Electrical Risks, Safety and Solutions for Older Homes

Slides:



Advertisements
Similar presentations
Introducing Electricity and Electrical Safety
Advertisements

Using Electricity in the Home
Electrical Risks, Safety and Solutions for Older Homes
UNIT 31 HOME ELECTRICAL SYSTEM
Electrical wiring presented by Łukasz Wiergowski and Mariusz Cyganek Electrical wiring in general refers to insulated conductors used to carry electricity,
Electrical Safety.
Electrical Safety Electrical Safety In and Around the Home NUECES COUNTY Risk Management Department.
Electrical Installation
Electrical Safety Basic Electrical Safety Rafael Coll, Environment Safety and Health Section Health& Safety Group Ext Pager: (630)
Electrical Fire Safety Fire Prevention Week 2012 Electrical Safety Foundation International.
4/30/2015 AFCI 9/01/07 Rev 5 1 Arc Fault Circuit Interrupters For NEMA Field Reps.
Inspecting Electrical. Inspection Includes:  Service entrance & masthead  Main panel and subpanels (if any)  Branch circuit wiring  Junction boxes,
CHEM 521 Safety Presentation. Hazard Symbols You Must Know.
1 OFFICE ELECTRICAL SAFETY Environmental Energy Technologies Division (EETD) On the Job Training August 12, 2013.
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
EET Survey of Electronics
Electrical Power Systems
©2008 The McGraw-Hill Companies, Inc. All rights reserved. Electronics Principles & Applications Seventh Edition Arc Fault Circuit Interrupters Charles.
Electrical Principles and Wiring Materials
Circuit Protection Electrical circuits require protection to prevent fire or electrocution in the event of a fault. There are two main types of circuit.
Hazard - Inadequate Wiring
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
Purpose Power lines Equipment Assured Grounding GFCI Conclusion.
BUILDING TRADE SAFETY ELECTRICAL SAFETY.
Electrical Principles and Wiring Materials
Electrical Safety.
Hazard Identification at Home. Ground Fault Circuit Interrupters (GFCI’s)  GFCI’s provide protection by turning off the power before a shock occurs 
ELECTRICAL HAZARDS Electricity is an essential of modern life Some work directly with electricity (Engineers, circuit assemblers) Some work indirectly.
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
Arc Fault Circuit Interrupters. Residential fires caused by electricity occur more than 40,000 times each year in the U.S. alone. 40% are due to arcing.
Electrical Principles and Wiring Materials Unit #31.
Basic Electrical Safety
Electrical Principles and Wiring Materials Unit #31.
35 Electric Circuits In a parallel circuit, each device operates independent of the other devices. A break in any one path does not interrupt the flow.
Keeps heat indoors in winter and outdoors in summer – means lower heating and cooling bills Rated by it’s R-value. The greater the R- value the better.
Fire Prevention “ Cover the Bases & Strike Out Fire”
Electrical Safety and Electrical Safe Work Practices EHS Course #525 Reference EHS Electrical Safety Procedure
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials Original Power Point Created by Casey Osksa Modified by Georgia Agricultural Education Curriculum Office June.
ELECTRICAL FIRES CAN BE PREVENTED! By PowerCheck.
Electricity what doesn’t kill you…. really, really hurts.
STAY SAFE!. ELECTRICAL FIRES ARE ALL TOO FREQUENT! -Homes over 40 years of age are at increased risk of fire. -The fire hazards are usually not recognized.
By: Mr. Brock.  Electricity- Source of energy that can be easily converted into light, heat or power  Ampere (Amp)- Unit of measure of the rate of flow.
Holiday Safety 10-4 training 10 Slides, 4 minutes Lehigh/Hanson Region West Safety and Health.
+ Electric Circuits Parallel Circuits and Diagrams.
ELECTRICAL WIRING WIRING BASICS Written by Bobby Joslin
CHEM 421 Safety Presentation. Hazard Symbols You Must Know.
Electrical Repair and Maintenance
Electrical Safety Basic Electrical Safety. Electrical Safety  Course not designed to teach you to work on electrical equipment. Basic Electrical Safety.
Electrical Principles and Wiring Materials
Making Circuits Safe SNC1P1 Findlay.
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials
Circuit Protection Unit 9.
Basic Electrical Safety
Conductors of electricity
"Don't Get Amped Up! Electrical Safety to Keep Your Team Grounded!"
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials
Conductors of Electricity
Personal Protective Equipment
AFCI Protection: AFCI Receptacles and the NEC
Outlet Branch Circuit Arc Fault Circuit Interrupter (OBC AFCI)
Domestic Electricity AIM: To understand the use of domestic electricity and safety features such as fuses, circuit breakers and the earth circuit
Basic Electrical Safety
Basic Electrical Safety
Fuses
Electrical Principles and Wiring Materials
Presentation transcript:

Electrical Risks, Safety and Solutions for Older Homes Presented by: PowerCheck Electrical Safety Services www.powercheck.ca September 2009

Older buildings: Higher risk!! As buildings age the risk of accidental electrical fire significantly increases. “The frequency of fires in residential electrical systems was disproportionately high in homes more than 40 years old” (CPSC, 1987). With an electrical check up by a qualified person, electrical fires will be prevented. © PowerCheck Electrical Safety Services 2009

What causes electrical fires? Electrical work done illegally, without electrical permits (aka. “Handyman tinkering”) accounts for the vast majority of electrical fires. Handyman tinkering is found rampant in older buildings. Handyman tinkering tends to accumulate over the years resulting in older buildings being particularly at risk. ALL TOO COMMON. These types of hazards are commonly found, independent of knob-and-tube replacement or service upgrade. © PowerCheck Electrical Safety Services 2009

WIRING HISTORY IN HOMES Knob and tube: pre-1950 Installed in nearly all homes built before 1950. Still present in most pre-1950 homes today. Designed for “two-prong” receptacles. Two-prong receptacle © PowerCheck Electrical Safety Services 2009

Knob and tube: Qualities Identification: Two single conductors Supported by porcelain knobs and tubes A well designed system: Heavy gauge conductors Spaced well apart All connections soldered Work seldom done by non-professionals knobs tubes Behind the walls, knob-and-tube wiring provides power for lights and receptacles throughout an older homes. © PowerCheck Electrical Safety Services 2009

© PowerCheck Electrical Safety Services 2009 Knob and tube: Hazards Original 2-prong outlets swapped for modern 3-prong: Hazard: NO GROUND PROTECTION Original lighting exchanged for recessed lighting (pot lamps) Hazard: INSULATION BREAKS DOWN Due to limited number of outlets: Hazard: DANGEROUS ADD-ONS ALL FIRE HAZARDS! In nearly all older homes, the original 2-prong outlets have been found swapped for modern 3-prong without the proper wiring, which falsely presents that the home has been rewired & outlets grounded. © PowerCheck Electrical Safety Services 2009

Knob and tube: Solutions Rewire: $20,000 or Have wiring checked by an electrical specialist: Vast majority of homes: Old wiring = Excellent condition! Therefore, GFCIs can provide the necessary ground protection: $20 each AN EXCELLENT SOLUTION! GFCI receptacle provides excellent ground protection. It disconnects the power if leakage to ground exceeds 5 mA. © PowerCheck Electrical Safety Services 2009

Knob and tube: Findings In 99% of homes built pre-1950: Knob and tube wiring is still live today Usually not visible due to new panel and finished basement. Knob-and-tube wiring is in excellent condition No need for expensive replacement, but: Original 2-prong outlets found swapped for modern 3-prong Falsely presenting that the homes have been rewired and outlets grounded. Cost to correctly bring these homes to LOW RISK: less than $500 RESULT: SAFE AND HAPPY CLIENTS! © PowerCheck Electrical Safety Services 2009

© PowerCheck Electrical Safety Services 2009 Wiring of the 1950s NEW cable and new method of wiring introduced 1950. Eliminated the need for knobs and tubes. Fire hazards remain No ground protection Not for recessed lighting Due to limited number of outlets: Dangerous add-ons still rampant Introduced in 1950 a new “twin cable”, called “NMD1”. Still for 2-prong outlets. It had cable temperature rating of 60 degrees. Not suitable for recessed lighting. © PowerCheck Electrical Safety Services 2009

© PowerCheck Electrical Safety Services 2009 Wiring of the 1960s NEW cable introduced in the 1960s provides ground protection. Modern grounded outlets become the standard. Fire hazards remain: Cable not suitable for recessed lighting Due to limited number of outlets: Dangerous add-ons still rampant Introduced in the late 1950s: “NMD3”. Same characteristics as NMD1 but provided ground protection: Still not suitable for recessed lighting. © PowerCheck Electrical Safety Services 2009

Wiring of the 1970s through to today NEW cables rated with higher insulation temperature become the standard. Suitable for recessed lighting. Fire hazards remain: Dangerous add-ons Due to the rapid rise in basement suites, kitchen renos and powering of garages: Unauthorized electrical work continues to thrive. This is encouraged with the proliferation of self-help guide books and easy access of electrical supplies. Modern wiring, NMD7 & NMD90 become the standard, but along with it comes “do-it-yourselfers”. © PowerCheck Electrical Safety Services 2009

© PowerCheck Electrical Safety Services 2009 Aluminum wiring: 1968 – 1974 In vast majority of homes built 1968 – 1974. Still present today in most homes built 1968 – 1974. Designed as a cost- effective solution due to the high price of copper during these years. An aluminum-rated receptacle was required with the installation of aluminum wire. © PowerCheck Electrical Safety Services 2009

Aluminum wiring: Hazards Aluminum wiring can be fine, but 2 concerns: Original aluminum-rated outlets do get loose in time HAZARD: LOOSE CONNECTIONS Original aluminum-rated outlets swapped for modern, non-aluminum-rated outlets HAZARD: CORRODED CONNECTIONS ALL FIRE HAZARDS! Original aluminum-rated outlets are commonly found swapped for modern, non-aluminum-rated outlets: Creates corroded connections. © PowerCheck Electrical Safety Services 2009

Aluminum wiring: Solutions Rewire: $20,000 or Have wiring checked by an electrical specialist: Vast majority of homes: Aluminum wiring = Not in good condition! Regular maintenance: Many authorities recommend regular maintenance every 15 years. Typical cost: ~$1000 “If home [with aluminum wiring] has not been checked since new, it is high time overdue” (NFPA). © PowerCheck Electrical Safety Services 2009

© PowerCheck Electrical Safety Services 2009 60-amp service Until the1970s nearly all homes had 60-amp service. 60-amp service is often not identified by home owners. Ask an expert for correct service size and acceptability. “Rated for 100 amps” 60-amp fuses, 60-amp service Old boxes often have the wording “Rated for 100 amps”. This refers to the box rating, not service size. © PowerCheck Electrical Safety Services 2009

Some examples: An over-rated circuit breaker… 15-amp circuit breaker 30-amp circuit breaker © PowerCheck Electrical Safety Services 2009

…can create over-heated conductors © PowerCheck Electrical Safety Services 2009

Sometimes found: No fuses!! Here client has replaced main fuses with metal bars, eliminating over-current protection, creating a fire hazard condition. This exact scene was found by PowerCheck in an older home in Vancouver earlier this year. Home was sent to us because of knob-and-tube wiring. © PowerCheck Electrical Safety Services 2009

Exposed electrical connections If connections become at all loose they will arc, easily igniting surrounding wall material. Exposed connections This scene was found in a older home in New Westminster by PowerCheck last year. Home was sent to us because of knob-and-tube wiring. © PowerCheck Electrical Safety Services 2009

No junction box behind electrical device If connections become at all loose they will arc, easily igniting surrounding ceiling material. Commonly found in older homes where electrical wiring was done by home-owner or unqualified person. Home was sent to us because of knob-and-tube wiring. © PowerCheck Electrical Safety Services 2009

Extension cords stapled to walls Staples put pressure on cord. Over time the cord insulation breaks down. The staple then creates a direct short across the wires, which can easily result in fire. staples Commonly found: This scene was found in a older home in Vancouver by PowerCheck this year. Home was sent to us because of knob-and-tube wiring. © PowerCheck Electrical Safety Services 2009

Detached service conductor support Due to tree branches, or rotting wood, the support for the service conductors breaks away from the house. This creates a perilous situation putting strain on electrical connections. Once they separate the conductors can flash, creating fire. Conductor support Electrical connections This scene was found in a older home in West-side Vancouver by PowerCheck last year. Home was sent to us because of knob-and-tube wiring. © PowerCheck Electrical Safety Services 2009

A PowerCheck Home Electrical Safety Assessment All of these preceding hazards were identified, precluding electrical fire because Client had had a PowerCheck Home Electrical Safety Assessment. A Home Electrical Safety Assessment prevents fires. It was the referral from the insurance company that got this assessment done. © PowerCheck Electrical Safety Services 2009

Not enough homes are checked: Baseboard heater in dangerous location Individuals installing electrical equipment without being thoroughly knowledgeable on the electrical code, can easily result in electrical fires. http://blog.cleveland.com/metro/2007/12/third_child_killed_by_shaker_h.html “Seven firefighters said the fire began about 1 a.m. near an electric baseboard heater. Three children died, ages 6, 2 and 14 months” (Cleveland News, Dec 5, 2007). © PowerCheck Electrical Safety Services 2009

PowerCheck statistics In 99% of homes built pre-1950: One or more electrical fire hazards were identified 99% due to handyman tinkering 99% had swapped 2-prong outlets for 3-prong Excluding swapping outlets from our criteria: 60% of homes pre-1950 had one or more electrical fire hazards present, almost all due to handy tinkering If home had secondary suite: 84% had one or more electrical fire hazards present © PowerCheck Electrical Safety Services 2009

Specific breakdown of risks Homes in general, pre-1950 Handyman tinkering Old age Electrical wire © PowerCheck Electrical Safety Services 2009

Homes with secondary suite, pre-1950 Handyman tinkering Electrical wire © PowerCheck Electrical Safety Services 2009

Probability of risk increases with age If all homes greater than 35 years were checked. We would catch 74% of homes with electrical fire hazards. Statistically old homes are more dangerous This is primarily due to the compounding effect of handyman tinkering, building-up over the years This is particularly noticeable in homes with secondary suites If we were to examine all houses pre-25 years we would identify the vast majority of dangerous homes Notes on data Values based on preliminary data from 150 homes examined to date With larger sample, values may vary from above, however clearly there is a trend © PowerCheck Electrical Safety Services 2009

A HAPPY CLIENT WITH A SAFE HOUSE BUILDS CUSTOMER LOYALTY How do we do it? Explaining to clients that we are working with them to assure their house is safe, has produced positive results: Clients have been cautious to have their home checked, but with the possibility of reduced premiums, have gone forward with the PowerCheck Home Electrical Safety Assessment. Of 600 clients, upon showing clients the identified hazards: 598 have said “it has been the best thing that they have ever done”. Clients have been grateful beyond belief that their insurance company assisted them to get their home correctly diagnosed. A HAPPY CLIENT WITH A SAFE HOUSE BUILDS CUSTOMER LOYALTY © PowerCheck Electrical Safety Services 2009