Corneal Biomechanical Assessment using Dynamic Ultra High-Speed (UHS)

Slides:



Advertisements
Similar presentations
A Wireless, Implantable Intra- Ocular Pressure Sensor for the Management of Glaucoma Gabriel Simon, M.D. Ph.D. Sept 16, 2008 ESCRS.
Advertisements

Asymmetric Keratoconus Study: Novel Tomographic Parameters to enhance sensitivity to detect abnormalities in eyes with normal axial curvature maps from.
Corneal biomechanical properties and their association with intraocular pressure (IOP) and central corneal thickness (CCT) Dimitrios P. Bessinis 1, Pandelis.
A Prospective Trial Evaluating Scleral Rebound Tonometry Sara Duke, MD, Andrew Logeman, Shuchi Patel, MD Loyola University Chicago, Department of Ophthalmology,
Two dimensional elasticity mapping of partially cross-linked rabbit corneas using optical coherence elastography Jiasong Li 1, Manmohan Singh 1, Srilatha.
Recent Advances in IOP measurements
Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.
Biomechanical Properties of Healthy and Keratoconic Corneas Evaluated Using an Ultra-High-Speed Scheimpflug Camera nznec Department of Ophthalmology University.
Corneal Biomechanics, Pachymetric Progression Profile and Corneal Volume: Indices for Detecting Ectasia and Screening Refractive Candidates Renato Ambrósio.
© R. Ambrósio Jr, MD, PhD R. Ambrósio Jr & Rio de Janeiro Corneal Tomography and Biomechanics Study Group Corneal Biomechanical Assessment using.
E-Poster ALC Canedo, MD 2010 Rio de Janeiro CornealTomograhyandBiomechanics Study Group Study Group Comparative Study of Corneal Biomechanical Properties.
Purpose We studied the interdevice agreement of three systems in the different measurements of the corneal and anterior segment biometric parameters. The.
Correlation between Preoperative cataract grading by Scheimpflug imaging and phaco time and power US in phacoemulsification. Bruno Valbon; Ana Canedo;
Anterior Chamber Depth, Iridocorneal Angle Width, and Intraocular Pressure Changes After Phacoemulsification: Narrow vs Open Iridocorneal Angles Huang.
Phacoemulsification with Goniosynechialysis in the Management of Refractory Acute Angle-closure Glaucoma Ghasem Fakhraie*, MD, Mahmoud Jabbarvand, MD,
SEI IOP and its correlations in a population based study in Central India. The Central India Eye and Medical Study. Krishna Bhojwani, Vinay Nangia, Jost.
E-Poster ALC Canedo, MD 2010 Rio de Janeiro CornealTomograhyandBiomechanics Study Group Study Group The impact of reference body selection for calculating.
CR The Glaucoma Tonometer. What sets it apart? Reichert’s 7CR Auto Tonometer + Corneal Response Technology takes corneal biomechanical properties into.
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. David Zadok, MD, Yakov Goldich, MD, Yaniv Barkana,
A Prospective Trial Comparing Scleral Pneumotonometry to Goldmann Applanation Tonometry Sara Duke, MD, Usiwoma Abugo, BS, Shuchi Patel MD Loyola University.
Implantable Optofluidic Sensor for Assessment of Intraocular Pressure Christina Antonopoulos MD, Mostafa Ghannad-Rezaie, Nikos Chronis PhD, Shahzad Mian.
TRANSPALPEBRAL TONOMETER APPLICATION DURING INTRAOCULAR PRESSURE EVALUATION IN THE PATIENTS WITH REFRACTION ANOMALY BEFORE AND AFTER KERATOPHOTOREFRACTIVE.
Purpose: Introduction:  At initial evaluation: For post-op day # 0 patients: Pre-op VA was 20/50.6 (0.395 ± 0.198); Post-op VA was 20/102.0 (0.196 ± 0.162);
Presents: Diaton Tonometer Tonometry through the Eyelid! September 2006.
Glaucoma Screening With a New Non-Contact Air Impulse Tonometer Pandelis A. Papadopoulos,1,2, Dimitrios P. Bessinis 3, Alexandros A. Papadopoulos 1, Konstantinos.
Relationship between Pachymetry and Ocular Response Analyzer Measurements Alejandro Rivera MD.
Assessment of wave propagation in mice cornea and lens using phase stabilized swept source optical coherence tomography Ravi K. Manapuram, Floredes M.
Effect of Corneal Thickness on Selective Laser Trabeculoplasty to Decrease Intraocular Pressure as Primary or Secondary Treatment of Glaucoma ASCRS 2010.
Khairidzan Mohd Kamal MD
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. Yakov Goldich, MD, David Zadok MD, Yaniv Barkana,
Rio de Janeiro Corneal Tomography and Biomechanics Study Group Dr. Ambrósio is consultant for Oculus Optikgeräte GmbH (Wetzlar, Germany) Agreement of Artificial.
Emmetropia and the Ametropias Scott P. Drexler OD University of Pittsburgh School of Medicine.
Naomi R. Goldberg, MD PhD Kenneth J. Wolf, MD Eric J. Wolf, MD FACS The authors have no financial interest in the subject matter of this poster. Comparison.
A Prospective Trial Comparing Pneumotonometry of Cornea and Sclera Usiwoma Abugo BS 1, Sara Duke MD 2, Shuchi Patel, MD 2 1 Loyola University Chicago,
MOTHODS OF OBJECTIVEEXAMINATION OBJECTIVEEXAMINATION Pavel Stodůlka.
E-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group The study of the correlations of the optic disc size with Cornal Geometry and Biomechanical.
Rio de Janeiro Corneal Tomography and Biomechanics Study Group CORNEAL TOMOGRAPHY AND BIOMECHANICAL FINDINGS OF CONCOMITANT KERATOCONUS AND CORNEAL GUTTATA.
E-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group e-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group Clinical.
The effects of curvature and thickness of cornea-based structures assessed by finite element modeling and optical coherence elastography Zhaolong Han,
Evaluation of Corneal Tomography in Primary Pterygium Sahil Goel, MD (Presenting Author), Murugesan Vanathi MD *The authors have no financial interests.
The effect of corneal edema on intraocular pressure measurements after phacoemulsification surgery Ilker Eser M.D. 1 Arzu Taskiran-Comez M.D. 1 Baris Komur.
Ahmed El-Massry, M.D. Professor of Ophthalmology - Faculty of Medicine University of Alexandria Egypt long-Term Results of Corneal Biomechanical Changes.
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Comparative biomechanical analysis of combined treatments for keratoconus M. A. del Buey 1, E. Lanchares 2, J. A. Cristóbal 1, B. Calvo 2, M. Doblaré 2.
Rio de Janeiro Corneal Tomography and Biomechanics Study Group CONCOMITANT KERATOCONUS AND FUCHS DYSTROPHY: TWO DISEASES IS BETTER THAN JUST ONE? Dr. Ambrósio.
BIOMECHANICAL PROPERTIES OF THE CORNEA IN PSEUDO-EXFOLIATION SYNDROME Aylin Kılıç Ertan, MD Özgür Bilen, MD Kudret Eye Hospital, Ankara, Turkey There is.
Poster# P36 Comparison of Techniques of Measuring Anterior Chamber Depth and Corneal Curvature in Indian Eyes Sujata Das, MS, FRCS Anjula Kumari, B.Optom.
Intrastromal Ring Segments for Keratoconus: A Retrospective Review Brad Feldman MD, Alan Carlson MD, Terry Kim MD, Natalie Afshari MD, Ricardo Santaella.
Iwona Helemejko, MD 1; D. Robert Iskander, PhD2
Intraocular pressure & tonometry
Characteristics of Primary Angle-Closure Glaucoma Patients with Normal Intraocular Pressure at the First Visit Won Hyuk Oh1, Bum Gi Kim1, Joo Hwa Lee2.
55th ASMR National Scientific Conference
Influence of UVA-Riboflavin corneal collagen cross-linking on biomechanical properties of keratoconic eyes David Zadok MD, Yakov Goldich MD, Yaniv Barkana.
Date of download: 10/26/2017 Copyright © ASME. All rights reserved.
Comparison of Single-Scheimpflug and Dual-Scheimpflug Pachymetry Measurements and Effect of Decentration World Cornea Congress VI April 7-9, 2010.
Hôpital Ophtalmique Universitaire
Comparison of corneal powers obtained from four different devices
Effects of corneal collagen crosslinking on Ocular Response Analyzer waveform-derived variables in keratoconus and post-LASIK ectasia Spatial treatment.
Keratometric Changes in Noninflammatory Corneal Ectasic Diseases After Intraocular Pressure Reduction Authors has no financial interest. Renata T Kashiwabuchi,
Associate Professor of Ophthalmology
Vicente J. Correa-Gomez MD, Guillermo Tapia MD, Oscar Macias Manuel MD, Alejandro Navas Perez MD, Gilberto Islas MD, Tito Ramírez-Luquin MD, Enrique O.
Federal University of São Paulo, Brazil
Bruno Valbon, Ana Caiado, Ricardo Louzada, Renato Ambrosio Jr *.
Sun Woong Kim, M.D.1, Hae Jung Sun, M.D.1,
13.3 Images in Lenses.
Yakov Goldich MD,Yaniv Barkana MD, Isaac Avni MD, David Zadok MD,
Corneal Biomechanics after Penetrating Keratoplasty and Descemet’s Stripping Automated Endothelial Keratoplasty Samer Hamada MRCOphth FRCS(Ed)1,3 Louai.
Khairidzan Mohd Kamal MD
Jun Her MD. PhD, Sung-wook Kim MD, Jae-hwan Ahn MD
EFFECT OF CORNEAL THICKNESS ON SELECTIVE LASER TRABECULOPLASTY
Presentation transcript:

Corneal Biomechanical Assessment using Dynamic Ultra High-Speed (UHS) Scheimpflug Imaging and Non-Contact Tonometry (NCT) Diogo L. Caldas, MD Isaac C. Ramos, MD Renato Ambrósio Jr, MD, PhD Michael W. Belin, MD, FACS Cynthia J. Roberts, PhD Dr. Ambrósio, Dr. Belin and Dr. Roberts are consultants for Oculus Optikgeräte GmbH (Wetzlar, Germany)

Purpose To present CorVis ST (Oculus, Wetzlar) - a new clinical tool for assessment of corneal biomechanical properties and intraocular pressure (IOP) To test its capability to distinguish different materials based on their deformation characteristics Oculus CorVis ST Ultra High-Speed (UHS ST) Scheimpflug Technology: 4,330 frames/sec 8mm horizontal coverage NCT symmetrically metered air pulse

Methods: Contact Lens Experiment Three hydrophilic contact lenses: TAN-40: 62% Hydroxyethylmethacrylate (525µm thick) TAN-58: 42% Methylmethacrylate (258µm thick) TAN-G5X: 41% Hydroxyethylmethacrylate/Glycolmethacrylate, (550µm thick) Mounted on a water chamber with adjustable pressures

Methods: Contact Lens Experiment Pressures from 0 to 70mmHg (5mmHg intervals) 6 measurements for each lens at each pressure level MAIN OUTCOME MEASURES Deformation amplitude (DA- highest concavity displacement of the apex) Corneal speed and curvature Time for the highest concavity momentum Curvature at highest concavity momentum

Response is influenced by the Pressure at the Chamber Contact Lens Experiment TAN 40 at 0mmHg adjusted chamber pressure Contact Lens Experiment TAN 40 at 20mmHg adjusted chamber pressure Contact Lens Experiment TAN 40 at 60mmHg adjusted chamber pressure

Deformation Amplitude X Pressure (hydrostatic head)

Results: Deformation amplitude DA: Highest concavity displacement of the apex Contact Lens Experiment Measurements at 20mmHg adjusted IOP Coef. Of Variability < 5%

Response is influenced by the Pressure at the Chamber TAN 40 at 0mmHg adjusted chamber pressure TAN 58 at 60mmHg adjusted chamber pressure

Results: Highest Concavity Time of highest concavity momentum (HC Time) Curvature at highest concavity momentum (Cur HC)

Conclusions from Contact Lens Experiment Dynamic UHS Scheimpflug corneal imaging with NCT enables to differentiate physical properties in test objects based on deformation response The response is influenced by the material properties and by chamber pressure The inspection of the actual deformation process provides further detailing for corneal characterization Relevance for Cornea, Refractive Surgery, Glaucoma…

Thank You ! diogolcaldas@gmail.com