UVIS Calibration Update

Slides:



Advertisements
Similar presentations
1. absolute brightness - the brightness a star would have if it were 10 parsecs from Earth.
Advertisements

Dr Matt Burleigh The Sun and the Stars. Dr Matt Burleigh The Sun and the Stars Binary stars: Most stars are found in binary or multiple systems. Binary.
Disk-Integrated Polarization of the Moon in the Ultraviolet from SOLSTICE M. Snow, G. Holsclaw, W. McClintock, T. Woods University of Colorado/LASP
Stellar Continua How do we measure stellar continua? How precisely can we measure them? What are the units? What can we learn from the continuum? –Temperature.
Universe Eighth Edition Universe Roger A. Freedman William J. Kaufmann III CHAPTER 17 The Nature of Stars CHAPTER 17 The Nature of Stars.
The Properties of Stars Masses. Using Newton’s Law of Gravity to Determine the Mass of a Celestial Body Newton’s law of gravity, combined with his laws.
Nov. 6, 2008Thanks to Henrietta Leavitt Cepheid Multiplicity and Masses: Fundamental Parameters Nancy Remage Evans.
Ch. 8 – Characterizing Stars part 3: The Hertzsprung-Russell Diagram Luminosity Classes Spectral Types.
Rachel Klima (on behalf of the MASCS team) JHU/APL MASCS/VIRS Data Users’ Workshop LPSC 2014, The Woodlands, TX March 17,2014 MASCS Instrument & VIRS Calibration.
Layers of the Solar Atmosphere Corona Chromosphere Photosphere Details of solar activity can be seen more easily in the hotter outer layers, which are.
The Nature of the Stars Chapter 19. Parallax.
Spring School of Spectroscopic Data Analyses 8-12 April 2013 Astronomical Institute of the University of Wroclaw Wroclaw, Poland.
The mass ratio of the stellar components of a spectroscopic binary can be directly computed from their ratio in radial velocities. To derive the total.
200 MG 500 MG TheoryObservation Authors Institutes RE J is a hydrogen rich strongly magnetic white dwarf discovered as an EUV source by the ROSAT.
Distortion in the WFC Jay Anderson Rice University
Universe Eighth Edition Universe Roger A. Freedman William J. Kaufmann III CHAPTER 17 The Nature of Stars CHAPTER 17 The Nature of Stars.
Chapter 10 Measuring the Stars. Units of Chapter 10 The Solar Neighborhood Luminosity and Apparent Brightness Stellar Temperatures Stellar Sizes The Hertzsprung-Russell.
14 October Observational Astronomy SPECTROSCOPY and spectrometers Kitchin, pp
High Precision Astrometry and Parallax from Spatial Scanning Part 2 Adam Riess and Stefano Casertano.
Lecture Outlines Astronomy Today 8th Edition Chaisson/McMillan © 2014 Pearson Education, Inc. Chapter 17.
SUNYAEV-ZELDOVICH EFFECT. OUTLINE  What is SZE  What Can we learn from SZE  SZE Cluster Surveys  Experimental Issues  SZ Surveys are coming: What.
Dirk Terrell Southwest Research Institute Dirk Terrell Southwest Research Institute Eclipsing Binary.
The Nature of the Stars Chapter 19. Parallax.
Stars Stellar radii –Stefan-Boltzman law Measuring star masses.
Stars: Binary Systems. Binary star systems allow the determination of stellar masses. The orbital velocity of stars in a binary system reflect the stellar.
MOS Data Reduction Michael Balogh University of Durham.
Stars come in all sizes, small, large and even larger.
Copyright © 2010 Pearson Education, Inc. Lecture Outline Chapter 10 Measuring the Stars.
Universe Tenth Edition Chapter 17 The Nature of the Stars Roger Freedman Robert Geller William Kaufmann III.
Rev 131 Enceladus’ Plume Solar Occultation LW Esposito and UVIS Team 14 June 2010.
UVIS calibration update Greg Holsclaw, Bill McClintock Jan 7, 2008.
SORCE - Spectral Irradiance Monitor Stéphane Béland 1, J. Harder 1, M. Snow 1, G. Thuillier 2 1 LASP – University of Colorado Boulder 2 LATMOS-CNRS SOSLPEC.
UVIS calibration update Greg Holsclaw Bill McClintock Jan 8,
Discovering the Universe Eighth Edition Discovering the Universe Eighth Edition Neil F. Comins William J. Kaufmann III CHAPTER 11 Characterizing Stars.
UVIS Calibration Update Greg Holsclaw Jun 16,
Orbits and Masses of Stars Types of Binary Stars Visual Binaries Spectroscopic Binaries/Doppler Effect Eclipsing Binary Stars Main Sequence/Mass-Luminosity.
© 2017 Pearson Education, Inc.
UVIS Calibration Update
UFOAnalyzerV2 (UA2) the key of accuracy
NOAA VIIRS Team GIRO Implementation Updates
Figure 1. Left – a small region of a typical polarized spectrum acquired with the ESPaDOnS instrument during the MiMeS project. This figure illustrates.
© 2017 Pearson Education, Inc.
VIRTIS flyby of Steins M-IR Spectral analysis
Institute of Cosmos Sciences - University of Barcelona
Examinations of the relative alignment of the instruments on SOT
Chapter 10 Measuring the Stars
A Beginner’s Guide to the Universe
Chapter 15 Surveying the Stars
RTWT and Science Planning Report
UVIS Performance Status
Binary Orbits.
Devil physics The baddest class on campus IB Physics
NanoBPM Status and Multibunch Mark Slater, Cambridge University
HDAC status and analysis: Photometric observations by HDAC onboard Cassini Yuri Skorov, Horst Uwe Keller, Ralf Reulke, Karl-Heinz Glassmeier, Vlad.
Photometric observations by HDAC onboard Cassini: sensitivity and first comparison with models Yuri Skorov, Horst Uwe Keller, Ralf Reulke, Karl-Heinz.
T. J. Okamoto (NAOJ/Kyoto Univ.)
UVIS Calibration Update
Chapter 4B: SOLAR IRRADIATION CALCULATION
UVIS Calibration Update
UVIS Calibration Update
UVIS Calibration Update
UVIS Calibration Update
UVIS Saturn EUVFUV Data Analysis
Celestial Distances A Galaxy 150 Million Light Years From Earth
goes-16/17 abi lunar calibration
Remote sensing in meteorology
GEOMETER Update Get new version of GEOMETER from Team web site after August 8. Some new parameters now computed (illum angles for “near point” of non-intersecting.
The Sun and Stars.
UVIS Calibration Update
Presentation transcript:

UVIS Calibration Update Greg Holsclaw, Bill McClintock Jan 6, 2009

Outline Recent calibration observations FUV degradation and Spica variability Stellar flux comparisons with SOLSTICE The flat field for small / unresolved targets Changes in the sensitivity at Lyman alpha

Recent UVIS Calibrations The last two Spica calibrations suffered data dropouts due to DSN issues: FUV2008_265_23_40_33_UVIS_086IC_ALPVIR001_PRIME FUV2008_309_21_10_33_UVIS_091IC_ALPVIR001_PRIME 2008_265 had enough data to continue the previous analysis of tracking sensitivity degradation and stellar variability

Illustration of data dropouts FUV2008_265_23_40_33_UVIS_086IC_ALPVIR001_PRIME FUV2008_309_21_10_33_UVIS_091IC_ALPVIR001_PRIME

Spica variability

Background on Alpha Vir (Spica) Spica is a non-eclipsing double-lined spectroscopic binary system Though not spatially resolvable, each component is detectable through measurements of out-of-phase Doppler shifts in the constituent spectral lines Non-eclipsing due to large apparent orbital inclination of ~70 degrees Both stars are of a similar spectral class: Primary: B1V Secondary: B4V Spica is the brightest rotating ellipsoidal variable star The stars have a distorted ellipsoidal shape due to mutual gravitation effects As the components revolve, the visible area (and thus the observed flux) changes with orbital phase Since this is a geometric effect, it should be roughly wavelength-independent Orbital period is 4.01454 days Amplitude of flux variation in V-filter ~3% The primary of Spica is a Cepheid variable Periodic variation in the pulsating primary star is much shorter than the system’s orbital period and about a factor of 2 less in magnitude Period is 4.17 hours Amplitude of flux variation in V-filter ~1.5% This short-term variation, identified in 1968, became undetectable in the early 1970’s (but may return again due to precession of the primary’s rotation axis relative to the orbital plane, which has a period of 200 years [Balona, 1986]) http://observatory.sfasu.edu

Ellipsoidal variation model Variation in flux is given by [Shobbrook, 1969; Sterken et al, 1986]: dE = A M2/M1 (R/D)3 (1+e cos(TA+Φ))3 (1-3cos2(TA+TA0+Φ) sin2i ) Where: A=0.822 (wavelength dependent “photometric distortion”) M2/M1 = 1/1.59 (ratio of masses) R = 7.6 Rsun = 5.2858e6 km (polar radius of primary) D = 1.92916e7 km (mean separation between stars) e = 0.14 (orbital eccentricity) TA (true anomaly) T0 = 4.01454 days (orbital period) TA0 = 150 degrees (apparent angle to line of apsides in year 2005, has precession period of 128 years) i = 65.9 degrees (orbital inclination) Φ = empirical phase shift, a free parameter to match with data One period of the expected variation in flux from Spica

Normalized signal vs time The left plot shows the total FUV signal vs time (normalized to the mean), with a line fit The right plot shows the same data with this linear trend removed, along with a theoretical model of the Spica ellipsoidal variation that has been fit to the curve (optimizing only the magnitude and phase offset parameters)

Stellar flux comparisons

Stellar flux comparisons We can now compare many of the stellar irradiance measurements from UVIS with those made by SOLSTICE Background on the SOLSTICE instrument: An FUV/MUV spectrometer onboard the SORCE spacecraft Built at LASP Absolutely calibrated at the NIST-SURF facility Routinely measures stellar fluxes in order to track sensitivity degradation Irradiance spectra reduced and calibrated by Marty Snow at LASP

List of stars observed by UVIS and SOLSTICE name type UVIS SOLSTICE alp car canopus F0 x alp cma sirius A1 x x alp cru B1 x x alp gru alnair B6 x alp eri achernar B3 x alp leo regulus B7 x x alp lyr vega A0 x x alp pav peacock B2 x x alp peg Markab B9 x alp psa fomalhaut A4 x x alp vir spica B1 x x bet cen B1 x bet cma B1 x bet cru mimosa B0 x bet ori rigel B8 x del cen B2 x del cyg B9 x del sco B0 x x eps cma adara B2 x eps ori alnilam B0 x eps per B0 x eta uma alcaid B3 x x gam ori bellatrix B2 x kap ori saiph B0 x kap vel B2 x lam sco shaula B2 x pi sco B1 x sig sgr Nunki B2 x tau sco B0 x zet cen B2 x x zet oph O9 x zet ori alnitak O9 x zet pup naos O5 x List of stars observed by UVIS and SOLSTICE Stars must be very hot in order to produce significant flux in the FUV Therefore, most stars observed by UVIS are of B and A spectral class Nine stars were observed by both UVIS and SOLSTICE

UVIS spectra This shows the spectral irradiance curves as measured by UVIS A variety of shapes (driven by spectral class) and magnitudes are seen

Star parameters We can use a catalog of stellar parameters to estimate the spectral irradiance from any star using the Kurucz model name Class Vmag Temp Grav Radius Plx alp vir B1 0.98 22387 3.67 7.94 12.44 alp psa A3 1.17 8318 4.19 1.86 130.08 alp cma A0 -1.44 9550 4.27 1.78 379.21 alp cru B0 0.77 24547 3.57 10.00 10.17 alp leo B7 1.36 10965 3.77 3.89 42.09 alp lyr A0 0.03 9333 3.98 2.69 128.93 alp pav B2 1.94 12023 3.48 6.31 17.80 del sco B0 NaN NaN NaN NaN NaN eta uma B3 1.85 11220 3.78 3.89 32.39 zet cen B2 NaN NaN NaN NaN NaN Temp is the effective temperature in Kelvin Radius is in units of solar radius Plx is the parallax in arcseconds as measured by Hipparcos Metallicity assumed to be zero (solar) Stellar data from: Allende Prieto C., Lambert D.L., Astron. Astrophys. 352, 555 (1999), data accessed through VizieR

Kurucz Stellar Models The Kurucz model stellar irradiance at any wavelength is computed in a coarse grid of three variables: temperature, gravity, and metallicity A convenient routine for accessing these models is available from: IUEDAC IDL Software Libraries http://archive.stsci.edu/iue/iuedac.html The routine KURGET1 allows a user to specify a measured temperature, gravity, metallicity and angular size to arrive at a model spectral irradiance from any star: Wavelength range: 9.1 nm to 106 μm Total wavelength steps: 1221 Resolution: ~1nm in the EUV, FUV, MUV Default units: [ergs/cm2/s/Angstrom] Allows linear interpolation between most model grid points

UVIS, SOLSTICE, KURUCZ Three Kurucz models show good consistency, two do not

Ratio of UVIS to SOLSTICE This plot shows the ratio of UVIS spectra (1.1nm bins) to SOLSTICE over 130-180 nm Here, UVIS spectra were reduced using the flat-field While the magnitude varies, a consistent shape in the ratio is apparent WITH flat-field Q - Is the discrepancy dependent on spectral type, signal level, or position on the detector?

Ratio of UVIS to SOLSTICE Normalized to a mean value of one

Ratio of UVIS to SOLSTICE This plot shows the average ratio of UVIS to SOLSTICE for all stars observed (except Alp PsA) Average of all stars

Ratio of UVIS to SOLSTICE This plot shows the average ratio of UVIS to SOLSTICE for all stars observed (except Alp PsA) Expanded vertical scale

Wavelength shift Due to the small uncertainty in spacecraft pointing, a star image could be centered anywhere within six spectral pixels using the low-resolution slit This is effectively an uncertainty in the wavelength scale of the spectrum With an FUV dispersion of 0.078 nm per pixel, this translates to a potential variation of ~0.5 nm Star image UVIS detector pixels are 100 x 25 microns (H x W) Low-res slit is 6 pixels wide UVIS-FUV Low-resolution entrance slit

Wavelength shift adjustment The phase shift between the measured UVIS spectrum and SOLSTICE can be estimated by finding the peak of the cross-correlation function This is done by the following procedure: Shift the UVIS spectrum in one-pixel increments Smooth the UVIS spectrum to 1 nm Interpolate the UVIS spectrum to the SOLSTICE wavelength scale compute the linear correlation coefficient Find the shift value where the maximum correlation occurs This is a small effect for 1 nm resolution spectra

Cross-correlation analysis This shows the correlation coefficient versus UVIS pixel shift A peak in the correlation coefficient is considered a wavelength match All matches occur within four pixels

Average UVIS/SOLSTICE ratio No wavelength shift With individual wavelength shifts

Ratio of UVIS to SOLSTICE vs SOLSTICE irradiance UVIS appears to measure fluxes that are higher at lower signal levels This could be the result of a need to remove an offset, which would preferentially affect measurements of lower signal There is currently no attempt to adjust for nonlinearity due to the detector dead-time; an adjustment would have the effect of increasing the UVIS signal of brighter stars

Ratio of UVIS to SOLSTICE vs surface temperature The dimmer stars also happen to be the cooler ones Effective temperatures from: Allende Prieto C., Lambert D.L., Astron. Astrophys. 352, 555 (1999), data accessed through VizieR

Stars are imaged in the star-burned rows This plot shows the spatial distribution of light on the detector from each star, along with the inverse of the average row-to-row correction from the post-burn flat-field The stars were imaged in the center of the starburned region of the detector It is here that the sensitivity correction is largest, and the spectral shape of the correction the most significant Flat-field corrector Spatial distribution of stars

Spatial distribution of stellar flux measurements No Flat-field applied WITH Flat-field applied These plots show the distribution of light on the FUV detector for each observation of stellar irradiance The curves are normalized to the total signal The images are centered at about row 32

Star comparisons – TO DO Compare spectra from measurements where the star image is located outside of the starburned rows (Alp Vir, Alp Leo, Alp PsA, others?) Look into getting extended SOLSTICE spectra (>180nm) from Marty Check other catalogs to see if the effective temperatures are consistent How are the stellar parameters of temperature, gravity, and metallicity derived? How accurately are they known? Include flux from secondary companion stars Compare the flux from UVIS using Don’s FUV sensitivity curve

Flat-fielding for small targets

Use of the flat-field corrector for small sources The flat-field is meant to correct the high-frequency pixel-to-pixel sensitivity nonuniformity It is derived from the along-slit slew scans of Spica, which approximates a uniform extended source However, it has been noticed that there could be an issue with using the corrector for small (unresolved) targets

Effect of the flat-field on an extended source This demonstrates the effect of applying a flat-field to a uniform extended source Sum of all scans, flat field applied, and sum in the spectral dimension Overcorrection in the starburned rows This approximates the spatial distribution of a uniform extended source Sum of all scans, sum in the spectral dimension

Effect of the flat-field on a point source Total signal vs star position Evil pixels interpolated across No flat-field applied Total signal vs star position Flat-field applied to each frame

Sensitivity at Lyman-alpha

IPH data reduction Identify all UVIS observations which are: FUV Low-resolution Unbinned Unwindowed IPHSURVEY Average all records in each observation Mark all evil pixels as NaNs Average all remaining ‘good’ pixels in each column (row 3 to 60) to form a single spectrum

Filtering IPH data All selected LISM spectra in the DAPS database All LISM spectra which meet a filtering criteria to exclude contamination by stars and data dropouts

Filtering IPH data Select all observations prior to the year 2000 Select all observations after the year 2000 with an average (between pixel 300 and 1023) signal in the range 0.0005±0.00001

Normalizing to a fixed LISM signal All filtered spectra, with the offset subtracted (mean of signal between pixels 990 – 1010) Need to remove LISM signal variation due to distance from the Sun and pointing. Normalize each spectrum to the signal between pixel ranges 100-110 and 150-160

Signal normalized spectra Spectra are normalized to the signal in the shaded regions

Ratio to an early spectrum This shows the ratio of all spectra to an early spectrum This should show the fractional change in sensitivity

Ratio to an early spectrum Look at the change as a function of time for a few pixels

Pixel value vs time This shows the count rate vs time for three spectral columns Each curve is normalized to the mean of the values before 2000 The variation is much larger than the random uncertainty in the detected counts Ideas: Due to a small mislocation in the position of the slit? This is a known effect. Incomplete removal of stellar spectra? Colors here denote different pixels

Poor background subtraction? After subtraction of an estimate of the background (mean of pixels 990-1010) Raw spectra (counts/second) Seems unlikely that some pixels decline more than others. More likely that the background subtraction was poor.

Summary There is a small, approximately linear decline in FUV sensitivity The ellipsoidal variation of Spica continues Comparisons of UVIS measurements of absolute stellar fluxes with SOLSTICE show that there is a variation in absolute magnitude on the order of 30%, and a systematic shape difference The flat-field should be used with caution for small targets There is a measurable decrease in sensitivity at Lyman alpha as a function of time, but the shape is difficult to determine