WATER TREATMENT By Chemist Ayman Awny Website :www.resategypt.com

Slides:



Advertisements
Similar presentations
The Basics of Demineralisation by Ion Exchange
Advertisements

Water Systems: water conditioning for Process and Boiler use
Hard Water. Clogged Pipes – Hard Water limestone hard water carbonic acid Step 1: Acid rain is formed Step 2: Acid rain dissolves limestone Water softener.
Water Hardness.
Introduction to Water Quality Engineering. DRINKING WATER STANDARDS Primary Standards, enforeceable by law are parameters that directly affect human health.
Overview AST Clean water technologies was requested to design and construct an Industrial Waste water Treatment Plant with a capacity of 35 m 3 /h in.
1 Clean Steam – The Basics Presenters: -Marie LaFrance, -George Godfrey,
File Name: Conductivity.pptFeb 2001 Conductivity Theory Applied to Proper Hardware Selection.
HARD WATER AND SOFT WATER
CE 547 Softening. What is Hardness Hardness is –the ability of the water to consume excessive amounts of soap before foaming –OR the ability of the water.
KAUSAR AHMAD KULLIYYAH OF PHARMACY PHM3133 Dosage Design /11 1 Steam as a heating medium
BOILER WATER TREATMENT THE POLYAMINE SOLUTION
HSC Chemistry – Acidic Environment R Slider. * The pH of a salt depends upon the relative strength of the ions that make up the salt * Very few salts.
Effective Lime/Soda Ash Water Softening
ENVE 420 Industrial Pollution Control NEUTRALIZATION Dr. Aslıhan Kerç.
1 Industrial Chemical Metering and Control Applications Industrial Plant Incoming Water Filtration, Chlorination, RO/DI Utilities Cooling Water, Boiler.
Plant Utility System (TKK-2210) 14/15 Semester 4 Instructor: Rama Oktavian Office Hr.: M-F
Water Treatment Part 3 Groundwater Treatment
WATER SOFTENING & ION EXCHANGE—ZEOLITE PROCESS
Phosphorus Removal The most common method to remove phosphorus from a waste stream is chemical precipitation. The common precipitating cations are Ca,
Water: Removing dissolved solutes. Precipitation reactions When two solutions are mixed and a solid forms it is called a precipitation reaction The precipitate.
Chemical Weathering. I. Introduction Chemical Weathering I. Introduction II. Process of Decomposition A. Overview: Decomposition alters minerals into.
Alkalinity, Hardness, & Lime/Soda Ash Softening
Basic Methods for Water Treatment
IV. Water Chemistry A. pH, hardness, and other ionic compounds and gases affecting water quality.
NACE Corpus Christi, TX – Nace Section Meeting May 20, 2014
Spring, 2012 Session 4 – General Chemistry Pt 2.  Inorganic chemistry applications to process technology  Analytical methods.
Reverse Osmosis Feed Treatment, Biofouling, and Membrane Cleaning
Water Conditioning Process
1 Waste Treatment, Chemical ENVE Why Treat Waste Have a RCRA Waste –TSDS –Treat instead of disposal, landfill –Treat before disposal Or treat in.
Purifying and Softening Water L.O: L.O: To know how to soften and purify hard water, and the pros and cons associated with this.
Power Plant Construction and QA/QC Section 2.6– Water Treatment
The Carbon Cycle. Carbon Dioxide and Carbonate system Why is it important? 1. Regulates temperature of the planet 2. Important for life in the ocean 3.
PH and Chemical Equilibrium. Acid-base balance Water can separate to form ions H + and OH - In fresh water, these ions are equally balanced An imbalance.
Ion Exchange Resin: SERVICE RESIN BEAD Cation resin bead attract and hold positively charged ions.Cation resin bead attract and hold positively charged.
Ion-exchange process (softener plant) Water passes through bed of natural zeolite of synthetic resin to remove hardness Calcium (Ca) and magnesium (Mg)
Chemical Equations Molecular, Total Ionic & Net Ionic Equations.
Acids, Bases and pH Water molecules dissociate Dissociates into OH- and H+ Water is neutral because there are equal numbers of OH- and H+
CEE 160L – Introduction to Environmental Engineering and Science Lecture 9 Drinking Water.
TECHNICAL BOILER TRAINING Introduction u Water is the raw material most used in nearly all industries. u US industry uses about 140 billion gallons per.
Water Treatment By : Shraddha( ) Hardik( ) Chirag( ) Aadil( ) Chemical Process Industries-1 C.E. 3 rd Sem.
Analysis Questions: 1.What does pH measure? the concentration (not “amount”) of hydrogen (H+) ions in a solution. 2.Which pH has the highest concentration.
UNIT-IV WATER AND ITS TREATMENT
ACID – BASE REACTIONS Chapter 25. When Acids and Bases Interact Acids are proton donors (Their chemical formulas begin with H-) Acids are proton donors.
5.2 - Salts Salts are a class of ionic compounds formed when:  acids and bases react  oxides or carbonates react with acids  metals react with acids.
Associate Professor (H & S)
FilterSorb SP3 Treatment Methode: Part II -by Deepak Chopra 1.
Applied to Proper Hardware Selection
Acids, Bases, and pH.
Special Oxygenized Drinking Water
RO Basics and System set up
Water Purification and treatment
Soil Chemical Properties
UNIT-IV WATER AND ITS TREATMENT
Conductivity.
Boiler System Make-up Water Primary Secondary Pretreatment
WATER QUALITY (Chapter 22)
MULTIPLE CHOICE QUESTIONS
ENGINEERING CHEMISTRY – II
Introduction What is the goal of Water Treatment Technologies?
به نام يگانه خالق هستی.
Softening of Water : Softening can be done in two ways
Chemical Weathering SAPROLITE.
Water and its treatment (3)
Ocean Acidification Topics Acids Bases pH Scale Ocean Acidification.
Water Impurities and Purification
Water Hardness.
Notes: The pH Scale The pH scale is used to measure the strength of an acid or a base. pH scale runs from 0 to 14.
Acids and Bases When water dissociates,
Feed Water Treatment for Steam Power plant
Presentation transcript:

WATER TREATMENT By Chemist Ayman Awny Website :www.resategypt.com معالجة المياه WATER TREATMENT By Chemist Ayman Awny RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Website :www.resategypt.com Introduction Problems Of Water Treatment. Water Treatment In Industry. Water Treatment In Hotels,Hospitals & Building. RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Website :www.resategypt.com مشاكل المياه الأساسية Micro. Corrosion 1 1 Corrosion 2 Suspended Solid 3 Scale 4 Micro-Organism 4 2 Scale Suspended. Solid 3 RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Website :www.resategypt.com Topics of Discussion Corrosion. Scale Formation. Suspended Solids. RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Boiler Water Treatment Website :www.resategypt.com

Problems in Boiler Systems Corrosion free carbon dioxide oxygen Deposits hardness organic matter corrosion products Suspended Solids corrosion product scale product RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Website :www.resategypt.com Topic One التآكــــل Corrosion RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Website :www.resategypt.com Causes of Corrosion Boiler Area Insufficient oxygen removal in feed water High pH value and alkalinity Increase in suspended solids Steam and Condensate Area Formation of carbon dioxide Insufficient oxygen removal in the feed water Low pH-values RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Website :www.resategypt.com التآكل هو عملية تحول الحديد الي أحد أكاسيده مما يقلل العمر الإفتراضي للمعدن طبقا لهذه المعادلات O2 Fe2+ Fe(OH)3 ANODE ANODE REACTION Fe° = Fe2+ + 2 e- CATHODE CATHODE REACTION ½ O2 + H2 O + 2 e- = 2OH- OH- WATER ELECTRON FLOW RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Fundamental Risks In Boiler Water Website :www.resategypt.com Causes of Corrosion Fundamental Risks In Boiler Water Standard Corrosion Reaction Fe -------->Fe ++ + 2 e - 2e- + 1/2 O2 ----->2 OH- 2e - + 2H+ ----->H2 RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Website :www.resategypt.com Causes of Corrosion Fundamental Risks in Steam and Condensate System Carbonic acid Behavior (corrosion) inside boiler : 2(H CO3Na )------->Na2CO3 + CO2 + H20 Na2 CO3 + H2O -----> 2 NaOH + CO2 in condansate system : H20 +CO2 --------> H+ + HCO3- RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Website :www.resategypt.com أشكال التآكل فى صورة تآكل سطحي فى صورة نقر. فى صورة تآكل منتظم. في صورة شروخ RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Surface Corrosion + Sludge RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Corrosion in steam line RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Pitting corrosion

Pitting Corrosion Inside Boiler RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

High pH Caustic corrosion RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Scheme of a Boiler System Cooling Water Consumer Return Condensate Condenser Steam Make-up Water De aeration Feed water Blow-down Filtration Unit Boiler feeding Pump e.g. Reservoir Ion Exchanger, of Feed water Reverse Osmosis Softeners Steam Boiler RESAT EGYPT WATER TREATMENT Website :www.resategypt.com Chemical Dosing

Classification of Boiler Systems Low Pressure Boiler Operating pressure up to 68 bar High Pressure Boiler operating pressure above 68 bar RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Website :www.resategypt.com أسباب التآكل # وجود الأكسجين الذائب بالمياه وتأثيره # ارتفاع نسبة الأس الهيدروجينى (pH ) أو انخفاضه. ( ارتفاع القلوية أو الحمضية) # إرتفاع درجة الحرارة. # نوعية مياه التعويض. # الاملاح العالقة RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

العلاقة بين مياة التعويض والتآكل كيفية تحديد العلاقة . اولا : التحليل الكيمائى لمياة التعويض. RIZENER INDX ثانيا: ربط التحليل بمعامل الريزنر RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

العلاقة بين الاكسجين الذائب في المياه و درجة الحرارة O2 C° 8.11 25 7.53 30 7.04 35 6.59 40 6.10 45 5.57 50 5.20 55 4.76 60 4.30 65 3.70 70 3.40 75 2.89 80 2.20 85 1.63 90 0.80 95 0.1 100 RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Corrosion Of Steel VS Boiler Water pH RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Website :www.resategypt.com مقاومة التآكل CORROSION PROTECTION ضبط pH ترشيح جيد للمياه لإزالة الأملاح العالقة. إزالة الاكسجين ميكانيكيا ( بالتسخين ). ضبط الأملاح الكلية ( TDS ) المعالجة الكيميائية RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

DEAERATOR

FEED TANK

Boiler Water Limits and Steam Purity( 1 ) (1) Approved by ASME (2) Changes according to TDS of B.F.W. (3) Changes according to TDS of B.F.W. (4) Determined depending on boiler water treatment program (5) Silica is not included RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

الترسبات scales

هى املاح تخرج من محلولها فى صورة املاح عالقة ويتم ذلك بتأثير الحرارة . وتتسبب فى حدوث قشرة صلبة على جدار المواسير

العلاقة بين نسبة الكالسيوم الذائب ودرجة الحرارة

الاملاح الشائعة المسببة للقشرة

الكالسيوم ماغنسيوم سيليكا اكسيد الحديد

Scale Problem (In Boiler )

Scale After Treatment

الأملاح العالقة Suspended Solids

Website :www.resategypt.com بعض الاملاح العالقة مثل. الأتربة الرمال بعض الملوثات مثل الزيوت ارتفاع نسبة الاملاح الذائبة عن الحد المطلوب RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

المشكلات التى تسببها الأملاح العالقة التآكل الميكانيكي Corrosion الترسيبات Scale الفوران Foaming RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Website :www.resategypt.com Lime Softening Mode of action Addition of lime milk Ca(OH)2 Elemination of carbonate hardness and carbon dioxide Reactions Precipitation of Ca-hydrogen carbonate Ca(HCO3)2 + Ca(OH)2  2CaCO3  + 2 H2O Neutralization of carbon dioxide CO2 CO2 + Ca(OH)2  CaCO3  + H2O Disadvantage Disposal of calcium carbonate sludge RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

Website :www.resategypt.com Ion Exchange / Basics Mode of action Physical-chemical methods Up-take of specific ions to the ion exchanger resin Delivery of an equivalent amount of different equally charged ions Kinds of ion exchangers Cationic ion exchanger Anionic ion exchanger Mixed bed ion exchanger RESAT EGYPT WATER TREATMENT Website :www.resategypt.com

التحليل الكيمائى لمياة التعويض نوع التحليل CITY WATER SOFTENED WATER DEIONIZER WATER pH 7.5 7.6 6.0-7.5 Ca H عسر الكالسيوم 90 M ALK القلوية الكلية 140 <10 TDS الاملاح الذائبة 250 TEMP. درجة حرارة 25 Corrosion Rate 3.2 MPY 30 MPY 60 MPY

Website :www.resategypt.com Questions My Regards Ayman Awny RESAT EGYPT WATER TREATMENT Website :www.resategypt.com