Beyond stents: third-generation coronary devices

Slides:



Advertisements
Similar presentations
The SAFER Trial Evaluation of the Clinical Safety and Efficacy of the PercuSurge GuardWire in Saphenous Vein Graft Intervention As presented at TCT 2000.
Advertisements

Two generations of the St
Surgical retrieval of an embolized central venous catheter in a premature baby  Pietro A Abbruzzese, MD, Enrico Chiappa, MD, Pierclaudio Murru, MD, Lino.
Early use conversion of the HeRO dialysis graft
Leena Khaitan, MD, Francis P Sutter, Scott M Goldman, MD 
Tips and techniques in carotid artery stenting
Coronary artery bypass grafting in patients with advanced left ventricular dysfunction  Gregory D Trachiotis, MD, William S Weintraub, MD, Thomas S Johnston,
Improved Early Survival With a Nonsternotomy Approach for Continuous-Flow Left Ventricular Assist Device Replacement  Matthew A. Schechter, MD, Chetan.
An experimental model of saphenous vein-to-coronary artery anastomosis with the St. Jude medical stainless steel connector  Hartzell V Schaff, MD, Kenton.
Hartmuth B Bittner, MD  The Annals of Thoracic Surgery 
Balloon-assisted over-the-wire technique for placement of the venous outflow component of the Hemodialysis Reliable Outflow (HeRO) device  Hector Ferral,
A New Endoluminal Resection Technique and Device: Resector Balloon
Failure of internal thoracic artery grafts: conclusions from coronary angiography mid- term follow-up  Eric Bezon, MD, Jean N Choplain, MD, Yasser A Maguid,
Extubation of the Patient After a Difficult Intubation
Ergun Demirsoy, MD, Kamil Umut Sarkislali, MD 
Mesenteric artery complications during angioplasty and stent placement for atherosclerotic chronic mesenteric ischemia  Gustavo S. Oderich, MD, Tiziano.
Major leg wound complications after saphenous vein harvest for coronary revascularization  Christian E Paletta, MD, David B Huang, MD, Andrew C Fiore,
Clinical significance of embolic events in patients undergoing endovascular femoropopliteal interventions with or without embolic protection devices 
Patrick H McNulty, MD, Ian C Gilchrist, MD 
Two generations of the St
Rakesh M. Suri, MD, DPhil, Alfred G. Valles, MD, Samuel J
Endoscopic Saphenous Vein Harvesting
A multicenter experience evaluating chronic total occlusion crossing with the Wildcat catheter (the CONNECT study)  John P. Pigott, MD, FACS, M. Laiq.
True lumen re-entry devices facilitate subintimal angioplasty and stenting of total chronic occlusions: Initial report  Donald L. Jacobs, MD, Raghunandan.
Tube device for facilitating distal anastomosis in aortic arch replacement  Tadahiro Sasajima, MD, Kazutomo Goh, MD, Hidenori Asada, MD, Tokihito Sugawara,
Kook-Yang Park, MD, Chul-Hyun Park, MD  The Annals of Thoracic Surgery 
Central venous catheter use in low-risk coronary artery bypass grafting  Robert D Stewart, MD, Triffin Psyhojos, MD, Stephen J Lahey, MD, Sidney Levitsky,
Factors Influencing Mortality After Emergency Coronary Artery Bypass Grafting for Failed Percutaneous Transluminal Coronary Angioplasty  Harold L Lazar,
Scott S. Berman, MD, MHA, FACS, Shonda L. Banegas, DO 
Myocardial revascularization with the posterior tibial artery
Limitations of the Outback LTD re-entry device in femoropopliteal chronic total occlusions  Susanna H. Shin, MD, Donald Baril, MD, Rabih Chaer, MD, Robert.
Coronary artery bypass on the beating heart with the Octopus: a North American experience1  Ted H Spooner, MD, Peter E Dyrud, MD, Bjorn K Monson, MD,
Use of a percutaneous puncture needle for true lumen re-entry during subintimal recanalization of the superficial femoral artery  Amr M. Aborahma, MD 
Clinical and economic evaluation of the trellis thrombectomy device for arterial occlusions: preliminary analysis  Timur P. Sarac, MD, Daniel Hilleman,
Flow control technique to prevent distal embolization during mechanical thrombectomy  Mathew Wooster, MD, Daniel Kloda, DO, Jacob Robison, MD, Joseph Hart,
Sutureless coronary artery bypass with biologic glued anastomoses: Preliminary in vivo and in vitro results  Steven R. Gundry, MD, Kirby Black, PhD, Hironori.
Early use conversion of the HeRO dialysis graft
T. Carrel, MD, M. Pasic, MD, U. Niederhäuser, MD, M. Turina, MD 
Pathology of the Radial and Internal Thoracic Arteries Used as Coronary Artery Bypass Grafts  Eric Kaufer, BS, Stephen M Factor, MD, Rosemary Frame, MS,
Conduits and endoconduits, percutaneous access
The Annals of Thoracic Surgery
A Simple Device for Morphofunctional Evaluation During Aortic Valve-Sparing Surgery  Alessandro Leone, MD, Piergiorgio Bruno, MD, Federico Cammertoni,
Daniel S. Kassavin, MD, Daniel G. Clair, MD 
Editorial Board, January 2010
Left atrial pressure measurement in a rat is currently impossible due to size limitations of balloon occlusion catheter  Filip Konecny, MSc, DVM, PhD 
Duplex-guided balloon angioplasty and stenting for femoropopliteal arterial occlusive disease: An alternative in patients with renal insufficiency  Enrico.
A man with saphenous vein graft aneurysms after bypass surgery
Koji Kawahito, MD, Hideo Adachi, MD  The Annals of Thoracic Surgery 
Mark A. Farber, MD, Robert R. Mendes, MD  Journal of Vascular Surgery 
Joseph Galea, MD, FRCS, Alexander Manché, MPhil, FRCS 
Surgical retrieval of an embolized central venous catheter in a premature baby  Pietro A Abbruzzese, MD, Enrico Chiappa, MD, Pierclaudio Murru, MD, Lino.
Kagami Miyaji, MD, Randall K Wolf, MD, John B Flege, MD 
Multicenter experience with the remote access perfusion (RAP) catheter
Tissue valve, nitinol stent, or storage solution
Max B. Mitchell, MD, David N. Campbell, MD 
Ioannis Prionidis, MD, Tom F. Browne  Journal of Vascular Surgery 
“Transitions” for Cardiothoracic Surgeons Now Listed on the Web:
Sérgio A de Oliveira, MD  The Annals of Thoracic Surgery 
Catheter-Based Endoscopic Bypass Grafting: An Experimental Feasibility Study  Stephan Jacobs, MD, David Holzhey, MD, Hubert Stein, BS, BME, Friedrich W.
Successful surgical endarterectomy of a stented coronary artery
Off-pump grafting of the main circumflex coronary artery in the atrioventricular groove via sternotomy  Thomas A Vassiliades, MD  The Annals of Thoracic.
Flow Capacity of Gastroepiploic Artery Versus Vein Grafts for Intermediate Coronary Artery Stenosis  Tsuyoshi Shimizu, MD, PhD, Hiroyuki Suesada, MD,
Arterial balloon catheter: a new atraumatic device for dilating arterial grafts  Hugues Jeanmart, MD, Louis P Perrault, MD, PhD, Nathalie Desjardins, BS,
Utilization and Outcomes of Unprotected Left Main Coronary Artery Stenting and Coronary Artery Bypass Graft Surgery  Chuntao Wu, MD, PhD, Edward L. Hannan,
Pitfalls and key lessons with the symmetry proximal anastomotic device in coronary artery bypass surgery  Thierry P Carrel, MD, Friedrich S Eckstein,
Mycotic Coronary Artery Aneurysm From Fungal Prosthetic Valve Endocarditis  Wing Yeen, MBBS, MBA, Antonio Panza, MD, Stephen Cook, MD, Christopher Warrell,
Faisal G. Bakaeen, MD, Joseph S. Coselli, MD, Scott A
A.Marc Gillinov, MD, Patrick M McCarthy, MD 
Use of a percutaneous puncture needle for true lumen re-entry during subintimal recanalization of the superficial femoral artery  Amr M. Aborahma, MD 
J. Alberto Lopez, MD  The Annals of Thoracic Surgery 
Presentation transcript:

Beyond stents: third-generation coronary devices Stephen N Oesterle, MD  The Annals of Thoracic Surgery  Volume 66, Issue 3, Pages 1045-1049 (September 1998) DOI: 10.1016/S0003-4975(98)00713-9

Fig 1 Spectranetics Laser wire. This independently movable wire is coupled to a pulsed laser. It actively crosses chronic total occlusions and then serves as a “rail” to support the delivery of angioplasty devices. The Annals of Thoracic Surgery 1998 66, 1045-1049DOI: (10.1016/S0003-4975(98)00713-9)

Fig 2 CardioGenesis PMR laser delivery system. These photographs of the working end of the catheter depict the 1.75-mm lens coupled to a 400-μm optical fiber. The nitinol petal array retards full transmural advancement of the device. The Annals of Thoracic Surgery 1998 66, 1045-1049DOI: (10.1016/S0003-4975(98)00713-9)

Fig 3 PercuSurge embolization containment system. (A) A 0.014-inch GuardWire is advanced beyond the diseased vein graft segment. The distal tip of the GuardWire carries an elastomeric low pressure occlusion balloon. The GuardWire is delivered through a standard guiding catheter. (B) The distal occlusion balloon is inflated and angioplasty and stenting of the vein graft is completed. (C) With the distal occlusion balloon still inflated, the angioplasty device is removed over the GuardWire and an aspiration catheter (Export catheter) is advanced and particulate debris removed before deflation of the distal occlusion balloon. The GuardWire is then deflated and removed. The Annals of Thoracic Surgery 1998 66, 1045-1049DOI: (10.1016/S0003-4975(98)00713-9)