Delta Heater Introduction

Slides:



Advertisements
Similar presentations
12/2007©Copyright 2007 Desco Industries Inc Mini Zero Volt Ioniser.
Advertisements

PGS Introduction "Value Series" : Best VALUE gaming cases with the highest C/P Ratio (Cost to Performance ratio). "Professional Series – Red label" :
SITOP power facets A&D SE PS SITOP power Automation and Drives SITOP power flexi The power pack handles it all - from 3 to 52V SITOP power.
Modular Capacity - Test - System CS
Variable Frequency Drives VFD Basics
BPS12 Battery Power Supply. December 2003 Page 2 Better Than Standard UPS systems Longer battery life –unique charging scheme DC power output –instead.
Model 3000 Magnetic Lock 1500 lbs. Holding Force Fas-Trak Mounting System 12 or 24 VDC or VAC field selectable One Piece Housing Low Power Consumption.
Presentation of product. Production capacity New heater For 15 years VTS Clima Group has been a leader in industrial heating engineering. Volcano VR.
PYRO-STAG De-Icer Optimizer Controller Technical presentation 2013.
Introduction To Programmable Logic Controllers
DC Motors, Stepper Motors, H-bridges DC Motors Stepper Motors Motor Control Circuits – Relays – H-bridges.
Chapter 8 Output Modules.
Daikin Australia Pty. Limited Ducted Split Systems 2011.
OVERCURRENT PROTECTION ROADMAP P14 Committee. How did we get to where we are?? DEVICES –Fuses –PTC.
1 Air Conditioning Pressure Switches. 2 High Pressure switch Used to protect the compressor When condensing temp gets too high Reads High Side Pressure.
1Snowmaker Transfer of Snowmaker Construction Plans WSL Institute for Snow and Avalanche Research SLF Martin Schneebeli, Matthias Jaggi Davos, 27th May.
Heat Recovery Ventilator Be used with AC system, Create a healthy life.
...save energy & reduce your costs
Perfect solution for large building
2010.
THEMIS/GBO Engineering Peer Review 1 UCB, Oct. 17, 2003 Ground Based Observatories (GBO) Observatory System Design Stewart Harris - UCB.
Controls and Electrical Preferred Technologies Steve Pavis PH-DT-DI CERN Advel Power Supplies and ABB Circuit Breakers.
BAKE BROIL - SELECT PROGRAM - CONV BAKE CONV BROIL SELF CLEAN On any diagram screen, double click any of the following components to bring you to a description.
UTH-300 INSTALLATION AND MANUAL. Method of Wiring Adhesion Construction and Wiring Method #1.
High frequency solenoid valve SX10 Series
New Arrival AC032BJS-S0EE Frameless Built-in MWO Convection Function Electronic Control Design LED Retractable Knob Built-in Installation Stainless Steel.
Model A 19-inch Rack Static Transfer Switch. Why choose a model A static transfer switch? Break before make transfers Break time < ¼ Cycle Will not transfer.
18240 Element two - Components INPUTS OUTPUTS PURPOSE TYPICAL USE.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Power Electronics and Switch Mode Power Supply
The New Switch can replace all the Old Room Needed Controllers 1– Light Switches and Wall Dimmers 2– Air-conditioning Thermostat 3– Volume Control 4–
Body ElectricalModel OutlineEngineChassisBodyfor Technician 1 Contents Click a Section Tab.
FLATPACK Rev.5 September 2002 Updated versions may be available.
UTH-65A VER. CAUTIONS ! PLEASE USE THE OUTLET PREPARED BY A QUALIFIED SERVICEMAN AND MUST CONFIRM IT BEFORE APPLY[SING AN ELECTRIC CURRENT.
Last updated: 6/28/2016www.alto-shaam.com Rotisserie Training Rotisserie.
INSTApower Compact Power Supplies. INSTA POWER INSTA POWER – Primary switch-mode power supplies The trend in the range of power supplies goes more and.
Integrated Blower Packages Kaeser Integrated Blower Family.
James McIntyre VRF Training Manager V5 Key Components.
UniTrane™ Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line
Delta’s Contribution for OCP Solution 2014
UniTrane™ Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line
User Operation Presentation
Fan Coil Controller FC/S 1.1
The New C55* CPVSd 10-20hp People. Passion. Performance.
Section 6: Air-Conditioning (Heating And Humidification)
Specializing in Water-Cooled & Portable-Split Air Conditioner
Automotive Heating And Air Conditioning
SLS 518 Single Beam Safety Light Barrier Type 4
ABB i-bus® KNX Valve Drive Actuator VAA/A
ProtoDUNE SP – Slow control Status
HV Battery Assembly.
Introduction to JUII⊕Series Machine.
Air Distribution Control
Operational Temperatures
DC Inverter Air-cooled Chiller Aqua Tempo Super II Series
PLC Hardware Components.
De-Ice control devices
SHANGHAI ROTORCOMP COMPRESSOR ONLY USE.
Instant Electric Heating Tap - Wall Mount or Surface Mount
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Low Power USB Charged, Palm Sized 5 port Switch
Customer Presentation
Customer Presentation
OCP Engineering Workshop 2017
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
ACOE347 – Data Acquisition and Automation Systems
SMPS POWER PLANT SMR 48V/25A SALIENT FEATURES
DIS-200G Series Sales Guide ESPD, July 2017 V1.1.
Door Heat Exchanger: Specification
Presentation transcript:

Delta Heater Introduction 20181214

Heater Standard List 230VAC 48VDC Model Number HEH030BA HEH050BA HEH030PA HEH050PA HEH070PA HEH100PA HEH100PB Heating Capacity (W) 300 500 700 950 1000 1500 Dimensions (inch) 5.9H x 5.7W x 1.8D 6.6H x 5.7W x 2.3D 9.3H x 7.3W x 2.3D 9.4H x 7.3W x 2.2D 1.7H X 19.0W x 7.0D Dimensions (mm) 150H x 145W x 45D 167H x 145W x 100D 235H x 185W x 58D 240H x 185W x 57D 44H x 483W x 177D Rated Voltage (VDC) 220 48 Rated Current (A) 1.5 2.5 4.5 5.0 7.2 7.5 12.5 14.5 22.0 Weight (lb/kg) 3.3 / 1.5 1.1 / 0.5 5.0 / 2.3 Approvals UL, CE UL (Rack Mount)

Delta Heater Features Highest Safety Protection Over temperature protection (Mechanical temp switch, NTC sensor, and fuse) Highest Safety Protection Interior protection grate Prevent screws drop inside the heater Delta Brushless DC Motor DC motor driving control High efficiency blower Aero Dynamic 90o Air flow turn Space saving Easy Mounting HEH050PA

Heater overall Features Wall Mount Rack Mount Foot Mount Advantages Compact size Low noise Easy to install High safety LED alarm for fan and heater status (HEH100/150) Auto self-test button (HEH100/150) DC fan selected High efficiency Rotor lock shutdown & auto re-start Stable airflow Variable speed control (HEH100/150) Safety Protection Double isolation on PTC device (HEH100/150) Safety protection (mechanical temp switch, NTC sensor, and fuse) Overheat alarm Fan fail alarm heating element fail alarm

Wall Mount Heater-AC Power Item HEH100BA HEH050BA Outline dimension inch 9.3H x 7.3W x 2.3D 5.9H x 5.7W x 1.8D Heating capacity W 1000 @20°C 500 @20°C Rated voltage VDC 220 (Typ.) Rated current A 5.0 @20°C 2.5 @20°C Operating temperature °F -40~+95 Weight lb 3.3 PTC heating element Flexible signal control (on/off control) LED for fan & heater status Triple protection(mechanical temp. switch , NTC sensor & fuse ) Compact design Dual protection(mechanical temp. switch & fuse )

Wall Mount Heater-DC Power Item HEH100PA HEH050PA Outline dimension inch 9.4H x 7.3W x 2.2D 5.9H x 5.7W x 1.8D Heating capacity W 1000 @20°C 500 @20°C Rated voltage VDC 48 (Typ.) Rated current A 22.0 @20°C 12.5 @20°C Operating temperature °F -40~+95 Weight lb 3.3 PTC heating element Flexible signal control (on/off control) LED for fan & heater status Triple protection(mechanical temp. switch , NTC sensor & fuse ) Compact design

Foot Mount Heater Item HEH095BA Outline dimension inch 6.6H x 5.7W x 2.3D Heating capacity W 950 @20°C Rated voltage VDC 220 (Typ.) Rated current A 4.5 @20°C Operating temperature °F -40~+95 Weight lb 3.3 Cartridge heating element Compact design Triple protection(mechanical temp. switch , NTC sensor & fuse )

Rack Mount Heater Item HEH100PB Outline dimension inch 1.7H X 19.0W x 7.0D Heating capacity W 1000 @ 68 oF Rated voltage VDC 48 VDC Rated current A 22 @ 68 oF Operating temperature °F -40~+95 Weight lb 5.0 PTC heating element Compact design (1U) Triple protection(mechanical temp. switch , NTC sensor & fuse )

1U Rack Mount Heater-2 1U design 1U 1U Package Easy install to rack Model Name: HEH100PB Heating Capacity:1000W Rated Voltage: DC 48V Rated Current: 22A IP Protection: IP 20 Weight (Kg): 2.5 Dimensions (inch):1.7H X 19.0W x 7.0D

Block Test for Plastic case Normal Run test Block Test Simulate situation 1.FAN failed 2.FAN inlet blocked 3.FAN outlet blocked Test result: Highest PTC’s temperature is lower than plastic deform point (Heater ON/ Fan ON) (Heater ON / Fan OFF) 129 ℃ 208. ℃ 120 ℃ 211 ℃ 87 ℃ 200 ℃ 94 ℃ 212 ℃ < Plastic Case Resistance of 223℃

Better Performance in Low Ambience DC48V input 700W Heating power At 0 oC Dry contact close DC48V input 400W Heating power At 20 oC Dry contact open

Smarter. Greener. Together. To learn more about Delta, please visit www.deltaww.com or scan the QR code English Traditional Chinese Simplified Chinese