The stimulus for your Energy Initiative. THERE CAN BE ECONOMY ONLY WHERE THERE IS EFFICIENCY ….... BENJAMIN DISRAELI, FORMER BRITISH PRIME MINISTER What.

Slides:



Advertisements
Similar presentations
UC-Irvine Meeting Identifying Energy Saving Opportunities in Process Heating through Waste Heat Recovery and Power Generation Bryan Warren Southern.
Advertisements

ACTIVE LEARNING PROCESS
ME 416/516 Basic Energy Units, Terms and Calculations War Eagle! Roll Tide!
Heating, Ventilation, and Air-Conditioning (HVAC) Systems
WHICH OF THE FOLLOWING STATEMENTS ABOUT AIR COOLED CONDENSERS IS CORRECT? A.MORE EXPENSIVE THAN WATER COOLED CONDENSERS. B.HIGH MAINTENANCE. C.LIMITED.
22 electrical Quantities
Energy-Efficient Process Cooling
* A chiller capable of producing water temperatures of low 40s on the evaporator side and above 135° on the condenser side.
MAO Flow Meters Sales Deck | Presentation Title What is the MAO Flow Meter? The MAO flow meter is an instrument used for monitoring or measuring.
1 1 BASICS OF ENERGY MANAGEMENT Section A - Energy Basics.
Power Plant Engineering
Lecture Notes - Energy Conservation Topic “Boiler”
HVAC 11a CNST 305 Environmental Systems 1 Dr. Berryman
Heat and Power Sources for Buildings. Overview energy requirements of buildings traditional energy sources carbon emissions calcs LZC energy sources –low-carbon.
UCSD Medical Center - Hillcrest Campus Case Study Gerry White Facilities Design & Construction University of California, San Diego.
ENERGY SAVING IN STEAM GENERATION AND TRANSPORT IN FOOD INDUSTRY
Energy Efficient Steam Systems
1 © GDC Group Heat Solutions. Source; House Hold budget survey (2004/2005) Irish Heating Market.
Heating, Ventilating, and Air-Conditioning
Senergy Consultants (P) Ltd
Factor of Evaporation: lbs/hr steam produced per BHp.
Objectives Describe the lighting parameters Learn about lamps Define project 2.
POWER FACTOR IN ELECTRICAL ENERGY MANAGEMENT
Lindbergh Field International Airport New Terminal Bill Mahoney LSW Engineers.
Energy Management Practices: Rolling Mills 1. Contents Introduction Energy Intensive Processes & Reduction in Energy Expenditure through Innovative Practices.
INTRODUCTION. Seminar on IMPROVEMENT OF THERMAL EFFICIENCY BY RECOVERY OF HEAT FROM IC ENGINE EXHAUST.
Engine Cooling And Lubrication
ENERGY SURVEYING Please Click through this presentation.
1 Optimizing the Efficiency of the NCAR-Wyoming Supercomputing Center Ademola Olarinde Team Member: Theophile Nsengimana Mentor: Aaron Andersen August.
Thermostats, Pressure Switches, and Other Electric Control Devices
HEAT PUMPS.
Moisture to water converter. Out Line : Abstract Introduction Heat Pump Heat Pump Components Conclusion.
Basic Refrigeration Cycle
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
1 Training Session on Energy Equipment Monitoring Equipment Presentation to Industry Energy Efficiency Guide for Asia Chapter 15 © UNEP GERIAP Monitoring.
ENERGY AUDIT INSTRUMENT
STEAM CONDENSERS.
Cogeneration.
Pharos University جامعه فاروس Faculty of Engineering كلية الهندسة Petrochemical Department قسم البتروكيماويات PE 330 ENERGY CONSERVATION LECTURE (5) Flue.
Steam Power Station Presented By Ashvin G. Patel Asst. Prof. (E.E.)
1 By Zenith Energy Services (P) Limited Hyderabad Presentation on Surat Textile Cluster Surat, Gujarat State.
Plant Utility System (TKK-2210) 14/15 Semester 4 Instructor: Rama Oktavian Office Hr.: M-F
Heat Transfer Equations For “thin walled” tubes, A i = A o.
NOVO ETS IMPROVING YOUR ORGANIZATIONS’ ENVIRONMENTAL, HEALTH AND SAFETY PERFORMANCE ENERGY MANAGEMENT IN THE CONTEXT OF GREEN PRODUCTIVITY.
CHAPTER 5: Mass and Energy Analysis of Control Volumes
Section 3 Using Heat.
Generating Stations. Bulk electric power is produced by special plants known as generating stations or power plants. Depending upon the form of energy.
STEAM POWER PLANTS.
ENERGY EFFICIENCY IN THERMAL UTILITIES AND SYSTEM
A Seminar On Suratgarh Super Thermal Power Station (Raj.)
Thermal Power Station.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
THERMAL POWER PLANT.
Week 11 Data Collection: meters and instruments – commercial.
I Need A Space Heating System Let’s Look At A Central Steam Plant Option.
HEAT-GENERATING EQUIPMENT INTRODUCTION SELECTION EFFICIENCY FURNACES BOILERS CENTRAL HVAC SYSTEMS.
Energy Management Standard Registered Investigation Body Authorized by the Ministry of Economy, Trade and Industry (METI) ECO-CHECK NETWORK JAPAN.
Thermal power plant , panipat
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Unit 13 Oil-Burning Equipment
Energy measuring Instruments
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
HVAC EQUIPMENT: COOLING SOURCES (see Chapter 16)
Energy Audit Instruments
Applied Thermal Engineering
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Energy Management Introduction Rantharu Attanayake BSc. (Eng), MSc, MBA EE – Energy Management Mobile :
Presentation transcript:

The stimulus for your Energy Initiative

THERE CAN BE ECONOMY ONLY WHERE THERE IS EFFICIENCY ….... BENJAMIN DISRAELI, FORMER BRITISH PRIME MINISTER What spices are to food, Performance Testing is to energy management! The journey of energy conservation starts with efficiency improvement and matures to effective utilization. Add the stimulus of performance testing to your energy Test Buds with our EnerSpices program….

TrendSpices Analysis of historical data of electricity bills, fuel bills and production data for past 24 months to identify tariff related benefits, demand management opportunities etc. Rs.15000/- per plant (Maximum of three energy meters) May-06Jun-06Jul-06Aug-06Sep-06Oct-06Nov-06Dec-06Jan-07Feb-07Mar-07Apr-07 Month kWh

ElecSpices TRANSFORMER EFFICIENCY : To find out transformer efficiency and possibilities of efficiency improvement by measurement of necessary electrical parameters at transformer and load profile. Comparison of transformer performance at various loads with manufacturers test certificate Rs. 15,000/- per transformer DIESEL GENERATING SET : To find out fuel consumption per unit generated by measurement of power generated, fuel consumed, flue gas temperature and % CO2 in flue gas Rs. 10,000/- per set

ElecSpices MOTOR LOADING: To identify partially / over loaded motors by measurement of parameters like power factor, input voltage / current and power drawn from mains Charges per motor up to 10 th motor: Rs. 500/- per for 11 th to 30 th motors : Rs. 400/- per for 31 st to 60 th motors : Rs. 350/- per for 61 st to 100 th motors : Rs. 300/- per 101 st motor onwards : Rs. 250/- per

ElecSpices HARMONICS MEASUREMENT: Measurement of total harmonic distortion in voltage and current waveforms at key location by power analyzer Rs.15,000/- per PCC EARTH PIT TESTING: Measurement of earth resistance to identify faulty earth pits and earth continuity through out the entire distribution network Rs. 5,000/- per 5 pits or part thereof

ElecSpices THERMOGRAPHY : Thermo graphic snapshot of PCCs, MCCs to identify overheating areas and thereby affecting safety limits Rs. 30,000/- per day HEALTH OF POWER FACTOR IMPROVEMENT CAPACITORS : To identify faulty capacitors, additional capacitors to improve power factor and possibilities of connecting APFC panel Rs. 5,000/- per 500 kVAR

ElecSpices LIGHTING: To find out installed light efficacy by measurement of Lux level at various locations and power consumed by respective lamps Rs. 5,000/- per 2500 square feet

ThermSpices BOILER EFFICIENCY: To find out boiler efficiency and evaporation ratio by measurement of parameters like temperatures, pressures, flow rates for fuel/water/steam/flue gas Charges per boiler Non-IBR boiler: Rs. 5,000/- IBR Smoke tube oil fired boilers Upto 10 TPH capacity: Rs. 10,000/- 11 to 30 TPH capacity: Rs. 15,000/-

ThermSpices BOILER EFFICIENCY: Charges per boiler IBR coal or solid fuel fired boilers Upto 10 TPH capacity: Rs. 15,000/- 11 to 30 TPH capacity: Rs. 20,000/- High pressure power generation boilers (with super heater) Upto 30 TPH capacity: Rs. 30,000/-

ThermSpices THERMIC FLUID HEATER EFFICIENCY: To find out Thermic fluid efficiency by measurement of parameters like CO 2 % temperatures of flue gas, pressures, power consumption of TF circulation pump Charges per Thermic fluid heater: Oil fired upto 1 MKcal/hr: Rs. 10,000/- Coal fired upto 1 MKcal/hr: Rs. 15,000/- Oil fired 1 to 5 MKcal/hr: Rs. 15,000/- Coal fired 1 to 5 MKcal/hr: Rs. 20,000/- Oil fired above 5 MKcal/hr: Rs. 25,000/- Coal fired above 5 MKcal/hr: Rs. 30,000/-

ThermSpices STEAM TRAP EVALUATION: Performance evaluation, identification of ineffective steam traps & additional requirement to ensure delivery of steam at right pressure for the process Rs. 5,000/- per 20 traps OR part thereof

ThermSpices STEAM SYSTEM EVALUATION: To find out efficiency of steam distribution by measurement of surface temperatures, pipe length, insulated and un-insulated surfaces and steam trap performance Rs. 10,000/- per 250 meters and 20 traps OR part thereof

ThermSpices FURNACE EFFICIENCY To find out furnace efficiency and specific energy performance by measurement of furnace surface temperature, quantity of material heated, fuel- electrical consumption, flue gas temperature Charges per Furnace: Oil fired upto 1 MKcal/hr: Rs. 15,000/- Coal fired upto 1 MKcal/hr: Rs. 20,000/- Oil fired 1 to 5 MKcal/hr: Rs. 20,000/- Coal fired 1 to 5 MKcal/hr: Rs. 25,000/-

MechSpices CHILLER PERFORMANCE EVALUATION To find out power consumption per ton of refrigeration by measurement of chilled water flow rates, temperatures at the inlet and outlet of evaporator, condensers and power consumed by compressor Rs. 25,000/- per chiller: Consisting of 1 chiller, 1 cooling tower and 3 pumps (primary, secondary and cooling tower) Rs. 3000/- per extra pump

MechSpices AIR HANDLING UNIT: Assessment of performance of AHU by measurement of air flow, pressure and dry/wet bulb temperature at supply and return side Up to 15 AHURs. 2000/-each From 16 to 40 AHUsRs. 1800/-each From 41 to 100 AHUsRs. 1500/-each

MechSpices COOLING TOWER: To find out cooling tower effectiveness and liquid/gas ratio by measurement of cooling water flows, air flows, dry/wet bulb temperatures and power consumed by fans and pumps Charges per cooling: Rs. 15,000/- including 1 fan and 1 pump

MechSpices AIR COMPRESSOR: To find out actual free air delivery, specific power requirement, volumetric efficiency and isothermal power required by conducting pump up test on the compressor and measurement of input power. Charges per compressor: Upto 5 compressorsRs. 7500/- Above 5 compressors Rs. 5000/-

MechSpices CENTRIFUGAL PUMP: To find out pump efficiency at operating conditions and system resistance and operating duty point of the pump by measurement of flow, pressure, head and power consumed Charges per pump set: Upto 5 pump setsRs. 5,000/- for 6 to 30 pump setsRs. 4,000/- for 31 pump sets onwardsRs. 3,000/-

MechSpices FANS AND BLOWERS: To find out volume flow rate and power input to fan shaft by measurement velocity of air in the duct and power consumed by the fan/blower Charges per fan or blower: Upto 5 fans or blowersRs. 4,500/- for 6 and above fans or blowersRs. 3,000/-

InstruSpices ULTRASONIC FLOW METER: This a non contact flow measuring device using Transit Time Effect principle. There is a transmitter and receiver which are positioned on opposite sides of the pipe. The meter directly gives the flow. Water and other fluid flows can be easily measured with this meter. Rs. 8,000/- instrument rental charges per day including technician

InstruSpices POWER & HARMONIC ANALYZER These are instruments for measuring major electrical parameters such as kVA, kW, PF, Hertz, KVAr, Amps and Volts. In addition these instruments also measure harmonics and power quality parameters. Rental charges per day: Rs. 2000/- for 1 CT and Rs. 4,000/- for 3 CT instrument including technician

InstruSpices ORSAT FLUE GAS ANALYZER: A hand bellow pump draws the flue gas sample into the solution inside the Orsat. A chemical reaction changes the liquid volume revealing the amount of gas. Percentage Oxygen or CO 2 can be read from the scale. Rs. 3,000/- instrument rental charges per day including technician

InstruSpices INFRARED PYROMETER: This is a non-contact type measurement which when directed at a heat source directly gives the temperature read out. Can be useful for measuring hot jobs in furnaces, surface temperatures etc. Rental charges per day: Rs. 2000/- for non contact and Rs. 4,000/- for contact instrument including technician

InstruSpices ANEMOMETER: This is used for the measurement of Air Velocity. Rental charges per day: Rs. 1000/- I nstrument including technician

InstruSpices SWING PSYCHROMETER: This is used for the measurement of Dry and Wet Bulb temperature Rental charges per day: Rs. 1000/- I nstrument including technician

InstruSpices LUX METER: Illumination levels are measured with a Lux meter. It consists of a photo cell which senses the light output, converts to electrical impulses which are calibrated as Lux. Rental charges per day: Rs. 1000/- I nstrument including technician

InstruSpices PITOT TUBE: Air velocity in ducts can be measured using a Pitot tube and inclined manometer for further calculation of flows. Rental charges per day: Rs. 1000/- I nstrument including technician

InstruSpices TEMPERATURE INDICATOR AND SENSORS: These are thermocouples which measures for example flue gas, hot air, hot water temperatures by insertion of probe into the stream. For surface temperature a leaf type probe is used with the same instrument. Rental charges per day: Rs. 1000/- I nstrument including technician

InstruSpices Anemometer +Swing Psychrometer + Temperature Sensor +Temperature Indicator Orsat Apparatus + Temperature Sensor + Temperature Indictator Rs.1250 per day