Planar Edgeless Silicon Detectors for the TOTEM Experiment

Slides:



Advertisements
Similar presentations
Eija Tuominen Siena TEST BEAM RESULTS OF A LARGE AREA STRIP DETECTOR MADE ON HIGH RESISTIVITY CZOCHRALSKI SILICON Helsinki Institute of Physics,
Advertisements

The LHCb Inner Tracker Marc-Olivier Bettler SPS annual meeting Zürich 21 February 2007.
D. Peterson, “ILC Detector Work”, Cornell Group Meeting, 4-October ILC Detector Work This project is supported by the US National Science Foundation.
Striplet option of Super Belle Silicon Vertex Detector Talk at Joint Super B factory workshop, Honolulu 20 April 2005 T.Tsuboyama.
LHCC referees meeting, 10 October 2005Børge Svane Nielsen, NBI1 Status of the FMD LHCC referees meeting, 10 October 2005 Børge Svane Nielsen Niels Bohr.
The AMS-02 detector is based on a large acceptance (~0.5 m²sr) and high sensitivity spectrometer composed by a super-conducting magnet (0.8 T), cooled.
Module Production for The ATLAS Silicon Tracker (SCT) The SCT requirements: Hermetic lightweight tracker. 4 space-points detection up to pseudo rapidity.
The LHCb Inner Tracker LHCb: is a single-arm forward spectrometer dedicated to B-physics acceptance: (250)mrad: The Outer Tracker: covers the large.
Abstract We constructed and tested seven scintillation counters using photomultiplier tubes, in order to create a fast electronic coincidence “trigger”
STS Simulations Anna Kotynia 15 th CBM Collaboration Meeting April , 2010, GSI 1.
Semiconductor detectors
Edgeless Medipix sensors for medical X-ray imaging applications Marten Bosma BND School in Rathen, 2009-Sep-14.
G. Ruggiero/TOTEM 1 The TOTEM Experiment T1 Telescope (CSC) T1 Telescope (CSC) T2 Telescope (GEM) T2 Telescope (GEM) Roman Pots (Si Edgeless detect.) Roman.
Gueorgui ANTCHEVNEC’2013 – Varna, Bulgaria 1 The TOTEM Experiment Consolidation and Upgrade G. Antchev * On behalf of the TOTEM Collaboration * INRNE-BAS,
Semi-conductor Detectors HEP and Accelerators Geoffrey Taylor ARC Centre for Particle Physics at the Terascale (CoEPP) The University of Melbourne.
Monte Carlo Comparison of RPCs and Liquid Scintillator R. Ray 5/14/04  RPCs with 1-dimensional readout (generated by RR) and liquid scintillator with.
1 SiLC sensors for the LP-TPC Thomas Bergauer Institute for High Energy Physics (HEPHY) Austrian Academy of Sciences, Vienna for the SiLC Collaboration.
Medipix sensors included in MP wafers 2 To achieve good spatial resolution through efficient charge collection: Produced by Micron Semiconductor on n-in-p.
1 Tehniline ülevaade uusimast füüsikast CERN’is Endel Lippmaa 20. Detsember 2006, TTÜ.
Construction and Installation Readiness of TOTEM Roman Pots Detectors Federico Ravotti (PH/TOT) Gennaro Ruggiero (PH/TOT) LHCC minireview – 06 May 2009.
HallA/SBS – Front Tracker PARAMETERDESIGN VALUE Microstrip Silicon Detector Number of tiles/plane and size2 Number of planes2 Size of the single
The ALICE Forward Multiplicity Detector Kristján Gulbrandsen Niels Bohr Institute for the ALICE Collaboration.
RP detectors CTS Sensors now in production, full delivery between February and June 07 Production GUI and DB being finalised Test Procedure being defined.
Design and development of micro-strip stacked module prototypes for tracking at S-LHC Motivations Tracking detectors at future hadron colliders will operate.
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger,
8 July 1999A. Peisert, N. Zamiatin1 Silicon Detectors Status Anna Peisert, Cern Nikolai Zamiatin, JINR Plan Design R&D results Specifications Status of.
Planar Edgeless Silicon Detectors for the TOTEM Experiment 1.E-09 1.E-06 1.E /T, 1e3/K Current, A (294K) (256K)(227K)(204K) Gennaro Ruggiero,
CBM Silicon Tracking System. Microstrip Detector Module Assembly and Test V.M. Pugatch Kiev Institute for Nuclear Research GSI (CBM experiment), Darmstadt.
Total Cross Section, Elastic Scattering and Diffraction Dissociation at the LHC January 17, 2003TOTEM plenary meeting -Marco Bozzo1 CSC detectors for T1.
- Performance Studies & Production of the LHCb Silicon Tracker Stefan Koestner (University Zurich) on behalf of the Silicon Tracker Collaboration IT -
The DAMPE STK G. Ambrosi INFN Perugia. The DAMPE Detector Mass: 1480 Kg Power: 600 W Data: 16 Gbyte/day Liftime: 5 years 2.
Abstract Beam Test of a Large-area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger,
3D sensors for tracking detectors: present and future applications C. Gemme (INFN Genova) Vertex 2013, Lake Starnberg, Germany, September 2013 Outline:
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
The LHCb Vertex Locator Lars Eklund LHCb VELO Group of the LHCb Collaboration CERN (Geneva), EPFL (Lausanne), NIKHEF (Amsterdam), University of Glasgow,
Gennaro Ruggiero CERN, PH Depart. Planar Edgeless Detectors for the TOTEM Experiment On the behalf of the TOTEM Collaboration
Convergence in Proton Reconstruction Algorithm and final reference tests of Roman pots before installation in LHC Ayah Massoud Penn State University Supervisor:
Status of the Planar Edgeless Silicon Detectors Gennaro Ruggiero TOTEM Collaboration Meeting 09/11/2005.
G. Ruggiero / TOTEM 1 Si Edgeless Detectors in the RPs Edgeless detector (on the old “AP25 module”) active edges (“planar/3D”) planar tech. with CTS (Current.
A New Inner-Layer Silicon Micro- Strip Detector for D0 Alice Bean for the D0 Collaboration University of Kansas CIPANP Puerto Rico.
Edgeless semiconductor sensors for large-area pixel detectors Marten Bosma Annual meeting Nikhef December 12, 2011, Amsterdam.
The BTeV Pixel Detector and Trigger System Simon Kwan Fermilab P.O. Box 500, Batavia, IL 60510, USA BEACH2002, June 29, 2002 Vancouver, Canada.
V.Aulchenko 1,2, L.Shekhtman 1,2, B.Tolochko 3,2, V.Zhulanov 1,2 Budker Institute of Nuclear Physics, , Novosibirsk, Russia Novosibirsk State University,
Total Cross Section, Elastic Scattering and Diffraction Dissociation at the LHC V. Avati University of Helsinki on behalf of the TOTEM Collaboration
1 Interstrip resistance in silicon position-sensitive detectors E. Verbitskaya, V. Eremin, N. Safonova* Ioffe Physical-Technical Institute of Russian Academy.
0 Characterization studies of the detector modules for the CBM Silicon Tracking System J.Heuser 1, V.Kyva 2, H.Malygina 2,3, I.Panasenko 2 V.Pugatch 2,
The timing upgrade project of the TOTEM Roman Pot detectors
Developing Radiation Hard Silicon for the Vertex Locator
Experimental Method: 2 independent detectors on both sides of IP
First production of Ultra-Fast Silicon Detectors at FBK
IBL Overview Darren Leung ~ 8/15/2013 ~ UW B305.
Sep th Hiroshima Xi’an Test-beam evaluation of newly developed n+-in-p planar pixel sensors aiming for use in high radiation environment.
Simulated vertex precision
Recent Results from TOTEM
LHCf – CSN1 Trieste O. Adriani
(with R. Arcidiacono, A. Solano)
Design and fabrication of Endcap prototype sensors (petalet)
The LHC collider in Geneva
The Silicon Track Trigger (STT) at DØ
Can micro channeling improve the TOTEM experiment
Peter Kodyš, Zdeněk Doležal, Jan Brož,
11th Pisa meeting on advanced detectors
Semiconductor Detectors
Status of CMS-PPS timing detectors
Beam Test Results for the CMS Forward Pixel Detector
Experimental Method: 2 independent detectors on both sides of IP
Variable distance from beam.
The LHCb VErtex LOcator
The LHCb Front-end Electronics System Status and Future Development
Why silicon detectors? Main characteristics of silicon detectors:
Presentation transcript:

Planar Edgeless Silicon Detectors for the TOTEM Experiment To measure the total cross-section of the LHC the TOTEM experiment will detect leading protons coming from the Interaction Point 5 (IP5) The best choice for such detectors are silicon microstrips planes placed orthogonally to the beam axis. Nevertheless in standard fabrication these devices present an insensitive edge of 1mm where termination structures are placed to improve their breakdown performance. To reduce this dead region the TOTEM collaboration has developed a new approach for the realisation of devices with insensitive edges of only 50m!!! Roman Pot Stations The leading proton detectors will be installed in special beam insertion, the Roman Pots and will approach the 10 of the high intensity beam as close as possible. The idea… New Development: Current Terminating Structure The conceptual idea of the new approach is to apply the full detector bias across the detector chip cut and collect the resulting leakage current on an outer ring, which surrounds the active area and which is biased at the same potential as the detecting strips. This ring is separated from the detector biasing electrode. Separating this ring from the bias ring strongly reduces the influence of the current generated at detector edge on the active detector area. In contrast with the other ring structures which provides voltage termination, this structure terminates the current, and therefore we have called it Current Terminating Structure. Terminating structure 40 m wide Thermo-Electric Characterization First silicon detectors with this CTS produced in August 2003 (joined effort between the TOTEM-CERN and Ioffe PTI- St.Petersburg/ RIMST Moscow). 1.E-09 1.E-06 1.E-03 3.4 3.9 4.4 4.9 1/T, 1e3/K Current, A (294K) (256K) (227K) (204K) I1 I2 reverse bias of 100V 40 m I2 I1 + - bias ring Al p+ n+ cut edge SiO2 n-type bulk current terminating ring Detail of the edge of a microstrip silicon detector with Current Terminating Structure. With this type of terminating structure the cut of the dice can be even just 40m away from the end of the strips. Bulk Leakage Current not influenced by the Edge Surface Current (I2 << I1) at 300K I1 does not decrease exponentially with the Temperature Excellent detector stability for biases higher than 200V at room temperature. Cross-section of a Silicon detector with Current Terminating Structure and its biasing scheme. …the proof!!! Test Beam Results (at 300 K) (Sept. ‘03, muon beam in X5 at CERN) RD TD The signal-to-noise performance of the Test Detectors as a function of the x-position as recorded by the Reference Detector have shown a uniform value around 22 until 50m away from the strips end. This suggests full efficiency up to this position. However, the S/N distributions at the edges show a slight decrease in the pulse height, indicating a loss in efficiency of 10-20 %. Self-referencing module with detectors and readout electronics The sensitivity at the edge of detectors with CTS has been measured with a muon beam by checking coincident hits in two Test Detectors with CTS with the cut edges, facing each other and being parallel, and in a Reference Detector placed on their back with the strip direction parallel to the sensitive edges of the two TD’s. Due to the high spatial resolution of the RD (strip pitch of 50 microns), the insensitive distance between the two TD’s can be measured precisely and can be compared with the mechanical distance enabling a precise determination of the efficiency drop at the edges of the test detectors Signal-to-noise distribution of the test detector at the edge as recorded by the reference detector at the end of the strip (position 74) and 50 m away (position 75 ) Metrology: (1209±10)m TD TD Data from Test Beam: (1229±8)m Gennaro Ruggiero, CERN, PH Department, CH-1211 Geneva 23, Switzerland e-mail: gennaro.ruggiero@cern.ch On behalf of the TOTEM Collaboration Self-referencing module made of a board in G10 laminated with kapton hosting a reference detector (RD) and two test detectors (TD). All the detectors readout with APV25 chips packed in the CMS TOB hybrid Distribution of hits in the reference detector in coincidence with hits in the two test detectors. Their fit is compared to the beginning of the sensitive area of the two TD’s (dashed red line).