Gas Chromatography Vaporization of sample Gas-solid

Slides:



Advertisements
Similar presentations
Basic Principles of Gas Chromatography
Advertisements

Gas Chromatography.
Gas Chromatography Introduction 1.) Gas Chromatography
GAS CHROMATOGRAPHY CHAPTER 21.
Gas Chromatography Lecture 36.
Gas Chromatography 427 PHC.
Lecture 8b Gas Chromatography.
Gas Chromatography.
GAS CHROMATOGRAPHY ENVE 202 Dr. Aslıhan Kerç.
GAS CHROMATOGRAPHY.
Lab Methods Day June 25, 2014 Gas Chromatography
Mobile phase is a gas! Stationary phase could be anything but a gas
Gas Chromatography A.) Introduction: B.) Equipment:
Gas Chromatography in the detection of Volatile Organic Compounds.
Flame Ionization Detector Most common detector Carbon atoms (C-C bonds) are burned in a hydrogen flame. A small portion of carbon atoms are ionized (about.
Experiment 6 Simple and Fractional Distillation.
1 Gas Chromatography Lecture a. Thermal Conductivity Detector (TCD) This is a nondestructive detector which is used for the separation and collection.
Gas Chromatography.
Chapter 27 Gas Chromatography
1 Chapter 24 GC Gas Chromatography. 2 GC Mechanism of separation is primarily volatility. Difference in boiling point, vapor pressure etc. What controls.
Gas chromatography is used in many research labs, industrial labs (quality control), forensic (arson and drug analysis, toxicology, etc.), environmental.
Gas Chromatography.
Chromatography Chapter 4.
GC Detectors Ideal Detector Characteristics: 1. Universal Response
Gas Liquid Chromatography
Gas Chromatography. Gas Chromatography Basics Gas Liquid Chromatography (GLC) Gas Solid Chromatography (GSC) Mobile phase does not interact with analyte.
Chapter 22 GC & LC Gas Chromatography -1 1.Schematic diagram.
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
GAS – LIQUID CHROMATOGRAPHY BY M. GLORY HEPSIBAH M.PHARM (PH. ANALYSIS) BHARAT COLLEGE OF PHARMACY.
Gas Chromatography A.) Introduction: B.) Equipment:
Chapter 27 Gas Chromatography 1. Principles
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
In gas-liquid chromatography (g.l.c.) a long tube contains the chromatography material. The tube is usually coiled so that it takes up less space.
CHROMATOGRAPHY. The general name given to methods by which two or more compounds in a mixture are physically separated by distributing themselves between.
Gas Chromatography A separation science.... What is Chromatography? The separation of a mixture of two or more compounds or ions by distribution between.
animation.php.
INSTRUMENTAL ANALYSIS CHEM 4811 CHAPTER 12 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
GAS LIQUID CHROMATOGRAPHY
Gas Chromatography A separation science.... What is Chromatography? The separation of a mixture of two or more compounds or ions by distribution between.
FID Gas Meter/Detector. Introduction Air monitoring data is useful for: *Assessing the health risks to the public and response workers. *Selecting personal.
 This method of separation is called gel, molecular sieve or size-exclusion mechanism of separation.  Size exclusion.
Gas Chromatography: Detectors. The Ideal Detector n Adequate sensitivity - range 10 ^- 18 to 10^-15 g analyte/s n good stability and reproducibility n.
Gas Chromatography Lecture 38.
Intensive General Chemistry Chemical separations II Isabelle Vu Trieu
Analytical Separations
Basic Gas Chromatography. History Separation of dyes by Runge Separation of plant pigments by Tswett Theoretical gc (Martin & Synge)
Created with MindGenius Business 2005® Gas Chromatography Gas Chromatography From Harris, Quantitative Chemical Analysis, 6e, Chapter 24.
GAS CHROMATOGRAPHY In gas chromatography (GC), the sample is injected onto the head of a chromatographic column and immediately vaporized. The components.
GAS LIQUID CHROMATOGRAPHY Principles Partition of molecules between gas (mobile phase) and liquid (stationary phase).
Ch 21 – Principles of Chromatography and Mass Spectrometry Ch 22 – Gas and Liquid Chromatography.
Chapter 32 Gas Chromatography. In gas chromatography, the components of a vaporized sample are separated by being distributed between a mobile gaseous.
Dr. Ashraf M. M. Mahmoud, Associate professor
Gas Chromatography. In Gas Chromatography (GC), a gaseous mobile phase transports a gaseous solute through a long, thin column containing solid or liquid.
K V GOPINATH M Pharm PhD,CPhT Tirumala Tirupati Devasthanams TIRUPATI GAS CHROMATOGRAPHY.
Gas Chromatography Oleh : Rohayati, S.Pd SMK Negeri 13 Bandung.
Gas Chromatography.
M.PRASAD NAIDU Msc Medical Biochemistry, Ph.D Research scholar.
Experiments in Analytical Chemistry
Gas Chromatography Chap 27 Types: Gas-solid chromatography (GSC)
Reading assignment: section 26E(p781) Chapter 26 # 2, 3, 14, 15, 16 Chapter 27 # 7(a,d,f), 22, 23, 24, 25.
GAS CHROMATOGRAPH. GAS CHROMATOGRAPH Principle: Which type of compounds can analyse? Volatile Thermostable.
An analytical instrumentation process
Chapter 27 Gas Chromatography
Pure Carrier Gas Grades (subjective)
VAPOUR PHASE CHROMATOGRAPHY
Chromatography Daheeya Alenazi.
Gas Chromatography.
32A-4 Chromatographic Detectors
GAS CHROMATOGRAPHY.
Presentation transcript:

Gas Chromatography Vaporization of sample Gas-solid Physical absorption Gas-liquid Liquid immobilized on inert solid Principles Instrumentation Applications

Retention Volumes Volumes rather than times Accounts for temperature and pressure effects (non linear) High pressure at inlet VR=tRF VM=tMF F=average flow rate Can be measured t=time R=retained species M=mobile species Correction term j for pressure drop

Retention Volumes Correct volumes Specific retention volume MS = mass of stationary phase, T in K Vg useful for species identification term scales with vapor pressure

Instrumentation Carrier gas He (common), N2, H2 F=25-150 mL/min packed column F=1-25 mL/min open tubular column Column 2-50 m coiled stainless steel/glass/Teflon Oven: 0-400 °C ~ average boiling point of sample Detectors FID, TCD, ECD, (MS)

Flame Ionization Detector Rugged Sensitive (10-13 g/s) Wide dynamic range (107) Signal depends on C atoms in organic analyte mass sensitive, not concentration sensitive •Weakly sensitive carbonyl, amine, alcohol, amine groups • Not sensitive H2O, CO2, SO2, NOx Destructive technique

Thermal Conductivity Detector Change in gas thermal conductivity Difference between carrier gas and analyte Thermal conductivity of He, H2 much larger than organics Organics cause T rise in filament Rugged Wide dynamic range (105) Nondestructive

Electron Capture Detector Electrons from radioactive source Organic molecules capture electrons and decrease current Simple and reliable Sensitive to electronegative groups halogens, peroxides Insensitive to amines, alcohols Largely non-destructive Limited dynamic range (102)

Columns Packed liquid coated silica particles (<100-300 mm diameter) in glass tube best for large scale but slow and inefficient Capillary/Open Tubular wall-coated (WCOT) <1 mm thick liquid coating on inside of silica tube support-coated (SCOT) 30 mm thick coating of liquid coated support on inside of silica tube best for speed and efficiency but only small samples

High Performance Liquid Chromatography Mobile phase is liquid Four types partition adsorption (liquid-solid) ion exchange size exclusion or gel

Instrumentation For reasonable analysis times, moderate flow rate required but small particles (1-10 mm) Solvent forced through column 1000-5000 psi - more elaborate instrument than GC Solvents degassed - "sparging“ High purity solvents Single mobile phase composition isocratic elution Programmed mobile phase composition gradient elution Sample introduced without depressurization

Instrumentation HPLC Columns: Stainless steel 10-30 cm long 4-10 mm internal diameter 1-10 mm particle size - 40,000-60,000 plates/m High Speed Isocratic Separation 100,000 plates/m Variation in solvent changes elution polarity

Partition Chromatography Most popular method Low molecular weight (mw<3000) analytes Polar or non-polar Bonded stationary phase column liquid chemically bonded to support particles 3, 5 or 10 mm hydrolyzed silica particles coated with siloxanes Normal phase HPLC nonpolar solvent/polar column Reversed phase HPLC polar solvent/nonpolar column

Gel Permeation Size Exclusion Used for large mw compounds proteins and polymers Separation mechanism is sieving not partitioning Stationary phase porous silica or polymer particles polystyrene, polyacrylamide) (5-10 mm) well-defined pore sizes (40-2500 Å) Large molecules excluded from pores not retained, first eluted (exclusion limit - terms of mw) Intermediate molecules retained, intermediate elution times Small molecules permeate into pores strongly retained, last eluted (permeation limit - terms of mw)