb 27; Rabsilber TM, Khoramnia R, Auffarth GU. Anterior chamber measurements using Pentacam rotating Scheimpflug camera.J Cataract Refract Surg. 2006 Mar;32(3):456-9. Wang L, Auffarth GU. White-to-white corneal diameter measurements using the eyemetrics program of the Orbscan topography system. Dev Ophthalmol. 2002;34:141-6. It is possible to measure pupil size with multifuncional devices however its important to know Angela Ehmer, MSc