Time-of-flight with LAPPD MCP-PMTs & MRPC

Slides:



Advertisements
Similar presentations
Wang Yi, Tsinghua University SoLID collaboration meeting, Status of MRPC-TOF 1 Wang Yi Department of Engineering Physics Tsinghua University,
Advertisements

Development of high rate RPCs Lei Xia Argonne National Laboratory.
1 MRPC detector as polarimeter for dEDM Characteristic of detector Time Resolution Electronics Possible R&D Plans D. Babusci, A. Ferrari, P. Levi Sandri,
The Factors that Limit Time Resolution in Photodetectors, Workshop, University of Chicago, April 2011 What is known experimentally about timing determinants.
Status of MRPC-TOF Wang Yi Department of Engineering Physics Tsinghua University, Beijing, China 1.
HCAL with Resistive Plate Chambers José Repond Argonne National Laboratory Presented at the Chicago Linear Collider Workshop January 7-9, 2002.
Large Area, High Speed Photo-detectors Readout Jean-Francois Genat + On behalf and with the help of Herve Grabas +, Samuel Meehan +, Eric Oberla +, Fukun.
Preparation of MTD production Yongjie Sun Center of Particle Physics and Technology University of Science and Technology of China.
New MRPC prototypes developed in Tsinghua Unversity Huangshan Chen (Tsinghua Unversity)
Mauro Raggi Status report on the new charged hodoscope for P326 Mauro Raggi for the HODO working group Perugia – Firenze 07/09/2005.
PHENIX RPC in China Li Ye Shouyang Hu Xiaomei LI China Institute of Atomic Energy
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Photodetection EDIT EDIT 2011 N. Dinu, T. Gys, C. Joram, S. Korpar, Y. Musienko, V. Puill, D. Renker 1 Micro Channel plate PMT (MCP-PMT) Similar to ordinary.
Examples of Time of Fight Detectors. Variety of methods for measuring time it takes for a particle to travel through a medium A time of flight (TOF) detector.
RPC R&D status in Bucharest (JRA12-I3HP) Mihai Petrovici - CBM-Meeting, GSI, March 1,2006 Short history SMSMGRPC – Glaverbel Glass Prototype –Construction.
Third workshop on hadron physics in ChinaWang Yi, Tsinghua University A conceptional design of SOLID-TOF Outline: Development of low resistive glass and.
GEM: A new concept for electron amplification in gas detectors Contents 1.Introduction 2.Two-step amplification: MWPC combined with GEM 3.Measurement of.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
TPC R&D status in Japan T. Isobe, H. Hamagaki, K. Ozawa, and M. Inuzuka Center for Nuclear Study, University of Tokyo Contents 1.Development of a prototype.
Prototypes of high rate MRPC for CBM TOF Jingbo Wang Department of Engineering Physics, Tsinghua University, Beijing, China RPC-2010-Darmstadt, Germany.
PHENIX TOF Upgrade Project Tatsuya Chujo for the PHENIX Collaboration.
Mariana Petris, CBM Collaboration Meeting, October 13-18, 2008, Dubna Mariana Petris, NIPNE - Bucharest C B M In-Beam Test Results of the Pestov Glass.
Time of Flight Detectors at RHIC Time of Flight Measurements at RHIC  TOF detector as a PID devices  PHENIX-TOF and BRAHMS-TOF PHENIX Time-of-Flight.
长读出条 MRPC 性能研究 孙勇杰 Key Laboratory of Technology of Particle Detection and Electronics, USTC-IHEP, CAS Center of Particle Physics and Technology, USTC.
July 8, 2003V.Ammosov GSI, CBM meeting1 RPC TOF system for HARP experiment (Applicability for CBM) Vladimir Ammosov Institute for High Energy Physics Protvino.
MRPC Beam GSI Yongjie Sun University of Science and Technology of China.
Slide 1Crispin Williams INFN BolognaALICE TOF The ALICE-TOF system 1. Quick overview of the TOF system that we are building 2. The Multigap Resistive Plate.
ITEP participation to the CBM TOF project ITEP ALICE - TOF group CBM – Russia meeting at ITEP, Nov 5 th, 2004.
Test results of Multi-gap RPC Test Chambers for a Digital HCAL  Geometrical design  Test setup  Signal: avalanche mode and streamer mode  Comparison.
A Hadron Calorimeter with Resistive Plate Chambers José Repond Argonne National Laboratory CALOR 2006, Chicago, June 5 – 9, 2006.
Christian Lippmann (ALICE TRD), DPG-Tagung Köln Position Resolution, Electron Identification and Transition Radiation Spectra with Prototypes.
7 th Workshop on Hadron Kunshan Univ Wang Yi, Tsinghua University 1 Conceptual design of SoLID-TOF and aging test Outline: Conceptual design.
Status of the Front-end-Electronics based on NINO ASIC for the Time-of-Flight measurements in the MPD V. A. Babkin, M.G. Buryakov, V. M. Golovatyuk, S.
NSS2006Shengli Huang1 The Time of Flight Detector Upgrade at PHENIX Shengli Huang PHENIX Collaboration Outlines: 1.Physics motivations 2.Multi-gap Resistive.
2013 核电子学 ASIC 技术研讨会, 2013/10/14 基于电流模的 MRPC 探测器读出 ASIC 研究 报告人:周新 指导老师:邓智.
R & D Status report on INO Naba K Mondal Tata Institute of Fundamental Research Tata Institute of Fundamental Research Mumbai, India.
SIMULATION STUDIES ON THE EFFECT OF SF 6 IN THE RPC GAS MIXTURE Mohammed Salim, Aligarh Muslim University, INDIA Presented by Satyanarayana Bheesette,
The ALICE-TOF system 1. Quick overview of the TOF system that we are building 2. The Multigap Resistive Plate Chamber -what is it? 3. Difference in.
UIUC mRPC R&D o Introduction & Physics Motivation o RPC design & assembly o Cosmic Ray Muon Test o Beam Test with BNL (lead), Howard University, CCNY,
Status of BESIII and upgrade of BESIII
Performance studies of a single HV stack MRPC prototype for CBM
Beam detectors performance during the Au+Au runs in HADES
Development of beam tracking detector using MicroChannel Plate(MCP)
Results achieved so far to improve the RPC rate capability
Sensitivity of Hybrid Resistive Plate Chambers to Low-Energy Neutrons
IFR Status Summary W. Baldini on behalf of the IFR Group
Recent DHCAL Developments
Scintillation Detectors
CMS muon detectors and muon system performance
BoNuS: Radial-Drift TPC using Curved GEMs
GRPC activity for EuDHCAL in IHEP-Protvino
Multigap Resistive Plate Chambers (MRPC)
PHENIX RPC R&D EFFORT Beau Meredith
PADI for straw tube readout and diamonds for MIPs and for high precision tracking beam test – Jülich, Feb Jerzy Pietraszko, Michael Träger, Mircea.
Gaseous Beam Position Detectors, with Low Cost and Low Material Budget
José Repond Argonne National Laboratory
Multigap Resistive Plate Chambers for EAS study in the EEE Project
Conceptual design of TOF and beam test results
STAR TOF MRPC Mass Production & Q.C. (USTC)
Progress on the development of a low-cost fast-timing microchannel plate photodetector Junqi Xie1, Karen Byrum1, Marcel Demarteau1, Joseph Gregar1, Edward.
MRPC -High Time Resolution Detector R&D at USTC CHINA Chen, Hongfang 2001/Oct. Oct.2001, Beijing MRPC,USTC.
Update on SoLID-TOF Wang Yi Outline: Conceptual design of SoLID-TOF
General Update Jian-ping Chen, JLab SoLID Collaboration Meeting
Pre-installation Tests of the LHCb Muon Chambers
High time resolution TOF for SoLID
Upgrade of the GlueX Spectrometer for Physics with Strange Final States Nuclear Physics Yi Qiang Nov. 13, 2011.
High time resolution TOF for SoLID
PID detector on BESIII Nov 27th, 2007 Yuekun Heng IHEP
Performance test of a RICH with time-of-flight information
A DLC μRWELL with 2-D Readout
Presentation transcript:

Time-of-flight with LAPPD MCP-PMTs & MRPC Junqi Xie, Mickey Chiu on behalf of Detector R&D group Argonne National Laboratory Brookhaven National Laboratory SoLID Collaboration Meeting, May 6-7, 2016

Glad to join SoLID collaboration to contribute Junqi Xie Assistant Physicist Detector R&D group Argonne National Laboratory Mickey Chiu Physicist Director of Operations, PHENIX Brookhaven National Laboratory We are also collaborating in particle identification detectors for sPHENIX and EIC

Time-Of-Flight Detectors Goal(s): - Initial plan is to have MRPC <100 ps for pion identification up to 2.5 GeV/c - Above 2.5 GeV/c Heavy Gas Cherenkov for pion identification - Kaon identification more demanding requirements: better separation and higher in momentum requires <30 ps resolution with the SoLID SIDIS environment - Tsinghua U: upgrade/improved hardware could make MRPC intrinsic to <20 ps need readout system upgrade Expanding collaboration effort - Joint effort with EIC R&D project, Micky Chiu joined SoLID EIC R&D achieved <20 ps on bench test, lab test now options for readout system - Option with (LA)PPD detector R&D, Junqi Xie joined SoLID See Junqi’s talk for details J.P. Chen’s slide

Option 1: MCP-PMTs Micro-channel plate (MCP) replacing traditional dynode Thin plate with micro pores (pore size < 30 μm, thickness ~ 5 mm) Each pore behaves like an electron multiplier E field

Large Area Picosecond PhotoDetector (LAPPD) The LAPPD project reinvents photodetectors using transformational technologies. Goals: low-cost, large-area (20 cm x 20 cm), picosecond-timing Applications: picosecond timing, millimeter spatial resolution on large-area High energy physics: optical TPC, TOF, RICH Medical imaging: PET scanner, X-ray imaging devices National security: Detection of neutron and radioactive materials

Tube production MCP & Resistive Grid Spacer Stack Glass LTA Completed Tube 11 tubes are produced Jun. – Dec. 2015 Assembling a pre-baking chamber to produce 1 tube/week Go to ”Insert (View) | Header and Footer" to add your organization, sponsor, meeting name here; then, click "Apply to All"

Key performances Signals / frequency components Spectra response rise time goal 20% 18% Signal bandwidth up to1.3 GHz

Key performances 108 Gain as high as 7X107 Time resolution overall ~35 ps, TTS <20 ps Laser start time jitter: laser ~30ps Rate capability: > 75KHz/cm2/s 107 106 Overall time resolution Rate capability 100 ps 75KHz/cm2/s 50 ps 30 ps Go to ”Insert (View) | Header and Footer" to add your organization, sponsor, meeting name here; then, click "Apply to All"

Future development path Optimization in geometry for fast timing, magnetic field immunity Pad readout Background testing at JLab for Solid …… SoLID, sPHENIX, EIC Feedback from users helps to improve the design Today TARDIS Cryogenic user? Have a plan. Small-scale adoption in various experiments Go to ”Insert (View) | Header and Footer" to add your organization, sponsor, meeting name here; then, click "Apply to All"

Option 2: Multi Gas Gap Resistive Plate Chamber (MRPC) Invented in 1996, Crispin Williams et al, CERN → New generation of TOF detector Cost effective compared to scintillator + PMT based TOF Easy to build a large area detector Free from the magnetic field effect Essential Concepts 130 mm active area 70 mm Floating resistive plates in between electrodes Space charge limits avalanche growth to be below streamer transition Recombination cuts ionic charge residual in the gas gap Differential readout reduces noise and is helpful to obtain good time resolution. Basic slide on mRPC. Working, ~ 80 ps time resol. : ALICE, STAR, PHENIX, FOPI Achieved for high rates (20 kHz/cm2), ~80 ps time resol: CBM Aiming for 10 ps time resol. : EIC Aiming for 10 ps AND high rates? : SOLID

Improving Resolution Down to 10 ps? Crispin Williams et al, NIMA 594 (2008) 39– 43 Gas gap width : 160um BNL&UIUC Prototype, eRD14, 2015 Gas gap width : 105um PCB Glass Gas gap Narrower gap width → fast charge dominant in the induced signal → Better timing resolution Efficiency recovered by adding more gas gaps (as well as more signal) MRPC ( C. Williams et al. ) MRPC ( UIUC & BNL) Gas Gap Width 160um (fishing line) 105um (diameter of fishing line) # of Gas Gaps 4 stack x 6 gas gaps = 24 4 stack x 9 gas gaps = 36 # of thin glass layers 4 stacks x 5 layers = 20 (250um thick glass) 4 stack x 8 layers = 32 (210um thick glass) Preamplifier Differential type, NINO chip (3GHz bandwidth) LMH6554 2.8-GHz + Evaluation Board TDC and DAQ Oscilloscope (Sampling speed of 10Gs) DRS4-V5(5Gs) + PC Time resolution 30 ps with cosmic ray/ 16 ps at T10 beam test CERN Cosmic ray test / Beam halo test at COMPASS Main points are that making more gaps and thinner gaps will improve the timing resolution. We compare here to the mRPC built by C. Williams (parameters are on the left), and to that built by us for eRD14. Main differences are that we use 105 um gaps (vs 160), and we also have 36 gaps vs 24.

eRD14 Glass MRPCs Gas chamber in the cosmic ray test stand at UIUC Differential Preamp. TI, LMH 6881 2.8GHz bandwidth 28 v/v MRPC1 MRPC2 Here is a picture of our setup, including our test readout system (TI differential preamp and DRS4 eval board). Major work would need to be done in making a custom readout for any experiment, such as SOLID (also the same case for MCP-PMTs). Waveform Analyzer (DRS4-V5) 5GHz sampling speed Gas Input & Output HV : 20kV ( +11kV, -11kV)

eRD14 mRPC: Efficiency and Time Resolution Cosmic rays 22kV Efficiency [ns] MRPC1- MRPC2 C. Williams CERN, 2010 Preamp : NINO, 10 GHz, Oscilloscope Cosmic rays 22kV Our efficiency, correlation plot, and time resolution plot (starting from upper left). Lower right is the published result from Crispin Williams, so you can compare his ~20 ps with our ~18 ps. 25.4ps / √2 ~ 18ps MRPC1- MRPC2 [ns]

Use different material than glass (eg Mylar)? 48 gas gaps! Glass mRPC Mylar mRPC Here I argue why going to Mylar replacing glass should produce a better performing mRPC… The basic idea is that using thinner material such as mylar, you can make the signals closer to the pickup cathodes, or you can create more gas gaps which creates more signal. The mylar we created for the FNAL beam test had 48 gas gaps, compared to 36 for the eRD14 glass one, and 24 for the one built by Crispin Williams. One way to improve fast signal is to bring signal closer to pickup strips, or have more gaps Thinner glass gets very expensive (and starts to become flexible) Use Mylar instead? Can then replace 210 um glass with 125 um Mylar However, rate capability should be bad? Mylar has much higher volume resistivities, 1019 Ω-cm2 Possible major technical challenge: create flat mylar layer separated from next by ~100 um (solved?)

Thanks for your attention! Summary The Argonne MCP photodetector program has been highly successful, benefiting from advances in different disciplines. The success of the photodetector program brings in lots of interests from many areas of science: TOF at collider, HEP neutrino experiments, medical imaging, nuclear physics experiments, national security… Sent out devices to early users for evaluation and incorporation to experiments. Progress has been made on MRPC for <20ps timing resolution. Different material other than glass is planned for even faster MRPC design. Thanks for your attention!

Backup Slides

First Signals from the 3D Printed MRPCs Two 3D printed gas gap MRPC assembled Signals 2 stacks, 10 gas gaps, 0.3mm gas gap width (No need to wire fishing lines) Trigger bias Signals captured at COMPASS hall Not enough time to setup 3D MRPC properly for data taking before the COMPSS beam was end Expected the first time resolution results in the beam test at Fermilab 2016!

Stacking Glass with Fishing Line 105um diameter of fishing line Stacking glass plates and fishing lines Uniform gas gaps Between glass plates 4 stacks : 36 gas gaps