Long Lifetime CW H- Ion Source for Project X

Slides:



Advertisements
Similar presentations
FIGURE 7.1 Elements of the final control operation.
Advertisements

The 26g Al(p, ) 27 Si Reaction at DRAGON Heather Crawford Simon Fraser University TRIUMF Student Symposium July 27, 2005.
Matter waves 1 Show that the wavelength of an electron can be expressed as where E is the energy in volts and  in nm.
1 White-paper review Axial Flux Technology for Motors & Generators.
Chapter 7 Ionic and Metallic Bonding 7.2 Ionic Bonds and
Triple-GEM detector operation for high-rate particle triggering W. Bonivento, G. Bencivenni, A. Cardini, C. Deplano, P. de Simone, F. Murtas, D. Pinci,
FEM FOR HEAT TRANSFER PROBLEMS
Copyright © 2011, Elsevier Inc. All rights reserved. Chapter 6 Author: Julia Richards and R. Scott Hawley.
Balanced Device Characterization. Page 2 Outline Characteristics of Differential Topologies Measurement Alternatives Unbalanced and Balanced Performance.
HKCEE Chemistry Volumetric Analysis &
FOM-Institute for Plasma Physics Rijnhuizen Association Euratom-FOM T E CT E C T E CT E C Carbon Chemical Erosion Yield Experiments in Pilot-PSI Jeroen.
FIGURE 6.1 The electromagnetic radiation spectrum covers everything from very low frequency (VLF) radio to X-rays and beyond. Curtis Johnson Process.
FIGURE 5.1 Potentiometric displacement sensor.
Ion Heating and Velocity Fluctuation Measurements in MST Sanjay Gangadhara, Darren Craig, David Ennis, Gennady Fiskel and the MST team University of Wisconsin-Madison.
Towards a neutron target and Measuring (n, ɣ) cross sections of the r-process Lothar Buchmann TRIUMF.
An Image Filtering Technique for SPIDER Visible Tomography N. Fonnesu M. Agostini, M. Brombin, R.Pasqualotto, G.Serianni 3rd PhD Event- York- 24th-26th.
1. Name the particles in the atom and give the charges associated with each.
Objectives By the end of this section you should:
Multi Beamlett Extraction Experiments and Sector Magnet Field Investigation.
Plasma Window Options and Opportunities for Inertial Fusion Applications Leslie Bromberg Ady Herskovitch* MIT Plasma Science and Fusion Center ARIES meeting.
RFQ development for high power beams
Control and Feedback Introduction Open-loop and Closed-loop Systems
S. N. HOM Impedance in Vacuum … 1 of 40 Sasha Novokhatski SLAC, Stanford University Machine-Detector Interface Joint Session April 22, 2005 HOM Impedance.
Basics on COD measurement
Center for Radiative Shock Hydrodynamics Fall 2011 Review Experimental data from CRASH experiments Carolyn Kuranz.
LINAC 4 Emittance Meter.
Chiu Choi, Ph.D., P.E. Technical Consultant OIML workshop on the metrology of vehicle speed measurement devices NIST Headquarters, Gaithersburg, MD July.
1. 2 Earthquake effects on health care facilities 2.
Imperial College London 1 3. Beam extraction 3. Extraction of particle beams 3.1 The space charge limit and Child-Langmuirs law 3.2 External and internal.
An introduction to Ultraviolet/Visible Absorption Spectroscopy
Communication Systems (EC-326)
1..
1 LOA-ENSTA. 2 3 For PW class laser, a contrast better than is required I ASE has to be < W/cm² The ASE intensity is enough to generate.
H – Ion Source Development at RAL & FNAL PASI Meeting, RAL 3 rd April 2013 Scott Lawrie & Dan Faircloth (RAL) Dan Bollinger (FNAL)
SNS Spallation Neutrino Source 1 SNS layout GeV proton linear accelerator Accumulator ring Main target Stripping foil.
Fisica Generale - Alan Giambattista, Betty McCarty Richardson Copyright © 2008 – The McGraw-Hill Companies s.r.l. 1 Chapter 17: Electric Potential Electric.
1 Chapter 13 Nuclear Magnetic Resonance Spectroscopy.
THE CHEMICAL CONCEPT INVENTORY
Overview of ERL R&D Towards Coherent X-ray Source, March 6, 2012 CLASSE Cornell University CHESS & ERL 1 Cornell Laboratory for Accelerator-based ScienceS.
16. Magnetic brakes ”When a strong magnet falls down a non ferromagnetic metal tube, it will experience a retarding force. Investigate the phenomenon.”
A proposal for a polarized 3 He ++ ion source with the EBIS ionizer for RHIC. A.Zelenski, J,Alessi, E.Beebe, A.Pikin BNL M.Farkhondeh, W.Franklin, A. Kocoloski,
Chapter 11 Nuclear Chemistry. 11 | 2 Nuclear Chemistry cont’d What is nuclear chemistry? The study of reactions that result from changes in the nucleus.
Figure An amplifier transfer characteristic that is linear except for output saturation.
Intense Diagnostic Neutral Beam For Burning Plasmas Challenges for ITER and Opportunities for KSTAR Jaeyoung Park Glen Wurden and MFE team Los Alamos National.
Ion Injector Design Andrew Seltzman.
Neutral Particles. Neutrons Neutrons are like neutral protons. –Mass is 1% larger –Interacts strongly Neutral charge complicates detection Neutron lifetime.
Neutron Generation and Detection Lee Robertson Instrument & Source Division Oak Ridge National Laboratory 17 th National School on Neutron and X-ray Scattering.
HYBRIS: R. Keller Page 1 A Hybrid Ion Source Concept for a Proton Driver Front-End R. Keller, P. Luft, M. Regis, J. Wallig M. Monroy, A. Ratti, and.
Inertial Electrostatic Confinement Fusion Reactor Liquid Cooled Ion Accelerating Grid Design A. Seltzman, Georgia Institute of Technology Abstract: Reactor.
Initial wave-field measurements in the Material Diagnostic Facility (MDF) Introduction : The Plasma Research Laboratory at the Australian National University.
Measurement and modeling of hydrogenic retention in molybdenum with the DIONISOS experiment G.M. Wright University of Wisconsin-Madison, FOM – Institute.
Ursel Fantz for the IPP-NNBI Team 16 th ICIS, New York City, USAAugust 23-28, 2015 Towards 20 A Negative Hydrogen Ion Beams for Up to 1 hour: Achievements.
Industrial Applications of ECR-Based Neutron Generators
Radioactive ion beam facilities How does they work ? 2012 Student Practice in JINR Fields of Research 9.oct.2012 I. Sivacekflerovlab.jinr.ru.
Negative Ions in IEC Devices David R. Boris 2009 US-Japan IEC Workshop 12 th October, 2009 This work performed at The University of Wisconsin Fusion Technology.
Hiden Analytical Excellence in plasma diagnostics An Introduction to the Hiden EQP Excellence in Plasma Diagnostics An Introduction to the Hiden EQP
LRT2004 Sudbury, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay NOSTOS.
VNIIA neutron generators for thermonuclear research
Tunable, resonant heterodyne interferometer for neutral hydrogen measurements in tokamak plasmas * J.J. Moschella, R.C. Hazelton, M.D. Keitz, and C.C.
24 January 2001J. Lettry1 ISOLDE Introduction –PSB-beam, Targets –Ion-sources Facility performance –Front-ends and robots –Target production –Safety.
Pellet Charge Exchange Measurement in LHD & ITER ITPA Tohoku Univ. Tetsuo Ozaki, P.Goncharov, E.Veschev 1), N.Tamura, K.Sato, D.Kalinina and.
X-ray absorption spectroscopy (XAS)
The Heavy Ion Fusion Virtual National Laboratory Neutralized Transport Experiment (NTX) P. K. Roy, S. S. Yu, S. Eylon, E. Henestroza, A. Anders, F. M.
RF source, volume and caesiated extraction simulations (e-dump)
Andrew Seltzman. Georgia Institute of Technology, Dept. of Physics
Study on Monatomic Fraction Improvement with Alumina Layer on Metal Electrode in Hydrogen Plasma Source Bong-Ki Jung, Kyung-Jae Chung, Jeong-Jeung Dang,
Seok-geun Lee, Young-hwa An, Y.S. Hwang
Outside the nucleus, the beta decay {image} will not occur because the neutron and electron have more total mass than the proton. This process can occur.
Physics Design on Injector I
(Beam) Commissioning Plan
Presentation transcript:

Long Lifetime CW H- Ion Source for Project X Evan Sengbusch, PhD Joe Sherman, PhD Preston Barrows Daniel Swanson Fermi National Laboratory July 11, 2013

Project X Requirements and Proposed Solution Microwave Ion Source + Cesium Converter > 10 mA CW H- beam current Beam emittance < 0.2 pi- mm-mrad at RFQ entrance Extracted at 30 kV Lifetime > 1 month (4-6 months preferred) High gas efficiency Hi power efficiency Magnetic Filter Plasma Chamber Cesium Converter Beam Extraction -30 kV Ground Ground Waveguide Break Faraday Cup/ Diagnostics Autotuner Waveguide Magnetron Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Phoenix Nuclear Labs Founded in 2005; 14,000 ft2 lab (including two shielded bunkers) located in Madison, WI Multidisciplinary team of PhD scientists, engineers (nuclear, electrical, mechanical), and technicians PNL core mission is to design, build, and commercialize high flux neutron generators PNL has demonstrated neutron production of 3x1011 n/s (D-D) CW and anticipates a 5x1011 n/s demonstration in 6-12 months Funded primarily by VC’s/angels and several DoD / DoE contracts: $50M NNSA cooperative agreement - isotope production 4 DoD Contracts – Neutron radiography, IED detection, nuclear survivability, and neutron diffraction DoE – Ion source development for high energy physics JIEDDO – Pending contract to study stand-off detection of IED’s Confidentiality statement: This document is the joint property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as jointly authorized by PNL.

PNL High-Flux Neutron Generator Technology base: 300 kV deuterium beam incident on deuterium or tritium gas target Up to 5x1011 DD n/s or 5x1013 DT n/s emitted isotropically Key innovations: Gaseous target increases neutron yield and device lifetime Very high current achieved by novel ion source and beam extraction design 2 prototypes have been built and are operating P-I: Radiography system (US Army) P-II: Medical isotope production (Nat Nuclear Security Admin) 2 in design phase P-III: IED detection (US Army) P-IV: Medical isotope production (Nat Nuclear Security Admin) Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

PNL Neutron Generator Methodology P-II Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

PNL Microwave Source Performance 122 hour (99.99% uptime) CW operation demonstrated at 50 mA, 45 kV > 90 mA deuterium extracted at 260 kV 60kV, 65mA Beam on calorimeter PNL Ion Source Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Medical Isotope Production PNL is a subcontractor on a $50M+ cooperative agreement with the National Nuclear Security Administration (NNSA) and SHINE Medical Technologies for domestic production of the medical isotope Moly-99 Moly-99 is used by 55,000 patients each day in the US for nuclear medicine procedures US Gov has made a non-HEU domestic source of Moly-99 a high priority Eight subcritical fission assemblies, utilizing an aqueous solution of LEU, will each be driven by the PNL intense neutron generator to produce half of the total global demand for Moly-99 Starting in 2016, 8 neutron sources per year (5x1013 DT n/s each) will be delivered to the SHINE isotope production facility and will be maintained and serviced by PNL Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Neutron Radiography Orders-of-magnitude increase in neutron yield allows for practical implementation of non-reactor thermal neutron radiography for: Artillery shells – system delivered to US Army Critical aircraft and spacecraft components Composite materials Fast neutron radiography is of interest for cargo screening at sea- and airports Requires high neutron yield to be practical Provides elemental information complementary to X-rays Dual X-ray/Neutron radiography systems being implemented in China, Australia (CSIRO/NuTech) Rapiscan recently requested information about the PNL neutron source for fast neutron radiography Neutrons X-Rays Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Component Testing & Evaluation Army Phase I SBIR has been awarded to PNL to evaluate using PNL neutron generator to irradiate critical components Air and spacecraft operate in high-radiation environments and must be tested and hardened Current testing done at HEU-based reactors – high cost and security/regulatory burden PNL’s neutron source can simulate nuclear environments without HEU Air Force Phase I SBIR has been awarded to PNL to evaluate aircraft components using neutron diffraction Neutron diffraction is a proven technique for bulk residual stress analysis Presently only available at reactors and spallation sources PNL’s high neutron yield could allow this important measurement technique to take place in laboratory/factory settings Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Neutron-Based IED/SNM Detection Neutrons interact with explosive elemental constituents or fissile material High energy gamma rays and/or neutrons are emitted and detected to signal the presence an IED or SNM With very intense sources, detection is possible at operationally significant standoff distances; elemental composition information available also PNL is being funded by the Army and JIEDDO to miniaturize its neutron generator for mobile and/or vehicle-mounted detection Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Ion Source Overview Technical - historical account of Stevens Institute (Hoboken, NJ), and their analysis of H- production by hyperthermal H0 on cesiated molybdenum surface (1993). Review of LEDA (LANL) H+ injector performance (1993-2002) based on the microwave proton source (MWS), and why this source appears to be an excellent cw H0 driver for cesiated converter source. Simulation for 10mA, 30keV H- beam extraction. Meets Project X requirements. Practical realization of long lived H- source. Uses experience from the Chalk River Lab and the Los Alamos LEDA MWS technology. This H- source is based on the U.S. Spallation Neutron Source (SNS) Cs converter, the Lawrence Berkeley National Lab (LBNL) magnetic filter, and the Cs H- converter technology from Novosibirsk. Third talk is on H- source design details. (Preston Barrows) Confirmation of MWS plasma properties optimal for Cs converter H- production High electron temperature (kTe) in the driver region, and effective kTe reduction in the H0 converter. Observation of hyperthermal H0 (kTH0 > 1eV). High H0 flux from MWS driver. H- beam current and noise characteristics. Fourth talk is on H- source diagnostics. (Dan Swanson) Confidentiality statement: This document is the joint property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as jointly authorized by PNL.

Theoretical H- Yield from H0 on W(Cs) Solid line is theory from H. L. Cui, J. Vac. Sci. Technol. A9, 1823 (1991). H0 thermal energy measurements (solid dots) from S. T. Melnychuk and M. Seidel, J. Vac. Sci. Technol. A9(3), 1650 (1991). kT is H0 temperature. Work from Stevens Institute of Technology, Hoboken, NJ. Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Production of Hyperthermal H0 Hyperthermal H0 defined as H0 energies > 1eV. High electron temperature H2 plasmas leads to direct H2 dissociation to hyperthermal H0. The electron energy threshold for direct dissociation of state II in the adjoining figure is 8.8eV. The minimum dissociation energy of state II is 2.2eV. Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Cross Sections and Reaction Rates for Hyperthermal H0 Following discussion in Brian Lee’s thesis (Stevens Institute, 1993): Dissociation cross section Reaction rate Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Microwave Proton Source (MWS) as Driver for Hyperthermal H0 What do we know about the MWS from H+ production (CRL, LANL)? kTe ~ 20eV (from Chalk River Lab Langmuir probe measurements) J+ = 0.26A/cm2 Ne = 1.2 X 1012 e/cm3 N(H2) = 7.1 X 1013 H2/cm3 (molecular flow) H+ fraction 90% at ~ 1 kW 2.45GHz microwave power Continuity equation for H0 flux based on volume production (V) and surface (A) loss NeN(H2)<sve>V = nHovHoA/(4a) fH0 = nH0vH0/4 = 6.6 X 1018 H0/(cm2-s) (MWS) *Interesting observation: Based on 4.1sccm H2 flow rate in LANL MWS the neutral flux density effusing from the MWS is 4.7 X 1018 neutrals/(cm2-s) -> all H2 dissociated to H0! For 20% conversion efficiency (H0 -> H-), 15% solid angle efficiency, jH- = 24mA/cm2 remis = 0.4cm, IH- = 12mA, erms,n = (remis/2)(kTH-/mc2)1/2 = .065 (pmm-mrad), kTH-= 1eV No optimization of MWS for H0 production assumed, or, possible contribution to H- production from slow positive ions. Neutrons X-Rays Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Proposed Driver – H- Production Regions Classic Two Chamber H- Source H0 generator is MWS Dipole filter for reducing hot electrons Cesiated molybdenum converter (H0 -> H-). Cone exit aperture radius = 0.5cm Plasma electrode has remis = 0.4cm Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

30kV H- Extraction System PBGUNS simulation using H- plasma meniscus option. 10mA extracted current. Extraction gap = 27.2mm, emission aperture radius = 4mm, extraction aperture radius = 3.2mm kTH- = 1eV, erms,n (PBGUNS) = 0.10 (pmm-mrad) Co-extracted electrons separated from H- beam after extraction electrode by a dipole separation magnet. Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Expected H- Source Lifetime MWS discharge (2.45GHz, 875G ECR) can run very long time in cw mode (months). PNL has gained expertise in reducing EMI while developing 300keV positive ion accelerators. The MWS is most gas and power efficient cw H+ source known. PNL H- injector design will place most sensitive electronics at ground level, thus minimizing EMI problems (minimal equipment on 30kV deck). Recent work at the U.S. Spallation Neutron Source (SNS) has indicated a single cesiation of the converter cone may last two weeks or more without detriment to H- production. For this reason, the PNL design follows the SNS converter developments as closely as possible. The Cs oven proposed here will contain enough Cs for many Cs applications. There is good reason to suspect that the proposed source could operate at 10mA, 30keV in cw mode for several months. Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Ion Source Design Overview Plasma source Filter magnet Cesium converter Beam Extraction Beam diagnostics Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Design Goals Stable ECR plasma driver capable of producing high density and high temperature plasma for long run times. Adjustable electron temperature in Cs conversion region by use of filtering magnets. Efficient conversion of high temperature H+ ions and neutrals into H- ions though surface reactions with low work function materials. Extraction and acceleration of high quality beam. Incorporation of diagnostic instruments. Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Magnetic Design - Driver Frequency of cyclotron motion given by For 2.45 GHz microwaves and electrons, resonance match when B = 875 G [2] Best performance when resonance zones located near front and rear of plasma chamber. Field leakage outside driver reduced with iron/steel shunts. Minimize B in waveguide to reduce unwanted ionization. Minimize axial B in conversion region to improve magnetic filtering. Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Ion Source Chemistry Negative ions can be generated by surface ionization of hydrogen ions and atomic hydrogen. [3] H+ + 2e- → H- H + e- → H- Higher work function materials have lower conversion probability. Mo: 4.36-4.95 eV W: 4.32-5.22 eV Cs: 1.8 - 2.14 eV Cesium work function as low as 1.3 – 1.7 eV at thickness of about 0.6 monolayers. [1] Low binding energy (0.75 eV) of additional electron is beneficial to neutralization, but also makes H- ions vulnerable. Plasma parameters and background gas in conversion section are critical. 22 Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Cesium Source Commercially available alkali-metal dispenser. Cesium is stored in a stable chemical compound. Controlled release of pure Cs through decomposition reaction of compound and reducing agent. SAES Cs dispenser contains cesium chromate (Cs2CrO4), zirconium and aluminum. Production and release of pure Cs. Temperature driven rate above 625 oC 4 Cs2CrO4 + 5 Zr → 8 Cs(g) + 5 ZrO2 + 2 Cr2O3 6 Cs2CrO4 + 10 Al → 12 Cs(g) + 5 Al2O3 + 5 Cr2O3 Impurity management critical due to high chemical reactivity of cesium with residual gas. Cesiated surface electrically biased ~-100 V to promote deposition. 23 Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

H- Converter and Extraction 24 Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Magnetic Design - Filter A magnetic filter field cools the plasma before converter surface to reduce the destruction of negative ions by electron stripping. Electron temperature of ~10 eV in driver. Target electron temperature of 2 eV at converter surface. Difficulty: high-permeability plasma aperture plate to contain driver fields tends to shunt filter magnet away from desired location. Aperture chamfered to add distance between plate and filter while still containing driver fields. Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Magnetic Design - Filter Magnetic filter field lines Magnetic filter axial profile Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Thermal Design 295-625 oC minimum temperature for cesium dispenser, depending on compound. Cesium dispensers driven by small cartridge heaters or direct current. Thermally isolated with stainless or ceramic standoff. Cesiated surface cooled to selectively enhance deposition rate, 20- 200 oC. Heated/cooled by pressurized air loop with inline heater. H- ion production rate dependent on surface temperature, optimum around 150-200 oC. Plasma heating effects to be determined experimentally and adjusted for if necessary. Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Thermal Simulations 300 W cartridge heaters, 100 oC air 500 W plasma heating, 100 oC air Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Mechanical Design Driver and converter floated to -30 kV. Cs converter Driver and converter floated to -30 kV. Microwave hardware, diagnostics, and driver solenoids at ground. Use proven and existing PNL technology when possible. Modular design. Simple dis/assembly. Inclusion of diagnostics. Flexibility for contingency plans. Plasma chamber DC Waveguide break Magnetic filter Pumping stage -30kV Ground Ground Autotuner Circulator Faraday cup/ calorimeter Magnetron Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Diagnostic Techniques Calorimeter Atomic Flux Measurements to confirm the flux from the Driver is high enough. Faraday Cup Beam Current and Noise Measurements for assisting in determining the necessary strength of the filter magnet. Video Camera Mounted on the conflat cross Used for Beam Profile Measurements to visually verify the cross section of the beam. Optical Spectroscopy Plasma Density and Temperature Measurements to further help understand the plasma source and possibly detect impurities. Langmuir Probe Plasma Velocity, Temperature, and Flux Measurements to further assist in determining the necessary filter magnet strength. Confidentiality statement: This document is the joint property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as jointly authorized by PNL. 30

Faraday Cup Background Measure 30keV H- current; electron suppressor either electrostatic and/or magnetic (Electrostatic Shown) Beam noise measurement; expect bandwidth ~ 10 MHz Working with e/H- separation magnet (located immediately after 30kV extractor), deduce e/H- ratio Faraday Cup entrance aperture diameter (molybdenum plate) designed on the basis of the PBGUNS predicted divergence, and known drift distance to the Faraday Cup entrance 31 Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

H0 Calorimeter Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

H0 Calorimeter Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Beam Profile Measurement Design Concept Mounting a Video Camera on the conflat cross for viewing the beam profile There is a Window on the conflat cross for the Camera to view the beam through without being damaged We can assume we have an axisymmetric beam, so one Video Camera is sufficient If the coextracted electrons are seperated from the H- beam in the horizontal plane, it would be interesting to mount the camera in the vertical plane so the seperation of the two beams would be visible 34 Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Optical Spectroscopy Background Used for Plasma Density and Temperature Measurements Can also be used for detecting impurities and leaks in the system The change in wavelength at fwhm of an emission peak is due to Doppler broadening For the 656nm hydrogen line, this is about .15nm for 10eV and .05nm for 1eV. The resolution of the monochromator needs to be below these values. Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL 35

Optical Spectroscopy Light input options Lenses Potential exists for better performance Can require more sophisticated mounting and alignment hardware Needs transmission through a vacuum window and guarding against stray light Monochromator needs to be physically located as close to the vacuum wall as possible Fiber Optics No need to set and maintain precise alignment of components Vacuum feedthru is a stock part and creates no concern of external light noise 36 Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Optical Spectroscopy Data Collection Classical Monochromator 3737 Optical Spectroscopy Data Collection Classical Monochromator Has a single detector which measures the intensity of a single wavelength of light over time. Single wavelength is selected by mechanically shifting elements. This style is slower but has better resolution in .01 nm or better. Extra resolution provided here is not necessary for this application. Newly designed CCD collector Samples the entire available spectrum at once. Faster data collection is limited only by the required exposure time. Faster feedback allows for easier characterization of source plasma temperatures over a wide range of operating parameters. Neutrons X-Rays 37 Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Langmuir Probe Types of Probes 3838 Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Langmuir Probe Design Choice Single Cylindrical Probe Linear Feedthru Glass Tube for the insulating material Alumina for the main probe section Tungsten Wire for data collection 39 Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Langmuir Probe Theory can be found from the slope of vs. 4040 Langmuir Probe 4040 Theory Single Cylindrical Probe ] » can be found from the slope of vs. Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL 40

Diagnostics Summary Multiple Diagnostic Tools being used Calorimeter Video Camera Faraday Cup Optical Spectroscopy Langmuir Probe Multiple Values to be obtained Atomic Flux Beam Current, Noise, and Profile Measurements Plasma Density, Temperature, and Velocity 41 Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Conclusions PNL has demonstrated high current, long lifetime CW operation with a positive deuterium microwave ion source There is a good reason to believe that coupling this source with a Cs conversion cone will result in a high performance CW H- source with a long lifetime Preliminary designs have been completed Next step is pursuit of Phase II SBIR funding to build and test the H- ion source Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

QUESTIONS? Evan Sengbusch, PhD, MBA (608) 210-3060 sengbusch@phoenixnuclearlabs.com

References [1] Handbook of Ion Sources, Bernard Wolf, CRC Press, Inc., 1995 [2] NRL Plasma Formulary, Naval Research Laboratory, 2011 [3] Work function measurements during plasma exposition at conditions relevant in negative ion sources for the ITER neutral beam injection, R. Gutser, C. Wimmer, and U. Fantz, 2011 [4] Fusion Physics, IAEA, 2012 Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL

Contingency Planning – Identify Design Areas That Could Be Challenging PM instead of electromagnet driver source. Better control of kTe in the converter region and Cs oven temperature control. May have complications of the electromagnet and dipole filter fields. Modification to Cs oven, converter cone, and tube for: Thermal loading surprises Hyperthermal H0 incident angle on Cs converter cone Coextracted electron dump options Weak or strong dipole magnet after 30keV beam formation? Present design is for weak field so H- beam direction correction is minimal. Preferred option. Dump coextracted electrons on electrode with intermediate potential. Seems unattractive for cw beam reliability to dump electrons in the extraction field. Confidentiality statement: This document is the property of Phoenix Nuclear Labs and may not be copied, used, or disclosed for any reason except as authorized by PNL