2/22/2019 Pump Design Dick Hawrelak Presented to UWO CBE 497 10 Oct 00.

Slides:



Advertisements
Similar presentations
Where We Go Wrong In Line Sizing Dick Hawrelak Presented to ES317Y in 1999 at UWO.
Advertisements

SAMPLE SLIDES OF THE 1-DAY SEMINAR FOR PUMP USERS
Step 1: Set the desired flow rate for each pipe. Step 2: Click on the stream which you wish to size the pipe. Select Sizing from the menu, then select.
Pumps, Compressors, Fans, Ejectors and Expanders
Rotating Equipment PUMPS.
Pump Basics. Centrifugal Pumps From the Center of a Circle RADIAL DIRECTION To the Outside of a Circle A machine for moving fluid by accelerating the.
The Centrifugal Pump.
Vapor-Liquid Separator Design
Lesson 26 CENTRIFUGAL PUMPS
Piping Systems.
Core Ag Engineering Principles – Session 1
Week 1 Unit Conversions Mass and Volume Flow Ideal Gas Newtonian Fluids, Reynolds No. Week 2 Pressure Loss in Pipe Flow Pressure Loss Examples Flow Measurement.
Pumps.
Where We Go Wrong In Pump Design Dick Hawrelak Presented to ES317Y in 1999 at UWO.
Valves In Industry (Part 3).
Conservation of Mass, Flow Rates
P&ID Design and Equipment Selection
Water piping design.
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
1 Pumping Learning Outcomes Upon completion of this training one should be able to: Know what are the key pump components and how they impact pump.
So Far: Mass and Volume Flow Rates Reynolds No., Laminar/Turbulent Pressure Drop in Pipes Flow Measurement, Valves Total Head, Pump Power, NPSH This Week:
Pump Design & Selection n Dick Hawrelak n Presented to UWO CBE 497 n 16 Oct 01.
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
Things to grab for this session (in priority order)  Pencil  Henderson, Perry, and Young text (Principles of Process Engineering)  Calculator  Eraser.
Things to grab for this session (in priority order)  Pencil  Henderson, Perry, and Young text (Principles of Process Engineering)  Calculator  Eraser.
Metso - Slurry Pumping.
Valves In Industry (Part 3)
Process Design CEN 574 Spring 2004
SUBJECT CODE NAME OF SUBJECT TOPIC :::::: FLUID POWER ENGINEERING CENTRIFUGAL PUMP Parul Institute of Engineering & Technology.
So Far: Mass and Volume Flow Rates Reynolds No., Laminar/Turbulent Pressure Drop in Pipes Flow Measurement, Valves Total Head, Pump Power, NPSH This Week:
Urban Storm Drain Design: Multiple Pumps. Multiple Pumps The HDM and FHWA recommend more than one pump Redundancy Flexibility Ability to manage flows.
A Primer on Pumps Shenandoah Valley December 2, 2015.
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
Introduction to Energy Management
CE 3372 Water Systems Design
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Design of Heat Exchangers
Turbomachines are fluid machines that are based on a spinning rotor
Things to grab for this session (in priority order)  Pencil  Henderson, Perry, and Young text (Principles of Process Engineering)  Calculator  Eraser.
1 ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 6 : PUMPS.
FLUID FLOW FOR CHEMICAL ENGINEERING Dr Mohd Azmier Ahmad Tel: +60 (4) EKC 212 CHAPTER 8 (Part 5) TRANSPORTATION SYSTEM.
CENTRIFUGAL PUMPS:- DESIGN & PERFORMANCE Ir. N. Jayaseelan 2012.
Chapter 10: Flows, Pumps, and Piping Design
Fluid Mechanics for Chemical Engineers Arif Hussain (Lecturer)
Chapter 6 technology institute of HAVC from usst INDUSTRIAL VENTILATION TUTORIAL 王丽慧.
Power – Energy Relationships
CHEMCAD Seminar Transport and Storage John Edwards, P&I Design Ltd
System One Pumps S1-200 Centrifugal Hydraulics
CENTIFUGAL PUMP OPERATION
Week 1 Unit Conversions Conservation of Mass Ideal Gas
First Law of Thermodynamics applied to Flow processes
Continental AG Manufacturing Facility
Deptt. of Irrigation and Drainage Engineering, Dr. PDKV, Akola
Chapter 16 A: PUMPS AND SYSTEM EFFECTS
CENTRIFUGAL PUMP TROUBLESHOOTING
Pumps Outline: Where are pumps used
Process Equipment Design and Heuristics - Pumps
ME444 ENGINEERING PIPING SYSTEM DESIGN
Pumps and Lift Stations
Find: Q gal min 1,600 1,800 2,000 2,200 Δh pipe entrance fresh water h
System One Pumps Selecting Centrifugal Pumps S1-201
Review from Lecture 1: Pumps
SIMILARITY AND DIMENSIONLESS GROUPS
Review from Lecture 1: Pumps
Review from Lecture 1: Pumps
Performance Curves Dr. C. L. Jones Biosystems and Ag. Engineering.
4.6 Cavitation Since NPSHav. is the absolute pressure available less the vapor pressure of the liquid, the NPSHav. should always be greater than the NPSHreq.
Pumps and pumping station
Presented By: Vinod Dahiya Lecturer Mechanical Engg. RGGP Narwana.
Hydraulic Pump Power Power = rate of conversion of energy.
Presentation transcript:

2/22/2019 Pump Design Dick Hawrelak Presented to UWO CBE 497 10 Oct 00

Good Design References Flow of Fluid Through Valves and Fittings by Crane. Technical Paper No. 410-C. Centrifugal Pumps and System Hydraulics, Chem Eng’g, 4 Oct 82, p-84, by Karassik. Chem Eng Handbook, Perry 6, Sections 5 and 6 Primer software by Durco http://www.durcopump.com PumpSel 6.2™ (rev .07) by Durco http://www.durcopump.com

Pump Design Stages Phase 2 – Process alternatives & optimization. Phase 3 – P&IDs, preliminary layout, approx design, specification, pre-selection, cost estimate. Phase 4 – detailed design. Final layout – check piping & elevations. Final detailed hydraulic design & selection. Suitability (NPSH, SSS, Re-circulation). Final cost estimate.

Excel Pump Design Program Plant Design Programs on CD-ROM Quick Pump Design V1.3 Contains Following Features Line Sizing Control Valve Sizing Check Valve Sizing Orifice Plate Sizing NPSH, NS, SSS, HP calculations System Head Curve Limited Pump Selection Used along with Durco’s PUMPSEL and PRIMER

Draw Sketch of Pump System Collect physical property data (density, viscosity, vapor pressure). Show line details, size, schedule or wall thk, check valves, control valves, block valves, reducers/expanders (may have to take a WAG). Show origin (min.) and destination pressures (max.). Show origin and destination elevations for static head. Combine services where practical & economical.

Typical Pump Sketch

Size Suction and Discharge Lines Break lines into sizable sections. There may be different sizes in any one branch. Eg 4”, 6” and 8” sections. Estimate the number of elbows, block valves, fittings, etc. (WAG in Ph 2). Expand line sizing routine for record keeping. This will simplify phase 4 checking.

Line Size Equations Re No. = 6.31 ( W ) / ( d ) / ( cP ) Darcy friction factor f = 4 ( f Fanning ) f Darcy by “all-in-one” Chen Equation DP100 = 0.000336 ( f )( W )^2 / ( DL ) / ( d )^5 Max Dp100 usually limited to 1.0 psi per 100 ft. K = ( f ) ( L / D ) for pipe K = ( f Turb ) ( L / D ) for valves and fittings K total = K pipe + K valves & fittings DP = 2.8E-07 ( K total )( W )^2 / ( DL ) / ( d )^4 Abs roughness e = 0.00015 for clean pipe, ft. Abs roughness e = 0.0004 for dirty pipe, ft.

Size Check Valves in Each Discharge Line Branch Line sizing program built-into Pump pgm. Check pipe spec for type of check valve. Check minimum line velocity to keep ChV in open position. Prolonged operation at reduced rates may cause ChV chatter and damage to ChV. Operation with damaged ChV is extremely hazardous.

Typical Check Valve Equation For a Swing Check Valve (see Crane, page A-27) K = 100 ( f Turb ) for pressure drop Minimum Velocity, fps = 35 / ( DL )

Size Orifice Plates in Each Branch See Line sizing routine. Orifice Plate pressure drop usually in three ranges. Typically 0.5, 1.0 or 2.0 psi

Typical Orifice Equation Beta = d1 / d2 should be in range 0.2 to 0.7 d1 = orifice dia., d2 = pipe dia., inches Re No. based on d2, the pipe diameter W = 1891 ( d1 )^2 ( C ) (( DP )( DL))^0.5 C = Flow Coefficient for square edged orifices (see Crane, page A-20) C = Function of Re No. and Beta ratio C should be in range 0.6 to 0.8

Control Valves Select each branch with control valves and use line size routine to size control valves assuming Fisher Equal Percentage type valves. Poor CV selection – no control, pump running on by-pass…may need two control valves. If too large DP taken across control valve, it may be better to trim impeller, save CV wear & energy. Pump program should use CV in controlling line. DP CV / (DP CV + DP fric) = approx 0.1 to 0.3. Default DP control valve = 10 psi.

Typical Control Valve Equations Cv = ( USGPM )( SG / DP )^0.5 Cv = Liquid Sizing Coefficient Typical control valve is an equal percentage type valve. Cv depends on valve size, % valve opening, and flow.

Blocked-in Operation. Determine features required for blocked-in operation. Low flow shut-down. High temperature shut-down. Recycle plus cooling. Pumps can explode in a short period of time if left running while blocked-in and no high temperature shut-down is provided. Pump explodes, pieces rocket 275m, hits truck, kills driver. Pump leaks under high pressure, liquid catches fire and destroys plant.

Suction Conditions Determine NPSH available. NPSH = SP – VP + HL – DP friction all in ft of liq. Boiling liquids, SP = VP. Raise height or reduce DP. Poor NPSH causes pump cavitation, high vibration & ultimately pump failure (hazard). Pump fails to perform as designed without NPSH available greater than NPSH required. Typically, NPSH avail 12 ft. vs 10 ft. req’d. Pump Vendor will tell you NPSH required based on pumps selection.

System Head Curve Determine Controlling Branch – I.e the one that requires the maximum differential head. Determine the system curve for all items except the control valve. For Dp at reduced USGPM, assume DP is proportional to the square of the flow. Include static head.

Pump Selection Hundreds of pumps to select from. Which selection is best? Which RPM to use? What HP size & type of motor to select, explosion proof, TEFC? Download Durco PUMPSEL and PRIMER on internet (program is free). http://www.durcopump.com

Durco PUMSEL Program Input From Quick Pump Design V1.3 enter: Design USGPM System head, in ft. Specific Gravity Pumping temp, Deg F Viscosity in Centipoise NPSH available in ft. 3 points from system curve.

PUMPSEL Output Selects all available pumps Gives Impeller sizes Gives HP and NPSH Required Gives a cost estimate (PRIMER) Gives options for types of pumps Gives all kinds of help on all features. PUMPSEL is a must for any design group. Program also available from Gould.

Typical Pump Head Curves

Selected Pump

Suction Specific Speed, SSS SSS is an Index number descriptive of the suction charateristics of a pump impeller. SSS = (rpm)(Q @ BEP)^0.5 / (NPSH @ BEP)^0.75 Pumps operating at SSS greater than 11,000 had a high failure frequency (hazard). Low capacity operation causes inlet recirculation, impeller erosion, shaft deflections, bearing failures and seal problems which lead to leakage. Pump program predicts recirculation as % of SSS.

Dissolved Gases Absorbed gas follows Henry’s Law xa = (pp / Pt) / H. Dissolved gases are like entrained bubbles. Residence time in suction vessel may be too short. Dissolved gases causes problems similar to NPSH cavitation. Prevent vapor entrainment with vortex breakers.

Material Transfer Need multiple checks on quantity of material transferred to storage. Weigh scales, level checks, mass = (flow rate)(time) on computer. Time control EBVs to minimize Water Hammer problems.

Excess Flow Protection 2/22/2019 Excess Flow Protection Pumps cannot be allowed to run out on the impeller curve, may burnout motor if motor not selected for runout. May need excess flow protection.