Pacemakers and Devices – Interactive Session

Slides:



Advertisements
Similar presentations
Appendix E Pacemakers Gail Walraven, Basic Arrhythmias, Seventh Edition ©2011 by Pearson Education, Inc., Upper Saddle River, NJ.
Advertisements

Dual Chamber Temporary Pacing Operations & Troubleshooting
By Dr.Ahmed Mostafa Assist. Prof. of anesthesia & I.C.U.
Temporary Pacemakers Karim Rafaat, MD.
Basic Overview ECG Rhythm Interpretation
The electrocardiogram (ECG or EKG)
The Very Basics of Pacing Glenn Estell Medtronic Pribcipal Clinical Specialist.
Modes of Pacing Seoul National University Hospital
EKG Monitoring.
for internal use only Evidence Based Medicine The Need to Avoid Unnecessary Ventricular Stimulation.
Pacemakers and Implantable Cardioverter-Defibrillators
Appendix E Pacemakers Gail Walraven, Basic Arrhythmias, Sixth Edition ©2006 by Pearson Education, Inc., Upper Saddle River, NJ.
Artificial Pacemakers and Anesthesia
Juan Camilo Diaz Cardiac Pacemakers.
Pacemaker Follow-up Alpay Çeliker MD. Hacettepe University Department of Pediatric Cardiology 3rd International Summer School on Cardiac Arrhythmias, 9-12.
Single Chamber Temporary Pacing Operations & Troubleshooting.
Pacemakers and Implantable Cardioverter Defibrillators Chapter 10
1 Lecture Notes Chapter 19 Electrocardiogram and Cardiac Arrhythmias Copyright © 2007, 1998 by Mosby, Inc., an affiliate of Elsevier Inc.
Fast & Easy ECGs – A Self-Paced Learning Program
Basic Cardiac Pacing Claire Regan MSc Chief Cardiac Physiologist UHSM 2009.
Mar 20, 2008 ECG Rounds Yael Moussadji, R4. Case 1.
Pacemakers.
ECG Basics.
Device and Antiarrhythmic Drugs: Advantages and Pitfalls Teresa Menendez Hood, M.D.
ECG in Pacemaker Malfunction
Analyzing the Electrocardiogram
1. CARDIOVASCULAR SYSTEM ELECTROCARDIOGRAM (E.C.G.) LECTURE - 5 DR. ZAHOOR ALI SHAIKH 2.
Electrocardiogram (ECG/EKG)
Supparerk Prichayudh M.D
Pacemaker ECGs Dr. K Chan Ruttonjee and Tang Shiu Kin Hospitals
Palpitations and Common Arrhythmias J. Philip Saul, M.D. West Virginia University Morgantown, WV.
Arrhythmias ED SHO TEACHING C Brown, August 2015.
Basics of Pacemaker Functioning
Tachykardie / bradykardie
Heart Blocks and Pacing
ECG RHYTHM ABNORMALITIES
Rhythm recognition Workshop
CARDIAC PACEMAKER Ms. Saranya N 27-Feb-18 Cardiac Pacemaker.
Questions included for Critical Care Competency Day
Electrical Properties of the Heart
CODE BLUE MANAGEMENT Quick ECG Interpretation
Objective 12 Electrocardiograms
Temporary Pacemakers.
Instructor Erin Butler RN
Electrocardiography (ECG) EKG
From: Pacemaker Malfunction
Cardiac Cycle, Arteries, Cardiomegaly, Sinus Rhythm
Resident Survival Skills
Pacemaker II Lecture (6).
Atrial depolarization, initiated by the SA node, causes the P wave. Q
From: Pacemaker Malfunction
5 The Electrocardiogram.
Pacemakers and Implantable Cardioverter-Defibrillators
Cardiovascular System Block Cardiac Arrhythmias (Physiology)
PACEMAKER Yoga Yuniadi
ECG Advanced Basics for Interns - Arrhythmias
ARRHYTHMIA DR MANSOUR ALQURASHI
ECG Basics.
ECG The Basics And Beyond
Pacemakers.
ECG Rhythm Interpretation
Chapter 35 part 2 Cardiac Disorders 1.
ECG Rhythm Interpretation
EKGs and Pacemakers Cooper University Hospital
What is the QRS axis? Is it normal or abnormal?
ECG Rhythm Interpretation
The Electrical Management of Cardiac Rhythm Disorders Tachycardia Brady Therapy.
Pitfalls of pacemaker detection of ventricular high-rate events
Haseeb Jafri, MD, Alan Cheng, MD, FHRS  HeartRhythm Case Reports 
ECG Rhythm Interpretation
Presentation transcript:

Pacemakers and Devices – Interactive Session Sriram Rajagopal, Southern Railway Hospital, Perambur,Chennai

Pacemakers and Devices Basics of Pacing and devices Practical and day- to- day problems

Pacemakers and Devices What is “unipolar” pacing and “bipolar” pacing ?

Pacemakers and Devices What is VVI pacing ? What is DDD pacing ? Modes of pacing – 3 and 5 letter codes First letter – Chamber Paced -A , V or both (D) or none (O). Second – Chamber Sensed- A , V or both (D) or none (O). Third- Response to Sensing – inhibition (I) or triggering(T) or both (D) Fourth - Rate adaptive pacing ( R ) Fifth - Multisite pacing (A),(V) or (D)

Pacemakers and Devices What is pacing threshold ? What is Strength-Duration Curve ?

Pacemakers and Devices Explain the concepts of Battery capacity, voltage, Current flow and Resistance in pacing?

Pacemakers and Devices What is Pacemaker Mediated tachycardia ?

Pacemakers and Devices What is pacemaker syndrome ? The term “pacemaker syndrome” refers to a combination of symptoms and signs related to adverse hemodynamic consequences of pacing (usually occurring in single chamber ventricular pacing). Usually due to loss of AV synchrony

Pacemakers and Devices How can one adjust “ Pacing Threshold” ? Pacing threshold CANNOT be adjusted or programmed Only the output of the pacemaker can be adjusted i.e Pulse amplitude and Pulse width

Pacemakers and Devices What is meant by fusion ? What is pseudo- fusion ? Fusion is said to occur when both intrinsic and pacing induced depolarization contribute to the electrical activation of the chamber being paced. In Pseudofusion the pacing stimulus does not in any way contribute to the depolarization of the chamber and hence the QRS morphology will be identical to an intrinsic beat, but will have a pacing stimulus artifact superimposed on it .

Pacemakers and Devices Fusion : 1st QRS is paced and 3rd and 4th are intrinsic rhythm. Second is intermediate in morphology and is preceded by stimulus artefact

Pacemakers and Devices 1st, 2nd and 5th are paced QRS complexes, 4th is intrinsic QRS. 3rd is similar to intrinsic QRS ( repolarization also similar) but initial QRS deformed by stimulus artefact. Pseudo-fusion.

Pacemakers and Devices If the sensitivity setting is changed from 2.5 to 5mV , Is the pacemaker “More sensitive” or “Less sensitive”? ?

Pacemakers and Devices Recording from Holter in a patient with CHB who received a single chamber pacemaker 2 years ago (VVIR 60/120) What is the interpretation ?

Pacing and D evices Interpret the tracing : Hysteresis function allows a longer “escape interval” from a Sensed event to the next paced event. Pacing interval is Constant

Pacemakers and Devices 60 year old lady. VVI pacing system implanted 12 years ago for Symptomatic complete heart block. VVI 70/min. Hysteresis of 20bbpm. Recent onset giddiness with syncope. Normal sensing, no pacing ( provided battery not completely dpleted). ECG without magnet application

Pacemakers and Devices Rhythm strip with magnet application

Pacemakers and Devices

Pacemakers and Devices

Pacemakers and Devices How do you identify the type and make of pacemaker in a Patient with no records and a PG with depleted battery ?

Pacemakers and Devices Name some recent advances in pacing technology . Remote Monitoring Leadless pacemaker Battery- less pacemaker Biological pacemaker

Pacemakers and Devices What are the types of dys-synchrony to be addressed in CRT?

Elements of Cardiac Dyssynchrony L Atrio- ventricular Inter-atrial Intra-atrial Synchrony Intra-Left ventricular R Atrio- ventricular Inter- ventricular Cazeau, et al. PACE 2003; 26[Pt. II]: 137–143

Pacemakers and Devices Unexplained Syncope, severe LV dysfunction and Idiopathic Dilated Cardiomyopathy is 1. Class I indication for ICD 2. Class II a indication for ICD e 3. Class II b indication for ICD 4. Class III indication for ICD Amiodarone D

Pacemakers and Devices What are inappropriate shocks? What are the common causes ?

Pacemakers and Devices Shocks delivered for “arrhythmias” other than intended ventricular arrhythmia Sinus tachycardia, atrial fibrillation, SVTs , other electrical signals perceived as VT.

Pacemakers and Devices Adaptive Dynamic Sensing is used in ICDs for 1. To identify VF 2. To differentiate AF from VF 3. To prevent T wave sensing 4. To sense Atrial Tachycardia C

Pacemakers and Devices Which of the following is NOT a cause for arrhythmic storm In a patient with an ICD 1. Deteriorating Heart failure 2. Elelctrolyte Imbalance 3. Myocardial Ischemia 4. Amiodarone D

Pacemakers and Devices The Algorithm used to differentiate Atrial Fibrillation from Ventricular Tachyacrdia in ICDs is 1. Interval Stability 2. Interval Rhythm Analysis 3. P-R logic 4. QRS duration analysis A

Thank you for your kind attention !

Pacemakers and Devices Rhythm strip recorded from a patient with a VVI pacemaker. Interpret the tracing . Hysteresis – allows a longer “escape” interval after a sensed Event till the next paced event .

Pacemakers and Devices What is Over- sensing ? VVI Below the top channel (surface ECG ) is the marker channel (showing what pacemaker is “doing”).Sensing is seen to occur even without any surface ECG activity.