Particle Physics and Particle Counting for IH&S and IAQ

Slides:



Advertisements
Similar presentations
An innovative tool for the review of health and safety work practices and the implementation of effective controls of particulate exposures.
Advertisements

Systems and sensors Dr. Bertrand Dano ©Altapic.com, 2014.
9. Mine Aerosol Measurements Health harzard in exposure to respirable mineral aerosol: 1. Pneumoconiosis โรคปอด 2. Asthma โรคหืด 3. Emphysema การพองลมของเนื้อเยื่อหรือถุงลม.
Real-time Corrosion Product Transport Monitoring Using On-line Particle Monitors Joe Zimmerman Chemtrac Systems, Inc. Norcross, GA.
Fundamentals of Industrial Hygiene 6 th Edition Chapter 8: Particulate Matter Compiled by Allen Sullivan, Assistant Professor, Safety and Health Management.
Photoacoustic Multi-gas Monitor , page 2 Photoacoustic Multi-gas Monitor 1312 Portable monitor for quantitative analysis of up to 5 gases and.
IAQ Sampling Document a condition or state of the space –Adequate ventilation –Comfort Identify source of contamination –Leakage –Products.
Nephelometer Introduction & Operation. What is a Nephelometer? The Nephelometer is an analytical instrument used to measure the light-scattering coefficient.
© 2011 Cemtek Environmental, Inc. Particulate Matter Monitoring Technologies and Detection Principles CEMTEK Environmental Inc S. Orange Ave. Santa.
Atmosphere Sciences Instrumentation Lab Organized by David Delene - November 20, 2008 Overview of Instruments – 3:00 Clifford Hall 470 Lab Demonstrations.
1 Motivation Particles are generally regarded as one of the most serious indoor air quality concerns Increasing concern about ultrafine particles Very.
HYGIENE CONTROL IN THE BREWING INDUSTRY
Presented to: Name of Customer Enhanced MET ONE 3400 Series Portable Airborne Particle Counters.
Evaluation of Simultaneous PM10, PM2. 5, and PM10-2
Continuous Ambient Particulate Monitors A Review of Current Technologies by Michael Corvese, Product Manager Thermo Electron Corporation Air Quality Instruments.
Introduction to Thermo Electron Instruments Robert Kinsella Sky Patton Thermo Electron.
Site-Specific Management Factors influencing plant growth Water Light Temperature Soil Compaction Drainage.
Biogas Technology Presented by:. Founded in 1988, now serving Global Customer Base Founded in 1988, now serving Global Customer Base Corporate Office.
1 Worldwide Solutions Confidential SOLAIR Particle Counter.
Introduction to BGI Instruments
High Sensitivity Smoke Detection
Measurement of total mass concentration. 1. Sampling probe - Isokinetic or sampling from still air 2. Flow rate - Rotameter or digital flowmeter 3. Filter.
Introducing the new HIAC and PharmSpec 3.0
Continuous Particulate Monitoring Using Light Scatter Photometers.
Basic Laws of Gases and Particulates
Industrial Hygiene Indoor Particles: Technology Copyright © 2008 by DBS.
Market Leader in TOC Analysis ANATEL HIAC MET ONE Global Innovator in Fluid Particle Applications Leader in Airborne Particle Counting PharmSpec 3.0 HIAC.
Measuring Particle Pollution ITEP Air Quality Training Kodiak 2015
The Theory of Near Light Scatter
Measurement Equipment
Sampling Methods. Sampling Purpose –Detect and quantify –Identify sources/amplification –Assess potential virulence –Assess effectiveness of controls.
1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Technology Requirements for Online Testing Training Module Please refer to the revision log on the last slide of this presentation, updated August.
Incubator Structure An overview of the mechanics of incubators supplied by Research Instruments in the UK & Ireland With thanks to Astec Japan Co- author.
Thomas M. Canty, P.E. J.M. Canty Inc. Buffalo, NY
NAFA Guide To Air Filtration
Cold-Chain Expert, Total Solution Quality Precision Service Value
Hydromet Cloud Presentation
NANOPARTICLES: A PRIMER FOR GENERAL PRACTITIONERS
GammaTRACER Key features
2.1 & 2.2: Rainfall Detection and Alarm System
Filter Media-PVC.
Advancements in Fuel and Lube Oil Inspection Technology
Topic 6 : Atomic and Nuclear Physics.
TrueView People Counter
Reveal™ Touch Screen Product Overview
LIGHTHOUSE Clean Room Technology
Assessment of Safety and Physical Environment factors in Governmental Primary Schools in Dammam Farhan M Al-Anezi.
Measurement of Transport in the PME EPA03 Task 2.B
PORTABLE HIGH-SPEED GAS CHROMATOGRAPH
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
Session 4: Air Pollution Measurements
SEDIMENTATION 9/11/2018.
Filter Installation Leak Testing
To change picture – with LCD view.
August 23, 2000 R.N. Dubois Dow Chemical
Inline System to Detect Hydrates, Wax and Sand Thomas M. Canty PE J. M
Laura Lund University of Arizona Dr. William Conant
Controlling Sensors Efficiently with MCUs
Instrumentation and control
Aerosol Drug Therapy Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc.
There are two kinds of radiation monitors used for medical purposes: survey monitors personal monitors.
Bracelet Hardware Platform Implementation and Data Analysis
Bathless Tablet Disintegration Instrument with Auto Endpoint Detection
Lab 7– Powder Micromeritrics
Palm-Top USB Radiometer/Photometer
Chapter 3 Particle Sizing.
Operating environment:
Power monitoring software
Presentation transcript:

Particle Physics and Particle Counting for IH&S and IAQ Thomas J. Grillo, Jr. Particles Plus, Inc.

Overview Particle Behavior Particle counters & what are we detecting Types of Particle Counters Typical Features and Operation Q & A

Particles and their behavior Particles come in all different types, shapes and sizes. A human hair is 80-100 µm in size The human eye can see 40 micron size particles Particle size effects their behavior Gravity vs. Brownian Motion Effect Settling rate influenced by size, shape, and density. Particles relative to Indoor Air Quality & IH&S Particles can deposit in human lungs Particles affect human health size and shape affect IAQ performance

Particles and their behavior Brownian Motion Smaller particles and atoms influence larger particles’ direction and speed of motion in a liquid or gas Gravity Particles > 5.0 µm – falling debris Partilcles < 5.0 µm – tendency to remain airborne - suspension Aerodynamic shape and density play a role Environmental influences Airflow/Ventilation/Occupancy

Air Quality Monitoring

What is a Particle Counter – How it works A particle counter is an instrument or sensor that detects and counts physical particles. The nature of particle counting is based upon either light scattering, light obscuration, or direct imaging. A high intensity light source (typically a laser) is used to illuminate particles as they pass through the detection chamber. As a particle passes through the light source and if light scattering is used, then the redirected light is detected by a photo detector. (Wikipedia)

Why use a particle counter? Detect Monitor Analyze Remediate and Prevent

Why use a particle counter? To provide a quantitative analysis of airborne particulate for quality control regulatory requirements for public health and safety limiting liability Monitoring for employee (or occupant) health and safety Air Quality Analysis for resolving & remediating

Types - Air Quality Monitors Used to monitor in fixed location for long term analysis Includes Particulate, Temp, RH, CO2 & TVOC

Types - Handheld Particle Counters Mobility – Ideal for site investigation Establish a baseline for airborne particulate levels. Post remediation checks before clearance testing.

Types - Remote Particle Counters Wall mount versions for fixed construction barrier applications Long term onsite analysis for PM or direct counts

Types – Dust Monitors Most prevalent in IH&S applications for mass concentration measurments Limited by mechanical impactors or cyclones

Types – Gravimetric Sampling Fixed flow pumps with impactors or cyclones utilizing pre-weighed filter media that can collect a sample over time and the weight can be rechecked by a lab for a value in mass concentration (µg/m³) Can also be evaluated by Microscopy for quantitative and qualitative analysis.

Types – other technologies – R&D Differential Mobility Analyzers CPC - Condensate Particle Counter Piezo Balance – Wetted particles CPC – Quantitative only Beta Ray Attenuation – continuous outdoor monitoring

Air Quality Monitoring Using a Particle Counter Air Quality Monitoring

User Interface – Main Screen The instrument calculates Count/M³ based on the Flow rate of the instrument and the duration of the sample 0.3 = 583,392 0.5 = 50,976 1.0 = 25,134 2.5 = 6,726 5.0 = 1,770 10.0 = 354 Displaying Raw Counts in both cumulative and differential counts

Understanding ISO 14644-1 Particle Counts

User Interface – Main Screen

User Interface – Air Quality Monitoring

User Interface – Geiger, Beep or Real-time Meter Modes Provides a auditory (or visual and auditory) means of displaying current particle count activity that can be used to help locate particulate sources (shown with range slider to adjust sensitivity)

Sampling and Logging Log individual data records Locations and recipes Newer features like annotations and on screen statistics

Processing Power More advanced with multiple microprocessors onboard Allows for simultaneous processing of particle counts, accessing settings, viewing saved records, downloading data, and supporting many communications sessions. Concurrent Communications interfaces include: Multiple Modbus sessions (wired and WiFi) Multiple web-server sessions (wired and WiFi) USB data-download and configuration USB printer or thumb-drive

Intelligent Peripherals Swappable peripherals allow more flexibility for each instrument – other environmental or air flow related. Allows instrumentation to be configured for the task-at-hand (IAQ, H&S, QC, Certification & Validation) Allows instruments to expand over time to add new features – handheld probes, etc.

Instrument Management Software Real-time graph allows for instrument operation and control Saves data for historical review, reporting and analysis

Instrument Management Software Self-calibration of TVOC, CO2, Temperature and Humidity sensors Allows for remote service and upgrades

Q&A Thank You! www.particlesplus.com