VSS Refractive Procedure Off-line Programming Module.

Slides:



Advertisements
Similar presentations
The author has a financial interest in the matter under presentation Dr. Rupal Shah, New Vision Laser Centers, India.
Advertisements

Faik Orucov*, MD, Sinan Goker*,MD, Abraham Solomon**, MD, Joseph Frucht- Pery**, MD Comparison of Tecnolas and Allegretto laser in situ keratomileusis.
MYOPIA, ASTIGMATISM, HYPEROPIA… PERSONALIZED TREATMENT Bernard Mathys, MD Secretary-general of the Belgian Society of Cataract & Refractive Surgery.
What Every Patient Should Know About Advanced CustomVue™
Confidential | © 2006 Planar Systems, Inc. Set it & Forget it (SiFi) November 06.
Toric and Modern IOL Technology
Refractive Surgery Challenges and their most modern approach D. Alexopoulos MD,DO
Freedom to See Freedom to Be Freedom to Do… Anything You Want.
1 Comparison of bitoric with monotoric laser in situ keratomileusis for the correction of myopic astigmatism with the Nidek EC-5000 Laser. By Mohamed Abdul-Rahman.
Quality Control in Refractive Surgery
INTRODUCTION TO iLASIK TM. It’s Time For The iLASIK ™ Procedure Using a unique combination of the most advanced technology, the iLASIK procedure is fast,
29/01/05www.drmathys.be BSCRS 2005 P R K in 2005 Bernard Mathys, MD Brussels.
Steve Schallhorn MD Myth Busters in Patient Selection for LASIK Steve Schallhorn MD.
Bandage Soft Contact Lenses Role in Pain Control After LASEK: Does Lens Type Make a Difference? Darrel K. Carlton, MD Lieutenant Colonel, Medical Corps.
Swept Source Optical Coherence Tomography for Evaluation of Posterior Corneal Changes after Refractive Surgery Dr. Tommy Chung Yan Chan Dr. Vishal Jhanji.
By Kelsey Matthews. History  LASIK stands for laser in situ keratomileusis  Developed in 1991 by a greek doctor Ioannis Pallikaris  Purpose to correct.
Laser Vision Correction for Myopia, Myopic Astigmatism, Hyperopia and Hyperopic Astigmatism with CustomVis Solid State Laser (213nm) THE ROYAL AUSTRALIAN.
Alex P. Lange The author has no financial interest to disclose.
Wavefront Sensing of the Human Eye
Physician Certification for CustomVue ™ Presbyopic Ablations.
Bausch & Lomb 217A Excimer Laser Overview Why It Is Unmatched!
Paragon CRT Dual Axis Introducing the next step in improving your success with corneal reshaping…. 1. Kính Paragon CRT Dual Axis – Lưỡng Trục Giới thiệu.
STAR S4 IR Excimer Laser System Physician Certification Course Place for Conference or Author Month Day, 200X ST4862.
Professor Ioannis Pallikaris MD, PhD.  Different mediums (Nd:YAG Crystals vs ArF Gas)  Less optics for the shaping of the pulse  No use of toxic gasses.
Evaluation of Safety and Effectiveness of Multizone Laser Vision Correction in Presbyopic Patients ASCRS 2010 Paul Van Saarloos PhD – CustomVis, employee.
Comparison of Wavefront and Corneal Aberration Changes after Advanced Corneal Surface Ablation and Femtosecond Thin Flap LASIK Tahra AlMahmoud, MBBS 1,
Evaluation of Zonal Equivalent Keratometry Readings After LASIK Timmy Kovoor, MD Orkun Muftuoglu, MD V.Vinod Mootha, MD Steven Verity, MD R. Wayne Bowman,
ASCRS 08 Changes Of Higher Order Aberrations After Excimer Laser Treatment For Moderate Myopia by Means of Preoperative Wavefront Aberration Levels using.
March 2011 Bascom Palmer Eye Institute University of Miami Elaine Wu, M.D. Ana Paula Canto, M.D. William Culbertson, M.D. Sonia Yoo, M.D. Financial disclosure:
LADARVision4000 Vs VISX CustomVue LADARVision4000 Vs VISX CustomVue CustomCornea CustomCornea A Comparison of Wavefront Guided Refractive Surgery outcomes.
M. Vokrojova MD, M. Vokrojova MD, D. Sivekova MD, L. Wagnerova MD D. Sivekova MD, L. Wagnerova MD Prof. P. Kuchynka MD, PhD Prof. P. Kuchynka MD, PhD The.
Refractive Accuracy of LASIK Using the IntraLase and Zyoptix BACKGROUND Wavefront guided customized lasik procedures are designed to correct both lower.
Myoung Joon Kim, MD / Sara Yoon, MD Tracy Purcell, PhD / David J Schanzlin, MD L aser In Situ Keratomileusis versus Photorefractive Keratectomy for the.
Michael J. Endl, M.D. The author of this poster has no financial interest in the subject matter of this poster. Early Results of Static and Dynamic Iris.
Laser subepithelial keratomileusis (LASEK) retreatment surgery Colm McAlinden, 1,2 Jonathan Moore, 2,3 1 School of Biomedical Sciences, University of Ulster,
Faik Orucov*, MD, Sinan Goker*,MD, Abraham Solomon**, MD, Joseph Frucht-Pery**, MD *Refractive Surgery Department, ISTANBUL SURGERY HOSPITAL Istanbul,
Comparison of Patient Profiles: Wavefront-Guided LASIK Versus Conventional LASIK Michiho Suzuki-Judge, MD Inouye Eye Hospital Tokyo, Japan Michiho Suzuki-Judge,
Ocular functional optical zone following hyperopic LASIK/PRK: Analysis based on polychromatic retinal image quality Mitchell P. Weikert, MD Li Wang, MD,
Jay Fiore MD, Eric Donnenfeld MD, Hank Perry MD, Dana Morschauser OD
Refractive Outcomes with Advanced Wavefront-Guided LASIK William Trattler, MD Charles Reilly, MD Consultant to the USAF SG for Refractive Surgery Lackland.
Omni-Focal Treatment for Correction of Presbyopia in Hyperopes: 1 Year Results Efekan Coskunseven, Baha Toygar, Serife Atun, Haluk Talu, Ebru Arslan Dunya.
Presbyopia CT Zyoptix Hyperopia Advanced (Rochester) Nomogram Scott MacRae MD Professor of Ophthalmology Professor of Visual Science University of Rochester.
CATz for Highly Irregular Corneas after Keratorefractive Surgery Hamed M. Anwar, MD, FRCS Alaa El-Danasoury, MD, FRCS 1 Institutional affiliation: Magrabi.
Initial clinical experience with the FS200 Femto and EX500 excimer lasers for LASIK ASCRS, San Diego 2011 A.John Kanellopoulos, MD Professor NYU Medical.
Laser in Situ Keratomileusis Decentration With and Without Active Eye-Tracking System Mark Edmund Johnston MD FRCSC P 167: The author.
Laser assisted Corneal normalization in Ectatic disorders
Department of Ophthalmology, University of Ulsan College of Medicine,
Eun Chul Kim, M.D. , Man Soo Kim,M.D.
Wavefront Optimized Retreatment after Prior Wavefront
L. Espandar, MD ; M. D. Mifflin, MD; M. Moshirfar MD, FACS
New corneal topography based procedure for kappa angle compensation in advanced surface ablation(A.S.A.)treatment. Matsliah Taieb,M.D.,Igal Brikman,M.D.Ph.D.
Topographically-guided photo-refractive keratectomy (TG-PRK) for complications of refractive surgery David TC Lin, MD, FRCSC Simon Holland, MD, FRCSC,
Safe Lasik on Thin Cornea with Moderate Myopia
Asociación Para Evitar La Ceguera En México
Comparison of topography-guided (TGL) to standard LASIK (SL) for hyperopia. How important is adjustment for angle kappa? ASCRS 08 A. John Kanellopoulos,
Pharmacological Correction of Presbyopia: A preliminary Study
Introduction and Overview
X y y = x2 - 3x Solutions of y = x2 - 3x y x –1 5 –2 –3 6 y = x2-3x.
Dr Haralabos Eleftheriadis, M.D Ultralase Clinic Bristol UK
C. Lackerbauer MD, A. Wolf MD, A. Kollias, MD, A. Kampik, MD,
PERRY S. BINDER, MS MD* San Diego, California
Standard PRK vs. CustomVue: A Comparison of Haze
Age-related difference in Lasik Treatment
Typical Allegretto Ablation Profiles
Marotte D, Denoyer A, Pisella PJ.
BOGOTA LASER REFRACTIVE INSTITUTE
Effectiveness of Accuracy of Eye Trackers in Laser Refractive Surgery
Stephen G Slade, MD The Laser Center of Houston Houston, Texas
Presentation transcript:

VSS Refractive Procedure Off-line Programming Module

2Company Confidential © 2010 Abbott Medical Optics Inc. *As compared to AMO Conventional treatment. VSS Refractive Procedure A Better Manifest Refraction-based Solution * The VSS Refractive procedure is a manifest refraction-based LASIK treatment for the STAR S4 IR Excimer Laser System providing a better treatment option for patients who are not eligible for a CustomVue procedure. Better Match to Target Ablation Shape Adjustable Treatment Zones Thermally Optimized IL2715 OUS Version

3Company Confidential © 2010 Abbott Medical Optics Inc. Better Match to Target Ablation Shape Variable Spot Size Scanning (VSS) technology ensures accurate match between the target and ablation shapes Enhanced cosine effect compensation Cosine Effect Compensation IL2715 OUS Version

4Company Confidential © 2010 Abbott Medical Optics Inc. VSS Refractive Treatment Zones Recommended Treatment Dimensions: 1.Myopia: Minimum Optical Zone 6.0 mm Ablation Zone 8.0 mm 2. Hyperopia/Mixed Astigmatism: Minimum Optical Zone 6.0 mm Ablation Zone 9.0 mm Optical and Ablation zones are the same as Advanced CustomVue IL2715 OUS Version Important: All indications may not be available. Treatment indications are subject to availability and are defined in treatment keycards.

VSS Refractive Treatment Zones VSS Refractive Treatment Zones are based on the Minimum Optical Zone. The Maximum Optical Zone is calculated based on the relationship between sphere and cylinder. The larger the amount of cylinder, the larger the Maximum Optical Zone. 5Company Confidential © 2010 Abbott Medical Optics Inc IL2715 OUS Version

6Company Confidential © 2010 Abbott Medical Optics Inc. Adjustable Treatment Zones The VSS Refractive software allows the Minimum Optical Zone and the Ablation Zone to be adjusted: Range of Minimum Optical Zone 3.5 to 8.5 mm Range of Ablation Zone 4.5 to 9.5 mm The Transition Zone (Ablation Zone - Minimum Optical Zone) must be between 1 mm to 4.5 mm. Optical and Ablation zones are the same as Advanced CustomVue IL2715 OUS Version

7Company Confidential © 2010 Abbott Medical Optics Inc. Thermally Optimized The Combination of VSS and VRR technology: –Provides for both thermal balancing and optimal ablation time Variable Repetition Rate (VRR) technology minimizes thermal impact on the cornea. Variable Spot Size Scanning (VSS) technology ensures an accurate match between the target and ablation shapes IL2715 OUS Version

8Company Confidential © 2010 Abbott Medical Optics Inc. VSS (10 Hz) Max = °C VSS + VRR Max = °C Thermally Optimized The addition of VRR technology reduces the peak temperature. Degree Change (°C) Technology simulations. Not actual procedures IL2715 OUS Version

9Company Confidential © 2010 Abbott Medical Optics Inc. VSS Refractive Procedure – A Better Manifest Refractive-based Treatment Option Product Attribute:Advanced CustomVue VSS Refractive Conventional Variable Spot Scanning Variable Repetition RateNo Improved AlgorithmsNo Adjustable Treatment ZonesNo Enhanced Cosine CompensationNo HOA CorrectionNo Iris RegistrationNo Wavefront Guided TreatmentNo IL2715 OUS Version