BTF microbunching structure with Micro-Channel Plate PMT

Slides:



Advertisements
Similar presentations
Sci-Fi tracker for IT replacement 1 Lausanne 9. December 2010.
Advertisements

COSMIC RAY MUON DETECTION USING SCINTILLATION COUNTER AND WAVELENGTH SHIFTING FIBERS ARUNODAYA BHATTACHARYA VSRP-2009,TIFR,MUMBAI 6/7/09.
May 14, 2015Pavel Řezníček, IPNP Charles University, Prague1 Tests of ATLAS strip detector modules: beam, source, G4 simulations.
Photodetector Timing Resolution Burle Micro-Channel Plate Photo Multiplier Tubes (MCP-PMTs) H. Wells Wulsin SLAC Group B Winter 2005.
Performance of MPPC using laser system Photon sensor KEK Niigata university, ILC calorimeter group Sayaka IBA, Hiroaki ONO, Paul.
Study of Photon Sensors using the Laser System 05/7/12 Niigata University, Japan Sayaka Iba, Editha P. Jacosalem, Hiroaki Ono, Noriko.
1 Veto Wall Test Hyupwoo Lee MINERvA/Jupiter Group Meeting June 20, 2007.
INFN of Genova, Pavia and Roma Flavio Gatti, PSI, February 9 th, Timing Counter status Timing Counter status.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
3 F. Iacoangeli, 1 D. Breton, 1 V. Chaumat, 3 G. Cavoto, 1 S. Conforti Di Lorenzo, 1 L. Burmistrov, 3 M. Garattini, 1 J. Jeglot, 1 J. Maalmi, 2 S. Montesano,
Study of HF pmt high tail signal FNAL: Jim F, Rick Vidal Iowa: Ugur Akgun, Asli Albayrak, Warren Clarida, Antony Moeller, Yasar Onel, Justin Parsons, Taylan.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
Catania VLVnT09 Athens, Greece 1/14 Catania Performances of four super bialkali large area photomultipliers with respect to.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
Blair Ratcliff2 nd Workshop on SuperB, Frascati, March Status Update: the Focusing DIRC Prototype at SLAC Blair Ratcliff Blair Ratcliff Representing:
14/02/2007 Paolo Walter Cattaneo 1 1.Trigger analysis 2.Muon rate 3.Q distribution 4.Baseline 5.Pulse shape 6.Z measurement 7.Att measurement OUTLINE.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Feb 10, 2005 S. Kahn -- Pid Detectors in G4MicePage 1 Pid Detector Implementation in G4Mice Steve Kahn Brookhaven National Lab 10 Feb 2005.
“End station A setup” data analysis Josef Uher. Outline Introduction to setup and analysis Quartz bar start counter MA and MCP PMT in the prototype.
R&D of MPPC for T2K experiment PD07 : Photosensor Workshop /6/28 (Thu) S.Gomi T.Nakaya M.Yokoyama H.Kawamuko ( Kyoto University ) T.Nakadaira.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Simonetta Gentile, LCWS10, March 2010, Beijing,China. G-APD Photon detection efficiency Simonetta Gentile 1 F.Meddi 1 E.Kuznetsova 2 [1]Università.
8 July 1999A. Peisert, N. Zamiatin1 Silicon Detectors Status Anna Peisert, Cern Nikolai Zamiatin, JINR Plan Design R&D results Specifications Status of.
V0, jyg, ALICE week, March Preparing for the V0 TDR (Lyon-Mexico project)  The V0 detector in 3 chapters  1 - Tests and simulations of detection.
DEAR SDD --> SIDDHARTA
Status of photon sensor study at Niigata University -- SiPM and MPPC -- Photon sensor mini workshop 05/9/16 University Niigata University.
Catania 11 ICATPP october, 2009 Como 1/12 Catania Comparative measurements of the performances of four super bialkali large.
1 Calorimeters LED control LHCb CALO meeting Anatoli Konoplyannikov /ITEP/ Status of the calorimeters LV power supply and ECS control Status of.
Charles University Prague Charles University Prague Institute of Particle and Nuclear Physics Absolute charge measurements using laser setup Pavel Bažant,
11 October 2002Paul Dauncey - CDR Introduction1 CDR Introduction and Overview Paul Dauncey Imperial College London.
DREAM December 07 BGO Data Analysis based on QADC Signals L. La Rotonda, E. Meoni, A. Policicchio, G. Susinno, T. Venturelli Calabria University & INFN.
Genova/Pavia/Roma Flavio Gatti, PSI, 11 February, Timing Counter: january 2004.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
Development of the CpFM at INFN Rome Test BTF October 2013 Marco Garattini INFN - Roma “La Sapienza” CERN – 5-7 November 2013 – UA9 Collaboration meeting.
The VSiPMT: A new Generation of Photons Detectors G. Barbarino 1,2, F. C. T. Barbato 1,2, R. de Asmundis 2, G. De Rosa 1,2, F. Di Capua 1, P. Migliozzi.
Update on works with SiPMs at Pisa Matteo Morrocchi.
Characterization of Hamamatsu R12199 PMTs Oleg Kalekin KM3NeT Meeting CPPM, Marseille
- Herve Grabas - Ecole Superieure d’Electicite 1 Internship presentation - University of Chicago – 3 sept
Philip Bambade, Pierre Barillon, Frédéric Bogard, Selma Conforti, Patrick Cornebise, Shan Liu, Illia Khvastunov Journée PHIL
Transverse Coherent Transition Radiation (TCTR) Experiment First Ideas for a Measurement Setup Max-Planck-Institute for Physics Munich Olaf Reimann, Scott.
TCT measurements with strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž 1,2, Marko.
A.PasseriHigh granularity Pb-SciFi calorimeter1 Construction and tests of a fine granularity lead-scintillating fibers calorimeter P.Branchini, F.Ceradini,
Proposal for the after-pulse effect suppression  Observation of pulses and after-pulses  Shape measurement  Algorithm  Results  Efficiencies for after-pulse.
First BTF Users Workshop 6-7 May Laboratori Nazionali di Frascati Marco Garattini on behalf of the UA9 Cherenkov detector team 3 M. Garattini, 1.
1 SuperB-PID, LNF 4/4/2011 MAPMTsSilvia DALLA TORRE COMPASS experience with HAMAMATSU MAPMTs S. Dalla Torre.
F. Iacoangeli, on behalf of the UA9 collaboration INFN - Roma La Sapienza, Italy An in-vacuum Cherenkov detector for proton Flux Measurement (CpFM) for.
Ultra Cherenkov based SAC
Fabio, Francesco, Francesco and Nicola INFN and University Bari
Plans for this week MWPC: wire stretching today
Frontier Detectors for Frontier Physics, Elba, Italy, May 2015
Scintillation Detectors in High Energy Physics
Ultra fast SF57 based SAC M. Raggi Sapienza Università di Roma
Evidence for direct detection of ionizing particles in SiPMs
FINAL YEAR PROJECT 4SSCZ
Timing Counter: progress report
Start Detector for pion experiments
Update of time measurement results with the USB WaveCatcher board & Electronics for the DIRC-like TOF prototype at SLAC D.Breton , L.Burmistov,
HEPD BTF and Trento Facility Calorimeter preliminary results
Ioannis Manthos Laboratory of Nuclear & Particle Physics
Explicitly Radiation Hard Fast Gas Cerenkov Calorimeter
Instrumentation for Colliding Beam Physics 2017
Timing Counter Sept CSN I, Assisi 2004 Giorgio Cecchet.
The Pixel Hybrid Photon Detectors of the LHCb RICH
Department of Physics and Astronomy,
Progress on the Focusing DIRC R&D
PID electronics for FDIRC (Focusing Detector of Internally Reflected Cherenkov light) and FTOF (Forward Time of Flight) Christophe Beigbeder and Dominique.
High Rate Photon Irradiation Test with an 8-Plane TRT Sector Prototype
Variable distance from beam.
The LHCb Front-end Electronics System Status and Future Development
Presentation transcript:

BTF microbunching structure with Micro-Channel Plate PMT Francesco Iacoangeli, Gianluca Cavoto INFN – Roma

Introduction A prototype for the Cherenkov detector for proton Flux Measurement (CpFM) of UA9 experiments was tested in October 2013 at the Frascati BTF. See M.Garattini’s talk. The aim of test beam was to measure the performance of optical coupling and the detection efficiency of a CpFM prototype. Some different setups were studied. The angular scan and intensity scan were run so as to find the best configuration for final CpFM of UA9. During system’s characterization the structure of microbunching appears on the waveforms

Detector The CpFM prototype is made up of a fused silica radiator and a Micro-Channel Plate photomultiplier (MCP) coupled together (directly or through a fiber bundle). Fibers/MCP adapter Fiber Bundle Cerenkov Radiator MCP hamamatsu R3809U Series Holder with thin window

Cerenkov radiator The used Cerenkov radiator has a geometrical coupling not optimized The Cerenkov detected light per electron depends on details of light reflection and diffusion in the radiator and at the radiator-PMT interface Radiator surface 21 mm MCP Area 11mm

Photo detector Micro Channel Plate Hamamatsu PMT with Fast Time response: Pros: -Typical Rise Time: 150ps -Typical Fall Time: 350ps FWHM < 50ps Low noise Cons: The effective photocathode area is a circle with diameter 11mm  Only a part of Cerenkov radiator is coupled (11mm x 21mm rectangular section)

Readout electronics Oscilloscope Lecroy WaveRunner 6 Zi : Bandwidth : 1Ghz Resolution: 8-bit Sample rate: 10 Gsample/s The bandwidth and the sample rate of oscilloscope isn’t optimal to see the microbunching structure

Hand Platform Rotation Stage Test Setup BTF Calo (Pb Glass Cerenkov) Čerenkov Radiator Oscilloscope MCP-PMT Signal Ethernet Beam window Control Room PC Hand Platform Rotation Stage

Typical Waveform 5 e- event Volt 5 e- event 100ps/div - Due to fast time response of MCP-PMT, Waveforms can show the peak of each micro bunch. - The measured charge of each peak should be proportional to number of electrons contained in the micro-bunch

Given the type of waveform the total charge of the signal is more significant than its amplitude Unfortunately in the tested configuration the charge of a single particle event is significantly fluctuating Nevertheless we tried to understand if it’s possible to use the CpFM to study the microbunching structure of BTF beam

Charge distribution Ne=1.5 Ne=1.5 Charge was calculated on a 40ns window centered on pulse minimum Events with zero electron was suppressed The plot of charge for nominal multiplicity of 1.5 e- shows the CpFM (MPC plot) isn’t good to discriminate single electron events

Charge resolution Ne=1,5 Ne=1,5 RMS/mean=0,16 RMS/mean=0,57 We considered the events selected by the first peak of CALO charge spectrum in order to estimate the resolution on single particle regime of CpFM RMS/mean ratio value shows a big variance for CpFM with single electron events.

Efficiency Efficiency=1- (MPC pedestal events) −(Calo pedestal events) Events –(Calo pedestal events) = 0,79 Ne=1,5 Ne=1,5 Overflow Events=1377 Overflow Events=3329 - pedestal values of charge for CALO and MPC were cut The ratio of efficiency of CpFM , normalized on CALO no-zero e- events is: 79%

Waveform persistence CpFM - Ne=35e- events CpFM zoomed - The persistence of waveform show that the CpFM prototype can discriminate the distribution of particles within the 10ns long bunch CALO - We found a two-peak shape of distribution that need to be explained (maybe due to gun RF ripple ?)

Time measurements MCP threshold CALO threshold Single Electron Event The thresholds to perform time measurements were selected depending on minimum observed signal in single particle regime but to reject background The values of threshold were fixed for all multiplicity of beam.

Time distribution The delay between Trigger (LINAC NIM trigger signal) point out the time distribution of particles on the 10 ns bunch. Ne=1,5 10 ns We don’t know the cause of the 2 distinct distributions on CALO delay histogram,. Ne=1,5 10 ns

Time resolution - Time resolution measurements were performed with multi-particles events (Ne=236) so as to have at least 1 particles in the first microbunch. RMS=266ps Ne=236 RMS=455ps 10 ns In this case too, we don’t know the cause of the 2 distinct distributions 20 ns We measure the delay from trigger edge (LINAC NIM Timing signal) of the first particle of each event The CpFM take out a distribution similar to the CALO’s one but by far less light

Conclusions The CpFM prototype was not optimized to perform time measurements and readout electronics bandwidth should be upgraded for fast timing signal, nevertheless we can recognize the microbunching beam structure Efficiency and resolution are quite affected by fluctuation on light detection: a suitable geometric coupling can decrease the ligth loss Performing a new data-taking, with a better geometrical match and fast timing readout electronics, will be good to improve the measurement the microbunching structure Eventually this system could be integrated as a BTF beam monitor detector.

SPARE

BTF Setup Diamond LAL Cerenkov INFN Cerenkov e- Beam BTF Remote Control Table BTF Calorimeter

Geometrical efficiency and optical coupling Bundle of fiber spot Lower light collection efficiency due to geometry: MCP-PMT area: π(11mm/2)2=95 mm2 Fibers cable area: 25π*(0.6mm/2)2=7.07mm2 Geometrical efficency ratio: 7/95 = ~7 % 10 mm 20 mm 75 mm ± 5 mm Electron’s beam Remaining efficiency losses due to optical coupling and fibers attenuation = 7/3.3 = ~ 50 %

Direct contact VS Fibers 47˚ (normalized to electron path length into the radiator) Charge per Electron Radiator/beam angle With fibers bundle the light detected per electron are 30 times less

Radiator with fibers bundle Charge per Electron (normalized to electron path length into the radiator) 47° Radiator/beam angle

Fiber’s bundles Bandle 1: Bandle 2: Fibers: Fibertech Type AS600/660 UVST Coating 780 μm Silicone Jacket 940 μm Tefzel 0.6 dB/m at 350 nm We tested 2 different bundles of same fibers Bandle 1: Homemade Fibers hand-cut by diamond wheel lapped with glass sand papers with increasingly grit (400 - 1200) Length: ~ 13 cm Bandle 2: Manufactured by Fibernet lapped with industrial lapping process Length: ~ 47cm 1 fiber cracked on manufacturing 

Time precision The separated plot of each distribution show a RMS of 266ps for the first and of 455ps for the second. This is promising to repeating the measure with more performing readout electronics

Time distribution 1e- Ne=1 10 ns measure window 10 ns