Numerical simulations on single mask conical GEMs

Slides:



Advertisements
Similar presentations
GEM Chambers at BNL The detector from CERN, can be configured with up to 4 GEMs The detector for pad readout and drift studies, 2 GEM maximum.
Advertisements

Standard GEM Charging Up Simulation: First test of the approach Matteo Alfonsi, Gabriele Croci, Serge Duarte Pinto, Leszek Ropelewski, Rob Veenhof, Marco.
Field Cage Simulation Study for Prototype Cherenkov TPC Michael Phipps, Bob Azmoun, and Craig Woody.
Micro MEsh GASeous Detectors (MicroMegas)
GEM Detector Shoji Uno KEK. 2 Wire Chamber Detector for charged tracks Popular detector in the particle physics, like a Belle-CDC Simple structure using.
E-field calculations for the TPC/HBD N. Smirnov Upgrade Working Group Meeting 05/13/03, BNL.
New Readout Methods for LAr detectors P. Otyugova ETH Zurich, Telichenphysik CHIPP Workshop on Neutrino physics.
Status of simulation studies of IBF for GEMs
Atsuhiko Ochi Kobe University / MAMMA collaboration 24/04/2013 RD51 mini week, WG6.
Carleton University A. Bellerive, K. Boudjemline, R. Carnegie, A. Kochermin, J. Miyamoto, E. Neuheimer, E. Rollin & K. Sachs University of Montreal J.-P.
Atsuhiko Ochi Kobe University 25/06/2013 New Small Wheel MicroMegas Mechanics and layout Workshop.
Simulation of the spark rate in a Micromegas detector with Geant4 Sébastien Procureur CEA-Saclay.
IHEP, Bejing 9th ACFA ILC Physics and Detector Workshop & ILC GDE Meeting The preliminary results of MPGD-based TPC performance at KEK beam.
1 The GEM Readout Alternative for XENON Uwe Oberlack Rice University PMT Readout conversion to UV light and proportional multiplication conversion to charge.
GEM: A new concept for electron amplification in gas detectors Contents 1.Introduction 2.Two-step amplification: MWPC combined with GEM 3.Measurement of.
Sheffield : R. Hollingworth, D. Tovey R.A.L. : R.Luscher Development of Micromegas charge readout for two phase Xenon based Dark Matter detectors Contents:
EPS-HEP 2015, Vienna. 1 Test of MPGD modules with a large prototype Time Projection Chamber Deb Sankar Bhattacharya On behalf of.
Development of a TPC for the Future Linear Collider on behalf of the LC TPC groups Aachen, Berkeley, Carleton, Cracow, DESY, Hamburg, Karlsruhe, MIT, Montreal,
Experimental and Numerical studies on Bulk Micromegas SINP group in RD51 Applied Nuclear Physics Division Saha Institute of Nuclear Physics Kolkata, West.
1 IBF in aligned, misaligned and FLOWER THGEMs The IBF problem Standard THGEM configuration COBRA and extra electrode Misaligned holes FLOWER THGEM solution.
GEM basic test and R&D plan Takuya Yamamoto ( Saga Univ. )
1/18 01/26/2007MPGD Workshop in Saga (Yorito Yamaguchi, CNS, Univ. of Tokyo) 東大 CNS における GEM の基本動 作特性の研究 Measurement of basic properties of GEM at CNS,
IHEP, Beijing 9th ACFA ILC Physics and Detector Workshop & ILC GDE Meeting The preliminary results of MPGD-based TPC performance at KEK beam.
Summer Student Session, 11/08/2015 Sofia Ferreira Teixeira Summer Student at ATLAS-PH-ADE-MU COMSOL simulation of the Micromegas Detector.
Wenxin Wang 105/04/2013. L: 4.7m  : 3.6m Design for an ILD TPC in progress: Each endplate: 80 modules with 8000 pads Spatial Resolution (in a B=3.5T.
Standard GEM Charging Up Simulation Gabriele Croci, Matteo Alfonsi, Serge Duarte Pinto, Leszek Ropelewski, Rob Veenhof, Marco Villa (CERN), Elena Rocco.
Goddard February 2003 R.Bellazzini - INFN Pisa A new X-Ray Polarimeter based on the photoelectric effect for Black Holes and Neutron Stars Astrophysics.
December 10, The Parallel Plate Chamber CERN Presentation Wout Kremers Detector R&D NIKHEF.
Numerical Studies on IBF of BULK Micromegas RD51.
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
On behalf of the LCTPC collaboration VCI13, February 12th, 2013 Large Prototype TPC using Micro-Pattern Gaseous Detectors  David Attié 
Construction and Characterization of a GEM G.Bencivenni, LNF-INFN The lesson is divided in two main parts: 1 - construction of a GEM detector (Marco Pistilli)
Report on very preliminary measurements of 10x10cm 2 Triple-GEM detectors with New Single Mask technique Overview Hole geometry Experimental setup Transparency.
Results on a Large Area triple-GEM Detector at LNF 5 th RD51 Collaboration Meeting Freiburg, 25 May 2010 D. Domenici - LNF.
Single GEM Measurement Matteo Alfonsi,Gabriele Croci and Bat-El Pinchasik June 25 th 2008 GDD Meeting 1.
Gas Electron Multiplier
Charge Diffusion, and Resistive Films Method’s, Math's, Monty Carlo’s, and Track reconstruction (with an M...) By: Stephen Turnbull.
MPGD TECHNOLOGIES AND PRODUCTION GEMMicromegas Resistive MSGC (NEW!) Rui De Oliveira 7/12/20111Rui De Oliveira.
Charge difussion through resistive strip read-outs. Javier Galan, G. Cauvin, A. Delbart, E. Ferrer-Ribas, A. Giganon, F. Jeanneau, O. Maillard, P. Schune.
TPC for ILC and application to Fast Neutron Imaging L. An 2, D. Attié 1, Y. Chen 2, P. Colas 1, M. Riallot 1, H. Shen 2, W. Wang 1,2, X. Wang 2, C. Zhang.
R&D activities on a double phase pure Argon THGEM-TPC A. Badertscher, A. Curioni, L. Knecht, D. Lussi, A. Marchionni, G. Natterer, P. Otiougova, F. Resnati,
First results from tests of gaseous detectors assembled from resistive meshes P. Martinengo 1, E. Nappi 2, R. Oliveira 1, V. Peskov 1, F. Pietropaola 3,
A Micromegas TPC for the ILC. 2 Introduction: Micromegas & TPC I. Micromegas ILC-TPC ILC & LP-TPC Beam test with Micromegas modules Test bench Ion backflow.
Max Chefdeville, NIKHEF, Amsterdam
GEM TPC Resolution from Charge Dispersion*
GEM and MicroMegas R&D Xiaomei Li Science and Technology
Large Prototype TPC using Micro-Pattern Gaseous Detectors
Activity of CERN and LNF Groups on Large Area GEM Detectors
Quality Control Chamber Production
Single GEM Measurement
Hybrid MPGD based photon detector, R&D update.
LABORATORI NAZIONALI DI FRASCATI
Updates on the Micromegas + GEM prototype
A novel gaseous X-ray polarimeter: data analysis and simulation
WG1 Task2 New structures, new designs, new geometries
THGEM: Introduction to discussion on UV-detector parameters for RICH
Micropattern Gas Detectors
Mircomegas - Gas gain simulation studies -
Same geometry, but different size of the rim
Potential Ion Gate using GEM: experiment and simulation
Numerical simulations on single mask conical GEMs
TPC Paul Colas Technical meeting, Lyon.
THGEM report – january, 22nd 2009
MWPC’s, GEM’s or Micromegas for AD transfer and experimental lines
Development of gating foils using FPC production techniques
Numerical simulations on single mask conical GEMs
Design of active-target TPC
Work report Miao NanNan
A DLC μRWELL with 2-D Readout
Gaseous detectors at the LHC experiments: GEM technology (lesson #3)
Presentation transcript:

Numerical simulations on single mask conical GEMs Tue 3rd March 2009, Bad Honnef Marco Villa – CERN

Micro Pattern Gas Detectors (MPGDs) My work @ CERN Large Area Micro Pattern Gas Detectors (MPGDs) Micromesh Gaseous Structure (MicromeGaS) Gas Electron Multiplier (GEM) R&D Data analysis R&D Simulations

The standard GEMs

Photolithographic technique used to prepare standard GEMs

Why simulations on conical GEMs? Why conical GEMs? Why simulations on conical GEMs? Large Area GEMs ↓ very difficult to align the two masks on the top and bottom side What are the properties of the GEM foils obtained with single mash lithographic technique? How do these properties depend on the geometry? spatial uniformity time stability discharge probability maximum achievable gain field shape electron transparency avalanche shape charging up properties

Simulations: basics Simulation ANSYS PACKAGE GARFIELD PACKAGE Ansys is used to define: the geometry; the material properties; the electrodes voltage; the e.m. boundary conditions; and to solve the e.m. equations with a finite elements analysis method GARFIELD PACKAGE Garfield is used to: read the Ansys fieldmaps; define the gas properties; simulate the behaviour of electrons in the gas

ANSYS(1): definition of the geometry Geometrical properties: kapton thickness = 50 µm copper thickness = 5 µm drift gap thickness = 8000 µm induction gap thickness = 8000 µm holes pitch = 140 µm hole smaller diameter = 55 µm hole larger diameter = 55 µm  95 µm In order to speed up the simulation, only the elementary cell has been considered the mesh density has been doubled on all the gas boundary surfaces

ANSYS(2): definition of the voltages At the beginning, test voltages have been used: drift field = 0.1 kV/cm induction field = 3 kV/cm GEM voltage = 20 V ↓ GEM field ≈ 3.6 kV/cm

GARFIELD(1): field and electrons drift

GARFIELD(2): field

ANSYS(3): re-definition of the voltages cathode 1MΩ GEM 1 top 0.5MΩ In the chamber: conversion gap = 3 mm transfer gap = 2 mm induction gap = 2 mm Therefore, the field values in the chamber are: drift field = 2.667 kV/cm induction field = 4 kV/cm GEM voltage = 366.7 V I ≈ 800 µA GEM 1 bottom 1MΩ GEM 2 top 0.5MΩ 5MΩ GEM 2 bottom 1MΩ GEM 3 top 0.5MΩ 2.5MΩ GEM 3 bottom 1MΩ anode to GND

GARFIELD(3): field and electrons drift

GARFIELD(4): field

GARFIELD(5): electron drift

GARFIELD(6): electron drift & diffusion Finally, the electron diffusion is implemented in the Garfield code a Monte-Carlo technique is used to simulate the longitudinal and transversal diffusion processes the Monte-Carlo integration step is set much smaller than the typical detector dimensions (good compromise = 250 nm)

GARFIELD(7): electron drift & diffusion

Preliminary conclusions Moving from the open-top geometry (95-55) to the cylindrical geometry (55-55) and then to the open-bottom geometry (55-95): the field peak @z=-25µm decreases, while the field peak @z=+25µm increases; if the thermal electron diffusion is switched off, the electron transparency decreases from 95-55 to 55-55, then it increases slightly; if the diffusion is off, all the stopped electrons end up on the upper copper surface  meshing problem? if the diffusion is off, the diameter of the outcoming electron beam decreases from 95-55 to 55-55, then is remains constant; the Monte-Carlo diffusion technique seems to work fine  is there any real need for a microscopic diffusion procedure?

implementation of the avalanche process (Monte-Carlo?) Next steps… check the beaviour of a microscopic diffusion process and compare the results with the Monte-Carlo method; electron transparency study using electrons from random coordinates on a far plane (100 µm over the upper copper foil); implementation of the avalanche process (Monte-Carlo?) charging up studies