An introduction to Ultraviolet/Visible Absorption Spectroscopy

Slides:



Advertisements
Similar presentations
Spectrophotometer.
Advertisements

Jeopardy Q 1 Q 6 Q 11 Q 16 Q 21 Q 2 Q 7 Q 12 Q 17 Q 22 Q 3 Q 8 Q 13
Jeopardy Q 1 Q 6 Q 11 Q 16 Q 21 Q 2 Q 7 Q 12 Q 17 Q 22 Q 3 Q 8 Q 13
ABC Technology Project
Chapter 25 Instruments for Optical Spectroscopy
Spectrochemical Instrumentation Modules
UV instrumentation Abu Yousuf, PhD Associate Professor Department of Chemical Engineering & Polymer Science Shahjalal University of Science & Technology.
25 seconds left…...
We will resume in: 25 Minutes.
11 Components of Optical Instruments Lecture Spectroscopic methods are based on either: 1. Absorption 2. Emission 3. Scattering.
SPECTROSCOPY.
Atomic Absorption Spectroscopy Prof Dr Hisham E Abdellatef 2011.
1 Molecular Luminescence Spectroscopy Lecture 31.
Spectrophotometric Analysis
Atomic Absorption Spectroscopy
Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry Absorption measurements based upon ultraviolet and visible radiation.
AN INTRODUCTION TO ULTRAVIOLET/VISIBLE ABSORPTION SPECTROSCOPY
Ultraviolet – Visible Spectrophotometer. What is UV – Vis spectroscopy? Ultraviolet – visible spectroscopy is a measure of the absorbance of radiation.
Introduction to Instrumental Analysis - Spectrophotometry
Dr. Maha Al-Sedik. Objectives:  Electromagnetic Radiation  White light  Beer’ s law  Spectrophotometer  Components of spectrophotometer  Types.
What is spectroscopy? It is the study of how matter interacts with electromagnetic radiation (gamma rays down to radio waves) Matter can interact with.
Principles of instrumentation Prepared by: Ibtisam H. AlAswad Reham S. Hammad.
Atomic Emission Spectrometry By: Alexa Kunch
Spectrophotometer Prof.Dr. Moustafa M. Mohamed Vice Dean Faculty of Allied Medical Science Pharos University in Alexandria, EGYPT.
Fluorometric determination of riboflavin
Fluorometric determination of riboflavin. Introduction.
UV-Vis Absorption Spectroscopy
Fluorometric Analysis
Simple Double Beam Spectrometer
SPECTROPHOTOMETRY IN BIOTECHNOLOGY
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 19 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Chapter 13 An Introduction to Ultraviolet- Visible Molecular Absorption Spectrometry.
Spectrophotometry.
Introduction to Spectrochemical Methods
1 Introduction to Atomic Spectroscopy Lecture 10.
Colorimeters or photometers
Spectrophotometer.
SPECTROPHOTOMETRY. Principle : there is interaction between the light and sample particle, spectrophotometer is employed to measure the amount of light.
CLS 332 CLINICAL INSTRUMENTAL ANALYSIS. A VISIBLE ABSORPTION SPECTROMETER.
1 Atomic Emission Spectroscopy Lecture Qualitative analysis is accomplished by comparison of the wavelengths of some emission lines to standards.
Summary: (Last lecture) Absorption spectroscopy definition electromagnetic spectroscopy matter absorption spectroscopy fundamental terms (transmittance,
Photometry.
Fluorometric determination of riboflavin
Spectroscopy and Atomic Spectra A satellite orbiting the Earth contain gravitational potential energy. The satellite can orbit the Earth at any height.
Spectrophotometry at a Glance
COLORIMETRY & SPECTROPHOTOMETR
Cairo University Faculty Of Engineering chemical engineering department SPECTROPHOTOMETER.
Lab1 A VISIBLE ABSORPTION SPECTROMETER. -One of the simplest and most widely used methods to determine concentration of a substance in solution -Measures.
Principles of instrumentation. Photometry - Photometry means “the measurement of light” If a substance can be converted to a soluble, colored material,
Lab1 A VISIBLE ABSORPTION SPECTROMETER
Chem. 133 – 3/14 Lecture.
Laboratory equipment Lecture (4).
Beer-Lambert law Gihan Gawish.Dr.
Principles and practice of Spectrophotometer
Spectrophotometer - Visible Type Spectro - photometer consists of two instruments : Spectrometer   Photometer  Spectrometer   for producing light.
Colorimeters or photometers
Chapter 13 Chapter 13 Chapter 13 Chapter 13 Chapter 13 Chapter 13
Spectrophotometer Dr . S. Jayakumar.
Measurements involving light –A Basic Principles and Instrumentation
Dnyanasadhana College, Thane. Department of Chemistry T. Y. B. Sc
INTRODUCTION TO SPECTROSCOPIC METHODS OF ANALYSIS
Colorimeters OR photometers
Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry.
SPECTROPHOTOMETRY Applied Chemistry.
Instrumentation for UV and visible absorption
Advanced Pharmaceutical Analysis UV spectroscopy
Clinical instrumental analysis
Spectrophotometric Analysis
Presentation transcript:

An introduction to Ultraviolet/Visible Absorption Spectroscopy Lecture 24

Light Sources (commercial instruments) D2 lamp (UV: 160 – 375 nm) Instrumentation Light source  - selector Sample container Detector Signal processing Light Sources (commercial instruments) D2 lamp (UV: 160 – 375 nm) W lamp (vis: 350 – 2500 nm)

Sources Deuterium and hydrogen lamps (160 – 375 nm) D2 + Ee → D2* → D’ + D’’ + h

Deuterium lamp UV region (a) A deuterium lamp of the type used in spectrophotometers and (b) its spectrum. The plot is of irradiance Eλ (proportional to radiant power) versus wavelength. Note that the maximum intensity occurs at ~225 m.Typically, instruments switch from deuterium to tungsten at ~350 nm.

A tungsten lamp of the type used in spectroscopy and its spectrum Visible and near-IR region A tungsten lamp of the type used in spectroscopy and its spectrum (b). Intensity of the tungsten source is usually quite low at wavelengths shorter than about 350 nm. Note that the intensity reaches a maximum in the near-IR region of the spectrum.

The tungsten lamp is by far the most common source in the visible and near IR region with a continuum output wavelength in the range from 350-2500 nm. The lamp is formed from a tungsten filament heated to about 3000 oC housed in a glass envelope. The output of the lamp approaches a black body radiation where it is observed that the energy of a tungsten lamp varies as the fourth power of the operating voltage.

Tungsten halogen lamps are currently more popular than just tungsten lamps since they have longer lifetime. Tungsten halogen lamps contain small quantities of iodine in a quartz envelope. The quartz envelope is necessary due to the higher temperature of the tungsten halogen lamps (3500 oC). The longer lifetime of tungsten halogen lamps stems from the fact that sublimed tungsten forms volatile WI2 which redeposits on the filament thus increasing its lifetime. The output of tungsten halogen lamps are more efficient and extend well into the UV.

Tungsten lamps (350-2500 nm) Why add I2 in the lamps? W + I2 → WI2 Low limit: 350 nm Low intensity Glass envelope

3. Xenon Arc Lamps   Passage of current through an atmosphere of high pressured xenon excites xenon and produces a continuum in the range from 200-1000 nm with maximum output at about 500 nm. Although the output of the xenon arc lamp covers the whole UV and visible regions, it is seldom used as a conventional source in the UV-Vis. The radiant power of the lamp is very high as to preclude the use of the lamp in UV-Vis instruments. However, an important application of this source will be discussed in luminescence spectroscopy which will be discussed later.

Sample Containers Sample containers are called cells or cuvettes and are made of either glass or quartz depending on the region of the electromagnetic spectrum. The path length of the cell varies between 0.1 and 10 cm but the most common path length is 1.0 cm. Rectangular cells or cylindrical cells are routinely used. In addition, disposable polypropylene cells are used in the visible region. The quality of the absorbance signal is dependent on the quality of the cells used in terms of matching, cleaning as well as freedom from scratches.

Instrumental Components Source  - selector (monochromators) Sample holders Cuvettes (b = 1 cm typically) Glass (Vis) Fused silica (UV+Vis) Detectors Photodiodes PMTs

Types of Instruments Instrumental designs for UV-visible photometers or spectrophotometers. In (a), a single-beam instrument is shown. Radiation from the filter or monochromator passes through either the reference cell or the sample cell before striking the photodetector.

1. Single beam Place cuvette with blank (i.e., solvent) in instrument and take a reading  100% T Replace cuvette with sample and take reading  % T for analyte (from which absorbance is calc’d)

Most common spectrophotometer: Spectronic 20. On/Off switch and zero transmission adjustment knob Wavelength selector/Readout Sample chamber Blank adjustment knob Absorbance/Transmittance scale

End view of the exit slit of the Spectronic 20 spectrophotometer pictured earlier

Single-Beam Instruments for the Ultraviolet/Visible Region

Single-Beam Computerized Spectrophotometers Inside of a single-beam spectrophotometer connected to a computer.

2. Double beam (most commercial instruments) Light is split and directed towards both reference cell (blank) and sample cell Two detectors; electronics measure ratio (i.e., measure/calculate absorbance) Advantages: Compensates for fluctuations in source intensity and drift in detector Better design for continuous recording of spectra

General Instrument Designs Double Beam: In - Space Needs two detectors 22

General Instrument Designs Double Beam: In - Time

Merits of Double Beam Instruments Compensate for all but the most short term fluctuation in radiant output of the source Compensate drift in transducer and amplifier Compensate for wide variations in source intensity with wavelength

Dual Beam Instruments