Fluoroscopic Image Quality Considerations

Slides:



Advertisements
Similar presentations
Formation Characteristics
Advertisements

Advanced Biomedical Imaging Lecture 4 Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
IMAGE FORMATION  Introduction  The Invisible and Visible Image  Image Characteristics.
Components of Radiographic Image Quality
Digital Radiography.
Resident Physics Lectures
Resident Physics Lectures
Fluoroscopy Equipment Operation
X-RAYS IN MOTION “Viewing dynamic studies of the human body”
Dr. Mustafa Zuhair Mahmoud Mr.Ali B Alhailiy بسم الله الرحمن الرحيم 1.
Fluoroscopy: Viewing Systems
Fluoroscopy Equipment
FLUOROSCOPY.
RAD 350 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion Invented by Thomas Edison.
Special Imaging Systems
F luoroscopy. 2 Fluoroscopy system 3 Different fluoroscopy systems  Remote control systems Not requiring the presence of medical specialists inside.
Fluoroscopy Intro to EQUIPMENT
Quality Control.
Image Quality Radiographic Resolution.
Fluoroscopy Equipment. Introduction Fluoro: is dynamic radiographic examination Fluoroscopy is primarily domain of the radiologist The role of radiographer.
Geometric Factors Focal Spot Object Film Object b a h c Film B A H C
Rad Tech 265 More Digital Imaging. Digital Fluoroscopy Radiation dose –Patient dose for DF is significantly less than conventional fluoro At 7.5 pulses/second.
Fluoroscopy Q&A Robert L. Metzger, Ph.D..
Exposure Factors or Prime Factors
Appendix H: Chapter 40: Fluoroscopy
What is being tested? (kVp, mA, mAs, mR?) What is the purpose of the HVL test? If an x-ray tube does not pass the HVL test what is done to correct the.
Radiographic Quality Visibility and Sharpness
Image Quality Q&A. RAPHEX Diagnostic Question 2001 D9: The imaging system which is best for visualizing small high contrast objects is: A. Computed tomography.
Fluoro Equipment Review RHB Fluoro Syllabus & Rad Prot
RAD 150 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic (motion)
RAD 354 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion.
Fluoroscopy. Real-time imaging Most general-purpose fluoroscopy systems use TV technology, operating at 30 frames/sec May be recorded (barium swallow.
Fluroscopy and II’s. Fluroscopy Taking real time x-ray images Requires very sensitive detector to limit the radiation needed Image Intensifier (II) is.
Sergeo Guilbaud School of Radiologic Sciences
FLUOROSCOPY & IMAGE INTENSIFICATION Sergeo Guilbaud, RT School of Radiologic Sciences.
RADIOGRAPHIC QUALITY S. Guilbaud, Education Director School of Radiologic Sciences.
Exposure Factors or Prime Factors
Chapters 21 & 22.
Resident Physics Lectures
Introduction to and History of Fluoroscopy Radiation Protection
Image quality and Performance Characteristics
Radiographic Contrast
Fluoroscopic Unit Thomas Edison 1896.
Fluoroscopy: Dynamic Imaging Systems
Resident Physics Lectures
Resident Physics Lectures
Pediatric Fluoroscopy
Fluoroscopy Dynamic Image Recording Systems
Fluoroscopic Brightness Control Systems
Fluoroscopic Image Intensifier Image production
Mobile Fluoroscopy Based on:
Mobile Fluoroscopy Based on:
Fluoroscopy Dynamic Image Recording Systems
Fluoroscopy: Viewing Systems
Introduction to and History of Fluoroscopy Radiation Protection
Pediatric Fluoroscopy
High Level (Boost) Fluoroscopy
Fluoroscopy Static Image Recording Systems
Fluoroscopy – Viewing Systems TV Monitors
Fluoroscopy – Viewing Systems Optical Mirrors TV Camera & TV Camera Tubes Charge Coupled Devices (CCD) Based on: Principles of Radiographic Imaging, 3rd.
Conducting the Fluoroscopic Examination & Basic Operational Procedures
Fluoroscopy – Viewing Systems TV Monitors
Fluoroscopy Static Image Recording Systems
Fluoroscopic Image Quality Considerations
Digital Fluoroscopy PPT created by: Jed Miles, BSRS, RT(R), CRT-CA
Fluoroscopic Image Intensifier Image Production
Fluoroscopy: Static Image Recording Systems
Mobile Fluoroscopy.
Brightness Control Systems
Presentation transcript:

Fluoroscopic Image Quality Considerations Based on: Principles of Radiographic Imaging, 4th Ed. By: R. Carlton & A. Adler Radiologic Science for Technologists, 8th Ed. By: S. Bushong Syllabus on Fluoroscopy Radiation Protection, 6th Rev. By: Radiologic Health Branch – Certification Unit PPT created by: Jed Miles, BSRS, RT(R), CRT-CA

Image Quality Because the “imaging chain” of a fluoroscopic system is a complex system there are more factors that affect image quality as compared to static radiography Factors to be considered are Contrast Resolution Distortion Quantum Mottle (Quantum noise or Scintillation)

Image Quality - Contrast Image intensified fluoroscopic contrast is affected by: Scattered ionizing radiation (same as static radiography) Penumbral light scatter from input and output screens Light scatter within the image intensification tube Transmitted incident primary beam striking the output phosphor Image contrast can be increased and/or controlled by electronically increasing the amplitude of the video signal

Image Quality – Contrast cont. All of these phenomena contribute to produce a background ‘fog’ that raises the base density of the virtual image Affects overall image contrast exactly as in static imaging. Increasing lowest density value decreases total visible contrast Overall effect is of reduced image contrast Also an inherent decrease in image contrast near outer or peripheral edges of fluoroscopic image Due to imperfect intensifier tube and electron beam geometry)

Image Quality – Resolution - MTF MTF explained: "A" is a set of patterns of dark and light bars. There are 4 sets of bars at increasing smaller spacing "B" is an “image” of what those bars might look like when imaged by a lens. The edges of the dark and light regions will be blurred - the closer the spacing, the more blurred they become. http://www.bobatkins.com/photography/technical/mtf/mtf1.html

Image Quality – Resolution Ability to resolve recorded detail will vary depending on geometrical factors (same as static radiography) Geometrical factors are of a different nature than in static radiography Minification gain Electrostatic focal point Input and output screen diameter Viewing system resolution (monitor resolution) OID Phosphor crystal size and thickness

Resolution Capabilities Zinc-cadmium input phosphor intensifier tubes 1- 2 lp/mm Cesium iodide (CsI) input phosphor image intensifiers ~ 4 lp/m Optical mirror systems that permit “indirect” viewing of the fluoro output screen: ~3 lp/mm Magnification or multifield image intensifiers ~ 6 lp/mm (in mag mode)

Image Quality – Size Distortion Caused by same factors that affect static radiography magnification – OID Multifield image intensifiers that produce magnification by changing the electrostatic focal point do not significantly affect actual size distortion Some size distortion is always present in the minified image Becomes more visible in a magnified image

Image Quality – Shape Distortion Shape distortion (pincushion) Primarily caused by shape of image intensification tube Significant over 8-10% of the image area Inherent edge distortion at output screen even with concave input screen Electron stream focusing not uniform across entire field of image intensifier Electrons at outer edges of image flare outward as they are electrostatically focused Due to repulsion of like charges Partially due to divergence of primary x-ray beam

Image Quality - Vignetting Center of output screen brighter than periphery due to unequal magnification of the electron stream causing unequal illumination at output phosphor Resolution is better in center of image Distortion minimized at center of image Contrast improved at center of image

Image Quality - Veiling Glare Veiling glare is mainly the consequence of light scatter in the output window of the image intensifier Scattered light, like scattered radiation, adds to the background signal and thus reduces the contrast of the image Measuring the ‘contrast ratio’ of an image intensifier is a good method to quantify the magnitude of this problem

Image Quality Quantum Mottle, Quantum Noise, Scintillation Blotchy or grainy appearance caused by insufficient radiation to create a uniform image Static radiography: mA and time as mAs controls quantity of photons creating density on image receptor Fluoroscopy: factor of time limited by length of time human eye can accumulate or integrate enough visible light photons from the fluoro imaging chain to be perceived This time period is 0.2 seconds Fluoro mA must be high enough to avoid excessive mottle as perceived by the observer

Quantum Mottle, Quantum Noise, Scintillation Inherently present in any electronic video system as ‘video noise’ or ‘electronic noise’ Creates a special problem as fluoro units are operated with the minimum mA (dose) possible to activate the fluoro screen mA too low causes “excessive” quantum mottle / scintillation mA increased enough to permit image signal to be visualized A low SNR would produce an image where the "signal" and noise are more comparable and thus harder to discern from one another The image above has a sufficiently high SNR to clearly separate the image information from background noise http://www.cambridgeincolour.com/tutorials/noise.htm

Image Quality – Quantum Mottle – cont/ Factors affecting quantum mottle include: Initial radiation output Beam attenuation by subject matter Conversion efficiency of input screen Total brightness gain Viewing system (direct, monitor, film, etc) Distance of observer from viewing system (inverse square law of light) Increasing efficiency of any of these will reduce quantum mottle Common solution is to increase fluoro tube mA Results in an increased patient dose rate

What’s Next? Please close this PowerPoint presentation, and then click Topic 4 to continue