BACKGROUND Ventricular assist devices (VADs) are a proven therapy as bridge-to-cardiac transplantation in Class IIIB and Class IV heart failure patients.

Slides:



Advertisements
Similar presentations
Figure 2 Projected Total Costs During Bridging Period LOWER COSTS ASSOCIATED WITH HOME DISCHARGE OF BRIDGE-TO-TRANSPLANT PATIENTS USING THE TLC-II PORTABLE.
Advertisements

Managing the LVAD patient in Cardiac Rehabilitation
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
Community Preparation for Caring for Mechanical Circulatory Device Patients University of Wisconsin Hospital And Clinics Ventricular Assist Device Program.
An Overview of Ventricular Assist Devices Pre Hospital Management
Left Ventricular Assist Devices “LVAD”
Pre-Hospital Care of the Mechanical Circulatory Support Device Patient
LUCAS 2 Compression Device
Power Module – Setup Before using the Power Module (PM) to power the HeartMate II or XVE LVAS and optional Display Module or System Monitor, prepare the.
HS-30 Hydrostatic Pressure Sensor Presented By Peter Ward Hydrological Services Pty Ltd.
DP-IR Detecto-Pak Infrared
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
AUTOMATED EXTERNAL DEFIBRILLATION
HeartMate® GoGear™ System Components Training
1 CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a physician. Refer to the “Instructions For Use” for complete Indications.
1 CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a physician. Refer to the “Instructions For Use” for complete Indications.
BACKGROUND Ventricular assist devices (VADs) are a proven therapy as bridge-to-cardiac transplantation in Class IIIB and Class IV heart failure patients.
Syringe Pumps. Topics  Diagrams  Principles of Operation  Applications  Safety  Operation  Preventive Maintenance  Common Failure Modes  Troubleshooting.
© 2008 Masimo Corporation Includes a review on Carbon Monoxide Poisoning For Emergency Responders V.8 1 May 2011 Monitoring CO Poisoning with the Rad-57.
Clinical Assessment of Pulsatile and Non-Pulsaltile VADs Diana Joseph RN, BSN, CCTC VAD/Heart Transplant Coordinator OSF St. Francis Medical Center Peoria,
1 LIFECARE PLV-100 by Bryce Younger. 2 Classification ► Electrically powered  microprocessor controlled ► Volume-control, time cycled ► Rotary drive.
EMS Management of the SynCardia Temporary Total Artificial Heart (TAH-t) Patient Clinical-xxx Rev001.
Chapter 33 Charging System Fundamentals.
Topics Zoll LifeVest  What it is  Who it treats  How does EMS handle these patients?
Equipoise Does Not Exist for REVIVE IT Andrew Boyle, MD Heart and Vascular Center Director, Florida Chairman of Cardiology Medical Director of Heart Failure,
VAD Resource Team University of Washington Medical Center
1 Batteries & Battery Clips – Setup for Operation Follow these steps to prepare for battery-powered operation: 1.Place two battery clips, two charged batteries.
Charging System Service
Community Preparation for Caring for Mechanical Circulatory Device Patients University of Wisconsin Hospital And Clinics Ventricular Assist Device Program.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only Publisher The Goodheart-Willcox Co., Inc. Tinley Park, Illinois.
Mechanical Circulatory Support for Advanced Heart Failure Speakers: Lynne A Benish, ACNP-BC Mechanical Assist Device Nurse Practitioner, Cardiac Surgery.
Ventricular Assist Devices Brian Schwartz, CCP February 25, 2003.
Advances In LVAD Patient Management
Introduction to Ventricular Assist Device (VAD)
Ventricular Assist Devices
9/5/20151 Ventricular Assist Device (VAD) Patients in the Community Liz Amerman, RN, BSN IU Health Methodist VAD Program Manager April 18, 2012.
Silver Cross EMSS March 2013 EMD CE LVAD.
IABP, VAD, ICD & Pacemaker Therapies Diane E. White RN CCRN PhD.
Ventricular Assist Device: An Advanced Surgical Intervention for the Treatment of End Stage Heart Failure Laura Coyle, MSN, ACNP-BC VAD Coordinator Advocate.
Transition to Next Level of Care Management of Patient with Ventricular Assist Device Hospital Home Transition.
Advances in LVAD Design
Erik Simpanen September 27 th, 2011 BME 281. Heart Disease  A generic term for referring to numerous different forms of sicknesses that effect the heart.
Design of Ventricular Assist Device Basic Components of VAD 1. Blood pump 2. Controller 3. Power source Two Categories of VAD’s Pump 1. Pulsatile flow.
Smitty’s Speed Drills 2008 Code Drills Health Care Facilities (C) Copyright 2008 Ted "Smitty" Smith1.
Community Preparation for Caring for Mechanical Circulatory Device Patients University of Wisconsin Hospital And Clinics Ventricular Assist Device Program.
Top Ten things you need to know… About VAD’s Kim Byrum Chappell Mechanical Assist Coordinator.
Nick Dominesey Matthew Myers Michael Edson Ellie Sanford Chris Smith Jason Inman.
Ventricular Assist Devices A Ventricular assist device, or VAD, is a mechanical circulatory device that is used to partially or completely replace the.
Management of Heart Disease in Pregnancy.  It is estimated that 1% to 3% of women either have cardiac disease entering pregnancy or are diagnosed with.
Pediatric Mechanical Circulatory Support (MCS) Ivan Wilmot, MD Heart Failure, Transplant, MCS Assistant Professor The Heart Institute Cincinnati Children’s.
BME 301 Lecture Nineteen. Progression of Heart Disease High Blood Pressure High Cholesterol Levels Atherosclerosis Ischemia Heart Attack Heart Failure.
Ventricular Assist Device: Intervals for dressing changes By. Megan Giska.
Mechanical Circulatory Support Cardiogenic Shock Post AMI
Advanced Therapies Lee R. Goldberg, MD, MPH Medical Director, Heart Failure and Cardiac Transplant Program University of Pennsylvania.
BME 301 Lecture Nineteen. Progression of Heart Disease High Blood Pressure High Cholesterol Levels Atherosclerosis Ischemia Heart Attack Heart Failure.
Date of download: 7/9/2016 Copyright © The American College of Cardiology. All rights reserved. From: Results of the Destination Therapy Post-Food and.
BME 312 BIOMEDICAL INSTRUMENTATION II LECTURER: ALİ IŞIN LECTURE NOTE 2 BLOOD PUMPS BME 312-BMI II-L2-ALİ IŞIN 2015 FACULTY OF ENGINEERING DEPARTMENT OF.
10/11/2011 Ashton Pepple Kyler Sanders
Ventricular Assist Device
Fifth INTERMACS annual report: Risk factor analysis from more than 6,000 mechanical circulatory support patients  James K. Kirklin, MD, David C. Naftel,
University of Wisconsin Hospital And Clinics
LIFEPAK® 1000 Defibrillator Orientation Guide
Henry Ford Health System
Mechanical Circulatory Support Devices HOSEIN PASANDI.
Durable Mechanical Circulatory Support in Advanced Heart Failure
Mechanical circulatory assist device development at the Texas Heart Institute: A personal perspective  O.H. Frazier, MD  The Journal of Thoracic and Cardiovascular.
Heart Mate Pump 2 LVAD Patient Stories
2008 Code Drills Health Care Facilities
Heartware HVAD Ventricular Assist System
Presentation transcript:

HeartMate II Left Ventricular Assist Device (LVAD) Courtesy University of Washington Medical Center

BACKGROUND Ventricular assist devices (VADs) are a proven therapy as bridge-to-cardiac transplantation in Class IIIB and Class IV heart failure patients The dramatic increase in the use of VADs has been unavoidable for those patients suffering end-stage heart failure due to the consistent shortage of donor organs As mean support duration for VADs increases, more VAD patients will be living in the community HeartMate LVAD is approved as Destination Therapy (DT)

HM II CANDIDATES FDA Approved 1.20.10 FDA Approved 4.21.08 Bridge-to-Transplant (BTT) FDA Approved 1.20.10 Destination Therapy (DT)

HM II Cored into LV Outflow to aorta Percutaneous tube System Controller Batteries

Anatomic Placement

FUNCTION & CAPABILITY Axial (continuous) flow: ?NO PULSE/ ?BP One moving part: Rotor Small 400 gm 125 cc 60% smaller than HM I (XVE) Quiet Flows: 3 – 10 lpm Anticoagulation required

ADVANTAGES Size: Potential BSA of .8 m2 Only one moving part Blood lubricated bearings Designed for long term support Lower infection rates (smaller perc tube)

Pump Housing Rotor

PUMP ROTOR and STATORS BLOOD FLOW Inflow Bearings Inflow Stator Outflw Stator Outflow Bearins Rotor

SYSTEM CONTROLLER Controller + Back-up Controller

FACE OF SYSTEM CONTROLLER

POWER MODULE Supplies main power to LVAD Provides 30 minutes of backup power Repeats alarms generated by the System Controller Serves as the electrical interface between the System Controller and the Display Module

BATTERY CHARGER

BATTERIES 14v Li-Ion 6 – 10 hours of support *Patients report up to 15 hrs of battery power Up to 4 hour recharge for fully discharged battery 3 years or 360 charges

DISPLAY MODULE Pump Mode Pump Speed (rpm) Pulse Index Fixed Power Saver Pump Speed (rpm) Pulse Index Estimated Flow (lpm) Too low “---” Too high “+++” Power (watts) Alarm Conditions Highest priority displayed AUTO MODE: only with Thoratec engineer

EMERGENCY POWER PACK (EPP) Single use battery pack in a plastic carrying case with a shoulder strap Provides battery power in the event of extended power outage Approximately 12 hours of support Must be replaced if used for a period exceeding three hours

BATTERY ALARMS ADVISORY ALARMS HAZARD ALARM

BATTERY ALARMS BATTERY < 15 minutes of power BEEP Q SEC BATTERY < 5 minutes of power STEADY TONE Defaults to ‘Power Saver Mode’ Pump defaults to Fixed Rate Mode of 8000 rpm, or fixed speed setpoint if lower System will return to set speed once adequate power is restored ACTION Replace batteries or switch to alternate power source

SYSTEM DRIVER CELL LOW VOLTAGE SYSTEM CONTROLLER CELL LOW VOLTAGE Yellow cell symbol Beep every 4 seconds ACTION Replace cell battery and perform System Controller self test

POWER CABLE DISCONNECTED and FLASHING Flashing green power symbol & battery power bars Beep every second ACTION Check cable connections to power source Check power leads for damage, replace if necessary

LOW FLOW; NO OPERATION or INCORRECT OPERATION LOW FLOW < 2.5 lpm Pump not operating or not operating correctly Decreased preload (right heart failure, tamponade, hypovolemia, bleeding, etc) Obstruction of pump inflow or outflow Systemic hypertension ACTION Assess patient Monitor

DRIVELINE DISCONNECTED FROM CONTROLLER Check connections ACTION Reconnect driveline to controller

STEADY TONE and NO SYMBOL NO POWER TO PUMP ACTION Check system driver connections to pump Check system driver power connections to power source If persist, seek additional help immediately

CPR SHOULD NOT BE PERFORMED ON HEARTMATE LVAD PATIENTS UNLESS DIRECTED

VT or VF STABLE UNSTABLE Patient may “feel funny” “light headed” or “different” Pump speeds and flows are normal, low normal, or very low Consider cardioversion after consultation with Mechanical Assist Device Coordinator UNSTABLE Patient unresponsive Treat as unstable VT/VF

LVAD PATIENT TRANSPORT Transport to assigned facility Spare batteries, PBU and the display module should be brought to the hospital with the patient PBU weighs 29 pounds without batteries All modes of emergency transportation are acceptable Aviation electronics will NOT interfere with LVAD and visa versa

Thank You !!!