Determining the Occupant Load

Slides:



Advertisements
Similar presentations
2009 Edition – NFPA 101 Steve Hornyak, DAHC, CDT, FDAI
Advertisements

Classroom Safety. Fire & Life Requirements as per State Education Dept The following list relates to the classrooms and adjacent areas. They are provided.
OSHA Office of Training and Education
7 | Means of Egress (Life Safety Code)
MEANS OF EGRESS.
General Requirements Number of exits must be adequate Usually at least 2 exits must be available for evacuation More than 2 exits are required if the.
Occupancy Classifications and Loads
OSHA Regulations Part 1910 Subpart E
NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview
Means of Egress Talia Ordonez Alex Prodanov Margarita Binkin Team.
of NFPA 101 Life Safety Code 2000 Edition Means of Egress
DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.
Building CODES Arch 3011 Design Studio 1 Prof. Sargent Architecture Southern Polytechnic State University.
This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are the target.
of NFPA 101 Life Safety Code Administration Definitions General
Accessibility.  A building code is a set of rules that specify the minimum acceptable level of safety for buildings. The main purpose of building codes.
Michigan Department of Licensing and Regulatory Affairs Bureau of Construction Codes.
Night Club Retrofit N. J. A. C. 5:70 – 4. 7 Night Club Retrofit Objectives Define what is a night club What are the requirements under the Code Why.
This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are the target.
Subpart E Means of Egress.
Smoke Control Fire-Rated Stairwells Fireproofing of Structural Components Egress Lighting Fire-Resistive Construction Elements Fire and Smoke Dampers Emergency.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
FIRE DESIGN OF BUILDINGS VULNERABLE GROUPS. COMPONENTS OF FIRE building materials unattended stoves Loose electrical connections overloaded electrical.
Emergency Action Plans
Life Safety Assessing life safety of a building is a process of estimating the quality of security against fire and its effects. Life safety implies avoiding.
EGRESS AND FIRE PROTECTION
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
© 2012 Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code and the.
Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR To 29 CFR
Means of Egress and Fire Protection
NO EXIT (adapted from OSHA Office of Training and Education)
1/05 Means of Egress WAC School Safety Training.
Safety Training Presentation
Means of Egress Chapter 4.
Code Analysis. Identify the relevant codes  Local building code  Local accessibility code (or ADA)  Local fire code (or the NFPA)  Mechanical, electrical.
Decoded 3 – Egress and Life Safety Audio: , Code: Mute your phone (*6 to mute, #6 to unmute) This webinar is being recorded.
MINNESOTA CHAPTER AUTOMATIC FIRE ALARM ASSOCIATION Requirements of the 2003 Minnesota State Fire Code relating to Group R Occupancies September 14, 2006.
Lift Typical Building Floor Plan. Complete with fire walls. Click on and we will add Some of the different Passive and Active systems that you could come.
Code Analysis: Don’t try this at home. Identify the relevant codes  Local building code  Local accessibility code (or ADA)  Local fire code (or the.
ID 440: Project 1: Hospitality Design
Means of Egress and Fire Protection. Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers each year There is a long.
The Essentials of Egress
INTD 51 human environments building code. building codes deal with almost every area of building planning, design & construction they are very complex.
Design Development Code analysis Partition types.
ID 234 Building Codes Fall 2012 Means of Egress Chapter 4.
BUILDING CODES AND ADA/TAS. BUILDING CODES - EGRESS.
Means of Egress Part 3 Chapter 4.
ID 234 Building Codes Fall 2012 Vertical Components of Egress.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
PARKING…..
Codes.
OCCUPATIONAL SAFETY AND HEALTH Do you remember those school fire drills ? Well, here you go again !
1 Ideas Board “Inspiration From Those Who Have Inspired”
ID 234 Building Codes Fall 2011 Means of Egress Chapter 3, part II.
Chapter 4 ID 234 Building Codes Fall 2011 Means of Egress.
Work Area Method Level 3 Alterations – Chapter 9 prescribes requirements. 50% of Building Area Rule.
Means of Egress Don Ebert- Risk Manager (509)
NFPA 101 Life Safety Code Means of Egress Presented By:
Exercise #2 (part 2) Based on what you read in Chapter 4, determine if the corridors and exit doors meet the requirements for egress width, according to.
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
2009 IBC Egress Issues in Commercial Buildings, May 25, 2011
Chapter 2 Building Occupancy
Chapter 3 Part 2: Occupant load
Considerations for Cryostat Membrane Materials Storage Underground
Occupancy Classifications and Loads
Table of Contents for Subpart E Coverage and Definitions
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
RULES OF ENGAGEMENT.
Occupancy Classifications and Loads
OSHA Regulations Part 1910 Subpart E
Presentation transcript:

Determining the Occupant Load Occupant loads are based upon three factors: Occupancy Classification Square footage of the floor or area Occupant Load Factor

Existing Versus New Buildings For existing building compare the calculated occupant load with the actual occupancy in the building, take whichever occupancy is higher! For new buildings, use the calculated occupant load and design for that value

Occupant Load Steps Classify the Building Industrial Occupancy Find the Occupant Load Factor Table 7.3.1.2 in Chapter 7 of NFPA 101 Dividing the floor area assigned to that use by the occupant load factor For determining the floor area, use the gross or net square footage as required in the codes Net square footage: Does not include areas such as restrooms, closets, and mechanical rooms The table indicates when to use net versus gross square footage

Determining Capacities of Exits With the occupant load calculated, you then need to determine the widths, number, and placement of exits to ensure you can accommodate the design occupant load For example, if you determined the occupant load to be 1,000 people, you need to provide enough exits of sufficient widths and placement to serve 1,000 people Determine what is the minimum acceptable door width

Calculating Capacities of Exits The capacity of an exit is determined by using: The exit width The exit surface (level versus stairs) In some occupancies, if there is a sprinkler system present Example: A door has a width of 38” and the occupancy class is industrial Level components have a capacity factor of .2 Therefore, the one exit can serve up to 190 people (38”/.2) If the building has an occupant load of 1,000 people, you will need at least 6 exits (1,000/190 = 5.26)

Travel Distances to Exits Maximum travel distances to exits are determined by occupancy class Different for sprinklered and unsprinklered buildings For a sprinklered industrial facility, the maximum travel distance to an exit is 250 feet

Calculating Travel Distances Measurement of Travel Distance to Exits The travel distance to an exit shall be measured on the floor or other walking surface as follows: (1) Along the centerline of the natural path of travel, starting from the most remote point subject to occupancy (2) Curving around any corners or obstructions with a 12-in. clearance therefrom (3) Terminating at one of the following: Center of the doorway Other point at which the exit begins Smoke barrier in an existing detention and correctional occupancy as provided in Chapter 23

Exit Arrangements Usually, a floor must have a minimum of 2 exits Minimum number increases with occupant load Two exits must meet minimum separation requirements At least 1/3 the diagonal distance of the floor away from each other for sprinklered buildings At least 1/2 the diagonal distance of the floor away from each other for unsprinklered buildings

Exit Termination Exits shall terminate directly, at a public way or at an exterior exit discharge, unless otherwise provided The exit discharge shall be arranged and marked to make clear the direction of egress to a public way.

Illumination Illumination of means of egress shall be continuous during the time that the conditions of occupancy require that the means of egress be available for use. Artificial or natural lighting The minimum illumination levels For example, floors and walking surfaces, other than new stairs, must provide at least 1 ft-candle measured at the floor

Emergency Lighting As required for means of egress in buildings or structures defined by the codes Exit accesses requiring illumination includes only designated stairs, aisles, corridors, ramps, esc Emergency illumination shall be provided for not less than 1½ hours in the event of failure of normal lighting Not less than an initial average of 1 ft-candle and, at any point, not less than 0.1 ft-candle, measured along the path of egress at floor level

Exit Markings, Exit Access Markings, and Directional Signage Exits, other than main exterior exit doors that obviously and clearly are identifiable as exits, shall be marked by an approved sign that is readily visible from any direction of exit access. Access to exits shall be marked by approved, readily visible signs in all cases where the exit or way to reach the exit is not readily apparent to the occupants. Directional signs with a directional indicator showing the direction of travel shall be placed in every location where the direction of travel to reach the nearest exit is not apparent.