Calibration of the PEPPo Polarimetry (a tale of two polarimeters)

Slides:



Advertisements
Similar presentations
Journées Instrumentation du GDR Nucléon 8-9 Avril 2008, CEA Saclay Polarized Positrons at the Jefferson Laboratory (i) Physics motivations (ii) Principe.
Advertisements

POLARIMETRY of MeV Photons and Positrons Overview Beam Characterization – undulator photons – positrons Basics of the Transmission Method – for photon.
Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 1 Spin Dance.
Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy 1 Spin Dance.
Compton integrating method Beam test summary PREX/Happex Collaboration Meeting Alexandre Camsonne.
Measuring the Neutron and 3 He Spin Structure at Low Q 2 Vincent Sulkosky College of William and Mary, Williamsburg VA Experimental Overview The.
Measuring the Neutron and 3 He Spin Structure at Low Q 2 Vincent Sulkosky for the JLab Hall A Collaboration College of William and Mary, Williamsburg VA.
5 MeV Mott Measurement for CEBAF Operations group Joe Grames, Marcy Stutzman February 14 th, 2007 Sir Nevill F. Mott at the ceremony with his Nobel Prize.
5 th Rencontres du Vietnam - Aug. 7, 2004 Polarized Positrons…E166 A.W.Weidemann 1 Introduction (What, who) Motivation (Why) Experiment and Polarimetry.
Left: The polarization of the undulator radiation as a function of energy. Right: Calculated positron longitudinal polarization as a function of energy.
K. LaihemE166 collaboration LCWS06 Bangalore March 12th 2006 The E166 experiment Development of a polarized positron source for the ILC. Karim Laihem on.
Undulator-Based Production of Polarized Positrons An experiment in the 50 GeV Beam in the SLAC FFTB E-166 Undulator-Based Production of Polarized Positrons.
Undulator-Based Positron Production in the Final Focus Test Beam (E-166) K.T. McDonald, J.C. Sheppard, Co-Spokespersons SLAC Experimental Program Advisory.
Prajwal T. Mohan Murthy Laboratory for Nuclear Science, MIT νDM Group Spin-Light Polarimeter for the Electron Ion Collider EIC Users Meeting 2014 Jun 2014.
M. Woods (SLAC) Beam Diagnostics for test facilities of i)  ii) polarized e+ source January 9 –11, 2002.
AESOP: Accurate Electron Spin Optical Polarimeter Marcy L. Stutzman, Matt Poelker; Jefferson Lab Timothy J. Gay; University of Nebraska.
Polarized Electrons for Polarized Positrons A Proof-of-Principle Experiment P. Adderley 1, A. Adeyemi 4, P. Aguilera 1, M. Ali, H. Areti 1, M. Baylac 2,
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
Beijing, Feb 3 rd, 2007 LEPOL 1 Low Energy Positron Polarimetry for the ILC Sabine Riemann (DESY) On behalf of the LEPOL Collaboration.
Positron Beam for Measurements of Generalized Parton Distributions Generalized Parton Distributions e JLab (i) Generalized parton distributions (ii)
Diana Parno – July 22, 2008 January PREx Test Run: Compton Photon Analysis Diana Parno Carnegie Mellon University HAPPEX Collaboration Meeting.
A study of systematic uncertainties of Compton e-detector at JLab, Hall C and its cross calibration against Moller polarimeter APS April Meeting 2014 Amrendra.
Polarimetry at the LC Source Which type of polarimetry, at which energies for LC ? Sabine Riemann (DESY), LEPOL Group International Workshop on Linear.
Status of the PrimEx Experiment: A Precision Measurement of the Neutral Pion Lifetime 7 th European Conference on “Electromagnetic Interactions with Nucleons.
12 GeV CEBAF INJECTOR Reza Kazimi Users Group Annual Meeting June 4, 2012.
1 The Longitudinal Polarimeter at HERA Electron Polarization at HERA Laser System & Calorimeter Statistical and Systematic Precision Laser Cavity Project.
PrimEx collaboration meeting Energy calibration of the Hall B bremsstrahlung tagging system using magnetic pair spectrometer S. Stepanyan (JLAB)
Electron Detection for Compton Polarimetry Michael McDonald Outline -Compton Effect -Polarimetry -Detectors -Diamond Results.
Undulator-Based Positron Production in the Final Focus Test Beam (E-166) The International Polarized Positron Production Collaboration K.T. McDonald, J.C.
Polarimetry Report Sabine Riemann on behalf of the DESY/HUB group January 24, 2008 EUROTeV Annual Meeting, Frascati.
ILC/CLIC e + generation working group Jim Clarke, STFC Daresbury Laboratory and Louis Rinolfi, CERN.
E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.
Diana Parno – 18 April 2009 Compton Photon Detector Upgrade Diana Parno 18 April 2009 HAPPEX Collaboration Meeting.
Polarized Positrons at the Jefferson Laboratory Idaho State University, Idaho Accelerator Center, Jefferson Lab, LPC Clermont-Ferrand, LPSC Grenoble, Old.
(i) Physics motivations (ii) The PEPPo experiment (iii) PEPPo measurements (iv) Outlook Eric Voutier Institut de Physique Nucléaire d’Orsay Orsay, France.
Polarized Positrons at the Jefferson Laboratory Idaho State University, Idaho Accelerator Center, Jefferson Lab, LPC Clermont-Ferrand, LPSC Grenoble, Old.
EIC Users Meeting, SBU, 6/27/14 Polarized Electron Beams in the MEIC at JLab Fanglei Lin for MEIC Study Group EIC Users Meeting, Stony Brook University,
R.Chehab/ R&D on positron sources for ILC/ Beijing, GENERATION AND TRANSPORT OF A POSITRON BEAM CREATED BY PHOTONS FROM COMPTON PROCESS R.CHEHAB.
Polarized Electron Footprint at JLab P. Adderley, J. Clark, J. Dumas ǂ, A. Freyberger, J. Hansknecht, J. Grames, M. Poelker, K. Surles-Law, M. Stutzman,
PAC38, Newport News, August 22-26, 2011 PEPPo a Proof-of-Principle Experiment Polarized Electrons for Polarized Positrons A. Adeyemi 4, P. Aguilera 1,
? Users Town MeetingNewport News, March 16, 2012 Polarized Positrons for Nuclear Physics at Jefferson Lab (i) Electromagnetic form factors (ii) Generalized.
Mott Electron Polarization Results Riad Suleiman July 10, 2013.
Operated by Jefferson Science Associates, LLC for the U.S. Department of Energy Thomas Jefferson National Accelerator Facility Polarized Electron Beams.
Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy The Department.
Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Thomas Jefferson National Accelerator Facility M. Baylac,
Dollan, Laihem, Lohse, Schälicke, Stahl 1 Monte Carlo based studies of polarized positrons source for the International Linear Collider (ILC)
Pb-Parity and Septum Update Presented by: Luis Mercado UMass - Amherst 12/05/2008 Thanks to Robert Michaels, Kent Pachke, Krishna Kumar, Dustin McNulty.
PRE-CONCEPTUAL DESIGN OF A CW POSITRON SOURCE FOR JLAB (2013-LDRD-02) JOE GRAMES LDRD PROPOSAL REVIEW - JULY 17, 2013 PROJECT OVERVIEW THE TEAM LDRD EVALUATION.
CsI(Tl) Calorimeter and status of the E166 experiment E166 experiment CsI ( Tl) calorimeter construction. Test beam results vs. Geant4 simulation Schedules.
Prospects for Positron Beams at JLab e JLab (i) Physics motivations (ii) Polarized positron production (iii) PEPPo (iv) Perspectives (v) Conclusions.
PEPPo a Proof-of-Principle Experiment
LDRD Brainstorming Session
Proton Form Factor Ratio GE/GM from Double Spin Asymmetry with
Polarized Electrons for Polarized Positrons
Mott Polarimeter at CEBAF
Polarized Electrons for Polarized Positrons
A.P. Potylitsyn, I.S. Tropin Tomsk Polytechnic University,
Production of Highly Polarized Positrons MeV Polarized Electrons
ILC/CLIC e+ generation working group
CEBAF Injector Overview
Magneto-Optic Kerr Effect in a Magnetized Electron Gun
5 MeV Mott Measurement for CEBAF Operations group
PEPPo Experiment Readiness Review
QWeak Collaboration Meeting
E166 - LEPOL - Low Energy Positron Polarimetry for the ILC
Polarized Positrons at Jefferson Lab
Production of Magnetized Electron Beam from a DC High Voltage Photogun
HyCal Energy Calibration using dedicated Compton runs
ILC Baseline Design: Physics with Polarized Positrons
PEPPo : Polarized Positron Production
Presentation transcript:

Calibration of the PEPPo Polarimetry (a tale of two polarimeters) Adeleke Adeyemi On behalf of PEPPo collaboration 22nd International Spin Symposium, September 26, 2016

The PEPPo Concept The PEPPo (Polarized Electrons for Polarized Positrons) experiment was conducted in the injector of the CEBAF accelerator at JLab to demonstrate a new technique for the production of polarized positrons. It involves a two-step process: Creation of circularly polarized photons from the bremsstrahlung produced by longitudinally polarized electrons in a hi-Z target. Followed by the creation of polarized e+e- pairs via the pair production from these circularly polarized photons within the same target.

PEPPo Experimental setup Mott polarimeter for electron polarization measurement PEPPo Compton polarimeter for positron polarization measurement Tungsten Target For more on the PEPPo experiment: See Grames talk on Thursday

Electron beam polarization Pe- = 83.7% ± 0.6% (stat) ± 0.7% (sys) Compton Transmission Polarimetry Electrons or Positrons radiate polarized photons by Bremsstrahlung in reconversion target. The photons transmitted by the magnetized iron core of the analyzing magnet are detected in 9 crystals of photon calorimeter and are read by PMTs The measurement of the beam (positron or electron) polarization is essentially obtained from the transmission asymmetry (AT) of the number of transmitted bremsstrahlung photons for oppositely polarized target or beam polarization orientations. 𝜸 μ1 - Compton absorption coefficient L - target length P3 - photon polarization (long.) e- Pe- e+ Pe+ Pe – e-/e+ polarization PT - target polarization Ae - analyzing power Target Electron beam polarization Pe- = 83.7% ± 0.6% (stat) ± 0.7% (sys) Target polarization PT = 7.06% ± 0.05% (sys1) ± 0.07% (sys2)

Compton Transmission Polarimeter Reconversion target 2 mm × 48 mm diameter tungsten composite (Densimet D17K) with 90.5% W,7% Ni and 2.5% Cu. Analyzing magnet The core of the analyzing magnet is a magnetized iron cylinder target that is 7.5 cm long and 5 cm diameter Photon calorimeter 9 (60 x 60 x 280 mm) Cesium Iodide crystals doped with Thallium CsI(Tl) arranged in 3 × 3 array configuration. CsI(Tl) crystals are coupled to Hamamatsu R6236 PMTs operated at -1.5kV Hamamatsu R6236 FADC 250 The signal from the PMTs are fed into JLab custom made FADC250 module which samples signals at 250 MHz.

Analyzing magnet The iron core target is equipped with 3 pick-up coils measuring the magnetic flux generated by the magnet current variation (ramping-up, polarity reversal). Specific cycling procedures are used during the experiment to monitor the target polarization. The magnetic field of the analyzing magnet was modeled in OPERA 2D and compared to field values measured experimentally with the pick up coils. PT = 7.06% ± 0.05%Stat. ± 0.07%Syst. E. Froidefond, E. Voutier, PEPPo TN-14-02 (2014)

Analyzing magnet response Experimental asymmetries are measured with respect to beam helicity ; they are linearly proportional to the target polarization, itself proportional to the target magnetization. 𝑨 𝑻 = 𝑵 + − 𝑵 − 𝑵 + + 𝑵 − = 𝑷 𝒆 𝑷 𝑻 𝑨 𝒆 IHWP inserted

Analyzing power simulation The analyzing power of the polarimeter can be experimentally measured with a known polarized beam or simulated with GEANT4. A model of the PEPPo polarimeter has been developed within the GEANT4 framework, starting from E-166 Collaboration earlier work. The simulated energy deposited into each crystal is processed according to the data read-out electronics method Simulation of 5.34MeV/c pencil beam e+ beam

Simulated Positron Analyzing power Positron analyzing power simulation: 3.08 - 7.19MeV/c. Positron analyzing power is obtained directly from simulation. The main difference between electrons and positrons is the annihilation reaction.

Energy Integrated Asymmetry Electron data are recorded in energy integrated mode. The energy integrated method is suitable for the high rate condition of the electron. The total energy deposited in each crystal during the time corresponding to a single helicity state of the initial electron beam is recorded. Helicity frequency=30Hz Helicity delay= 8windows Helicity pattern=quartet ( + - - + or - + + - ) h- h+ h+ h- E- E+ E+ E- Helicity +1 Simulation Helicity -1

𝑨 𝒆 = 𝑨 𝑻 𝑷 𝒆 𝑷 𝑻 Electron physics asymmetry measurement. Combining experimental asymmetries measured for each analyzing magnet polarity and each laser polarization orientation allows to cancel-out eventual false asymmetries and isolate physics asymmetries. Pe- (MeV/c) Ie- @ T2 3.08 60 pA 4.02 23 pA 5.34 25 pA 6.25 10 pA 7.19 𝑨 𝒆 = 𝑨 𝑻 𝑷 𝒆 𝑷 𝑻

Electron Measured vs. Simulation The calibration of the analyzing power of the polarimeter relies on the comparison between experimental and simulated electron analyzing power. The comparison between experimental and simulated analyzing power allows to benchmark the GEANT4 physics packages Agreement between simulation and measurement is best for central crystal; outer crystals demonstrate greatest difference at largest energies Beam position was unknown during the experiment, thus simulation could not reproduce exact conditions Measured e- analyzing power Simulated e- analyzing power

Beam position sensitivity 7 8 9 4 5 6 1 2 3 Simulation of 5.34MeV/c pencil beam e- beam Simulating the analyzing power at different positions along the Y axis (fixed along X axis) reveals a sensitivity to beam position While the analyzing power for the central crystal remain steady throughout the scan, the values for other crystals varies depending on the position of the beam

Simulated Positron Analyzing power GEANT4 simulations allow to link the measured electron analyzing power to the expected positron analyzing power of the PEPPo Compton transmission polarimeter.

Summary The electron beam was used to study and calibrate the Compton transmission polarimeter analyzing power. Geant4 simulation of the central crystal agreed very well with measurements. Sensitivity of outer crystals in simulation may explain difference between measurement and model. The positron analyzing power was obtained directly from the simulation of the central crystal.

PEPPo Collaboration P. Aderley1, A. Adeyemi4, P. Aguilera1, M. Ali1, H. Areti1, M. Baylac2, J. Benesch1, G. Bosson2, B. Cade1, A. Camsonne1, L. Cardman1, J. Clark1, P. Cole5, S. Covert1, C. Cuevas1, O. Dadoun3, D. Dale5, J. Dumas1,2, E. Fanchini2, T. Forest5, E. Forman1, Freyberger1, E. Froidefond2, S. Golge6, J. Grames1, P. Guèye4, J. Hansknecht1, P. Harrell1, J. Hoskins8, C. Hyde7, R. Kazimi1, Y. Kim1,5, D. Machie1, K. Mahoney1, R. Mammei1, M. Marton2, J. McCarter9, M. McCaughan1, M. McHugh10, D. McNulty5, T. Michaelides1, R. Michaels1, C. Muñoz Camacho11, J.-F. Muraz2, K. Myers12, Opper10, M. Poelker1, J.-S. Réal2, L. Richardson1, S. Setiniyazi5, M. Stutzman1, R. Suleiman1, C. Tennant1, C.-Y. Tsai13, D. Turner1, A. Variola3, E. Voutier2,11, Y. Wang1, Y. Zhang12 1 Jefferson Lab, Newport News, VA, US 2 LPSC, Grenoble, France 3 LAL, Orsay, France 4 Hampton University, Hampton, VA, USA 5 Idaho State University & IAC, Pocatello, ID, USA 6 North Carolina University, Durham, NC, USA 7 Old Dominion University, Norfolk, VA, US 8 The College of William & Mary, Williamsburg, VA, USA 9 University of Virginia, Charlottesville, VA, USA 10 George Washington University, Washington, DC, USA 11 IPN, Orsay, France 12 Rutgers University, Piscataway, NJ, USA 13 Virginia Tech, Blacksburg, VA, USA Many thanks for advice, equipment loan, GEANT4 modeling support, and funding to SLAC E-166 Collaboration International Linear Collider Project Jefferson Science Association Initiatives Award