HEAT LOSS & HEAT GAIN HEAT FLOW. Heat flows from high temperature to low temperature There are 3 types/methods of heat flow/transfer: 1.Conduction- through.

Slides:



Advertisements
Similar presentations
Environmental Controls I/IG
Advertisements

Formulas.
Heating Losses- Infiltration and Ventilation
J.B. Speed School of Engineering University of Louisville KEEPS Energy Management Toolkit Step 2: Assess Performance & Opportunities Toolkit 2J: Building.
Energy Efficient Heating Ventilating and Air Conditioning.
EarthCraft: Insulating Strategies Energy Efficient Insulation Systems by Church Hill Homes.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – December 2012 eere.energy.gov Calculating Envelope Energy Loss WEATHERIZATION ENERGY AUDITOR.
Energy Savings Impacts of the Advanced Energy Design Guide: Small Office Buildings Bing Liu, P.E. Research Engineer Pacific Northwest National Laboratory.
Doing without and more with less
Heating Systems Forced Air Systems.
Environmental Controls I/IG
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
The House as a System 1. Systems in a Home Electrical Plumbing Comfort Control (HVAC) Structural Moisture Control Air Infiltration Thermal Insulation.
The Three Tiered Philosophy
1 ISAT Module III: Building Energy Efficiency Topic 6:Stead-State Building Loads z Fabric Loss z Ventilation Loss z Environmental Temperature z Steady-State.
The House as a System 1. Air Temperature and Water Vapor.
Agricultural Structures: Insulation and Heat Flow
Conduction Cooling Loads
Heat Loss & Gain Calculations 1. How Heat Moves in Homes Conduction is the transfer of heat through solid objects, such as the ceilings, walls, and floors.
Heat Loss HVAC CNST 305 Environmental Systems 1 Dr. Berryman.
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
Greenhouse Heating Requirements Greenhouse Management.
Chapter 4: Air Leakage Control: Materials and Techniques
Walls. Apply knowledge of thermal mass and insulation with passive design strategies to reduce the energy needed by active systems.
 On average, home heating uses more energy than any other system in a home  About 45% of total energy use  More than half of homes use natural gas.
Adriana Galue Wolfgang Custom Finishes HOME ENERGY STATS Biggest energy consumers Space heating – 34% Appliances and lighting – 34% Refrigerator.
Chapter 27 Insulating Structures. Objectives After reading the chapter and reviewing the materials presented the students will be able to: List the ways.
The Buildings Envelope.  R Values are the thermal resistance of a building product. R values are given to certain materials to evaluate there ability.
 Helps to prevent the transfer of heat either into or out of a building  Winter – keep heat in  Summer – keep heat out  Heat is transferred through.
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
PASSIVE SOLAR DESIGN. Design Techniques
HEAT FLOW TO OR FROM A SPACE No habitable space has an envelope that is made of different materials with a consistent value of heat transmission through.
ARCH-432 Vapor Retarders and Air Barriers Attendance In what modern day country was the first cavity wall developed and used? For what purpose? A. Spain.
Chapter 4: Introduction to thermal control As we take on issues of thermal control it is important to keep in mind the following issues: 1.Human comfort.
Part 2: Buildings as a System Lee F. Ball Jr., PhD
HVACR416 - Design Heat Loss / Heat Gain Part 2. External Loads The greatest external load is the sun. The suns heat can get into a building in one of.
Energy Conservation February 8, Steve Wilson, MBA, CEM, CDSM, BEP The Energy Guy.
 On average, home heating uses more energy than any other system in a home  About 45% of total energy use  More than half of homes use natural gas.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
1 ISAT Module III: Building Energy Efficiency Topic 7: Transient Heating and Air Conditioning Loads  Thermal Admittance  Intermittent Heating 
Air Leakage and Water Vapor Control Chapter 6. Mehta, Scarborough, and Armpriest : Building Construction: Principles, Materials, and Systems © 2008 Pearson.
EXAMPLE EXERCISE CALCULATING HEAT LOSS & HEAT GAIN  Several exhibits in the class packet are necessary to understand the entries into the Heat Loss /
 On average, home heating uses more energy than any other system in a home  About 45% of total energy use  More than half of homes use natural gas.
Building Envelope. Physical separator between interior and exterior spaces – Walls – Floors – Roofs – Fenestrations (any opening in the structure) – Doors.
VENTILATION AND FENESTRATION
GCSE ENERGY; THERMAL ENERGY TRANSFER 2
Load Estimating Fundamentals
Heat Loss and Gain Civil Engineering and Architecture
Technology in Architecture
Ventilation Lesson 1: Principles of Air Flow & Moisture Control
RESIDENTIAL HVAC (HEAT LOSS & GAIN)
Thermal mass dynamics 1.00 Heat absorption
Heat gain and heat loss in buildings
Heat loss and heat gain in buildings: Outside air (OA) (Additional information) Required to be brought inside a building envelope to continuously replace.
Heat Loss and Gain.
Heat Loss and Gain Heat Transfer Winter Heat Loss Summer Heat Gain
Conduction Cooling Loads
Temperature and Heat Loss
Technology in Architecture
Heat Loss and Gain Heat Loss and Gain
Heat Loss and Gain Heat Loss and Gain
Technology in Architecture
Heat Loss and Gain Civil Engineering and Architecture
Technology in Architecture
Technology in Architecture
Lecture Objectives Psychrometrics Define Heating and Cooling Loads
Announcements Exam 1 Next Class (Thursday, March 14th):
Heat Loss and Gain Heat Loss and Gain
HEAT EXCHANGE IN BUILDINGS. TERMINOLOGIES Thermal conductivity: is the rate of heat flow through a unit area of unit thickness of the material for a unit.
Heat Loss and Gain Heat Loss and Gain
Presentation transcript:

HEAT LOSS & HEAT GAIN HEAT FLOW

Heat flows from high temperature to low temperature There are 3 types/methods of heat flow/transfer: 1.Conduction- through solids 2.Convection- through liquids & through convection currents in air 3.Radiation- through space (w/ or w/o air) Heat flow is measured in BTUs (amt. of heat needed to create a 1°F change in 1 pound of water. Flow is usually in BTU/hr. or BTUH.

HEAT FLOW

Insulation slows heat flow from conduction, convection &/or radiation. Most insulation uses trapped air to minimize conduction & convection (foam, fiberglass, dual pane glass). Radiation barriers are reflective and must face an air space to function.

Resistance to heat flow is R Higher is better R values can be for a specific thickness or expressed in R/inch. We usually look at assemblies of materials (construction) for walls, ceilings, roofs, floors or etc. This requires us to add the R values of all the materials in the assembly plus allowances for air films on the inside and outside surfaces.

CONDUCTANCE or U We typically look at the reciprocal value of this summation of Rs (1/R). This is the opposite of resistance which is conductance or U. It is measured by U=(BTUH) (1SF) (1°F).

TYPICAL U VALUES

Resistance Calculation- Example The first example in your textbook is for a concrete wall w/ brick veneer. Notice that the wood furring is not used in the calculations because it is not continuous. We look at the continuous layers of materials. In this case: the outside air film (0.2), 4 brick (0.4), air space w/ foil (3.0), 2 polyurethane (12.0), 5 concrete (0.5), air space w/o foil (1.0), ½ gyp. bd. (0.5) and the inside air film (0.7) for a total R of 18.3.

The internal temperature of the wall assembly can be determined at each layer of material by using the R values of the different layers in comparison to the total R value of the assembly times the Temperature Differential (TD) between the inside and the outside Why do we care about the temperature of any of these layers? Two reasons: 1.Comfort of people; low surface temperatures will increase the loss of body heat by radiation (you feel cold). 2.For many structures if there is humid air passing through the assembly there can be condensation inside the assembly causing problems w/ mold, mildew & deterioration of the materials (such as rotting/rusting framing).

HEAT FLOW Infiltration & Ventilation We need fresh air to flow into buildings in order to maintain a healthy environment. This air can come from infiltration- air that leaks into buildings through cracks and openings in the exterior shell or from ventilation- air purposely brought into the building using fans.

We usually allow 15 cubic feet per minute (CFM) per person. We also consider the number of air changes per hour. Both the recommended CFM/person and the air changes/hour can vary w/ conditions. There are tables and charts that give these recommendations or averages (15.2).

Infiltration is typically calculated by: OA= (Volume) (ACH) 60 (mins.) Where OA is the outdoor air in CFM; Volume is the CF of the buildings interior; ACH is the rate of air change per hour and 60 minutes gives you the air flow in minutes-CFM.

Ventilation Ventilation is typically calculated using the recommended cfm/person times the number of occupants.

In order to minimize the cost of heating and cooling: 1.Use outdoor air when it can warm (in winter) or cool (in summer) the inside. 2.Keep out outdoor air when it will impose additional heating or cooling loads. 3.When ventilation is needed, reduce energy loss by using a heat exchanger to temper the incoming air (warm it or cool it as appropriate).

Estimating Building Heat Losses Use the largest or highest heat loss. Calculate heat loss for: 1.Conduction through walls, roof, ceilings, floor & etc. Q= U x A x TD. 2.Infiltration of cold, outside air Q = CFM x 1.08 x TD.

Conduction: Q = U x A x TD Q= quant. Of heat flow in BTUH U= conductance in BTUH per sf per°F of the assembly A= area of the assembly in sf TD= Temperature Difference in °F between indoor & outdoor

You will need to calculate Q for each assembly (wall, roof, floor etc.) and total all the Qs.

Infiltration (outside air) Q= CFM x 1.08 x TD Q= quant. of heat flow in BTUH 1.08 is a constant; the # of BTUH needed to increase the temperature of 1 CFM of air 1°F. TD= the temperature difference in °F between indoor and outdoor air

INFO & CALCS REQUIRED For most assemblies you will need to calculate U by adding the R values of the components of the assembly. 1/Total R=U. Will need to calculate the SF of the assembly. (may need to deduct doors, windows & etc.) Will need to know the outside temperature & usually assume an indoor temperature of 70°F. Will also need the ventilation rate, if there is one, and use the higher of infiltration or ventilation CFM.

INFO & CALCS REQUIRED (cont.) You will also need to consider: *Ducts outside the insulated space (attic). *Basement walls & floors. *Unheated spaces adjacent to heated space (garage or storage). *Slab edge if it is exposed on the outside.

Use the form shown on p. 206 for calculating Building Heat Loss (or Gain) What you will need to know (for winter heat loss): 1.The winter design temperature (Fig. 15.8). 2.Infiltration & ventilation rates; pick the highest CFM (usually infiltration). 3.U values for various assemblies: glass (windows), roof, walls, floor, slab edge, doors & etc. 4.SF of each of these assemblies. 5.Add 10% if ductwork is in noninsulated space.

ON THE FORM Fill in factors and quantities, calculate each BTUH loss and total all the losses to get the Total BTUH Loss.

Office Building

Office Building Heat Loss 1. Location- 10°F winter temp. & 70°F indoor temp= 60°F TD. 2. Floor area= (180x60)2 floors = 21,600 sf. 3. Infiltration=0.75 air changes/hr x 21,600sf x 11clgs= 178,200CF /60 min= 2,970 CFM. 4. Given other top: glass 0.6 U, people 160, ceiling/roof 0.05 U, walls 0.07 U, floor factor of 2, door 1.1 U, slab edge 0.8 U.

Office Building Heat Loss (cont.) 5. Glass total given 2,400 sf. 6. Ceiling-roof & floor is ½ of 21,600 sf= 10,800 sf. 7. Wall area given 10,880 sf. 8. Slab edge (67) = 494 lf. 9. Doors 5x7= 70 sf. 10. Fill in info, do calcs, sum the numbers & get Total of 406,850 BTUH.