Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Slides:



Advertisements
Similar presentations
3. Slip and Rotor frequency of IM
Advertisements

Stator Voltage Control
The stator winding are supplied with balanced three-phase AC voltage, which produce induced voltage in the rotor windings. It is possible to arrange the.
ENERGY CONVERSION ONE (Course 25741)
AC DRIVES There are two type of AC motor Drives :
Wind Turbine Session 4.
Induction Motor •Why induction motor (IM)?
Electric Motors and Generators
Power System Fundamentals
SYNCHRONOUS MACHINES SUBMITTED BY: Ms. APOORVA KANTHWAL
EE20A - Electromechanical Energy Conversion Induction Machine
CHAPTER V Motor Drives Motor drive systems definitions
Induction motor1 AC Machine Stator ‘a’ phase axis ‘b’ phase axis ‘c’ phase axis
Prepared by: Luis Fernando Montoya Chun-Ju Huang Ashish K. Solanki
AC MOTOR INDUCTION MOTOR.
Introduction to Electrical Machines
Motor ELECTRICAL ENERGY Mechanical Energy.
PRESENTATION ON INDUCTION MOTOR
Induction Motor Why induction motor (IM)? –Robust; No brushes. No contacts on rotor shaft –High Power/Weight ratio compared to Dc motor –Lower Cost/Power.
DC Machines.
Induction Motors Prepared By : PRAGNESH, MEET, SAGAR, SAAVAN, KANISH
Induction Motors.
Chapter 5. Electric Machines.
Power System Fundamentals EE 317 Lecture 7 20 October 2010.
Performance Characteristics
Induction Machine The machines are called induction machines because of the rotor voltage which produces the rotor current and the rotor magnetic field.
1 Institute of Mechatronics and Information Systems Control and Driving Systems.
Electric Machine Introduction
EET 221 Synchronous Machines Rafiqi.
Magnetic field due to an electric current
BASIC ELECTRICAL TECHNOLOGY DET 211/3
EE SOLID STATE DRIVES UNIT-V SYNCHRONOUS MOTOR DRIVES Mr.R.Essaki Raj, Senior Lecturer EE SOLID STATE DRIVES UNIT-V SYNCHRONOUS MOTOR DRIVES.
Prepared by:- Chandan pathak ( ) Utpal rathod( ) Hitendra vyas( )
Induction Motor (Asynchronous Motor)
Electrical Motor1 3 Phase Induction Motor Mrs R.U.Patil Sr.Lecturer,EPS Dept. V.P.M’s Polytechnic,Thane.
Lesson 12a: Three Phase Induction Motors
CHAPTER 10 SYNCHRONOUS MOTOR Electrical Machines.
THREE-PHASE INDUCTION MOTOR
Prepared by: Luis Fernando Montoya Chun-Ju Huang Ashish K. Solanki
Chapter 5: Speed-Torque Characteristics of Electric Motors
Unit – IV Starting and Speed control of Three phase Induction motor
Electric Motors and Generators
INDUCTION MOTOR Scalar Control (squirrel cage)
Speed control of three phase induction motor
Electric Machine Induction Motor
EMT462 Electrical System Technology
Induction Generators Same basic construction as squirrel-cage induction motors Drive at a speed greater than the synchronous speed Not started as a motor.
Electric Machine Introduction
AC and DC motors.
Wind turbine technology
Presentation of ELECTRIC MACHINES Title: Single Phase Motors By: Rahul Khanna{ }EC3 rd Sem Guided By: Prof. Ravi Patel.
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
Advanced Power Systems
Induction Motor (Asynchronous Motor)
Electric braking Powerpoint presentation by:- Poonam sharma
Energy Conversion and Transport George G. Karady & Keith Holbert
Why is starter necessary for a three-phase induction motor?
Three Phase Induction Motors
EET 323 – Electrical System Design Lecture 13: Motor Circuits
Induction Motor Drives
AC Vector Controlled Drives Induction Motor Drives
Prepared by: Luis Fernando Montoya Chun-Ju Huang Ashish K. Solanki
AC Drives Dr. Adel A. El-Samahy Department of Electrical Engineering University of Helwan.
EEM476 Power Electronics II
Electrical Machines (EELE 3351)
Braking of Three Phase IM
Induction Motors (Lecture 1&2)
Electric Machine Design Course
Electric Machine Design Course
Electric Machine Design Course
Presentation transcript:

Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB Induction Motor Drive Why induction motor (IM)? Robust; No brushes. No contacts on rotor shaft High Power/Weight, Lower Cost/Power ratios Easy to manufacture Almost maintenance-free, except for bearing and other “external” mechanical parts Disadvantages Essentially a “fixed-speed” machine Speed is determined by the supply frequency To vary its speed need a variable frequency supply Motivation for variable-speed AC drives Inverter configuration improved Fast switching, high power switches Sophisticated control strategy Microprocessor/DSP implementation Applications Conveyer line (belt) drives, Roller table, Paper mills, Traction, Electric vehicles, Elevators, pulleys, Air-conditioning and any industrial process that requires variable-speed operation. The state-of-the-art in IM drives is such that most of the DC drives will be replaced with IM in very near future. Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB Torque production (1) Only “squirrel-cage” IM (SCIM) is considered in this module Neglecting all harmonics, the stator establishes a spatially distributed magnetic flux density in the air-gap that rotate at a synchronous speed, w1 : where we : supply frequency (in Hz) p: pole pairs (p=1for 2 pole motor, p=2 for 4 pole motor etc) If the rotor is initially stationary, its conductor is subjected to a sweeping magnetic field, inducing rotor current at synchronous speed. If the rotor is rotating at synchronous speed (i.e. equals to f1), then the rotor experience no induction. No current is induced in the rotor. Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB Torque production (2) At any other rotor speed, say wm, the speed differential wi-w2 creates slip. Per-unit slip is defined as: Slip frequency is defined as: w2=w1-wm. When rotor is rotating at wm., rotor current at slip frequency will be induced. The interaction between rotor current and air-gap flux produces torque. Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Single-phase Equivalent Circuit (SPEC) Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

SPEC, referred to stator From previous diagram, SPEC is a dual frequency circuit. On the stator is w1 and on the rotor wm Difficult to do calculations. We can make the circuit a single frequency type, by referring the quantities to the stator Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB Rotor current Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Performance calculation using SPEC Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Performance calculation (2) Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB Example calculation A single phase equivalent circuit of a 6-pole SCIM that operates from a 220V line voltage at 60Hz is given below. Calculate the stator current, output power, torque and efficiency at a slip of 2.5%. The fixed winding and friction losses is 350W. Neglect the core loss. Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Calculation (solution) Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB Starting current For the previous example, Calculate the stating current when motor is first switched on to rated applied voltage. Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB Approximate SPEC Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Single (fixed supply) frequency characteristics Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Single frequency characteristics Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Single frequency characteristic As slip is increased from zero (synchronous), the torque rapidly reaches the maximum. Then it decreases to standstill when the slip is unity. At synchronous speed, torque is almost zero. At standstill, torque is not too high, but the current is very high. Thus the VA requirement of the IM is several times than the full load. Not economic to operate at this condition. Only at “low slip”, the motor current is low and efficiency and power factor are high. Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Typical IM Drive System BLOCK DIAGRAM Supply Rectifier and Filter 3-phase Inverter n IM CIRCUIT Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Variable speed characteristics For variable speed operation, the supply is an inverter. The frequency of the fundamental AC voltage will determine the speed of IM. To vary the speed of IM, the inverter fundamental frequency need to be changed. The inverter output frequency must be kept close to the required motor speed. This is necessary as the IM operates under low slip conditions. To maintain constant torque, the slip frequency has to be maintained over the range of supply frequencies. Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Variable voltage, variable frequency (VVVF) operation In order for maximum torque production, motor flux should be maintained at its rated value. Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Constant Torque region Hence for VVVF operation, there is a need to control the fundamental voltage of the inverter if its frequency (and therefore the frequency of the IM) need to be varied. To vary the fundamental component of the inverter, the MODULATION INDEX can be changed. The rated supply frequency is normally used as the base speed At frequencies below the base speed, the supply magnitude need to be reduced so as to maintain a constant Volt/Hertz. The motor is operated at rated slip at all supply frequencies. Hence a “constant torque” region is obtained. Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Constant Torque Region Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB Constant Power region Above base speed, the stator voltage reaches the rated value and the motor enters a constant power region. In this region, the air-gap flux decreases. This is due to increase in frequency frequency while maintaining fixed voltage. However, the stator current is maintained constant by increasing the slip. This is equivalent to field weakening mode of a separately excited DC motor. Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB Constant Power region Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB VVVF Summary Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB

Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB Examples A three-phase 4-pole, 10 horsepower, 460V rms/60Hz (line-to line) runs at full-load speed of 1746 rpm. The motor is fed from an inverter. The flux is made to be constsnt. Plot the torque-speed graphs for the following frequency: 60Hz, 45 Hz, 30Hz, 15Hz. A three-phase induction motor is using a three-phase VSI for VVVF operation. The IM has the following rated parameters: voltage: 415V (RMS) frequency: 50Hz slip (p.u) 5% pole pair 2 If the inverter gives 415V (RMS) with modulation index of 0.8, calculate the required modulation index if the motor need to be operated at rotor mechanical speed of 10Hz. Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB