DIGITAL RADIOGRAPHY.

Slides:



Advertisements
Similar presentations
Comparison of Film v. Digital Image Display. Process of data capture All image recording systems rely on differential absorption within the patient to.
Advertisements

Image Reconstruction.
The Field of Digital Radiography
Copyright © 2011 Wolters Kluwer Health | Lippincott Williams & Wilkins CHAPTER 15 Creating the Digital Image.
Primary Exposure Factors IV
Digital Radiography.
RADIOLOGY. NEXT GENERATION SCIENCE / COMMON CORE STANDARDS ADDRESSED! CCSS.ELA-Literacy.RST Determine the central ideas or conclusions of a text;
RAD 354 Chapt. 26 Digital Imaging Many types/names for the digital imaging to come – Types CR: Barium fluorohalide PSP SPR (scan projection RAD): Nal scintillator/photodiode.
Digital Radiographic Imaging 101
Digital Imaging CHAPTERS 1, 4-7 CARTER.
Digital Radiography Chapter 22. History of Digital Radiography Slower process of conversion because no pressing need to convert to digital radiography.
Direct Digital Radiography or Direct Capture Radiography Bushong Ch. 27.
Elsevier items and derived items © 2008 by Mosby, Inc
Conventional and Computed Tomography
Digital Image Characteristic
DIGITAL FLUOROSCOPY.
Computed Radiography and Digital Radiography
Unit III Creating the Image. Unit III Creating the Image.
Chapter 6: Digital Radiographic Imaging
Computers in Imaging Q & A Robert Metzger, Ph.D..
Quality Control.
SPECIAL IMAGING/ADVANCED IMAGING INTRODUCTION TO DIGITAL RADIOGRAPHY
Lecture (2). 2 1.Explain how to produce x-rays and discuss its properties 2.List the basic components of the radiographic machine and identify primary.
DIGITAL PROJECTION RADIOGRAPHY COMPUTED RADIOGRAPHY
Image Quality Radiographic Resolution.
Stacy kopso, M.Ed., rt(r)(m) ODIA digital Academy, arrt
Digital Radiology. 2 Aim : To become familiar with the digital imaging techniques in projection radiography and fluoroscopy.Aim : To become familiar with.
1 Digital Radiography Fall filmless’ radiology departments Diagnostic radiographers have traded their film and chemistry for a computer mouse.
Computed Radiography.
Rad Tech 265 More Digital Imaging. Digital Fluoroscopy Radiation dose –Patient dose for DF is significantly less than conventional fluoro At 7.5 pulses/second.
RAD 254 Digital Imaging Basic Elements of Digital Imaging CR/DR.
Digital Imaging. acronyms 1.PSP 2.CRT 3.ADC 4.IP 5.CR 6.DR 7.PACS 8.SNR 9.CNR 10. CCD 11. FOV 12. LUT 13. DICOM 14. RIS 15. HIS 16. TFT 17. DQE 18. DAP.
Factors affecting CT image RAD
Computed Radiography By Prof. Stelmark. Presently, an acceleration in the conversion from screen-film radiography (analog) to digital radiography (DR)
Image Capture. X-Ray X-Ray Generation Film Can be exposed directly to x-ray, but sensitivity is very low Nitrate – 1910s to 1930s Acetate – 1920s to.
Digital Radiography and PACS By Professor Stelmark.
Things they never tell you when the equipment is installed REV 11/2008
Review CR & DIGITAL IMAGING (1) 2012 – RT 244 wk 15
Computer History Earliest computer was the abacus abacus invented around 3,000 B.C. other calculating machines developed in 1600’s digital computer started.
Digital Imaging.
Image Production and Evaluation NOTE: QA AND QC ARE USED INTERCHANGABLY IN APPLETON AND LANGE.
The production of X-Rays X-Rays are produced whenever charged particles are slowed down or stopped. X-rays are generated via interactions of the accelerated.
Image Display. But first a review Remember the 3 main steps 1. Data Acquisition 2. Image Reconstruction 3. Image Display.
RAD 254 Chapter 27 Digital Fluoroscopy
IMAGE RECEPTORS. Follow the Sequence- Film System Tube Tube Patient Patient (bucky) or non-bucky (bucky) or non-bucky Cassette Cassette INTENSIFYING SCREEN.
DIGITAL IMAGING.
IMAGE ACQUISITION FILM SCREEN SYSTEM. PROCESSING THE LATENT IMAGE AUTOMATIC AUTOMATIC DARKROOM PROCESSOR DARKROOM PROCESSOR DAYLIGHT PROCESSOR DAYLIGHT.
Digital Radiographic Image Processing and Manipulation Chapter 7.
Digital Radiology Dr M A Oghabian Medical Physics Group Tehran University of Medical Sciences
Image Receptor Unsharpness By Professor Stelmark.
By Prof. Stelmark. Digital Imaging In digital imaging, the latent image is stored as digital data and must be processed by the computer for viewing on.
DIGITAL RADIOGRAPHY.
Direct Digital Radiography or Direct Capture Radiography
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 1 Digital Imaging Instead of Radiography.
History of digital radiology 1980 Kinos L.T. ET all developed a portable radiographic X-ray camera made of tantalum and aluminum. Digital radiography.
B ASIC P HYSICS OF D IGITAL R ADIOGRAPHY By : Maisa Alhassoun Recommended Book: Walter Huda, REVIEW OF RADIOLOGIC PHYSICS &
Comparison of Film v. Digital Image Display
Digital Imaging.
Rad Tech 265.
כיצד נרכשת התמונה בסרט הרנטגני?
Computed Radiography Feb.
Fundamentals of Digital Radiology
Digital Imaging CHAPTERS 1, 4-7 CARTER.
Image Production and Evaluation
COMPUTED RADIOGRAPHY.
Digital Radiographic Image Processing and Manipulation
Digital Imaging.
Digital Imaging.
Digital radiography.
Presentation transcript:

DIGITAL RADIOGRAPHY

Digital Fluoroscopy Input phosphoroutput phosphor electronic signal beam splitter video signal  TV monitor Video signal is a voltage signal which varies continuously  ADC (Analog Digital Converter) converts analog to digital

What are some negatives of conventional (film) radiography? Difficult to image both soft tissue and bony structures in same image Difficult to differentiate between the subtle differences of soft tissues (shades of gray---long contrast, low contrast) Unable to gather quantitative info about attenuation characteristics of anatomy Image is processed permanent as is Amount of time needed to process Archiving/storage/ acquisition issues

Similarities between CR and film radiography Same x-ray tube and generator Still select optimum kVp and mAs Accurate positioning Use cassette or image receptor There is still a latent image which can be processed into a manifest image

DIFFERENCES Imaging plate rather than intensifying screen/film Photostimulable phosphor-europium activated barium fluorohalide phosphor 200 screen speed equivalent Phosphors absorb photons Capable of wider latitudes = better visualization of soft tissues and bone

DIFFERENCES CONT. Film made of minute strands of black metallic silver Digital image = rows and columns called a matrix

MATRIX, PIXEL AND VOXEL Matrix made up of pixels ( picture element) Pixels = x-ray intensity at that location and given a numeric value for the shade of gray Voxel represent the volume of tissue of the patient Matrix preferred size – 2048 x2048 or 4, 194,304 pixels Larger matrix = more pixels and pixels are smaller

IMAGE ACQUISITION Exit(remnant radiation) IP photons absorbed photoelectrically by phosphor LATENT IMAGE Exposed IP reader unit (digitizer) scanned to release energy as light  photomultiplier tube (PMT) collects, amplifies and converts light to electronic signal to ADC manifest image

Manifest image is a matrix composed of pixels with assigned brightness levels IP scanned again with intense light to erase plate 10,000 readings

Histograms/window or index levels/algorithms Histogram-graphic display of digital data Used to evaluate adequacy of IP to x-rays PMT needs to be adjusted to compensate for errors Window/index levels – Algorithms – math formulas needed to formulate image construction based on anatomy imaged Radiographer must indicate correct procedure so the correct algorithms are used.

IP or IR

IR/IP List some characteristics of an IP What speed film screen system is associated with a typical IP? How does this affect technique?

DR DIRECT READOUT DIGITAL RADIOGRAPHY FLAT PANEL DIRECT CAPTURE DETECTOR CHARACTERISTICS? COMPARE INDIRECT CONVERSION TO DIRECT

Post processing Subtraction Contrast enhancement Edge enhancement Black and white reversal Compensate for errors

Misc. Resolution =2.5 line pairs per millimeter Window level = adjusts image brightness Window width = adjusts radiographic contrast Quantum mottle Artifacts Scatter

PACS HIS RIS