Rotator Cuff Repair Augmented With Endogenous Fibrin Clot

Slides:



Advertisements
Similar presentations
Murat Bozkurt, M. D. , Mustafa Akkaya, M. D. , Safa Gursoy, M. D
Advertisements

“Double-Row Rip-Stop” Technique for Arthroscopic Rotator Cuff Repair
Arthroscopic Repair of Medial Transtendinous Rotator Cuff Tears
Arthroscopic Treatment of Calcific Tendonitis
Allison J. Rao, M. D. , Eamon Bernardoni, M. S. , Nikhil Verma, M. D
Biceps Tenodesis: Anatomic Tensioning
William J. Ciccone, M.D.  Arthroscopy Techniques 
Jefferson C. Brand, M.D., Paul Westerberg, M.A., A.T.C. 
Michael S. Laidlaw, M.D., F. Winston Gwathmey, M.D. 
Arthroscopic Transtendinous Biceps Tenodesis With All-Suture Anchor
Alan M. Hirahara, M.D., F.R.C.S.C., Wyatt J. Andersen, A.T.C. 
Latissimus Dorsi Tendon Transfer for Irreparable Rotator Cuff Tears: A Modified Technique Using Arthroscopy  Diego Villacis, M.D., Jarrad Merriman, M.P.H.,
Rotator Cerclage Technique for Partial Rotator Cuff Ruptures
Arthroscopic Management of Posterior Instability due to “Floating” Posterior Inferior Glenohumeral Ligament Lesions  Lawrence O'Malley, M.D., Eric D.
Arthroscopic Rotator Cuff Repair With Concomitant Capsular Release
Andrew A. Tarleton, M. D. , Liang Zhou, M. S. , Michael J. O'Brien, M
Eduard Buess, M.D., Michael Hackl, M.D., Peter Buxbaumer, M.D. 
An Augmentation Suture Technique for Arthroscopic Rotator Cuff Repair
The Simple Cow Hitch Stitch Technique for Arthroscopic Rotator Cuff Repair and Stabilization Using Knotless Suture Anchors  Nael Hawi, M.D., Christian.
Arthroscopic Repair of Type II SLAP Tears Using Suture Anchor Technique  Mathew Hamula, M.D., Siddharth A. Mahure, M.D., M.B.A., Daniel J. Kaplan, M.D.,
A. Ali Narvani, M. B. B. S. (Hons), B. Sc. (Hons), M. Sc. (Sports Med
Bashar Reda, M. B. B. S. , F. R. C. S. (C. ), Catherine Coady, M. D
Arthroscopic Treatment of a Reverse Hill-Sachs Lesion
Takeshi Kokubu, M. D. , Yutaka Mifune, M. D. , Atsuyuki Inui, M. D
Jovan R. Laskovski, M. D. , Jason A. Boyd, M. D. , Eric E. Peterson, M
Arthroscopic Bone Graft Procedure Combined With Arthroscopic Subscapularis Augmentation for Recurrent Anterior Instability With Glenoid Bone Defect  Raffaele.
Patrick J. Denard, M.D., Stephen S. Burkhart, M.D. 
Jonathan C. Levy, M.D.  Arthroscopy Techniques 
Padraic R. Obma, M.D.  Arthroscopy Techniques 
Rotator Cerclage Technique for Partial Rotator Cuff Ruptures
The “Parachute” Technique: A Simple and Effective Single-Row Procedure to Achieve an Increased Contact Area Between the Cuff-Tendon and Its Footprint 
Subscapularis Repair With the Suture Shuttle Loop Technique
The “Pull-Over” Technique for All Arthroscopic Rotator Cuff Repair With Extracellular Matrix Augmentation  A. Ali Narvani, M.B.B.S.(Hons), B.Sc., M.Sc.(Sports.
Gregory J. Gilot, M. D. , Ahmed K. Attia, M. D. , Andres M. Alvarez, M
Arthroscopic Suture Anchor Tenodesis: Loop-Suture Technique
Hytham Salem, B. A. , Aaron Carter, M. D. , Fotios Tjoumakaris, M. D
A Novel Arthroscopic Inside-Out Repair Technique for PASTA Lesions
Arthroscopic Superior Capsular Reconstruction for Treatment of Massive Irreparable Rotator Cuff Tears  Alan M. Hirahara, M.D., F.R.C.S.C., Christopher.
Using a Posterolateral Portal to Pass and Tie the Suture of the Inferior Anchor During Arthroscopic Bankart Repair  Walid Reda, M.D., Ph.D., Ahmed Khedr,
Dual-Camera Technique for Arthroscopic Rotator Cuff Repair
Amir Steinitz, M. D. , Peter Buxbaumer, M. D. , Michael Hackl, M. D
Arthroscopic Transtendinous Double-Pulley Remplissage Technique in the Beach-Chair Position for Large Hill-Sachs Lesions  Nata Parnes, M.D., MAJ Paul.
All-Arthroscopic Patch Augmentation of a Massive Rotator Cuff Tear: Surgical Technique  Peter N. Chalmers, M.D., Rachel M. Frank, M.D., Anil K. Gupta,
Modified Margin Convergence: Over-Under Lacing Suture Technique
Medial Patellofemoral Ligament Reconstruction: A New Technique for Graft Fixation at the Patella Without Implants  Sven Shafizadeh, M.D., Maurice Balke,
Arthroscopic-Assisted Pectoralis Minor Transfer for Irreparable Anterosuperior Massive Rotator Cuff Tear  Kotaro Yamakado, M.D., Ph.D.  Arthroscopy Techniques 
Eduard Buess, M.D., Michael Hackl, M.D., Peter Buxbaumer, M.D. 
Justin L. Makovicka, M.D., Karan A. Patel, M.D., John M. Tokish, M.D. 
Aaron J. Bois, M. D. , M. Sc. , F. R. C. S. C. , Steven Roulet, M. D
Anirudh K. Gowd, B. S. , Joseph N. Liu, M. D. , Grant H. Garcia, M. D
Gluteus Medius Repair With Double-Row Fixation
Tim Spalding, F. R. C. S. (Orth), Ben Parkinson, F. R. A. C. S
Paolo Consigliere, M. D. , Natasha Morrissey, M. D. , Mohamed Imam, M
Margin Convergence in Rotator Cuff Repair: The Shoelace Technique
Néstor A. Zurita Uroz, M. D. , Ph. D. , Ferran Abat, M. D. , Ph. D
Arthroscopic Remplissage for Moderate-Size Hill-Sachs Lesion
Eugenio Savarese, M.D., Ph.D., Rocco Romeo, M.D. 
“Double-Row Rip-Stop” Technique for Arthroscopic Rotator Cuff Repair
Daisuke Mori, M.D., Noboru Funakoshi, M.D., Fumiharu Yamashita, M.D. 
Single Portal Subscapular Repair by a Cross Shuttle Loop Technique
Avinesh Agarwalla, B. S. , Richard N. Puzzitiello, B. S
Single Portal Subscapular Repair by a Cross Shuttle Loop Technique
The Fertilized Anterior Cruciate Ligament: An All-Inside Anterior Cruciate Ligament Reconstruction Augmented With Amnion, Bone Marrow Concentrate, and.
The Simple Cow Hitch Stitch Technique for Arthroscopic Rotator Cuff Repair and Stabilization Using Knotless Suture Anchors  Nael Hawi, M.D., Christian.
“Owl” Technique for All-Arthroscopic Augmentation of a Massive or Large Rotator Cuff Tear With Extracellular Matrix Graft  A. Ali Narvani, M.B.B.S.(Hons),
Paul E. Caldwell, M. D. , Adam J. Heisinger, D. O. , Sara E
Arthroscopic Repair of Rare Transtendinous Rotator Cuff Tear: Utilizing Established Portals and a Posterior Superior Accessory Portal  Shane Anderson,
Gregory Gasbarro, M.D., Lionel Neyton, M.D.  Arthroscopy Techniques 
All-Arthroscopic Biceps Tenodesis by Knotless Winding Suture
Arthroscopic Reverse Remplissage for Posterior Instability
Presentation transcript:

Rotator Cuff Repair Augmented With Endogenous Fibrin Clot Christopher S. Proctor, M.D.  Arthroscopy Techniques  Volume 1, Issue 1, Pages e79-e82 (September 2012) DOI: 10.1016/j.eats.2012.03.002 Copyright © 2012 Arthroscopy Association of North America Terms and Conditions

Figure 1 The endogenous fibrin clot ring forms on the sintered glass cylinder after 30 mL of the patient's blood is swirled in the cup for 10 minutes. Forming the fibrin clot in this fashion aligns fibrin and imparts a structural integrity readily allowing for suture fixation. Arthroscopy Techniques 2012 1, e79-e82DOI: (10.1016/j.eats.2012.03.002) Copyright © 2012 Arthroscopy Association of North America Terms and Conditions

Figure 2 With the patient in the lateral position, the No. 0 Vicryl docking sutures are brought out through the flexible lateral cannula in this right shoulder. The endogenous fibrin clot is tied to the No. 0 Vicryl docking sutures with multiple square knots. Arthroscopy Techniques 2012 1, e79-e82DOI: (10.1016/j.eats.2012.03.002) Copyright © 2012 Arthroscopy Association of North America Terms and Conditions

Figure 3 With the endogenous fibrin clot secured to the 2 No. 0 Vicryl docking sutures with multiple square knots, the endogenous fibrin clot is first pulled into a metal cannula with an arthroscopic grasper and then passed through the dam of the flexible lateral cannula and into the subacromial space. In this image of a right shoulder with the patient in the lateral position and viewed from the posterior portal, the endogenous clot secured to the No. 0 Vicryl sutures is emerging from the metal cannula that is used to pass the clot through the dam of the flexible lateral cannula. Arthroscopy Techniques 2012 1, e79-e82DOI: (10.1016/j.eats.2012.03.002) Copyright © 2012 Arthroscopy Association of North America Terms and Conditions

Figure 4 Once passed into the subacromial space, the endogenous fibrin clot is “docked” to the superior aspect of the rotator cuff repair at the tendon-bone interface by simultaneously pulling on the ends of the No. 0 Vicryl sutures exiting the anterior and posterior portals, respectively. With the endogenous fibrin clot docked, the ends of the sutures are brought out through the lateral cannula and tied arthroscopically medial to the clot-repair interface. This image of a right shoulder with the patient in the lateral position is viewed from the lateral portal and shows the endogenous fibrin clot docked on the superior aspect of the tendon-bone interface and the sutures tied medially. Arthroscopy Techniques 2012 1, e79-e82DOI: (10.1016/j.eats.2012.03.002) Copyright © 2012 Arthroscopy Association of North America Terms and Conditions