Fig. 2 Implantation procedure for the NET probes.

Slides:



Advertisements
Similar presentations
Date of download: 6/28/2016 Copyright © 2016 SPIE. All rights reserved. Optogenetic tools and light tissue penetration: (a) schematic representation of.
Advertisements

Volume 82, Issue 6, Pages (June 2014)
Volume 96, Issue 4, Pages e2 (November 2017)
Volume 86, Issue 1, Pages (April 2015)
Benoit Tesson, Michael I. Latz  Biophysical Journal 
Ji Dai, Daniel I. Brooks, David L. Sheinberg  Current Biology 
Direct Activation of Sparse, Distributed Populations of Cortical Neurons by Electrical Microstimulation  Mark H. Histed, Vincent Bonin, R. Clay Reid 
Fig. 5 Acute loss of mitochondrial content after impact is prevented by inhibition of electron transport or critical redox events. Acute loss of mitochondrial.
Fig. 2 In vitro assessment of hESC-RPE cell sheets.
Morphology structure of the remora’s adhesive disc and our biomimetic prototype design with mechanical elements and mechanisms. Morphology structure of.
Demonstration of MT sorting by integrating the top-down design of PDMS device with the bottom-up design of MT properties. Demonstration of MT sorting by.
Volume 26, Issue 19, Pages (October 2016)
Fig. 1 Device structure, typical output performance, and cytocompatibility of BD-TENG. Device structure, typical output performance, and cytocompatibility.
Comparison of network robustness measures over a larger time window
Fig. 6 Knockdown of nestin impaired tendon repair and regeneration in a rat model of patellar tendon defect. Knockdown of nestin impaired tendon repair.
by Fei Chen, Paul W. Tillberg, and Edward S. Boyden
Biocompatibility evaluation in vivo with a mouse subcutaneous implant
Fig. 4 3D reconfiguration of liquid metals for electronics.
Fig. 5 MicroLED array with 3D liquid metal interconnects.
Fig. 2 Electronically conducting xylem wires.
Fig. 2 Reconfiguration of liquid metals into 3D structures.
Fig. 1 Characterization of the device structure.
Fig. 1 High-resolution printing of liquid metals.
Fig. 3 The electrical contact of direct-printed and reconfigured liquid metals. The electrical contact of direct-printed and reconfigured liquid metals.
Demonstration of MT sorting by integrating the top-down design of PDMS device with the bottom-up design of MT properties. Demonstration of MT sorting by.
Structural analysis of graphene-embedded FeN4 (FeN4/GN) catalysts
Fig. 4 First-principles DFT calculations.
Fig. 2 Fluidic and electrical characteristics of the wireless optofluidic system. Fluidic and electrical characteristics of the wireless optofluidic system.
Probing ferroelectricity in a metal-gated WTe2 thin film sample
Fig. 3 Bioresorbable interfaces to the optical sensors.
Fig. 4 Kinetics of dissolution and histological studies of bioresorbable optical sensors and fibers. Kinetics of dissolution and histological studies of.
Fig. 2 CdS thin films with three different shapes.
Fig. 3 Piezoresistive e-skin with interlocked microdome arrays for simultaneous detection of static pressure and temperature. Piezoresistive e-skin with.
Interactive morphogenesis in Ch-CNC droplets laden with magnetic NPs
Fig. 1 Schematics and design of the device structure.
Fig. 1 The elaborate structure, components, and actuation mechanism of the MXene-cellulose–based actuator. The elaborate structure, components, and actuation.
Fig. 1 Device structure, typical output performance, and cytocompatibility of BD-TENG. Device structure, typical output performance, and cytocompatibility.
Fig. 1 The structure of the 3DGraphene foam.
Fig. 2 Images of complex structures formed via sequential folding.
Self-powered textile for wearable electronics by hybridizing fiber-shaped nanogenerators, solar cells, and supercapacitors by Zhen Wen, Min-Hsin Yeh, Hengyu.
Fig. 2 Camera-based photothermal imaging.
Fig. 5 Recruitment of a downstream polarity complex triggered by the MT arrival. Recruitment of a downstream polarity complex triggered by the MT arrival.
The prototype and working mechanism.
Fig. 1 Operation mechanism and scanning electron microscopy images of MTC device. Operation mechanism and scanning electron microscopy images of MTC device.
Fig. 4 Structural design of an F-TENG.
Ultrahigh mobility and efficient charge injection in monolayer organic thin-film transistors on boron nitride by Daowei He, Jingsi Qiao, Linglong Zhang,
Illustration of MIS-C and the characterization of the device structure
Fig. 2 Raman characterization of CVD-grown graphene.
Fig. 2 Large-area and high-density assembly of AuNPs.
Fig. 4 Giant optical chirality.
Fig. 1 Schematic view and characterizations of FGT/Pt bilayer.
Superconducting cavity electro-optics: A platform for coherent photon conversion between superconducting and photonic circuits by Linran Fan, Chang-Ling.
Fig. 5 Probing spinal cord electrophysiology with flexible and stretchable neural probes. Probing spinal cord electrophysiology with flexible and stretchable.
Fig. 2 Structural design of an F-DSSC.
Fig. 4 Comparison of different catalyst loading methods and substrates in the cathode of a PEMEC (one is on the membrane and the other one is on the LGDL).
Fig. 4 Perovskite-infused nanoporous thin films for LEDs.
Fig. 2 Optomechanical scheme to measure photon angular momentum and optical torque in a waveguide. Optomechanical scheme to measure photon angular momentum.
Fig. 1 MIR photovoltaic detector based on b-AsP.
Fig. 2 Temperature-sensing properties of the flexible rGO/PVDF nanocomposite film. Temperature-sensing properties of the flexible rGO/PVDF nanocomposite.
Fiber patterning using microrobot-assisted wet transfer.
Fig. 3 Performance of the solid wire supercapacitors of 3D graphene-CNT fiber for energy storage. Performance of the solid wire supercapacitors of 3D graphene-CNT.
Fig. 2 Physical properties and measured responses of the sensors.
Fig. 2 Supraballs and films from binary SPs.
SEM and TEM images and photoluminescence properties of composites
Fig. 3 Global and basin-averaged sampling error compared with reconstructed temperature change. Global and basin-averaged sampling error compared with.
Fig. 1 FETs constructed from densely packed semiconducting CNT arrays.
Fig. 5 Electrical stimulation of nerve cells powered by BD-TENG.
Fig. 4 3D graphene-RACNT fiber as the counter electrode for wire-shaped DSSCs. (A) Schematic representation of wire-shaped DSSC using 3D graphene-CNT fiber.
Fig. 1 The anisotropic charge transport in the bulk and the spontaneous formation of Cu–Mo–S–based dense nanocomposites during deposition of MoS2 directly.
by Sanha Kim, Yijie Jiang, Kiera L. Thompson Towell, Michael S. H
Presentation transcript:

Fig. 2 Implantation procedure for the NET probes. Implantation procedure for the NET probes. (A) Schematic showing the temporary engaging mechanism. Arrows denote the entry site of the implantation (solid), the delivery path of the shuttle device (gray), and the path of the engaged NET probe (dashed). Inset: Zoom-in view of the dashed square highlighting that the micropost engages in the microhole on the NET probe at the end of the shuttle device. (B) Photograph of a typical carbon fiber shuttle device, with a diameter of 7 μm and a length of 3 mm, mounted at the end of a micromanipulator. Scale bar, 500 μm. Inset: Scanning electron microscopy (SEM) image of the micromilled post with a diameter of 2 μm and a height of 5 μm at the shuttle device tip. Scale bar, 2 μm. (C) Optical micrographs showing engaging holes in NET-50 (top) and NET-10 (bottom) probes with a slightly larger diameter than the post, as denoted by the arrows. (D and E) False-colored SEM images of NET-50 and NET-10 probes (green) attached on shuttle devices with a 20-μm tungsten microwire (D, purple) and a 10-μm carbon fiber (E, purple) showing their ultrasmall dimensions. Scale bars, 50 μm (D) and 20 μm (E). (F and G) Micrographs showing that both NET-50 and NET-10 probes were successfully delivered into the living mouse brain with minimal acute tissue damage. Arrows denote the delivery entry sites. Scale bars, 100 μm (F) and 50 μm (G). (H) Schematic of skull fixation that accommodates both connectors for the neural probes and a glass window allowing optical access. Not drawn to scale. (I) Photograph of a typical postsurgery mouse with implanted NET probes and a glass window mounted on top. Insets: top, image of a cable connector mounted on the skull; bottom, zoom-in view of the glass window in which the arrow denotes an implanted probe. (J) Typical unit activities recorded by eight electrodes on an implanted NET-50 probe. A high-pass filter (300 Hz) was applied. Lan Luan et al. Sci Adv 2017;3:e1601966 Copyright © 2017, The Authors