(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)

Slides:



Advertisements
Similar presentations
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Advertisements

Bonding and Grounding What? Why? How?
Electrical Safety.
CHAPTER 45 Engine Lubrication.
A PPARATUS G AS G ROUPS, T EMPERATURE C LASS AND T YPES OF E XPLOSION P ROTECTION (Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
 Without reference, identify principles relating to Fixed Radiological X-RAY PM with at least 70 percent accuracy.
Inspection & Preventive maintenance of breakers
Safely Using Drill Collar Clamps
Today’s Meeting There are approximately 25 people killed by electricity per year in Australia (average for the last 7 years), 700 people are hospitalised.
CONTROL OF HAZARDOUS ENERGY “LOCKOUT/TAGOUT” (LOTO)
(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
Tire Servicing Program. Agenda WorkSafeBC Requirements Definitions Responsibilities General safety.
MAIN ELECTRICAL SURVEY ITEMS, GENERATORS AND GOVERNORS,, CIRCUIT BREAKERS, SWITCHBOARDS AND FITTINGS (Adapted from:D.T. Hall:Practical Marine Electrical.
Proper Use of Extension Cords Proper Use and Electrical Hazard Awareness for Extension Cord Users Module 2.
Fire safety is an important business. You need to take proper precaution in order to prevent a fire. Yes, fire may be inevitable but if prepared, you can.
By Danielle.  The provision and use of work equipment regulations was first introduced in 1992 but was replaced by a more update version in The.
Controlling Hazardous Energy
(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
Session 5 Lesson 5 Why? To protect: People Property Against: Electrical Hazard Mechanical Hazard For: Inspections Repairs Maintenance.
Step 1 Park vehicle on a level surface then engage the parking brake and turn off engine. If you cannot comfortably get under the car, raise the front.
EKAS Disconnect & Reconnect UEE31307 Certificate III in Refrigeration and Air Conditioning Stage 2A Units: UEENEEPOO1B Chris Hungerford Sunday,
4.1.5 Student Book © 2004 Propane Education & Research CouncilPage Determining the Proper Corrosion Protection Systems for Underground ASME Tanks.
Student Book © 2004 Propane Education & Research CouncilPage Applying Protective Coatings to Storage Containers ASME tanks require proper.
Safety Induction to the Lift & Escalator Industry Part 3 - Tools & Equipment Part 3 - Tools & Equipment.
SITE SAFETY HAZARDS AND PROCEDURES. ELECTRICAL HAZARDS  Electricity is a serious workplace hazard.  Employees can be exposed to dangers such as : 
Health and Safety. The Health and Safety at Work Act 1974 An Act to make further provision for securing the health, safety and welfare of persons at work,
Chapter One Electrical Design and Component Basics.
Electrical Safety.
Safety Induction to the Lift & Escalator Industry Part 6a - Working Safely - General Part 6a - Working Safely - General.
Part 3.3 Production Safety. Objectives After reading the chapter and reviewing the materials presented the students will be able to: Understand safety.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
Preventing Slips & Trips at Work
Basic Awareness Training for all Staff
Chapter 7 Safety. Introduction This chapter covers the following topics: Dangers of electricity Preventive measures Electrostatic discharge Safety practices.
E8 / PPA Solar PV Design Implementation O&M Marshall Islands March 31-April 11, Preventive Maintenance.
Proper Use of Extension Cords
Safety on Call ELECTRICAL SAFETY. Safety on Call YOU WILL LEARN ABOUT Hazards of Electricity Isolating Circuits Testing Circuits Work on Energized Equipment.
Horticulture II - Landscape UNIT C LANDSCAPE INSTALLATION AND MAINTENANCE.
06/01/20161 Benny Hoff TÜV NORD Sweden AB AFS 2002:1 Use of pressure equipment.
MNM Fatal /14 Fall of Material Accident Fall of Material Accident August 12, 2010 (Nevada) August 12, 2010 (Nevada) Underground Gold Mine Underground.
What is a safe work permit? A safe work permit is a written record that authorizes specific work, at a specific work location, for a specific.
Unit A 6-4 Mechanical Systems and Technology. Problem Area 6 Agricultural Power Systems.
Timing (minutes) Learning ObjectiveMain tasks / ProcessResources / tools 5TitleStandard Operating Procedures for Power Press Machine Slide 1 5Index 
All About Workplace Electrical Safety
Hot Work Permit Osan AB Fire Emergency Services.
SCOTTISH BORDERS SAFETY FORUM WORKING SAFELY WITH WORK EQUIPMENT Compiled by Donald A Mackay Mainetti UK Ltd.
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
Task Carry out routine maintenance of equipment and machinery.
Level 1 Diploma in Electrical Installation © 2014 City and Guilds of London Institute. All rights reserved. 1 of 7 PowerPoint presentation Supporting information.
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
Manufacturing the Safe Product
EV DOMESTIC CHARGING UNIT
EV DOMESTIC CHARGING UNIT
DESCRIPTION AND GUIDE TO OPERATIONS
Clinical engineering Lecture (7).
"This document can not be used without Samsung's authorization"
Monitor Operations Procedures To Safely Control Work
Testing and tagging.
Chapter 31 Battery Systems.
Crane safety and inspections
Hazardous Areas & Hazards of Electricity
Crane safety and inspections
From AS :   Part 4— Commissioning, operation and asset management
Hand & Power Tools, Subpart I
Control of Hazardous Energy
Lockout/tagout Refresher Training
Crane safety and inspections
Topic 1: Cables and conductors
Crane safety and inspections
Electrical components and systems
Presentation transcript:

(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)

When a manufacturer produces an item of explosion protected equipment, it must be tested and inspected to ensure that it complies with the required standards relating to that type of protection.

All electrical apparatus and associated circuits are required to be tested periodically in accordance with a definite testing routine with recorded test results.

Insulation resistance, earth loop resistance and earth continuity resistance tests are required to be made, the last two in relation to the setting or rating of the protective devices associated with the apparatus and its circuitry.

It is important that insulation resistance tests are NOT made in such a way that the safety devices and insulation used in intrinsically safe apparatus and circuits are damaged by excess test voltages.

No apparatus should be opened in a danger area until it has been made dead and effective measures (e.g. locking-off the isolating switch) have been taken to prevent its being made live again inadvertently.

Where, for the purpose of electrical testing, it is necessary to restore the power supply before the apparatus is reassembled, tests should be made using a suitable gas detector and continued during the operation to ensure that the combustible does not approach the explosive limit. Unless the hazardous area can be made gas-free or otherwise safe, or the electrical equipment is removed from the area, then insulation resistance testing should be carried out using a 500 V d.c. tester of certified intrinsically safe (Exi) design.

The testing and maintenance of flameprooj or intrinsically safe equipment should be entrusted only to competent persons who have received instruction in the special techniques involved. The body material of instruments and tools required for maintenance purposes should be designed so that they will not make a hot spark when dropped.

The energy output of all intrinsically safe instruments should be so small that they do not produce hot sparks. An insulation tester has a drooping characteristic to prevent high currents and may be intrinsically safe when applied to circuits of small inductance or capacitance but a risk may arise when such energy-storing properties of a circuit have an appreciable value.

Where such instruments are used the ( test leads should be firmly connected throughout and on completion of the test they should not be detached until the circuit has been discharged through the testing instrument (leave the tester for one minute after test is finished).

The previous sections covering zoning, gas grouping, temperature classification and the various types of protection methods show that the design of electrical equipment for hazardous areas is very special.

Maintenance of such apparatus must not, in any way, cause its operation to be less safe than in its original certified state. This most important point means that the maintenance must be carried out by a competent person. Temporary lash-ups, refitting with wrong sized components (e.g. lamps), failing to employ the correct number of cover bolts etc., is absolutely forbidden.

The inspection and maintenance of Exd (flameproof) enclosures for luminaires, switches, junction boxes, push-buttons, etc., requires meticulous care. The following example gives a guide to the inspection and maintenance points as applied to a flameproof luminaire:

This will reduce the enclosure strength. To ascertain the extent of corrosion, remove dirt, loose paint and surface corrosion with a wire brush. If only the paintwork is deteriorating, the enclosure should be repainted to prevent further corrosion.

Make sure that there are no missing bolts. This is particularly important on flameproof luminaires because a missing bolt will invalidate the certification. Replacement bolts must be of equivalent strength as originals (usually high tensile steel).

Ensure all mountings are secure. Corrosion and vibration are severe on ships and can cause premature failure.

Examine the flamepath for signs of corrosion or pitting. If the flamepath needs cleaning, this should be done with a non- metallic scraper and/or a suitable non- corrosive cleaning fluid.

Examine the cement used around lamp- glass assemblies both inside and outside. If the cement is eroded, softened or damaged in any way, advice should be sought from the manufacturer regarding repair. If deterioration of the cement has occurred, a complete new lampglass assembly should be fitted.

Check lampglass; if cracked or broken a complete new lampglass assembly should be fitted. Clean the lampglass.

When re-assembling an Exd enclosure you must ensure that the following points are covered: Lightly grease all flamepaths and threaded components with an approved form of non- setting silicone grease. Care must be taken to ensure that blind tapped holes are free from accumulated dirt or excessive grease which can prevent the correct closure of flamepaths, or cause damage to the tapped components. Fit new lamp of the correct rating.

Ensure bolts are not over-tightened as this can distort flamepaths, cause excessive stress on lampglasses or distort weather proofing gaskets, if fitted, allowing the ingress of liquids and dusts. Check the luminaire is installed in accordance with the requirements of the installation, particularly the classification of the area if it is hazardous and that the correct rating of lamp is fitted. Remove any build-up of dust on the luminaire, this can cause overheat­ing as well as acting as a corrosive agent.

Before attempting any maintenance work on Exd equipment check for any particular inspection and overhaul instructions given by the manufacturer.