Mobile Radiography Course

Slides:



Advertisements
Similar presentations
“Power Factor” In Transmission System
Advertisements

LED Drivers Al Marble Manager, Sales & Market Development January 2010.
Amateur Radio Technician Class Element 2 Course Presentation ELEMENT 2 SUBELEMENTS T1 - FCC Rules, station license responsibilities T2 - Control operator.
Electrical Systems Chapter 9.
Technique Guidance Systems
HVAC523 Heat Sources.
Electronic Power and Control Electronic Power and Control
Special Imaging Systems
Mobile Radiographic Equipment. Introduction In-patients who could not leave their beds In-patients who could not leave their beds Surgeons who required.
Lighting concepts – Ballasts and Lighting Controls
HS-30 Hydrostatic Pressure Sensor Presented By Peter Ward Hydrological Services Pty Ltd.
Line focus principle Heal effect Ratings Tube failure
An Electronic System Power Supply Example
ENERGY INDUSTRY FUNDAMENTALS: MODULE 1, UNIT A --The Evolution of the Power Industry and Its Regulatory Structure.
Chapter 11 Prime Factors.
AC CIRCUITS Every slide contains valuable and need-to-know information that has to be understood and retained before proceeding. Throughout this PowerPoint.
Thermostats, Pressure Switches, and Other Electric Control Devices
Rad Tech 110 Circuits.
CIRCUITS AND ELECTRICAL FLOW. The amazing image which follows shows a picture of earth taken at night from outer space. The street and house lights illuminate.
DC Choppers 1 Prof. T.K. Anantha Kumar, E&E Dept., MSRIT
Magnetic Field Patterns
The X-Ray Circuit.
DC Choppers 1 Prof. T.K. Anantha Kumar, E&E Dept., MSRIT
Presented By: Er. Ram Singh (Asstt. Prof.) Deptt. Of EE
Copyright by UNIT III DC Choppers 4/17/2017 Copyright by
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
X-Ray Production & Emission
Electronic Components
The X-ray Imaging System
Resident Physics Lectures
1 1 Electricity Introduction. 2 Electricity Current Four (4) requirements for an electrical current. 1An abundance of electrons (-) 2A scarcity of electrons.
Automotive Batteries Chapter 29.
Chapter 22 Alternating-Current Circuits and Machines.
Speed Control of D.C. Motors
Electricity and Electrical Circuits Part 1 - Introduction
Chapter 4 Rectification and Rectification Systems.
Batteries Storing Renewable Energy “Chemical engines used to push electrons around”
Basic of Electricity Discuss the electrical properties of matter. Define voltage, resistance, impedance, current, and circuits.
Electrical Energy & Current. Introduction to Electric PE, Electric Potential, and Potential Difference Intro to Electric Potential.
Ch. 2 – Anatomy of the X-ray Machine
UNIT-1 Rectifiers & Power Supplies. Rectifier A rectifier is an electrical device that converts alternating current (AC), which periodically reverses.
Diodes and Diode Circuits
Static Electricity Static electricity: electric charge that can be collected and held in one place (static means not moving/changing). Static electricity.
Rad T 290 Generators. Generator Components control console  kVp adjust  mA adjust  time adjust transformer  high voltage (step up)  filament »low.
Power and Power Measurement ENGR 10 – Intro to Engineering College of Engineering San Jose State University (Ping Hsu and Ken Youssefi) 1 Introduction.
SPH3U Electricity & Circuits
“Zip Zap”. Electrical Safety Charges What is a Circuit? An electric circuit consists of: –A source of electrical energy (battery or cell) –A user.
Chapter 17 Power in AC Circuits.
Investigating Basic Circuits Post-Activity Discussion
The Control of Electricity in Circuits
Medical Equipment Technology Department 1 Introduction to Biomed. Imaging Systems Lecture No.5-6 Dr. Yousif Mohamed Y. Abdallah.
CLOSED LOOP SPEED CONTROL OF DC MOTOR WITH PWM TECHNIQUE
An early x-ray by Wilhem Rontgen
8 November 1895, produced and detected electromagnetic radiation in a wavelength range today known as X- rays or Röntgen rays, electromagnetic radiationwavelengthX-
3 July July July Conventional X-rays Generator Basic components of an X-ray machine:  Electron source.  Vacuum where electrons were.
Chapter 4: Diagnostic X-Ray Production
Introduction High Voltage!!.
Rectification Systems
ELECTRIC TRACTION SYSTEM
Introduction To Reactive Power
TRIODE TUBES.
Resident Physics Lectures (Year 1)
DC Choppers 1 MH1032/brsr/A.Y /pe/DC CHOPPERS
Electric braking Powerpoint presentation by:- Poonam sharma
Resident Physics Lectures (Year 1)
Portable and mobile radiographic unit
Presentation transcript:

Mobile Radiography Course Instructor :TAGELDIN ABUGROON

Overview RAD 323 Course Mobile Equipment features. Mobile Image Intensifier Units (C arm) Work with Mobile Equipment in the Ward. Sterilization. Tomography. Introduction to Digital Radiography.

Mobile Equipment Feature

Introduction What is mobile x-ray equipment? It is equipment which can be moved from one place to another and used at the patient’s bedside. What is used for? It can be used to provide facilities for the following cases: (1) In-patients who could not leave their beds, especially those who cannot be moved away from their ward. (2) Surgeons who required X-ray control guidance during the course of their work in the operation theatre.

These days bedridden patients who are in need of radiography are now transferred safely from their ward to the imaging department, where they can be examined with all the efficiency that the department can offer. These facilities include full radiation protection: for the patient, of course, but also for other personnel who otherwise, in the hospital ward, could have been at risk. Therefore, their use should be restricted. Despite these points, the service of mobile X-ray equipment can be in demand all day especially in a busy hospital and with complicated situation patient. Study of the principal features of their construction and operation is necessary, as always, for correct and safe use.

What are the differences between mobile & portable unit? The broad distinction between the two being the difference in power output and the ability to transfer equipment. Portable units are small and light in weight, which normally can be dismantled and carried, usually by one person, and have relatively low radiation output. While Mobile x-ray units are bigger and heavier than ‘Portable’ units which is movable but because of its weight and size can only be wheeled along flat surfaces to place where required, they are usually have higher radiation output.

Portable unit which can be dismantled & carried by one person

P=I.E Portable units features Advantages: 1- Light weight. 2- Standard power supply. Disadvantages 1- Low output. 2- Lack of stability. 3- Lack of precision. The output of the machine can be determined by The following equation: Where: P= Power (Watt) I= Current (Amper) E= Voltage (Volt) P=I.E

Example: Exposure factors: 100 kVp, 50 mA. Supply: 240 V P= _50_ A × 100,000 = 5000VA 1000 I= 5000 = 21A 240 if we change the Volts to 480V, what would be happened? I= 5000 =10.5 A 480 As we increase the line voltage, the current flowing is reduced. Therefore the output of the machine will be decreased. Remember that changing the exposure factors change the current requirements. Therefore you need to know the current required and the voltage of the power supply before you do exposure.

Components of Portable units: 1- Oil-Filled lead lined tank: In order to make the equipment simpler, lighter, less expensive and easy to carry, it is usually constructed with: (A) X-ray tube: Self-rectified, Stationary anode. (B) High-tension transformer. (HTT) (C) Filament transformer. This is described as a tank construction and the whole enclosure is called the tube head. 2- A small control unit: (A) Rheostats: to vary the mA and kV. (B) Timer (S). (C) Exposure switches. Output: The maximum output is usually 80 kVp and 20 mA.

Mobile units feature: Capable of being moved either manually or motorized drive. Advantages 1. Great stability. 2. High output. 3. Wide range of KV & mA selections. 4. The control panel and the high tension generator (with full-wave rectification) all are carried by strong machine base, away from the tube which have an advantage to greatly increased the x-ray output. 5. It has a rotating anode. 6.Flexible tube movement.

Disadvantages: 1. It is heavy in weight. 2. It needs especial maintenance. Output Up to 300 mA and maximum of 125 kVp.

Mobile Unit in 1940 -1955

Mobile units

7 6 5 8 4 3 2 9 10 11 1 12

Construction of Mobile Unit: 1.High generation tank containing the HT transformer 2. Handle for pushing the unit. 3. Control unit. 4. Lock. 5. Tube Column. 6. Bowden cable allowing vertical movement of the cross arm. 7. Movement of the cross arm. 8. Hinge joint to allow extension of the cross arm. 9. HT cables. 10. Column base allowing rotation of the cross arm around column. 11. Base plate. 12. Large wheels for easy movement.

Mobile units Classification They are classified by two ways: output & Power Supply. (A) By output: 1-Low Power Mobiles : These operate at max. x-ray current (mA) of 10 to 30 with a range of 40 to 90 kVp. Example: Dental, war x-ray equipment. 2- Average Power Mobiles : These operate at a range x-ray current (mA) of 50 to 60, 100 to 150 mA with a range of 40 to 90 kVp, 95 kVp. Example: for skull, limbs. 3-High power mobiles : These operate at max. of 300 mA, at a max. 125 kVp. Example: for CXR , abdomen, skull, Pelvimetry, IVU, pediatrics.

Main Supply Equipment Advantages & disadvantages: Energy may be drawn for X-ray exposure directly from the mains voltage supply. This is convenience if there is no need for the energy to be carried around within the mobile unit. But cable resistance and supply variation at different locations where the unit is used can raise difficulties affecting image quality.

Special Features This kind of equipment must have a robust connection cable. This encloses 3 low resistance conductors, each with a relatively large cross-sectional area. Two of the conductors carry the current, which the generator draws when an exposure is made. The third provides a safe, reliable connection to earth. The cable must be long enough (2 meter) for equipment to be used in most locations, provided there is a convenient mains outlet socket, but not so long that its resistance becomes significant. The cable should be manufactured to tolerate physical damage.

Capacitor Discharge Equipment Advantages & disadvantages 1.Small in size and light in weight, because there is no H.T.T. 2.This unit has the advantage of storing energy in the form of electric charge for later use for X-ray exposures. Therefore, it can be used in places where there is no electricity, or no a convenient mains outlet socket, or there is electrical power but not adequate (not enough to operate the X-ray unit), or suffers ‘drops’ in its values. 3.The unit has the advantage of providing high X-ray output (usually high mA). The given kVp is from 30 or 40 up to 100 to 125 kVp and 500 mAs.

4.Shorter exposure time. By using grid-controller, this grid plate is exist between the anode and the cathode in the tube. This grid allow the electrons to pass through it and reach the anode (by carrying zero charge or no charge on it), this grid can stop the electrons passage after a specific time by carrying -ve charge on it which will reverse action and stop the exposure. 5.It has no timing control device since only the kVp has to be selected, so the mAs depends on the kVp. As the kVp in the capacitor discharge falls the mAs does so. 6.Simple in operation, it can be supplied by any voltage from 60V to 220V (so we shouldn’t worry from voltage fluctuation).

7.Provides consistently reliable output and results (uniform wave), which has the advantage of less absorbed dose to the patient and good image quality. This consistency happened because the main voltage and resistance variations only have their effects upon the act of charging the capacitor, which takes place just before the X-ray exposure is made. While in the mobile unit that use the conventional generator provide the X-ray tube with a pulsating waveform voltage which varies from peak to zero then go back to peak which effect the image quality and patient protection. 8.Capacitor discharge is usually limited so that the drop in kVp is only 35% on heavy exposure. 9.The disadvantage that it has the limitation in exposures. Few times of exposure needs capacitor charge.

Working of the Capacitor Charging Stage After the radiological Technologist connects the unit to the mains and selects a kVp value, the switch operated to charge the capacitor to the required kVp (G1 & G2 will be connected), via the high tension generator, then the capacitor acts as a store or source of energy. Discharging-exposure stage By pressing the exposure switch the X1 & X2 will be connected then the capacitor will discharges electrons through the X-ray tube and produce X-ray exposure.

Special Features 1.Charging circuit contains solid-state rectifiers (selenium types) and capacitors these two acts as energy storing elements and as voltage multipliers (raise voltage to higher kV values, instead of the high-tension transformer). 2.The size of the capacitor determines the maximum output (mAs); this is called Capacitance Value (C.V.). For example; if the typical C.V. for charging capacitor is 1.0 the typical mAs are between 0.4-60 mAs. After every exposure we do the mAs will be reduced. 3.Its tube has rotating anode and grid-controller.

Battery Powered Generator This is called also cordless mobile unit (mains-independent). This unit use batteries as a source of energy for X-ray exposure. Advantages: (1) This machine can be used freely, provides wide range of satisfactory kVp & mAs. (2) This machine could be recharging less frequently that the capacitor one. Some machine allows you to take up to 500 exposures without re-charging. Disadvantages: It needs special care and maintenance.

Special Features: This kind of machine usually uses 2 batteries of car kind 12V (24v d.c.). All batteries are sealed for safety. Charging is achieved by connecting the generator to the mains at times when it is not required for radiography. These batteries also used as a motor for the unit wheels that makes the driving of the machine much easier. The batteries need regular care and maintenance. If the machine is well maintained, it could last up to two years of their working life.

Care & Maintenance of Battery powered Generator This care and maintenance includes: (A) The unit should be left connected to the mains power supply of (200v or 115v): – Every night. – During weekends. – At all times when the unit is idle (not being used). (B) Naked flames or lighted cigarettes should not be held near the batteries when they are being charging up (because of the risk of the hydrogen gas explosion). (C) The acid level in the batteries should be checked every 2 weeks. Its proper recommended level is 6.0 mm above the plate separation. If the level drops below this, distilled water (only) must be added.