RADIANT HEATING SYSTEMS ECOFILM an electric heating foil.

Slides:



Advertisements
Similar presentations
Framing.
Advertisements

From : Michel MATHIEU to : Luis HERVAS CABLING sub-D 37 M for trigger cables 1- strip the cable cutting off the external gaine on a length of about 7cm.
ZH and ZR Connectors To introduce the ZH crimp style and ZR insulation displacement wire-to-board connector series.
Electrical Trunking Lincoln Robinson Caliphor Fagan Richard Lawrence
Presented By: FAOZIAH K.N.SUDHA RANI L.MAMTA VIJAY KUMAR UPADHYAY TIKESHWAR PRASAD VERMA.
NGfL CYMRU GCaD FLOOR COVERINGS.
Veneer and Laminates in Residential Construction Steve Kelly Advanced Diploma in Building Design(architectural) June 2009.
1. Install the heat insulation on the floor. 2. Install the power film on the heat insulation. 4. Connect the thermostat and temperature sensor with power.
Presentation for carbon heating film installation. Dear Customers, the carbon heating film is a new and advance heating technology used for wooden and.
Cable Management.
CRIMPING Introduction
…your final connection. Mine Cable Services Corporation. Cable Repairs: Vulcanized Splices.
Smart heat for comfort and safety 1 Self-regulating system to maintain water flow in gutters and downpipes.
New Mexico FFA Agricultural Mechanics Career Development Event Electric Power.
Equipment for Assembly Fluke Multimeter 115 True RMS Glue Ring Jig Flathead screwdriver 60 Watt desk lamp HIOS Cl 4000 Electric screw driver Anti-static.
VL Connector To introduce the VL wire-to-board and wire-to-wire, crimp style connector series.
Czech Technical University in Prague Faculty of Civil Engineering Department of Microenvironmental and Building Services Engineering Czech Technical University.
Group MAKING KITS Designed to deliver creative learning in your classroom or workshop.
AC-SSC-1 Installation and operation manual
1 Handtowel rolls The dispenser enMotion EM DISTRIBUTEUR ENMOTION.
Electronics. Solid snap together electronic connectors.
ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:
Installing Cable Floor Heating Systems This presentation will give you a practical idea of how to install a floor heating system.
Heating foil ECOFILM F Installation guide. ECOFILM F - OPTION Suitable for laminate floating floors: width(mm) input (W/m 2 ) F F (48V) 530.
One Way Circuits Limited Printed Circuit Board Manufacturer A Guide To Manufacturing Multilayer PCBs Use Left and Right Cursor keys to navigate ESC to.
Direct heating system ECOFLOOR Installation guide.
Presentation on Installation of a Domestic Cold Water Storage Cistern
Parts list 1 – 8’ 2” OD stainless steel pipe, chamfered at both ends 1 –7’ 4” PVC pipe 2 – 4” PVC end caps, with appropriate holes 1 – heater (model#=Omegalux.
㈜ D.S.T. 자료용 1. Power film Installation 1. Install the heat insulation on the floor. 2. Install the power film on the heat insulation. 4. Connect the thermostat.
PRACTICAL ELECTRONICS MASTERCLASS (Mr Bell) 1. Basic Electronic Components These components will be discussed further during the course, also have a look.
Dry lining.
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
Heating foil Ecofilm C Installation guide. ECOFILM C - OPTION For ceiling heating by heating foil ECOFILM C we offer following types : width (mm) output.
Dry lining by direct bond – overview
Drywall Theory. Dry Wall Saw Dry wall T-Saw Dry Wall Lift.
Parts list 1 – 8’ 2” OD stainless steel pipe, chamfered at both ends 1 –7’ 4” PVC pipe 2 – 4” PVC end caps, with appropriate holes 1 – heater (model#=Omegalux.
PLASTERBOARDS Plasterboard is a rigid flat sheet material which comprises of a core of gypsum plaster with the surfaces covered by stout paper. This covering.
Assignment By Ryan Shaw. Tools and Equipment Trowel- used for applying plaster Hawk- used for holding plaster whilst plastering Float- gives good.
SARDAR PATEL INSTITUTE OF TECHNOLOGY, PILUDARA Rakholiya bhavdip : [ ] Gevariya balkrushn : [ ] Patel parth : [ ] ( Branch:
RENAISSANC E CARPET TILES_.  INTRODUCTION_  BENEFITS_  SUGGESTED SPECIFICATION_  INSTALLATION INSTRUCTIONS_  MAINTENANCE PROCEDURES_  TECHNICAL.
Voltage Tester Used for testing voltage on electrical outlets, fuse clips, and circuit breakers will test voltage from 120 to 600 volts.
ELECTRICAL FIRES CAN BE PREVENTED! By PowerCheck.
UNDERGROUND CABLE.
OptiLine Mini-trunking Safe and smoothly shaped – and a joy to work with.
Direct Hot Water. What Cold Water System is Pictured? What hot Water System is Pictured?
What materials are the best conductors. Possible Materials Aluminum Foil Paper Clips Wood Plastic Rubber Bands String.
CONDUCTION, INSULATION AND PROTECTION. CONDUCTION Energy (eg. Electrical) transfer from one material to another by direct contact. Conductors are materials.
MORE THAN WOOD. As BLC Group, we produce the first domestic composite wood panels of Turkey. Our factory is located in Kahramanmaraş. We sell these high.
Unit 6: Building Technology in Construction Learning Outcome Understand the techniques used in the construction of superstructures for low-rise domestic.
Basic Slide Show Under Tile Spooled Heating Installation Guide.
Level 1 Diploma in Plumbing Studies © 2013 City and Guilds of London Institute. All rights reserved. 1 of 23 PowerPoint presentation Preparation techniques.
STATIC CONTROL TILES & SHEETING PRIMO SD. INTRODUCTION  Static Dissipative flooring is essential for protecting sensitive equipment from static charge.
Equipment & Utensils Using the Right Tools. Our Goal To provide information about the best selection, use and maintenance of food preparation equipment.
Technician’s Guide & Workbook for Duct Diagnostics and Repair.
WIRES, CONDUITS AND RACEWAYS Class Instructor : VINCENT J. DAYAG JR,MSArch.UAP.PIEP. Architect / Environmental Planner.
Smitty’s Two Minute Drill Grounding
Under floor heating Designing underfloor heating (UFH) system must always comply with the system suppliers instructions.
Agricultural Science Career Development Event Electric Power
No Solder Battery Interrupter
Board Replacement Laminate-Angle/Angle & Lock & Fold
Board Replacement for Floating Floors
UPPER FLOORS TIMBER AND CONCRETE.
presented by Innovative Manufacturing Solutions
Types of Cables.
Presented by: Richard Hathcoat & Alexander Millan
HYBRID COOKTOP.
Wiring the Light and Relay
Electrical components and systems
ELECTRICAL INSTALLATION
Level 2 Electrical and Electronic 3
Presentation transcript:

RADIANT HEATING SYSTEMS ECOFILM an electric heating foil

Convection: Radiators, fires, heaters etc.

ECOFILM F –Floor heating foil

ECOFILM F -Radiant heat

20 º 22 º 24 º 26 º 2.5 m ECOFILM C –ceiling radiant heating

The floor surface must be level and clean. Cut a channel in the concrete for the floor probe. It should lead to where the thermostat is to be placed. Put the floor probe into the channel and run the connection wire to the wall. Secure the probe with tape. Concrete sub floor

Lay hardboard on top of the floor boards to achieve a smooth, clean level surface. Put the floor probe into the channel and run the connection wire to the wall. Secure the probe with tape. Cut a groove in the board for the floor probe. Timber sub floor

Use Depron to insulate the floor. Secure the Depron using 2 tape. Cut a hole in the Depron where the floor probe is to be positioned.

The ECOFILM F can now be rolled out across the floor covering the area that is to be heated. Remember not to place the element under fixed objects in the room. The Flexel element is joined up in parallel leading to the point where the thermostat is to be placed. Install the thermostat making connections from the element and the floor probe.

A polythene sheet is laid over the top of the element. This can be replaced by the manufacturers recommended material if required for warranty. The laminate floor is laid on top of the polythene.

ECOFILM C –Ceiling heating foil

Install metal joists (5) to the ceiling structure (6), lay thermal insulation min. 50mm (4), spread the heating foil ECOFILM C (3), lay PE foil as moisture stop (2), carry out wiring, cover with plasterboard (max. 16 mm thick) (1) ECOFILM C – ceiling heating foil

ECOFILM C - installation

ECOFILM Construction Polyester/ Polyethylene foil (1), Copper electrodes (2), Silver coated strips (3), Carbon printed heating element (4), Polyester/ Polyethylene foil (5)

Fenix Crimping Tool Check calibration on a regular basis Equipment required for ceiling installation

Top ViewSide ViewSnapped together Fenix) t type connector cover AMP Termifoil (Fenix) Clear, 150C rated, polyester tape (Fenix)

Non – Heating Leads (Fenix) PVC ETFE 1.5 mm² single core 1.5 mm² Single core, double insulated, ETFE/ flexible PVC, Blue or black colour.

Check the roll for any damage including folds and creases. Damaged areas must be discarded

Seal both ends of element with Fenix tape

Fold AMP and close with thumb and forefinger Insert leads Insert element into crimp

Make 2 diagonal applications with the flat edge of the crimping tool on the crimp. Make application with the W section of the crimping tool on the cylindrical ferrule.

Equipment required for floor installation ) Crimp connectors 2) Vulkanized tape MASTIC 3) Polyester insulation tape 4) Connection cables 1,5 mm2: black and blue colour 5) Crimping tool

1) Check the roll for any damage including folds and creases. Damaged areas must be discarded 3) Seal both ends of element with Fenix tape 4) Insert leads. Insert element into crimp. Fold AMP and close with thumb and forefinger.

5) Crimp connector must be insulated by MASTIC strip.

Introduce lower section of t connector cover. Equipment required for ceiling installation

When crimp is in place introduce top section of t cover

Snap connector covers together. Repeat for all copper conductor end pieces.

ECOFILM Set An electric heating foil - DIY product - an effective system for laminate and wooden floor warming and heating. - The set contens: Strip of heating foil Ecofilm of 600-mm total width (heating active width getting 550 mm), of the 60W/m 2 or 80W/m 2 surface input, supplied in rolls of different lengths as the customer requires and in accordance with the laying plan. Couple of additional insulating discs (using in case of heating foil length cutting and need copper electrode strips insulation) Instruction manual

ECOFILM Set INSTALLATION STEPS The ECOFILM Set is installed directly under the laminate (floating) or timber floors in the same way as the standard ECOFILM F606 or F608 foils offered since many years. The floor structure is recommended as follows: 1 - laminate floating floor 2 - PE film 3 - ECOFILM F heating film 4 – INSULATION (Depron, Saarpor- Polyplan) 5 - baase concrete

ECOFILM Set LAY-OUT SAMPLE

ECOFILM Set INSTALLATION STEPS 1.The connection of the ECOFILM Set with connecting leads prepared in advance is just the great advantage because the installer or even the user by himself may very easily. Just the final electrical measuring and connection (interconnection of all connecting leads in the installation box and thermostat connection) shall be entrusted to a professional possessing the necessary qualification

ECOFILM Set PRODUCT RANGES

ECOFILM MHF An electric heating foil under mirror - an effective system for keeping the mirror completely steam-free. - ECOFILM MHF is connected to the lighting circuit so that it is activated when the light is switched on. - Self-adhesive side of ECOFILM MHF is placed on back of mirror after peeling of protective release paper. Mirror WITH a heating foil ECOFILM MHF Mirror WITHOUT a heating foil ECOFILM MHF

ECOFILM Products ranges Note :Types F 606 and 608 for the wooden and lamiante floors – there cannot be use heating film with higher output !!!

Recommended regulation method ECOFILM C – analogue or digital room thermostat FLASH 25614EBERLE RTR-E 6202EBERLE Instat 2 EBERLE Instat 6-2 ECOFILM F – analogue or digital thermostat with floor sensor FENIX Therm 100 M&S ECO M/z(s)2 EBERLE Instat 6-3 EBERLE Instat 8 MICROLINE OCD 1999 H

ECOFILM advantages vs metal foil ECOFILMMETAL FOIL - suits to ceiling construction (width of 40, 50 and 60 cm) - simply cut to length according to requested dimensions - easy electric connection (in parallel for direct return to the room thermostat position) - if Ecofilm will be damaged it can be simply repaired - limited modular sizes (making stocking difficult and transport difficults) - individual termination into separate termination boxes - in case of damage metal foil rerequires complete replacement

YOUR A RIGHT PARTNER IN AN ELECTRIC HEATING SYSTEMS Contact us : FENIX Trading s.r.o. Slezska Jesenik, Czech Rep. Tel/Fax: /303 Web: