Surface Plasmon Resonance Imaging for Biosensor Applications Presented by Michelle Brideau March 31, 2005 CHEM 395.

Slides:



Advertisements
Similar presentations
Tunable Surface Assembly of Gold Nanorods for Biosensor Applications
Advertisements

Label Free Biomolecular Detection using Ellipsometric principles: Two Methods Jeremy Colson.
The Wave Nature of Light Thin Film Interference
Conclusions Future work Methods Background Introduction Lily Stanley, Juan Du, and Xuan Gao Department of Physics, Case Western Reserve University Nanowire.
Process Measurements Division Surface Immobilization of Biopolymers Patent #5,942,397 Issued Aug. 24, 1999 Inventors: Michael J. Tarlov, Tonya M. Herne,
D. Yu1, S.-Y. Kim1, Y. Cho2, J. Y. Lee2, H. J. Kim2, and J. W. Kim2
Surface Plasmon Resonance Biosensors
Gold Nanorod Biosensors and Single Particle Spectroscopy Jason H. Hafner MURI site visit July 27, 2005.
Molecular Biomimetics Polypeptides to Inorganic structures.
Optical sources Lecture 5.
Bragg’s Law nl=2dsinΘ Just needs some satisfaction!! d Θ l
Lecture 11. Microscopy. Optical or light microscopy involves passing visible light transmitted through or reflected from the sample through a single or.
Spectroscopic Ellipsometry University of Texas at El Paso Lynn Santiago Dr. Elizabeth Gardner Chem 5369.
AP Physics Mr. Jean March 30 th, The plan: Review of slit patterns & interference of light particles. Quest Assignment #2 Polarizer More interference.
Ohki Labo. Research Activities. Polymer Gr. (Polymer material) 1. Polymer Gr. (Polymer material) Environment problems, Global heating, Biodegradability,
Physics for Scientists and Engineers, 6e
Surface Plasmon Spectroscopy Lokanathan Arcot Department of Forest Products Technology School of Chemical Technology Aalto University.
LOGO The development of SPR biosensor Xixian Ye
1 Localized surface plasmon resonance of optically coupled metal particles Takumi Sannomiya*, Christian Hafner**, Janos Vörös* * Laboratory of Biosensors.
Surface Enhanced Infrared Absorption (SEIRA) Spectroscopy
Phy 212: General Physics II Chapter 35: Interference Lecture Notes.
Surface Plasmon Resonance: antigen-antibody interactions Vamsi K. Mudhivarthi.
Surface Plasmon Resonance for Immunoassays
c = km/sec I F = I 0 x (cosθ) 2.
POSTER TEMPLATE BY: Developing Novel Supported Membrane Interfaces for SPR Study of Transmembrane Proteins Heather Ferguson*,
Newton’s Rings Another method for observing interference in light waves is to place a planoconvex lens on top of a flat glass surface, as in Figure 24.8a.
Interference Applications Physics 202 Professor Lee Carkner Lecture 25.
Applications of SPCE to Pharmaceutical Research Kathleen Hamilton, Tom Laue, and James Harper Presentation at the 2007 BITC Meeting University of New Hampshire.
ARC 11/02/10 Recent Advances in Surface Plasmon Resonance: From Biosensor to Space/astronomical Interest Hololab and CSL S. Habraken, C. Lenaerts, and.
1 Optical Properties of Materials … reflection … refraction (Snell’s law) … index of refraction Index of refraction Absorption.
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Surface Enhanced Raman Spectroscopy (SERS) Jeanne Bonner PHYS 275 November 26, 2007.
Common types of spectroscopy
The Hong Kong Polytechnic University Optics II----by Dr.H.Huang, Department of Applied Physics1 Light Waves Nature of Light: Light can be viewed as both.
TIRF Total Internal Reflection Fluorescence Microscopy specialized fluorescence microscopy technique specifically images a very thin optical section (50-250nm)
Total Internal reflection Fluorescence Microscopy: Instrumentation and Applications in Cell biology.

Microarray Technology
Biometric Sensing: Plasmonic Theory and Label-free Applications
Microarray - Leukemia vs. normal GeneChip System.
FEMTOSECOND LASER FABRICATION OF MICRO/NANO-STRUCTURES FOR CHEMICAL SENSING AND DETECTION Student: Yukun Han MAE Department Faculty Advisors: Dr. Hai-Lung.
1 Investigation of Optical Properties n, k … index of refraction and damping  1,  2 … polarization and absorption Problems: The penetration depth of.
Diffraction is the bending of waves around obstacles or the edges of an opening. Huygen’s Principle - Every point on a wave front acts as a source of tiny.
Surface Plasmon Resonance (SPR)
Chapter 16 Pretest Interference and Diffraction. 1. When monochromatic light is reflected from a thin transparent film, A) constructive interference occurs.
Interference Applications Physics 202 Professor Lee Carkner Lecture 25.
PRESENT BY- RUCHI DIXIT KAMAKSHI KHATRI. INTRODUCTION During the last two decades we have witnessed remarkable research and development activity aimed.
Ch 16 Interference. Diffraction is the bending of waves around obstacles or the edges of an opening. Huygen’s Principle - Every point on a wave front.
Spectrophotometry.
Surface Plasmon Resonance
Computational Biology and Bioinformatics Lab. Songhwan Hwang Functional Genomics DNA Microarray Technology.
IB Physics 11 Mr. Jean January 22 nd, The plan: Video clip of the day Polarization.
Physics 11 Advanced Mr. Jean May 28 th, The plan: Video clip of the day Wave Interference patterns Index of refraction Slit & Double Slit interference.
Conditions for Interference
BOC tutorial 12/10/2015. Wood, R W Philosophical Magazine 4: 269–275. angle grating silver Wavelength (Å) Angle of Incidence.
Refraction The bending of light due to a change in speed.
1.1 What’s electromagnetic radiation
Date of download: 5/27/2016 Copyright © 2016 SPIE. All rights reserved. (a) Detail of the chip reflectance spectra measured by TM polarized light at 5.
Date of download: 6/3/2016 Copyright © 2016 SPIE. All rights reserved. Lens L focuses 488 or 514nm of light from an argon-ion laser at the BFP of a 1.45.
Light and Optics  The Electromagnetic Spectrum  Interference, Diffraction, and Polarization Wave Properties of Light.
 FT-IR stands for Fourier Transform Infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR radiation is passed through.
Neethu Xavier St. Alberts College Cochin, India Microcantilever Biosensors: Making Sensors Reliable.
A Sandwich DNA Model for Rapid and Sensitive Detection of NSCLC Utilizing the Magnetic Modulation Biosensing System Saar Ashri The Open University Optical.
D. Yu1, S.-Y. Kim1, Y. Cho2, J. Y. Lee2, H. J. Kim2, and J. W. Kim2
BAHIRDAR UNIVERSTY COLLEGE OF SCIENCE DEPARTMENT :MATERIAL SCIENCE AND ENGINNERING PRESENTETON ON: ELLIPSOMETRY INSTRUMENT PREPEARED BY :ZELALEM GETU AMSALE.
Hybrid plasmonic multichannel spectroscopic sensor platform
Interference Introduction to Optics Coherent source
Direct Observation of Single MuB Polymers
Volume 99, Issue 12, Pages (December 2010)
PLASMONICS AND ITS APPLICATIONS BY RENJITH MATHEW ROY. From classical fountations to its modern applications
Presentation transcript:

Surface Plasmon Resonance Imaging for Biosensor Applications Presented by Michelle Brideau March 31, 2005 CHEM 395

Outline 1.Surface Plasmon Resonance SPR background SPR imaging 2.SPR imaging experiments 3.Conclusions Advantages of SPR Future applications

Surface Plasmon Resonance (SPR) Label-free method Surface sensitive spectroscopic technique Used to detect the binding of biological molecules onto arrays of probe biomolecules covalently attached to chemically-modified gold surfaces

Typical Signal from SPR Measurement

How does SPR work? This Kretschmann Experimental System uses a metal film thin enough to monitor the plasmon A plasmon can be thought of as a ray of light bound onto a surface - propagating among the surface and presenting itself as an electromagnetic field.

Otto Experimental System (1968) Impossible to observe plasmon through infinite metal The Kretschmann system (1971) is used in designs of SPR instruments

Metals Gold and silver are most commonly used. Aluminum and copper may also be suitable metals.

SPR A surface-plasmon-resonance is excited at a metal-dielectric interface by a monochromatic, p- polarized light beam, such as He-Ne laser beam The surface plasmon is sensitive to changes in the environment near the interface and therefore has potential as a sensing probe. Sensitive detection method that monitors variations in thickness and refractive index in ultra-thin films-

Refractive Index Ratio of velocity of propagation of electromagnetic wave in vacuum to velocity in medium

More about SPR It is a non-destructive means of sensing Surface Plasmons have already been used for gas sensing, biosensing, immuno-sensing and electrochemical studies.

Modifications for SPR imaging apparatus The p-polarized He-Ne laser beam passes through a spatial filter and can be expanded using a beam expander The reflected light is collected by a CCD camera to produce an SPR image

SPR imaging apparatus Spatially-filtered, expanded, p-polarized HeNe laser beam illuminates the gold sample through a prism coupler. Reflected light from the gold surface, containing the SPR image, is monitored with a CCD camera. The angle of incidence can be changed by rotating the entire sample assembly. A.J. Thiel et. al., Anal. Chem. 69 (1997), pp. 4948–4956.

SPR Imaging Experiment Investigation of adsorption processes of oligonucleotides onto gold substrates in aqueous buffer solution Monitored hybridization process of thiol-modified single stranded oligonucleotide anchored to gold surface with its complementary sequence Traditional analysis of hybridization involves labeling, such as radioactive isotopes or fluorescent molecules

Preparation Glass slides (cleaned in piranha solution) 2nm chromium layer (adhesion layer) followed by 50nm gold film Gold surface spotted with HS-ssDNA (thiolated oligonucleotide probes) and left to react for at least 18h After soaked and rinsed in water, the probes were ready for hybridization Probes were immersed in hybridization buffer containing complementary oligonucleotide in Phosphate buffer system at pH 7.4

Hybridized helices formed on gold substrate R. Rella, et al. Biosensors and Bioelectronics. 20 (2004), pp Thiol-modified, single stranded oligonucleotide anchored to gold surface Immersed in mercaptoethanol for 18h to eliminate aspecific adsorption sites on the gold surface Forms dsDNA with complementary sequence

SPR Reflectivity The cusp does not change in the presence of the oligo, therefore ensures reproducibility of the scanning measurement 0.41 degree shift of the self assembled monolayer from the bare gold surface was used to estimate a 5nm thickness of self assembled oligonucleotide and refractive index of 1.65 R. Rella, et al. Biosensors and Bioelectronics. 20 (2004), pp

2D and 3D Images of ssDNA Shows the 5 spots of self assembled thio- oligonucleotide DNA probes immobilized on the gold surface Color variation indicates variation in the thickness of the self assembled monolayer (SAM) R. Rella, et al. Biosensors and Bioelectronics. 20 (2004), pp

3D Images of ssDNA (top) and dsDNA (bottom) SPR images of immobilization (ssDNA) and hybridization (dsDNA) in liquid. Hybridization process shown by variation in resonance signal of a specific self assembled spot. R. Rella, et al. Biosensors and Bioelectronics. 20 (2004), pp

2D Images of ssDNA (top) and dsDNA (bottom) The increase in resonance signal corresponds to the increase in layer thickness indicative of the hybridization process R. Rella, et al. Biosensors and Bioelectronics. 20 (2004), pp

Summary SPR imaging used to obtain images of thio-oligonucleotides linked onto a gold surface Detection of DNA hybridization using liquid phase SPR imaging techniques

Advantages of SPR imaging Identification of binding events with label-free molecules High speed and sensitivity with real-time reaction monitoring High spatial resolutions Identity specific vs. non-specific adsorption processes In-situ capabilities

Future Applications Using the technique to obtain the total number of target DNA hybridization events per unit area Construct patterned gold substrates and self assemble DNA probes of different nature Construct a DNA array suitable to detect specific DNA sequence target

Thank You

References: R. Rella, J. Spadavecchia, M.G. Manera, P. Siciliano, A. Santino, G.Mita. Liquid Phase SPR imaging experiments for biosensors applications, Biosensors and Bioelectronics. 20 (2004), pp A.J. Thiel, A.G. Frutos, C.E. Jordan, R.M. Corn and L.M. Smith, In situ surface plasmon resonance imaging detection of DNA hybridization to oligonucleotide arrays on gold surfaces, Anal. Chem. 69 (1997), pp. 4948–

NOTES

SIGNAL DETECTION The light source for SPR is a high efficiency near- infrared light emitting diode which has a fixed range of incident angles. The SPR response is monitored by a fixed array of light sensitive diodes covering the whole wedge of reflected light. The angle at which minimum reflection occurs is detected and converted to the resonance units. The SPR angle depends on several factors, most notably the refractive index into which the evanescent wave propagates on the non-illuminated side of the surface. In addition the other parameters are the wavelength of the incident light and the properties of the metal film.

As we change the angle of incidence of light (at a fixed frequency), at some angle the projection of the light wave vector onto the metal film becomes equal to the wave vector of SP's at the same frequency. Light energy can then be effectively transferred to the SP's. If we vary the thickness of the metal film, the phase difference between the reflected light and the light re-radiated by SP's will change. If we scan the angle of incidence of light onto a metal film of the right thickness, then at a certain angle the reflected light intensity will go sharply to almost zero, indicating resonant coupling to surface plasmons. This angle is always greater than the angle of total internal reflection off the prism/outer dielectric interface, and is called the attenuated total reflection (ATR) angle. And this angle is important, because the position and the width of this resonance point are very sensitive to the properties of the surface and the media next to it. It makes it possible to use surface plasmon resonance techniques for chemical and biological sensing. How it works

SPR imaging SPR imaging is a surface sensitive optical technique for monitoring the adsorption of solution species into patterned molecular microarrays that have been made on chemically modified metal surfaces (gold). SPR can be used to study the specific adsorption of biopolymers (oligonucleotides, proteins, antibodies) onto DNA or protein microarrays. The microarray format makes the SPR technique a high throughput differential binding measurement system that can be used to accurately measure the specific organic and biomolecular interactions with a variety of surfaces under identical solution adsorption conditions. Various biomolecular interactions can be characterized including DNA-DNA, RNA- DNA, protein-DNA and protein-protein binding. As a surface-sensitive measurement, SPR is an indispensable tool for the study of in-situ biological systems of weakly bound interactions. Since the SPR imaging experiment senses the change in the local index of refraction upon adsorption onto the metal surface, no labeling of the biomolecules is required. The combined simplicity and versatility of surface plasmon resonance imaging measurements make them ideally suited to the study of ultra thin organic films. The technique is extremely sensitive, provides reasonable lateral resolution and can be used in both ex-situ and in-situ configurations to monitor the real-time binding of label free analyte molecules to metal surfaces. The two dimensional analysis of imaging data, combined with our microarray manufacturing and processing technologies on gold surfaces makes surface plasmon resonance a powerful tool for the parallel processing of multiplexed biomolecular interactions.

Specifications of the SPR Imager Sensitive to less than 1 angstrom molecular thickness range Liquid cell attachment for in-situ measurements High precision coupled prism and detector rotating stage Spectral range from 600nm to 1100nm Incident angle range for 40 to 70 degrees for differing prism and sampling systems High sensitivity near IR CCD detector with video interface Image acquisition interface and image processing software 110 or 220 volt versions