SMOULDERING FIRES Sajeesh Nair

Slides:



Advertisements
Similar presentations
CCME, University of Newcastle upon Tyne Composites in Fire September, 2003 WELCOME Introduction to basic ideas of composites in fire WELCOME Introduction.
Advertisements

Flashover Recognition and Survival
Risk Assessment for Cultural Institutions: Fire Testing vs Computer Modeling Frederick W. Mowrer, Ph.D., P.E. Department of Fire Protection Engineering.
Summary of NFPA 101 Interior Finish Requirements
J. Amdahl,, NTNU Dept, Marine Technology Beregning av ulykkeslaster for offshore stålkonstruksjoner – NFS Accidental Fires Design criteria.
Unit 3 Fire Suppression Section 1 Detection and Alarm Systems.
MINISTERO DELL’INTERNO DIPARTIMENTO DEI VIGILI DEL FUOCO, DEL SOCCORSO PUBBLICO E DELLA DIFESA CIVILE DIREZIONE CENTRALE PER LA FORMAZIONE An Application.
Investigation of the Cook County Administration Building Fire Daniel Madrzykowski, P.E., FSFPE William D. Walton, P.E., FSFPE Building and Fire Research.
Enclosure Fire Dynamics
Fire Triangle FuelHeat Fire! Oxygen 1 st Stage: Incipient 1 st stage No visible flame Little smoke Is not yet self-sustaining According to the National.
Enclosure Fire Dynamics Chapter 1: Introduction Chapter 2: Qualitative description of enclosure fires Chapter 3: Energy release rates Chapter 4: Plumes.
Enclosure Fire Dynamics
Eurocode 1: Actions on structures –
Enclosure Fire Dynamics
Enclosure Fire Dynamics
Enclosure Fire Dynamics
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Fire Simulation Software Carlos Gonzalez Garza. Objectives  European Building Regulations.  Combustion  Computational Fluid Dynamics  Discretization.
SAFETY FOLLOW-UP HL-LHC PROJECT WP17 – Infrastructures meeting S. La Mendola, Jose Gascon DGS/SEE 09 July 2015.
Eurocode 1: Actions on structures – Part 1–2: General actions – Actions on structures exposed to fire Part of the One Stop Shop program Annex E (informative)
Kidde Engineered Fire Suppression System 25 bar Equipment Hardware Engineered for use with 3M™ Novec™ 1230 Fire Protection Fluid.
Church Administrators & Emergency Planning
1 Fire risk assessment Samuel Nii Tettey (Ergonomist)
Combustion Processes (con’t from Unit 4)

Atrium Fire Protection
Principles of Fire Behavior
Fire-Related Properties of Materials Chapter 7. Mehta, Scarborough, and Armpriest : Building Construction: Principles, Materials, and Systems © 2008 Pearson.
Chapter 5-Fire Safety Developing Effect Ways to Prevent and Deal With Fires in Your Home.
Wu. Y., International Conference on Hydrogen Safety, September Initial Assessment of the Impact of Jet Flame Hazard From Hydrogen Cars In.
Instrument compartments in Experimental halls 1, 2 & 3 1.
2 DGS-SEE SEMINAR ON FIRE PROTECTION FOR PHYSICS RESEARCH FACILITIES OCTOBER 2015 CERN FIRE SIMULATIONS IN THE PS ACCELERATOR TUNNEL TO DEFINE A.
Case Study Example using SFPE Guidelines for Substantiating a Fire Model for a Given Application Stephen M. Hill, P.E. Craig E. Hofmeister, P.E., LEED.
Fire Resistance of the Load Bearing Structure of High Bay and Instrument Halls Fire and Egress Safety Analysis of the Instrument Halls Björn Yndemark WSP.
Modeling Smoke Transport in Aircraft Cargo Compartments Jill Suo-Anttila ‡, Stefan Domino †, Walt Gill ‡, Paul DesJardin ‡, and Lou Gritzo ‡ ‡ Fire Science.
© Institut de Sécurité 1 Sprinklers for Two New Swiss Detention Buildings Jerzy Respondek Swiss Institute of Safety and Security.
Office of Highway Safety Fire Cause and Propagation.
Fire Detector Placement
KEK, 04/28/061 Safety Plan Assumptions Break out of fire in the Beam Tunnel is negligible Cables in the Service Tunnel is main fire load They are combustible.
Exercise #2 (part 2) Based on what you read in Chapter 4, determine if the corridors and exit doors meet the requirements for egress width, according to.
Aaron Nicholson Beca. by Aaron Nicholson C/VM2 Design vs Non C/VM2 Performance Based Design.
Designing Building Fire Safety EKU. What is Building Fire Safety Limiting Damage to the Building Preventing Damage to Occupants Reducing Fire Spread within.
UNIT 2: FIRE SCENE EXAMINATION Slide 2-1. ENABLING OBJECTIVES Examine a structure from the exterior to interior in a systematic manner to identify indicators.
Fire Training Six monthly training session
Fire Behavior & Extinguisher Use.
Shanghai Research Institute of Building Sciences
FORENSIC ASPECTS OF FIRE INVESTIGATION
FIRE PROTECTION & SECURITY in ELI Beamlines
Fire Extinguisher Training
Fire Resistance Questions
SOME PROBLEMS FOR ASSESSMENT OF FIRE IN ROAD TUNNELS
Structural Fire Engineering, October 2015, Dubrovnik, Croatia
FORENSIC ASPECTS OF FIRE INVESTIGATION
Post-fire Structural Integrity of Composite Gratings for Offshore Platforms Fire Resistance and Fire Reaction of Bio-Composite Sandwiches for Building.
Building Construction
MGM Grand Hotel and Casino Fire
CE 808 : Structural Fire Engineering Ch 3. FIRE AND HEAT
The Station Nightclub Fire Evaluation
Fire and Explosions.
Effect of Earthquake on Fire Protection Systems
FORENSIC ASPECTS OF FIRE INVESTIGATION
PREPARED BY: JOSHIMA V.M., UNIVERSITY OF NIZWA.
Suspended ceiling.
Enclosure Fire Dynamics
Fire Scene Preservation
Fire Characteristics.
Fuel The topic ‘fuel’ is divided into three parts:
Chapter 14 FORENSIC ASPECTS OF FIRE INVESTIGATION
Combustion Reaction Caroline Monger, Emily Smith, Lauren Cochran, Jada Miles, and Erin Ball.
Building construction and Gear
Presentation transcript:

SMOULDERING FIRES Sajeesh Nair Origin Fire Consultants, November 7, 2018

Contents INTRODUCTION DESCRIPTION OF DEFECT SMOULDERING FIRE MECHANISM MODELLING ASSESSMENT RESULTS CONCLUSION Origin Fire Consultants, November 7, 2018

INTRODUCTION Type 7 alarm system (Type 5 in Apartments) Existing Building with Passive Fire Defects Modelling was done to examine the impact on occupants due to smoke spilling into adjacent apartments if defects were not fixed C/VM2 Sprinkler Controlled fire Smouldering Fire (Lots of smoke. Doesn’t activate sprinklers or building evacuation) Origin Fire Consultants, November 7, 2018

PASSIVE FIRE DEFECT IN INTERTENANCY WALL Origin Fire Consultants, November 7, 2018

SMOULDERING FIRE MECHANISM Smouldering is slow, low temperature, flameless form of combustion where heat is released when oxygen directly attacks the surface of solid fuel. Common in porous fuels which form a char on heating (cellulosic insulation, polyurethane foam) Ref: SFPE Handbook of Fire Protection Engineering, 5th Edition, Chapter 19 - Smouldering Combustion Origin Fire Consultants, November 7, 2018

SMOULDERING FIRE CHARACTERISTICS lower temperature and spread rate compared to flaming combustion. Effective heat of combustion is in range from 6 to 12MJ/kg . Heat Release Rate Per Unit Area(HRRPUA) on burning front – 10 to 30kW/m2 Larger Duration (1 hour to 3 hours for single bedroom compartment) Buoyant plume is weak due to low heat release rate and smoke may not reach the ceiling Ref: SFPE Handbook of Fire Protection Engineering, 5th Edition, Chapter 19 - Smouldering Combustion Origin Fire Consultants, November 7, 2018

SOURCES OF INFORMATION (SFPE Handbook 5th Ed) A mattress fire is considered as it can provide fire with a slow growth rate but burn for a long time. The peak HRR is 40kW for cotton padding material(SFPE Handbook 5th Ed, Table 26.15) The peak HRR for mattresses which smouldered were in the range of 26kW to 60kW (SFPE Handbook 5th edition Table 26.17). Origin Fire Consultants, November 7, 2018

SOURCES OF INFORMATION (Lund University) Lund University (Ref: Staffansson.L.(2010). Selecting design fires. Department of Fire Safety Engineering and Systems Safety, Lund University, (refer Section 10.1)). Expected Peak Heat release rate(after 1 hour) Origin Fire Consultants, November 7, 2018

CHOSEN SMOULDERING FIRE CHARACTERISTICS Spread rate of 9mm/min (instead of 6mm/min) After 1 hour – spread up to 540mm Total area affected 1.18mx1.18m=1.39m2 For HRRPUA of 30kW/m2 Peak heat release rate =30kW/m2x1.39m2 = 42kW Origin Fire Consultants, November 7, 2018

SMOULDERING DESIGN FIRE Peak heat release rate 42kW HRRPUA of 30kW/m2 Δ Hc = 12MJ/kg Ysoot = 0.15 kg/kg Yco = 0.5 kg/kg Origin Fire Consultants, November 7, 2018

SMOULDERING FIRE – B-RISK MODEL Intertenancy Wall gaps 5mm high 10mm high 20mm high Origin Fire Consultants, November 7, 2018

SMOULDERING FIRE – FDS MODEL Recessed lights in the GIB ceiling appear to be well sealed but 50% leakage is assumed around the light fittings to be conservative. Origin Fire Consultants, November 7, 2018

RESULTS Smouldering fire (B-Risk Model) Smouldering fire (FDS Model) Vent Size Adjacent Unit Smoke detector activation time Adjacent Unit ASET(s) ASET – Smoke Detection time 5mm vent 24mins 46.6mins 22.6 mins 10mm vent 23.5mins 45.8mins 22.3 mins 20mm vent 21.6mins 45.1mins 23.5 mins Vent Size Adjacent Unit Smoke detector activation time Adjacent Unit ASET(s) ASET – Smoke Detection 20mm vent 21.6mins 43.3mins 21.7 mins Origin Fire Consultants, November 7, 2018

SMOULDERING FIRE – FDS Snapshots 3D Smoke output@4mins 3D Smoke output@15mins 3D Smoke output@30mins 3D Smoke output@46mins Origin Fire Consultants, November 7, 2018

SMOULDERING FIRE - CONCLUSION Smouldering Fire assessment was carried out to increase our understanding of the risk faced by occupants in the adjacent units due to incomplete fire stopping works on intertenancy walls(5 to 20mm) Smouldering fires are small and have slow growth rate due to low heat release rate. Smouldering fire C/VM2 fire Effective Heat of Combustion (ΔHc) 6-12MJ/kg 20MJ/kg CO yield 0.5kg/kg 0.04kg/kg (preflashover) 0.4kg/kg (postflashover) Soot Yield 0.15kg/kg 0.07kg/kg (preflashover) 0.14kg/kg(postflashover) Origin Fire Consultants, November 7, 2018

SMOULDERING FIRE - CONCLUSION The increase in vent size resulted in more smoke spilling into adjacent apartment and earlier activation of smoke detectors. There is approximately 22 minutes available for evacuation of occupants in the adjacent apartments after their smoke detector activates before conditions become untenable which is a considerable amount of time for egress compared to the 5 minutes C/VM2 premovement time. Origin Fire Consultants, November 7, 2018

THANK YOU! See you soon :)